DIN EN ISO Requisiti di qualità per la saldatura certificati PREXTHERM RSW. Pressurised steel boilers UNI EN 729-2

Similar documents
1 DESCRIPTION OF THE APPLIANCE

Originators of the Flexible Water Tube design

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Providing reliable energy-efficient boilers B O I L E R S

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

High-efficient gas boiler CompactGas

Clinic Washer-Disinfectors. Washer-Disinfector Line

Vacuum drying oven for non-flammable solvents

HEAVY DUTY STORAGE GAS

Laddomat Charging unit

Stove-boiler for solid fuels KW Directions for use and assembling

Spare Parts List M96A.24SM/B M96A.28SM/B

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

UDSA - UDSBD unit heater

Commercial Gas Furnace Upflow

Technical data. Danfoss DHP-A

Rotary screw compressors kw 5,5 7, , bar MODULO

Midland Combustion Electric Line Heaters with Integral Panels

CABINET. A Clean Burn Heat Exchanger provides approximately 200% more surface area for capturing combustion heat. You get more heat from less oil.

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

Description of functions

SHOWERS SHOWERS

Operating instructions

Operating instructions

REDFYRE CENTRAL-HEATING COOKER (OIL & GAS FIRED)

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Blowdown vessels Meeting the requirements of HSE PM60

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling

R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler

RPV - RP - RA air handling units

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Transformer oil cooler ALFA A02

Direct steam injection humidifiers

Condensing Boiler Efficiency

Electric Flow Boiler

User's Instructions. Alpha HE CB25/33 and HE SY25

Boiler & Pressure Vessel Inspection discrepancies and failures

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

MэKEMMEL MUTFAKLAR YARATIR CREATING THE PERFECT KITCHEN. TэV-CB ISO 9000 QUALITY MANAGEMENT SYSTEM TURKEY PRODUCT CETIFICATE RUSSIA PRODUCT

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

Baxi Combi 80e & 105e

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Energy Saving Fact Sheet Boilers

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

AMBASSADOR (KITCHEN), COUNTRYMAN (OUTDOOR) & CONSUL (BOILERHOUSE) CONSENSING BOILERS SENATOR (KITCHEN) & COUNTRYMAN (OUTDOOR) COMBI CONSENSING BOILERS

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

DRYPOINT RA REFRIGERATION DRYER RANGE

Safety Storage Cabinets

Session 2: Hot Water Supply

Response: The combi boiler. Response: The fit anywhere combi

Oil and Coolant Circulating Heating System. Model - OCSM

OilonChooser Operating Instructions

Operators manual Basic water heater

INTEC Engineering GmbH Heating Solutions for the Marine Industry

High efficiency, cast-iron gas boiler

The soot and scale problems

ECOplus Solar Cylinder

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Free piston Stirling engine for rural development

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems


SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Refrigeration Compressed Air Dryer Buran Ultrapulse

Installation and Service Instructions. Neutralization System Part no Grünbeck part no

Steam System Best Practices Condensate System Piping

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

ECOCIAT. Domestic hot water heat recovery unit

MÜKEMMEL MUTFAKLAR YARATIR CREATING THE PERFECT KITCHEN TÜV-CB ISO 9000 QUALITY MANAGEMENT SYSTEM TURKEY PRODUCT CETIFICATE RUSSIA PRODUCT

Power consumption (kw)


Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Oil, Gas and Dual Fuel Burners

Remeha P 200. Technical information. Pressurized boiler. Heat output: kw

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Operating and Installation Instructions for the SR-plus hot water boiler

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

KONRAD. Hybrid Fancoil Series

SF15K SF05KSS, SF10KSS

Float and Thermostatic Traps Series H, C and X

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

Installation Instructions

For installation guide see reverse of book

Refrigeration Air Dryers. Catalogue

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

ThermoSorb Desiccant Dryers

Transcription:

DIN EN ISO 9001 PREXTHERM RSW Pressurised steel boilers Requisiti di qualità per la saldatura certificati UNI EN 729-2

PREXTHERM RSW PREXTHERM RSW 92-1060 Quadra Series PREXTHERM RSW 1250-3600 Tonda Series The PREXTHERM RSW series heat generators are pressurised combustion boilers with flame reversal in the combustion chamber and three flue gas passes. The historical experience of Gruppo Ferroli S.p.A. in the design and production of steel boilers has ensured the development of a solid and reliable appliance with performance that puts it at the top of its category. The main technical aspects of the design are: The careful design of the heat exchanger shapes, to ensure an optimum ratio between the combustion volumes and the heat exchange surfaces. The materials used ensure the long life of the boiler. Range... The PREXTHERM RSW is made up of two series: QUADRA SERIES 15 models from 92 to 1060 kw TONDA SERIES 6 models from 1250 to 3600 kw 2

Technical In order to increase the heat exchange between the flue gas and the central heating system, the PREXTHERM RSW boilers are fitted with a closed cylindrical furnace in which the flame produced by the burner is reversed from the bottom towards the door, from where the burned gas enters the rear collection chamber. Turbulators The tube bundle has been positioned above the combustion chamber, so that the flue gas is always discharged into a hot environment, preventing the formation of condensate. The burner is not aligned with the combustion chamber, but rather has been moved downwards. This assists the reversal of the flame, reduces the pressure drop on the flue gas side and as a consequence extends the operating range of the generator. The combustion chamber is completely cooled (even at the rear), to ensure a greater heat exchange surface and improve the distribution of the heating load across the walls. The steel body is completely lined with an 80 mm thick layer of glass wool, in turn covered by a sturdy layer of tearproof material. New turbulators have been designed for the PREXTHERM RSW, which improve the heat exchange of the flue gas and at the same time ensure a lower pressure drop than other solutions. A baffle plate has been fitted at the central heating system return inlet to improve the circulation of cold water towards the bottom of the boiler. This solution ensures more uniform distribution of the heat exchange fluid across the boiler s heat exchange surface, achieving maximum heat exchange with less stress on the walls. 3

PREXTHERM RSW Technical FRONT DOOR To ensure the maximum flexibility in terms of positioning in the heating installation and assist the inspection and maintenance of the combustion chamber, the front door has been designed with a reversible opening, either on the right-hand or left-hand side. As well as sealing the combustion chamber, the door is an integral part of the flue gas path. Special attention has been focused on the insulation, so as to guarantee the least possible heat loss and maximum resistance to high temperatures. The door lining in the series Quadra is made from ceramic fibre, while the Tonda series has a double cement lining plus an extra layer of insulating material. To avoid flue gas leaks at high temperatures (which may cause burning and deformations over time), the door has a double door stop with a new-concept locking and centring system. The door can be centred on the combustion chamber with just one simple operation, guaranteeing a perfect seal. The tube bundle protrudes from the rear plate by a few millimetres so as to increase the temperature near the welding. This prevents the formation of condensate and the consequent corrosion of the materials. 4

Controls KEY 1. Pump ON switch 2. Burner ON switch 3. Safety pressure switch reset button 4. Test button 5. Boiler ON switch 6. Boiler water temperature 7. Boiler ON LED 8. 1st burner flame LED 9. 2nd burner flame LED 10. Burner lockout LED 11. Safety pressure switch LED 12. 2nd boiler flame control thermostat TR1 13. 1st boiler flame control thermostat TR1 14. Space for optional temperature controller (not supplied) 7 8 9 10 11 14 13 12 5 4 3 2 1 Flue gas turn diagram 5

PREXTHERM RSW Technical specifications and dimensions PREXTHERM RSW 92-1060 I F B E D A T1 - T3 - T2 1 N O P T3 T1 T2 T1 - T3 - T2 4 2 3 T5 T5 C T6 M G H T4 H T4 Q S L1 L R KEY 1 Control panel 2 Burner attachment flange 3 Smokebox cleaning door 4 Flame inspection window T1 Central heating flow outlet T2 Central heating return inlet T3 Expansion vessel attachment T4 Boiler drain T5 Flue attachment T6 Burner attachment fitting PREXTHERM RSW 92 107 152 190 240 300 350 399 469 525 600 720 820 940 1060 Heat output min kw 60 70 100 137 160 196 228 260 305 341 390 468 533 611 689 max kw 92 107 152 190 240 300 350 399 469 525 600 720 820 940 1060 Heat input min kw 64,3 75 107,3 147,4 170,9 209,5 242,5 277,5 325 364,5 417 502 566 651 731 max kw 99,5 116,3 165 206,5 261 326 378 432 507 567,5 648 781 881 1014 1140 Total boiler capacity l 117 117 154 227 283 274 326 326 421 421 498 707 802 727 819 Water side pressure drop 10 C mbar 8 11 20 12 17 40 48 43 34 40 51 32 40 51 65 15 C mbar 4 6 12 7 10 17 23 32 18 22 28 18 25 25 33 20 C** mbar 2 2 5 3 4 9 13 16 10 12 16 10 18 16 20 Flue gas side pressure drop mbar 0,5 0,7 1,2 1,2 2,3 3,3 4,4 4,4 3,3 4,3 4,8 4,5 5,6 5,4 6 Maximum operating pressure bar 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Dry weight kg 205 205 250 350 425 455 520 520 700 700 810 1030 1105 1205 1330 FITTINGS T1-T2 UNI 2278 PN16 DN 50 DN 50 DN 50 DN 65 DN 65 DN 65 DN 65 DN 65 DN 80 DN 80 DN 80 DN 100 DN 100 DN 100 DN 100 T3 1 1/4 1 1/4 1 1/4 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 2 2 2 DN 65 DN 65 DN 65 DN 65 T4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 T5 øe mm 200 200 200 220 220 220 220 220 250 250 250 350 350 350 350 DIMENSIONS A mm 800 800 800 940 940 940 940 940 1050 1050 1050 1250 1250 1250 1250 B mm 801 801 1051 1053 1303 1304 1554 1554 1554 1554 1854 1856 2046 2046 2306 C mm 911 911 911 1071 1071 1071 1071 1071 1181 1181 1181 1331 1331 1331 1331 D mm 165 165 165 165 165 165 165 165 165 165 165 165 165 165 165 E mm 139 139 139 159 159 159 159 159 185 185 185 204 204 204 204 F mm 164 164 164 164 164 164 164 164 254 254 254 254 254 254 254 G mm 575 575 575 690 690 690 690 690 730 730 730 840 840 840 840 H mm 430 430 430 495 495 495 495 495 518 518 518 565 565 565 565 I mm 1104 1104 1354 1376 1626 1627 1876 1876 1993 1993 2293 2314 2504 2504 2764 L mm 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 L1 mm 72 72 72 68 68 68 68 68 70 70 70 68 68 68 68 M* mm 980 980 980 1140 1140 1140 1140 1140 1250 1250 1250 1400 1400 1400 1400 N mm 176 176 176 180 230 230 230 230 228 228 228 230 230 230 230 O mm 150 150 250 250 350 350 400 400 400 400 400 400 390 390 390 P mm 250 250 400 350 450 450 600 600 600 600 800 800 1000 1000 1000 Q* mm 750 750 750 890 890 890 890 890 1000 1000 1000 1200 1200 1200 1200 R mm 761 761 1011 1013 1263 1264 1514 1514 1514 1514 1814 1816 2006 2006 2266 S mm 575 575 575 1065 1065 1065 1044 1044 1154 1154 1154 1354 1354 1354 1354 6 * Minimum dimensions for passing through the heating plant door ** Temperature difference If used in combination with heavy oil burners, the values indicated must be reduced by around 10%

PREXTHERM RSW 1250-3600 I F B E A A N O P T1 - T3 - T2 1 T1 T3 T2 T1 - T3 - T2 4 C T6 2 M H T5 3 T5 G H T4 Q L1 R KEY 1 Control panel 2 Burner attachment flange 3 Smokebox cleaning door 4 Flame inspection window T1 Central heating flow outlet T2 Central heating return inlet T3 Expansion vessel attachment T4 Boiler drain T5 Flue attachment T6 Burner attachment fitting PREXTHERM RSW 1250 1480 1890 2360 3000 3600 Heat output min kw 813 962 1229 1535 1950 2340 max kw 1250 1480 1890 2360 3000 3600 Heat input min kw 884 1046 1336 1668 2120 2544 max kw 1359 1608 2054 2565 3260 3913 Total boiler capacity l 1270 1363 2000 2153 3142 3276 Water side pressure drop 10 C mbar 86 110 100 150 145 200 15 C mbar 36 54 45 70 65 90 20 C** mbar 25 32 29 42 45 61 Flue gas side pressure drop mbar 6,5 6,8 7 7,2 7,5 7,8 Maximum operating pressure bar 6 6 6 6 6 6 Dry weight kg 1835 2035 2755 3110 4170 4680 FITTINGS T1-T2 UNI 2278 PN16 DN 125 DN 125 DN 150 DN 150 DN 200 DN 200 T3 DN 80 DN 80 DN 100 DN 100 DN 125 DN 125 T4 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 T5 øe mm 400 400 450 450 500 500 DIMENSIONS A mm 1430 1430 1660 1660 1850 1850 B mm 2460 2710 2724 3014 3366 3666 C mm 1580 1580 1810 1810 2000 2000 E mm 233 233 243 243 253 253 F mm 274 274 274 274 274 274 G mm 890 890 1005 1005 1100 1100 H mm 715 715 790 790 850 850 I mm 2967 3217 3241 3531 3893 4193 L mm 120 120 120 120 120 120 L1 mm 71 71 69 69 67 67 M* mm 1738 1738 1968 1968 2158 2158 N mm 762 812 814 864 866 866 O mm 500 550 550 650 1000 1000 P mm 700 850 850 1000 1000 1000 Q* mm 1000 1000 1000 1000 1170 1170 R* mm 2420 2670 2684 2974 3326 3626 * Minimum dimensions for passing through the heating plant door ** Temperature difference If used in combination with heavy oil burners, the values indicated must be reduced by around 10% 7

Ferroli spa 37047 San Bonifacio (Verona) Italy Via Ritonda 78/A tel. +39.045.6139411 fax +39.045.6100233 www.gruppoferroli.com e-mail: export@ferroli.it Cod. 00000/00-10.2005