Simplify simulation of transformer winding temperatures

Similar documents
Turbine Flow Sensor Series VTR

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

BB-18 Black Body High Vacuum System Technical Description

Heating Cable. Construction

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Electronic Flow Switches

MAC-120HE-01 Air-Cooled Chiller

REGULATORS 175/153 Series

Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS

RTD Temperature Probe for the Food/Pharmaceutical Industry

Sanitary Type Electronic Flow Switches

THERMAL MANAGEMENT SOLUTIONS

FLASH TANK ECONOMIZER PRODUCT GUIDE

Tyco PremiAir Pneumatic Actuators

COMBIMASS. Technical Data COMBIMASS eco-bio +

How To Build A Low Voltage Capacitor Lvcp

Know-how makes the difference. Electrical Actuators

SITRANS F flowmeters SITRANS F M

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

V47 Series Temperature Actuated Modulating Water Valves

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Electronic, Digital and Mechanical Vibration Switches

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Duct Temperature Sensors

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

MAST ARMS & POLES. Ornamental Pole Top & Bases

Hydraulic Control Solutions

How To Use A Ds340 (Dsp)

Viscotherm sensor electronic differential pressure transmitter electronic viscosity controller electric control valve power supply unit starter box

Morrison Bros. Co. General Product Specifications

A99B Series Temperature Sensors

Problem / Solution. The problem:

Pipe Temperature Sensors

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

HL Series - Commercial Heaters Tankless Water Heating Solutions

Powers Controls TH 192 S Single Temperature Room Thermostat

4 Posiflow Proportional Solenoid Valves

Penetration. Test Methods

Compliant Terminal Technology Summary Test Report

Wirewound Resistors, Industrial Power, Aluminum Housed, Chassis Mount

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

In-Line Electronic Flow Switches

Table of Contents. TransformerIQ FAQs 1

ATL Fuel Level Sender Probes

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

A S Y N C H R O N O U S M O T O R S

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

System 8. ü ( System 8

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Errors Related to Cable Resistance Imbalance in Three Wire RTDs

Solar Hot Water Heaters

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

General Accessories Hardware

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

Transformer oil cooler ALFA A02

Explosion-Proof Electric Unit Heaters

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

79 GAUGE / THERMOMETER H N O

STB Series Enclosures

OPERATING AND MAINTENANCE MANUAL FOR COMMERCIAL ELECTRIC WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL SE

Digital inductive conductivity transmitter

Heavy Duty Control. Catalog Numbering System. General 8/47. Siemens Industry, Inc. Industrial Controls Catalog. 48 Overload Size

Proximity Transmitters and Seismic Vibration Transmitters

OLI. Oil level indicator

Many Products...One Source

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

50 W Power Resistor, Thick Film Technology, TO-220

PRODUCT SPECIFICATION

Screw Plug Immersion Heaters

Pressure transmitter For general industrial applications Model A-10

Micro Motion 7829 Visconic Viscosity Meter

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

300 Series PA Pump and Cooler Assemblies

Penetration Test Methods

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

SMA Connectors. RF Coax Connectors. Product Facts

Thermal Mass Flow Meter (Series MST)

Micro Motion Model D and DL Coriolis Flow and Density Meters

Heating, air-conditioning, cooling

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Typical Aluminum GFM Mass Flow Meter

VSO MAX HP High Flow Proportional Valve

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Analytical Instruments Smart Analyzer 90 Type SMA

Section 4: NiResist Iron

Product Specification instalert Rapid Messenger Variable Message Sign

The L&J Engineering Model MCG 1500SFI Servo Gauge

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8

Low Voltage Transformers Sealed, General Purpose, Dry Type

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

Transcription:

QUALITROL 130 & Thermal Plate Winding temperature simulation systems Simplify simulation of transformer winding temperatures Flexible options offer simulation solutions for any application Designed for use with QUALITROL temperature indicators and monitors Rugged design and corrosion resistant materials provide long, trouble-free life Product Summary Description Simulates winding temperature by using a proportional current transformer output to power a heating element contained in the well (pocket). Winding temperature is simulated by adding the rise due to the heater output to oil (liquid) temperature. All systems have at least one well for installation of a temperature indicator and/or measurment device (sold separately). Thermal plate is available with up to 3 wells and the 130 series is available with 1 well and up to 2 RTD s. Application For simulation of transformer winding temperature and/or measurement of oil (liquid) temperature. QUALITROL 130 can be used with a remote temperature sensing device and produces measurements directly with RTDs for remote indication and/or SCADA systems.

qualitrol 130 & thermal plate winding temperature simulation systems Simplify simulation of transformer winding temperatures Flexible options offer simulation solutions for any application Designed for use with QUALITROL temperature indicators and monitors Rugged design and corrosion resistant materials provide long, trouble-free life Wells (pockets) and temperature probes with integrated heating elements provide an accurate simulation of the winding or hot spot temperature of the transformer based on transformer load, oil temperature, and heat rise constant from the transformer heat run Wells and temperature probes can be specified without integrated heating elements to provide accurate transformer oil temperature (Thermal Plate only) 130 features a well with an integrated heating element and RTDs to produce a simulated winding temperature directly or by inserting other temperature measurement devices Winding temperature simulation systems can be specified to work with either 1, 2 or 5 Amp CT inputs for transformer load sensing 130 features quick and flexible set up of the winding temperature rise factor with a jumper selectable resistance network across the CT input terminals Thermal Plates offer up to three wells to more efficiently install complex oil and/or winding temperature monitoring Many auto balancing transformers, matching units, and trim resistors are available for other special CT and winding rise requirements TRA-001 transformer can be used for CT currents up to 10 amps 130 features RTD outputs for remote temperature indication where it is most convenient Choose between one or two RTDs within the same 130, in either 100 Ohm (platinum) or 10 Ohm (copper) output 130 can be combined with PT100 converter to produce 4-20 ma output for transmitting signals over long distances Both systems are designed to provide local and/or remote indication by accepting most QUALITROL probes, capillaries, or RTD based temperature sensing devices QUALITROL Thermal Plates feature heating elements made of an etched nickel alloy grid which is resistant to burning-out, while being consistent and stable Brass wells and die-cast aluminum cases with thermosetting powder coat finish provide excellent protection from the elements? Don t see what you need? QUALITROL regularly creates models with special customer requirements. Contact your local sales representative or QUALITROL Application Engineer to review your special requirements.

Configurations for QUALITROL thermal plate Model 3 3 wells with heaters for 3 winding temperature indicators LT Model 1L 1 well with heater for 1 winding temperature indicator, 1 well for 1 liquid temperature indicator LT Model 2L 2 wells with heaters for 2 winding temperature indicators, 1 well for 1 liquid temperature indicator Model 1 well with heater for 1 winding temperature indicator Model 2 2 wells with heater for 2 winding temperature indicators Typical configuration for QUALITROL 130 Winding Temperature System 1) Optional Winding Thermometer A) Input From Current Transformer (CT) 2) Winding Temperature Simulator D) Optional Remote Outputs RTD 1 RTD 2 B) Winding Temperature Calibration System C) Heater Coll

Options and accessories 104-321 Series thermometers Employs a universal probe with adjustable length and various sleeves to adapt to different diameter and length wells Includes interchangeable dials for winding and oil indication Long capillary tube allows gauge to be located at eye level and still reach top oil locations Three Form C contacts provided for cooling, alarm and/or trip functions 103 series RTD 103 series RTD s are available with either Pt100 (platinum 100Ω) or Cu10 (copper 10Ω) for use with QUALITROL Thermal Plate products Provides a temperature sensing range of -60 to 200ºC The 103-050 series of RTD s are specifically designed for use in three-well thermal plate applications Trim resistors Adjustable Resistor Assemblies allow easy calibration of the Thermal Plate s heating element to your CT circuit 8/32 studs and insulating shock mounts for quick installation into a control cabinet TRA-001-1 auto-balancing transformer The TRA-001 auto-balancing transformer adjusts the input from the current transformer to the acceptable range needed for the heating element to simulate winding temperature Accepts CT currents up to 10A and has many current taps to achieve the desired current level Compact 4.88 (124 mm) x 4.5 (114 mm) footprint with four bolt slots for easy installation into transformer enclosures Email info@qualitrolcorp.com www.qualitrolcorp.com

qualitrol 130 & thermal plate winding temperature simulation systems 130 Series TECHNICAL SPECIFICATIONS Mechanical Mounting Top or side mount Number of wells 1 Tank connection G 1.00 fits transformer well per DIN 42554 Materials Probe Brass Probe Connection Case Brass Die-cast aluminum with ANSI #70 light gray coating Environmental Std. operating temperatures -40 to 158ºF. (-40 to +70ºC) Oil temperature range -40 to 275ºF. (-40 to +135ºC) Weatherproof DIN 40050 IP54 compliant (NEMA 3R) Ambient humidity 0-95% non-condensing Electrical Electrical connection type Screw terminals Number of RTDs Output type CT current Calibration range Dielectric strength 1 or 2 (platinum [100 ohms] or copper [10 ohms]) Optional RTD output (Pt100 or Cu10) 1 amps nominal (2 amps MAXIMUM under overload) Winding temperature rise adjustable from 0 to 38ºC, at 30ºC oil temperature, 2ºC increments 2000 VAC for one minute thermal plate TECHNICAL SPECIFICATIONS Mechanical Mounting Side mount (flange) Number of wells 1, 2 or 3 Diameter of plate Mounting hole diameter Probe connections 4 (102 mm) [single well], 6.5 (165 mm) [three wells] 2 (51 mm) [single well], 4 (102 mm) [three wells] O-ring, 7/8-14 UNF-2B Materials Probe Stainless steel Probe Connection Heating element Case Brass Nickel alloy Die-cast aluminum with ANSI #70 light gray coating Electrical Electrical connection type Screw terminals CT current Resistance of heater (and leads within thermal plate) 5 amps 0.164 ohms Email info@qualitrolcorp.com www.qualitrolcorp.com

qualitrol 130 & thermal plate winding temperature simulation systems 130 Series Thermal plate (3 winding temperature model shown) Ω Ω Ω About QUALITROL QUALITROL Company LLC manufactures substation and transformer monitoring and protection devices used by electric utilities and manufacturing companies. It is the global leader in sales and installations of transformer asset protection equipment, fault recorders and fault locators. Established in 1945, QUALITROL Company produces thousands of different types of products on demand, each customized to customers unique requirements. 2008 QUALITROL Company LLC, an ISO 9001 system certified company. All rights reserved. Information subject to change without notice. All trademarks are properties of their respective companies, as noted herein. AP-T03-01L-02E. Email info@qualitrolcorp.com www.qualitrolcorp.com