TEST, ADJUST AND BALANCE REPORT

Similar documents
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

NEUDORFER ENGINEERS INC.

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

SECTION TESTING, ADJUSTING, AND BALANCING

AABC Specifications for Testing and Balancing HVAC Systems

Duct Design. Presented by Dave Janquart

product application guide

PROCEDURAL STANDARDS FOR TESTING ADJUSTING AND BALANCING OF ENVIRONMENTAL SYSTEMS

Fan Applications & System Guide

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

CE6500 Energy Recovery Ventilator

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

Balancing of a water and air system

ENGINEERING DATA. Fan Performance Troubleshooting Guide

Welcome. Green HVAC Ductwork Done Right! John Reints, PE Eugene Smithart, PE

How to Measure HVAC System Airflow

Cooktop Low-Profile Ventilation Hoods

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

SECTION AIR INLETS AND OUTLETS

The Air Conditioning Contractors of America (ACCA) Don s History. ACCA History. Defining the Bar Questions

PRICE LIST Test & Balance Report TEST AND BALANCE REPORT Melink Corporation (513)

Centrifugal Fans and Pumps are sized to meet the maximum

Proper Applications & Sequences for Constant Volume Pressure Dependent Zoning Systems. History

2016 HVAC Test and Repair Application Specifications

Type 1 dryers: Domestic dryers to be used primarily in a family living environment. Residences Individual apartments or condominiums

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

Guide Specification SECTION COMMISSIONING OF HVAC PART 1 - GENERAL 1.1 SUMMARY


PANDA SPRAY BOOTH FILTER INFORMATION

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

The CEETHERM Data Center Laboratory

Energy Recovery Ventilation Equipment

Installation and maintenance instructions. Danfoss Vent

Bring the fresh in. Dedicated Outside Air Systems

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

HVAC FORMULAS. TON OF REFRIGERATION - The amount of heat required to melt a ton (2000 lbs.) of ice at 32 F. 288,000 BTU/24 hr. 12,000 BTU/hr.

Duct Leakage Testing 101 Frank Spevak The Energy Conservatory Minneapolis, MN

Application. Design. Structure. Acoustics

Ventilation Solutions Kitchens. fantech

Job Site Electrical Safety A Matter of Life and Death

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

ENHANCED LABORATORY HVAC SYSTEM

Duct Leakage Testing. Ken Helfers, TSI Inc. 2011, TSI Incorporated

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Chapter 3.5: Fans and Blowers

Project Aug 2011 ADRIAN. Prepared by Victor Carroll

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Fan Performance By: Mark Stevens AMCA International Deputy Executive Director Technical Affairs

Innovent LASER Packaged Fresh Air Conditioning Units

High Altitude HVAC. Silvertip Integrated Engineering Consultants

HVAC INDOOR MAKE-UP AIR HANDLERS

HVAC ENGINEERED PRODUCTS Application Manual

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

How To Test A Fume Cupboard

Airmanager Industrial HVAC retrofit results July Location Description:

HP switch LP switch Discharge thermo Comp. Surface thermo

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

Demand Based Static Pressure Reset Control for Laboratories

HVAC Systems in Schools & Commercial Buildings and Radon

TENANT DESIGN MANUAL UPDATED JULY 2015

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Direct Gas-Fired Indoor and Outdoor Heating and Make-Up Air Units

Air Side Economizers and Energy Recovery - Improvements and New Regulations. Richard Lord

Technical data UNIBLOCK UBSF

Testing Capabilities. Worldwide Designers & Manufacturers of Air Moving Equipment

HOSPITAL ISOLATION ROOM HVAC SYSTEM DESIGN

How To Save Energy On A Power Supply

HVAC Checklist - Long Form

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

Energy Design Resources Commissioning Plan Outline Template

Miniatur Radial Gebläse mit integrierter Elektronik Miniature Radial Blower with integrated electronic

Variable Air Volume - VAV

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

Design Calculation or Analysis Cover Sheet. Complete only applicable items M8C-VCTO B

Surface Technology. Centrifugal Fan GMD

NADCA White Paper: Restoring Energy Efficiency Through HVAC Air Distribution System Cleaning

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

RFHD. ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d. According EU Regulation

New Jersey BPU Energy Audits CHA #19860 Building: Kingwood Township School

EACO DOP / PAO TESTING GUIDELINE 2013

Commercial Gas Furnace Upflow

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

Performance Rating of Room Fan- Coils

HVAC Basic Science - System Capacity

HVAC Air Duct Leakage. November 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA

Kitchen Ventilation Systems: Part 2 Providing Adequate Makeup Air

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Test Code: 8297 / Version 1

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Sustainable Smart Laboratories

SUNON SPECIFICATION FOR APPROVAL

Integrating Kitchen Exhaust Systems with Building HVAC

Transcription:

978 Lakeview Drive Green Bay, WI 54313 Tel: (920)-434-0840 Fax: (920)-434-0240 TEST, ADJUST AND BALANCE REPORT SEPTEMBER, 2005 PROJECT UW STEVENS POINT #04A3K BERG GYMNASIUM STEVENS POINT, WISCONSIN ARCHITECT RAASCH ASSOCIATES GREEN BAY, WISCONSIN ENGINEER RAASCH ASSOCIATES GREEN BAY, WISCONSIN CONTRACTOR SCHECK MECHANICAL, INC. APPLETON, WISCONSIN Page 1 of 13

CERTIFICATION PROJECT ADDRESS UW STEVENS POINT #04A3K STEVENS POINT, WI THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH NEBB STANDARD PROCEDURES. ANY VARIANCES FROM DESIGN QUANTITIES WHICH EXCEED NEBB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED AND BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING - ADJUSTING - BALANCING OF ENVIRONMENTAL SYSTEMS" AND THE PROJECT SPECIFICATIONS. NEBB CONTRACTOR NEW TAB of GREEN BAY, INC. REG. NO 2949 CERTIFIED BY Ken Sikora DATE SEPTEMBER, 2005 THE HYDRONIC DISTRIBUTION SYSTEMS HAVE BEEN TESTED AND BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING - ADJUSTING - BALANCING OF ENVIRONMENTAL SYSTEMS" AND THE PROJECT SPECIFICATIONS. NEBB CONTRACTOR NEW TAB of GREEN BAY, INC. REG. NO 2949 CERTIFIED BY Ken Sikora DATE SEPTEMBER, 2005 SUBMITTED AND CERTIFIED BY: NEBB CONTRACTOR TAB SUPERVISOR NEW TAB of GREEN BAY, INC. Ken Sikora REG. NO. 2949 DATE SEPTEMBER, 2005 Page 2 of 13

Instrument Calibration PROJECT INSTRUMENTSERIAL # APPLICATION DATES OF USE CALIBRATION TEST DATE DWYER 657350 STATIC PRESSURES 01-16-06 01-10-05 EXTECH L512292 RPM 01-16-06 01-10-05 FLUKE 77050205 TEMPERATURES 01-16-06 01-10-05 FLUKE 61961068R VOLTSAMPS 01-16-06 01-10-05 SHORTRIDGE M92564 DUCT TRAVERSE 01-16-06 01-10-05 SHORTRIDGE M92564 FLOW HOOD 01-16-06 01-10-05 SHORTRIDGE M92564 DUCT TRAVERSE 01-16-06 01-10-05 SHORTRIDGE M92564 FLOW HOOD 01-16-06 01-10-05 M93104 01-16-06 Page 3 of 13

RE: O.A. and S.A. settings PROJECT UW STEVENS POINT #04A3K RE: O.A. and S.A. settings 01 Mode 1 (Min. occ.) with 750 cfm O.A. at 50% each. The Actual is SF-1 at 833 and SF-2 at 772. 02 Mode 2 (Open GymPE Class) with 1500 cfm O.A. 100% S.A. The Actual of SF-1 is 1667. SF-2 is 1530. 03 Mode 3 (Sporting Event) 5500 cfm O.A. 100% S.A. The actual is SF-1 6115 and SF-2 5665. 04 Mode 4 (Max. Capacity) is 8250 cfm O.A. 100% S.A. The actual is SF-1 9173 cfm and SF-2 85497 cfm. Page 4 of 13

SUMMARY FOR DSF # 04A3K PROJECT UW STEVENS POINT #04A3K SUMMARY FOR DSF # 04A3K 01 WE COULD NOT GAIN ACCESS TO THE DUCTWORK BELOW RX-2 AND RX-3 TO DO A DUCT TRAVERSE. THEREFORE, USING RPM AND SP ON THE FAN CURVE; WE DETERMINED THE AIRFLOWL. IN FACT, THE ACTUAL RPM AND SP ARE REASONABLY CLOSE TO THAT SPECIFIED. Page 5 of 13

Fan PROJECT UW STEVENS POINT #04A3K LOCATION STEVENS POINT, WI FAN DATA FAN NO. RX-1 FAN NO. RX-2 FAN NO. RX-3 LOCATION ROOF ROOF ROOF SERVICE EXHAUST EXHAUST EXHAUST MANUFACTURER COOK COOK COOK MODEL NO. 210 HLC 210 HLC 210 HLC SERIAL NO. 012S8293921601 012S8293921602 012S8293921603 TYPE CLASS - - - MOTOR MAKE STYLE MARATHON MARATHON MARATHON MOTOR HPRPMFRAME 34 1725 56 34 1725 56 34 1725 56 VOLTSPHASEHERTZ 200360. 200360. 200360. F.L. AMPS S.F. 3.2 1.25 3.2 1.25 3.2 1.25 MTR SHEAVE MAKEMODEL BROWNING BROWNING BROWNING MTR SHEAVE DIAMBORE 3-14" 58" 3-14" 58" 3-14" 58" FAN SHEAVE MAKE BROWNING BROWNING BROWNING FAN SHEAVE DIAMBORE 5-14" 34" 5-14" 34" 5-14" 34" NO. BELTS MAKESIZE 1 GOODYEAR A50 1 GOODYEAR A50 1 GOODYEAR A50 SHEAVE DISTANCE 20" 20" 20" BUSHING FILTER OPEN OPEN OPEN TEST DATA DESIGN ACTUAL DESIGN ACTUAL DESIGN ACTUAL CFM (ls) 4500 4500 4500 4400 4500 4500 FAN RPM 798 807 798 795 798 801 S.P. IN OUT -.170 -.150 -.180 TOTAL S.P..2.17.2.15.2.18 VOLTAGE 200 206206207 200 207207206 200 207206207 AMPERAGE 3.2 2.22.22.5 3.2 2.12.32.4 3.2 2.32.42.5 OUTSIDE AIR O.A. Remarks: RX-1: NO ACCESS TO TRAVERSE THE ABOVE THREE FANS. (RX-1,2 & 3) AIRFLOW DETERMINED OFF THE MNFG'S FAN CURVES. TEST DATE: SEPTEMBER 06, 2005 READINGS BY: Mike Hutchinson Page 6 of 13

Fan PROJECT UW STEVENS POINT #04A3K LOCATION STEVENS POINT, WI FAN DATA FAN NO. RX-4 FAN NO. SF-1 FAN NO. SF-2 LOCATION ROOF SOUTH M. ROOM SOUTH M. ROOM SERVICE EXHAUST - MANUFACTURER COOK COOK COOK MODEL NO. 402 HLC 365 CAS 365 CAS SERIAL NO. 012S8293922901 012S8293923901 012S8293925801 TYPE CLASS - -1-1 MOTOR MAKE STYLE BALDOR BALDOR BALDOR MOTOR HPRPMFRAME 5 1750 184T 15 1765 254T 15 1765 254T VOLTSPHASEHERTZ 200360 200360 200360 F.L. AMPS S.F. 15 1.15 40.7 1.15 40.7 1.15 MTR SHEAVE MAKEMODEL BROWNING BROWNING BROWNING MTR SHEAVE DIAMBORE 6" 7-12" Q1 1-58 7-12" Q1-1-78" FAN SHEAVE MAKE BROWNING BROWNING BROWNING FAN SHEAVE DIAMBORE 15-14" 1-516 16-12" Q1-1-1516 16-12" Q1 1-1516 NO. BELTS MAKESIZE 2 GOODYEAR A92 2 BROWNING B133 2 BROWNING B133 SHEAVE DISTANCE 30-12" 50" 50" BUSHING FILTER 2 TURNS TO OPEN 15TA24-24-2 15TA24-24-2 TEST DATA DESIGN ACTUAL DESIGN ACTUAL DESIGN ACTUAL CFM (ls) 21000 21010 18800 20904 18800 19363 FAN RPM 504 515 876 637 876 705 S.P. IN OUT -.470 -.51.70 -.68.81 TOTAL S.P..25.47 2.0 1.21 2.0 1.49 VOLTAGE 200 201202200 200 207208207 200 207206206 AMPERAGE 15 14.914.613.5 40.7 27.126.626.5 40.7 26.427.626.6 OUTSIDE AIR O.A. Remarks: TEST DATE: SEPTEMBER 06, 2005 READINGS BY: Mike Hutchinson Page 7 of 13

Rectangular Duct Traverse PROJECT UW STEVENS POINT #04A3K SYSTEMUNIT RX-4 LOCATION STEVENS POINT, WI SERVICE ALTITUDE DENSITY CORR. FACTOR 1.0 DUCT REQUIRED ACTUAL S.P. AIR TEMP SCFM(SLS) SCFM(SLS) SIZE 141x39 AREA 38.19 FPM(MS) 550 CFM(LS) 21000 FPM(MS) 530 CFM(LS) 20245 DISTANCE FROM DUCT EDGE 6-38 19-14 32 44-78 57-58 70-12 83-38 96-18 109 121-34 134-58 DISTANCE FROM BOTTOM POS 1 2 3 4 5 6 7 8 9 10 11 2-34 1 456 477 539 510 645 683 357 455 539 8-38 2 442 509 486 488 647 747 374 477 566 13-78 3 436 512 560 569 640 720 414 484 556 19-12 4 446 481 509 604 629 668 433 498 529 25-18 5 30-58 6 36-14 7 Remarks: 8 9 10 11 VELOCITY SUB-TOTALS 1780 1979 2094 2171 2561 2818 1578 1914 2190 TEST DATE: 06-09-05 READINGS BY: Mike Hutchinson Page 8 of 13

Air Outlet (Flow Hood) PROJECT UW STEVENS POINT #04A3K SYSTEMUNIT RX-4 OUTLET MANUFACTURER TEST APPARATUS AREA SERVED OUTLET DESIGN PRELIMINARY FINAL %OF DSGN NO. TYPE SIZE AIRFLOW CFM AIRFLOW CFM AIRFLOW CFM RX-4 GYM 100 01 GR 48X40 7000 6500 6860 GYM 100 02 GR 48X40 7000 8390 7340 GYM 100 03 GR 48X40 7000 6310 6810 TOTAL 21000 21200 21010 TEST DATE: SEPTEMBER 14, 2005 READINGS BY: MIKE HUTCHINSON Page 9 of 13

Rectangular Duct Traverse PROJECT UW STEVENS POINT #04A3K SYSTEMUNIT SF-1 LOCATION STEVENS POINT, WI SERVICE ALTITUDE DENSITY CORR. FACTOR 1.0 DUCT REQUIRED ACTUAL S.P. AIR TEMP SCFM(SLS) SCFM(SLS) SIZE 119x72 AREA 59.50 FPM(MS) 316 CFM(LS) 18800 FPM(MS) 447 CFM(LS) 26614 DISTANCE FROM DUCT EDGE 5-38 16-14 27 37-78 48-58 59-12 70-38 81-18 92 102-34 113-58 DISTANCE FROM BOTTOM POS 1 2 3 4 5 6 7 8 9 10 11 3-14 1 443 563 561 422 604 533 391 361 461 499 9-78 2 498 547 513 506 454 522 453 469 445 518 16-38 3 472 488 435 406 447 541 456 512 337 571 22-78 4 328 424 475 509 454 460 512 494 475 483 29-12 5 432 305 472 373 471 259 394 425 331 440 36 6 330 321 339 353 361 392 431 446 501 420 42-12 7 49-18 8 55-58 9 62-18 10 68-34 11 VELOCITY SUB-TOTALS 2503 2648 2795 2569 2791 2707 2637 2707 2550 2931 Remarks: ABOVE READINGS TAKEN AT 60 HZ OR 811 FAN RPM. FINAL DESIGN AIR FLOW IS 41 HZ, VIA THE VFD. NOTIFIED JOHNSON CONTROLS TO SET. TEST DATE: 06-09-05 READINGS BY: Mike Hutchinson Page 10 of 13

Air Outlet (Flow Hood) PROJECT UW STEVENS POINT #04A3K SYSTEMUNIT SF-1 OUTLET MANUFACTURER TEST APPARATUS AREA SERVED OUTLET DESIGN PRELIMINARY FINAL %OF DSGN NO. TYPE SIZE AIRFLOW CFM AIRFLOW CFM AIRFLOW CFM SF-1 R.A. GYM 100 01 RA 48X72 9400 8269 8269 GYM 100 02 RA 48X72 9400 8455 8455 TOTAL 18800 16724 16724 THE FINAL R.A. OF 16724 CFM, PLUS THE REQUIRED O.A., WILL EQUAL THE FINAL S.A. CFM OF 20904. SF-1 S.A. GYM 100 01 SA 48X72 9400 14312 10975 GYM 100 02 SA 48X72 9400 12302 9929 TOTAL 18800 26614 20904 TEST DATE: SEPTEMBER 14, 2005 READINGS BY: MIKE HUTCHINSON Page 11 of 13

Rectangular Duct Traverse PROJECT UW STEVENS POINT #04A3K SYSTEMUNIT SF-2 LOCATION STEVENS POINT, WI SERVICE ALTITUDE DENSITY CORR. FACTOR 1.0 DUCT REQUIRED ACTUAL S.P. AIR TEMP SCFM(SLS) SCFM(SLS) SIZE 119x72 AREA 59.50 FPM(MS) 316 CFM(LS) 18800 FPM(MS) 372 CFM(LS) 22110 DISTANCE FROM DUCT EDGE 5-38 16-14 27 37-78 48-58 59-12 70-38 81-18 92 102-34 113-58 DISTANCE FROM BOTTOM POS 1 2 3 4 5 6 7 8 9 10 11 3-14 1 321 317 310 310 225 296 445 390 435 526 9-78 2 210 317 394 320 471 439 432 428 487 664 16-38 3 299 335 307 327 316 475 442 486 425 576 22-78 4 329 332 365 397 407 415 376 325 434 376 29-12 5 215 256 386 359 404 271 472 520 488 415 36 6 221 224 156 220 376 370 263 414 294 491 42-12 7 49-18 8 55-58 9 62-18 10 68-34 11 VELOCITY SUB-TOTALS 1595 1781 1918 1933 2199 2266 2430 2563 2563 3048 Remarks: ABOVE READINGS TAKEN AT 60 HZ OR 805 FAN RPM. FINAL DESIGN AIR FLOW IS 49 HZ, VIA THE VFD. NOTIFIED JOHNSON CONTROLS TO SET. TEST DATE: 06-09-05 READINGS BY: Mike Hutchinson Page 12 of 13

Air Outlet (Flow Hood) PROJECT UW STEVENS POINT #04A3K SYSTEMUNIT SF-2 OUTLET MANUFACTURER TEST APPARATUS AREA SERVED OUTLET DESIGN PRELIMINARY FINAL %OF DSGN NO. TYPE SIZE AIRFLOW CFM AIRFLOW CFM AIRFLOW CFM SA-2 S.A. GYM 100 01 48X72 9400 11094 9980 GYM 100 02 48X72 9400 11016 9382 TOTAL 18800 22110 19362 SF-2 R.A. GYM 100 01 RA 48X72 9400 7688 7688 GYM 100 02 RA 48X72 9400 7801 7801 TOTAL 18800 15489 15489 THE FINAL R.A. OF 15489 CFM, PLUS THE REQUIRED O.A., WILL EQUAL THE FINAL S.A. CFM OF 19362. TEST DATE: SEPTEMBER 14, 2005 READINGS BY: MIKE HUTCHINSON Page 13 of 13