Cosasco Wireless System



Similar documents
Microcor Wireless Transmitter (MWT)

Rohrback Cosasco Systems

Features: RMU REMOTE MONITORING UNIT AND WEB-BASED SOFTWARE

Wireless Field Data Backhaul

Wireless Sensor Networks

MODEL 9020 & 9020-OEM CORRATER TRANSMITTER USER MANUAL

Wireless Remote Video Monitoring

Wireless Remote Video Monitoring

Tank Gauging & Inventory Management Solutions

No Wires No Limits With Smart Wireless Technology. V.Suresh Senior Sales Manager Emerson Process Management

Wireless Mobile Workforce

Wired versus wireless trade-offs

Easy and efficient asset management for your business

Wireless Process Control Network Architecture Overview

Measurement Products. FieldKey Wireless Adapter Unlock the process and maintenance information stranded in your field instruments

Marco Colombi Account Manager

SEE MORE. DO MORE. Bob Karschnia VP Wireless

System 800xA Networks Control. Monitor. Communicate.

HC900 Hybrid Controller When you need more than just discrete control

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Power & Environmental Monitoring

Session 14: Functional Security in a Process Environment

WIRELESS INSTRUMENTATION TECHNOLOGY

Choosing the Right Industrial Wireless Network

Integration of Wireless Hart Into DCS For Asset Monitor Applications

Distributed Temperature Sensing - DTS

Tnet WIRELESS MESH SENSOR NETWORKS

Roxar Electrical Resistance (ER) Probes 2 Retrievable System

Iknaia Asset and Personnel Tracking Management System for the Construction Industry

Wireless Video Best Practices Guide

General Purpose ph/orp Sensors

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

Honeywell Corrosion Solutions

AMS Suite: Intelligent Device Manager with the DeltaV system

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet

Process Alarm Solutions

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

INSERT COMPANY LOGO HERE

Smart Wireless Solutions. Intelligent Well Production Starts Here

PROCESS AUTOMATION FLEXIBLE ASSET MANAGEMENT HART INTERFACE SOLUTIONS

Performance Driven Remote Monitoring and Control Solutions

Evolving your plant with Field Digital Solutions

Honeywell s OneWireless Network - The Building Blocks of Reliability Vibhor Tandon, Honeywell Process Solutions

AMS Suite: Intelligent Device Manager

Electronic Flow Switches

REMOTE MONITORING OF ER PROBES USING A 900MHZ MESH NETWORK

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Industrial Wireless Solutions - Advantages and Disadvantages

ABB North America. Substation Automation Systems Innovative solutions for reliable and optimized power delivery

End-to-end technology solutions and services

Wireless solutions for water and wastewater management

Improving SCADA Operations Using Wireless Instrumentation

Automation Technology Helps Precast Producer Reduce Energy Consumption and Lower Costs

Improved Asset Management of a Gas Processing Facility. By an Automated Corrosion Management System

Software improves alarm management and KPI reporting at UK-based power station

Understanding Device Level Connection Topologies

Universal Adapters for Remote Monitoring

Climate Ready Shade Operating Systems for residential applications.

Process Automation and Instrumentation Market by Types, Technology, Application and by Geography - Analysis & Global Forecasts to

Iknaia Asset and Personnel Tracking Management System for the Healthcare Industry

WiFi Edition

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Increase System Efficiency with Condition Monitoring. Embedded Control and Monitoring Summit National Instruments

REMOTE MONITORING AND CONTROL SYSTEM

Applying Mesh Networking to Wireless Lighting Control

Tank Gauging Products for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory Measurement

Cisco Aironet 1520 Series Lightweight Outdoor Access Points

Monitoring Water Quality For Today s Demanding World

Wireless Sensor Networks

Micro Motion 3098 Gas Specific Gravity Meter

System Solutions. Industry-Leading Expertise and Field-Proven Technologies Delivering Innovative Wireless System Solutions

Early Warning Fire Detection and Integrated Security Solution. System Overview

Entis Pro Inventory Systems Global Experience. Locally Applied.

How To Make An Ultrasonic Sensor

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Intelligent Terminal Automation System

sierra monitor corporation Fire and Gas Detection Systems

Submersion/Insertion Toroidal Sensor

RecipCOM. Expertise, reciprocating compressor monitoring and protection tailored to your needs

S-series SQ Controller

Field Wireless Solution Based on ISA100.11a to Innovate Instrumentation

The data can be transmitted through a variety of different communications platforms such as:

How To Use A Flowmeter

TCP/IP Network Communication in Physical Access Control

Best Practices Guide for Obvius Data Acquisition Products

IP Camera Network Installations are More Difficult than Analog Camera Installations? Not So!

PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER

airmax Wireless Broadband CPE Datasheet Models: AG-HP-2G16, AG-HP-2G20, AG-HP-5G23, AG-HP-5G27 High Performance, Long Range Integrated InnerFeed CPE

SCADA Systems. Make the most of your energy. March 2012 / White paper. by Schneider Electric Telemetry & Remote SCADA Solutions

Dissolved Oxygen Sensors

Setting Up the Cisco Unified IP Phone

The Group CYTEK CYTEK PROJECTS CONSULTING

Current Monitoring Kit QUICK START GUIDE

The Cisco and Pelco Industrial Wireless Video Surveillance Solution: Real-Time Monitoring of Process Environments for Safety and Security

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

Boiler Control Solution. Boiler Control Solution. Instruments and Solution for Automatic Boiler Control LF3BUSS02-00EN.

Transcription:

Cosasco Wireless System Wireless Transmitter (Including MWT, QWT, CWT, WE) Features: Highly Secure and Reliable Self Organizing Wireless Mesh Network High Resolution Metal Loss Measurement for all process environments Direct input through Modbus Interface to virtually any Process Automation System Low installed cost International Hazardous Area Certifications WirelessHART 7 protocol Seamlessly Integrates with Emerson Smart Wireless Network The new Cosasco Wireless System from Rohrback Cosasco Systems has redefined corrosion monitoring as a true process parameter. The system is based on Microcor patented high resolution corrosion measurement technology; the industries most widely used and only technologically advanced system capable of operating in any process environment. The 2.4 GHz self-organizing wireless network delivers exceptional data reliability and network stability through its high security communication. Microcor online systems are already known worldwide for their proven accuracy and reliability. The wireless link now adds simplicity, flexibility, and exceptional economy of installation to new or existing installations. The Cosasco Wireless System includes Microcor Wireless Transmitters (MWT), measuring metal loss and rate; Quicksand Wireless Transmitters (QWT) measuring corrosion and erosion rates Corrater LPR Wireless Transmitters (CWT), measuring galvanic corrosion rates and pitting tendencies, and Microcor Wireless Extenders (WE) for wireless network expansion. These transmitters along with supporting access fittings, probes, gateway, corrosion management servers and process interface software comprise the complete corrosion management

system. Alternatively, the MWTs, QWT s, CWTs, and WE s can be added seamlessly to an Emerson Smart Wireless Network or via direct input from the gateway through Modbus Interface to virtually any Process Automation System (PAS), Including Honeywell, Yokogawa, Siemens, ABB, or Endress & Hauser hard-wired or wireless networks (see page 4). With its widespread capability and effectiveness, the wireless system is not only complementary to any process system but a guaranteed maximum return on investment, both in the short and long run, in terms of low installation costs, effective chemical inhibitor use, and asset preservation. The Wireless Transmitters are quickly and easily installed without the time and expense required for wiring. Once installed metal loss and computed corrosion rate is read from the Gateway directly into your DCS/SCADA system, an RCS ICMS3-Amulet Corrosion Management System, or RCS Intelligent Interface Unit for smaller scale systems. The Wireless Transmitters are easily configured using a direct connection to a PC or laptop in a safe area, or through RCS s handheld instrument in hazardous locations. The Wireless Transmitter power module has a typical life of 3 years and is hazardous location certified to allow change out in the hazardous area. Typical wireless range is 1000 (300 m) in optimal conditions and with a clear line of site from transmitter to transmitter or transmitter to gateway, with up to three hops permissible from any transmitter back to its gateway. See individual data sheets for MWT, QWT, CWT and WE specifications. Cosasco Wireless System Overview The Cosasco Wireless System can operate as an independent system or can integrate into your existing DCS/SCADA (See diagram below). The Cosasco Wireless System just like its wired counterpart Microcor Corrosion Monitoring System is flexible, highly accurate, and economical. The basic system architecture comprises the following: 1) Microcor Wireless Transmitters (measuring corrosion) 2) Quicksand Wireless Transmitter (measuring erosion) 3) Corrater (LPR) Wireless Transmitter (available soon) 4) Microcor Wireless Extender (to expand wireless network) 5) Gateway 6) Corrosion Probes & Probe Adapters 7) Access Fittings & Hollow Plugs 8) Proof Cable (if Transmitter is mounted remotely from probe) 9) ICMS3 or IIU Server

System Details Microcor Wireless Transmitters The MWT uses high resolution metal loss measurement providing 18 bit resolution, and is rated for operation in hazardous locations (Class I, Zone 1). MWTs have an allowable operating range of -40 C to 70 C and can operate in virtually any environment. The MWT can be added seamlessly to an Emerson Smart Wireless Network or via direct input from the gateway through Modbus Interface to virtually any Process Automation System. Quicksand Wireless Transmitters The QWT uses the same high resolution metal loss measurement technology to measure erosion rates in systems where sand detection is required. Corrater Wireless Transmitters The CWT is designed for on-line corrosion monitoring of water systems in electrically hazardous areas, and is compatible with MWT s and Emerson Smart Wireless devices. This makes it ideal for refineries, chemical plants and process plants where corrosion must be monitored in a mixture of aqueous and non-aqueous systems. The CWTs patented high frequency measurement on two electrodes for compensation of solution resistance provides the highest accuracy and widest range of operation. This compensation has been further enhanced on this instrument to make it the widest range of operation of all the RCS Corrater instruments. Microcor Wireless Extender The WE is used to expand the wireless network when wireless transmitters are located distances that are out of wireless range direct to the gateway. Gateway The gateway serves as a connection between the wireless transmitters and a host system. The gateway is easily configurable and integrates into a designated control system through serial or ethernet connections. The Gateway is scalable supporting up to 100 wireless devices and is certified for Class I, Div2, and Zone 2. The gateway can communicate directly with the host system using Modbus TCP/IP integration over Ethernet interface and supports communication with host applications using OPC. Corrosion and Erosion Probes Microcor Corrosion Probes are specially designed to provide advanced thermal performance, and reliable operation in all environments including sour service. Two forms of probe element are available flush and cylindrical. Several mounting configurations are available, the most common of which allow the probes to be inserted and removed under full process operating conditions without shutdown. Quicksand Erosion Probes are used to detect sand erosion in oil and gas wells where sand production is common. There are two versions of Quicksand Probes available. The S4500 with a specially designed element support shield is suitable for severe flow or high temperature applications. The S4700 with an angled element is exposed to the flow at a 45 angle, simulating a change in direction in the pipe. Galvanic Probes Corrater probes provide a direct measure of corrosion rate and a qualitative pitting tendency of metals in electrolytes by the technique of linear polarization resistance. These probes employ two replaceable, identical electrodes which are mounted at the end of the probe by threaded, insulated studs. Two electrode probes are suitable for the majority of problems where LPR techniques are applicable. See individual data sheets for complete details. Probe Adapters The probe connecting adapter allows the MWT, QWT & CWT to be close-coupled to the probe and provides a mounting for the transmitter. The probe adapter is the preferred and simplest method of mounting the MWT, QWT & CWT (see probe data sheet for mounting clearance). Access Fitting Assembly & Hollow Plug The probe is mounted onto the pipeline or vessel through a Cosasco Access Fitting Assembly that includes both the hollow plug and body. The mounting configuration allows for safe installation and removal of corrosion or erosion probes under full operating pressure with Cosasco Retriever and Service Valve.

Cable If high vibration or excessive temperature are present or direct mounting of the transmitter to the probe is not feasible, an alternative short connection cable can be used. ICMS3 or IIU Server The Intelligent Interface Unit (IIU) for small to medium-size systems, and the Integrated Corrosion Management System ICMS3 for medium to large systems, communicates through a direct wired and ethernet online connection to integrate into your existing DCS and SCADA systems. The gateway feeds the data from both the MWTs, QWT and CWTs and Emerson Smart Wireless devices into the ICMS3 or IIU via a Modbus interface. The Intelligent Interface Unit (IIU) computes metal corrosion and erosion rates from measurements transmitted from our Microcor and Quicksand sensors, and also provide instantaneous corrosion rates and pitting tendencies in aqueous media via Corrater wireless transmitter. Eliminating the need for expensive custom software, the IIU cost-effectively illustrates metal loss and corrosion/erosion rates through the installed RCS Microcor Tools software. This permits operation as either a blind interface to a SCADA or DCS system, or as a stand-alone corrosion data storage and analysis system. The Integrated Corrosion Management System ICMS3 is the most comprehensive and powerful online corrosion monitoring system available. It is ideally suited for medium to large scale systems, or for small systems with the need for future growth. The ICMS3 corrosion management server is the hub of the corrosion or erosion monitoring system, integrating several forms of corrosion monitoring and process data into one complete online system, shared over a variety of communication links. Corrosion and erosion monitoring can be managed as process parameters with constant data streaming into your preferred system. ICMS3 Amulet Software See ICMS3 and IIU data sheet for complete details. System Integration The Cosasco Wireless System is flexible and can be customized to integrate with your preferred Process Automation System. The MWTs, CWTs, QWTs and WE currently use HART7 Wireless communication allowing seamless integration with Emerson Smart Wireless devices. Currently in development are further communication options, including the ISA 100 standard radio that will allow communication between wireless transmitters and Honeywell, Yokogawa and Endress & Hauser Wireless devices. Regardless of the Process Automation System you use the can be directly connected to your DCS through Modbus/OPC interface.

Product Certifications Please see individual data sheets for MWT and Gateway Product Certifications Ordering Information Microcor Wireless Transmitter See Microcor Wireless Transmitter Data Sheet Quicksand Wireless Transmitter See Quicksand Wireless Transmitter MWT-3905-QS Data Sheet Corrater Wireless Transmitter (Available 2011) Microcor Wireless Extender See Microcor Wireless Extender MWT-3905-WE Data Sheet Gateway See Model R-1420 Wireless Gateway Data Sheet Probe Adapters P/N 745092 for Model M3000 series probes P/N 745093 for Model M4000 & S4000 series probes Corrosion Probes M3000 & M4000 Series (See Microcor Probes Data Sheet) Erosion Probes S4500 & S4700 (See Quicksand Data Sheet) Access Fittings & Hollow Plugs Cosasco Model 50-58 Access Fittings (See Individual Data Sheets) Cosasco Hollow Plug - P/N 550100-1-1 Intelligent Interface Unit See IIU Data Sheet ICMS Server See ICMS3 Data Sheet Cables Transmitter to Probe Cable with Mounting Bracket (Note: Probe adapter require (in conjunction with cable) MWT Remote Mounting Kit (10ft cable) P/N 748497-10 MWT Remote Mounting Kit (15ft cable) P/N 748497-15 11841 East Smith Avenue Santa Fe Springs, CA 90670, USA Tel: (1) 562-949-0123 Fax: (1) 562-949-3065 US Toll Free: 800-635-6898 E-Mail: sales@cosasco.com Web Site: www. cosasco.com Bulletin #156-C Rohrback Cosasco Systems Corrosion Monitoring Equipment is manufactured and sold under one or more of the following US Patents: 4138878, 4238298, 4338563, 4514681, 4537071, 4587479, 4605626, 4625557, 4755744, 4839580, 4841787, 4882537, 5243297. Copyright RCS, Inc.