Electronic Air / Fuel Ratio Control

Similar documents
Heating Controller. Building Technologies HVAC Products

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Electric Rotary Actuator - On/Off or programmable control actuator

OZW30. Central Unit SYNERGYR

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

HERZ-Thermal Actuators

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Digital input modules

Drayton Digistat +2RF/+3RF

Actuators. Building Technologies HVAC Products

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Quick Connect. quick - simple - efficient.

Voltage Regulator SPAU 341 C. Product Guide

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Adjustable room thermostat for heating only or cooling only systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Air damper actuators

RRV934. Multi-controller. Synco living

RM4TG20 three-phase network control relay RM4-T - range V

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Modular I/O System Analog and Digital Interface Modules

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

CompactLogix Power Supplies Specifications

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

is then retained absolutely without interruption.

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

ZC-24DO CANopen I/O Module: 24 Digital Outputs

mecotron Safety relay ESTOP-2 For emergency stop monitoring

MultiViu Flex 7 Data Sheet

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Combi switchbox with integrated 3/2 way pilot valve

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Electronic Control Devices The European Product Catalogue 2007

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Duct Humidity Transmitter

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

TIG INVERTER INSTRUCTION MANUAL

T Substation Maintenance and Commissioning Test Equipment

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

R.C.C.B. s two-pole LEXIC

Technical Data Sheet OPUS A3 STANDARD Full TDS OPUS A3sF,

Technical Data. Dimensions

TX OPEN RS232/485 module

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

HMI display Installation Guide

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

MINI MCR-SL-R-UI(-SP)

SYSTEM DESCRIPTION Termination Boards

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

ABB i-bus KNX SA/S Switch Actuators Product Manual

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Multi-Range Programmable DC Power Supplies 9115 Series

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Inductive sensor NI10-M18-Y1X-H1141

HCR3.2/.. Chipcard reader HOTEL SOLUTION

T7560A,B,C Digital Wall Module

Cable Plug acc. to DIN EN , Form A

Photovoltaic Solar Energy Unit EESFB

optimized for temperature and pressure control through the control of modulating or multi-stage burners

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

ERMA-Electronic GmbH - Max-Eyth-Str Immendingen - Tel: +49(0)7462/ Fax: +49(0)7462/ Technische Änderungen vorbehalten

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic Control Devices The European Product Catalogue 2007

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Multifunction devices

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Product and functional description

Safety technique. Emergency stop module BO 5988 safemaster

Belimo Gateway MP to Modbus RTU - UK24MOD

Digital Pressure Measuring Instrument MDR480

DKG 972 Gas Burner Safety Control

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Panel Meters and Controllers Modular Panel Meter Type EDM 35

DC Electronic Loads 8500 series

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Flush-mounted room thermostats

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Transcription:

ISO 9001 Electronic Air / Fuel Ratio Control 7 871 Electronic control units for modulating single- and dual-fuel burners with enhanced functions for mechanical air / fuel ratio control The are tested and certified to EN 298. They carry the CE mark based on the directives for gas-fired appliances and electromagnetic compatibility. The and this data sheet are intended for use by OEs which integrate the control unit in their products! Use echanical design -dependent control of burner's air damper fuel valves an additional regulating unit Oxygen trim control RPO25... can be connected Optimum burner operation Insert of plug-in design with European standard printed circuit boards two 32-pin DIN connectors an exchangeable relay board for controlling the actuators Supplied without housing Located on the front of the unit are: LED 1 for fuel 1 LED 2 for fuel 2 A 7-segment 3-digit display for burner output, operating phases and fault indication Housings ARG61.0X0 ade of impact-proof plastic With a transparent cover under which are located: A jack for the handheld terminal AZW20.20 An operating mode selector PROG / RUN ust be ordered as a separate item (refer to «Ordering») Landis & Staefa CC1N7871E Juni 05,1998 1/8

Warning notes To avoid personal injury, damage to property or the environment, the following warning notes must be observed! It is not permitted to open, interfere with or modify the unit! The unit must be completely isolated from the mains supply before performing any work in its connection area! Check wiring and all safety functions! Risk of explosion Protection against electric shock hazard on the unit itself and on all electrical connections must be ensured through appropriate mounting! When wiring the unit, AC 230 V mains voltage and extra low voltage must always be run strictly separate to warrant protection against electric shock hazard! Engineering notes Check the electromagnetic compatibility with nearby components! For more details, especially on commissioning, refer to the Basic Documentation P7871! The following burner controls can be used in connection with the : LAL... / LFL... LEC... LGK16... / LOK16... ounting notes Observe the relevant national safety regulations! When commissioning is completed, check the flue gas values! The is designed for flush panel mounting with housing ARG61.010 wall mounting with housing ARG61.040 ounting of screw terminal base to the subassembly: - Terminal 32 at the top - Terminal 2 at the bottom - Wiring to be made according to the plant connection diagram Installation notes Installation and commissioning may only be carried out by qualified staff! Ignition cables must always be laid separate from the unit and other cables while observing the greatest possible distances! Prior to commissioning, check wiring and programming carefully! 2/8 CC1N7871E Juni 05, 1998 Landis & Staefa

Ordering Housings Accessories Air / fuel ratio control With data storage module RZD20 plugged in Air / fuel ratio control For fuel changeover in operation and 50 % disturbance value authority For flush panel mounting, with connection terminals and cover For wall mounting, with connection terminals and cover Handheld terminal, incl. cable KF8859 (L = 2 m) For programming For the detection of faults For the rectification of faults Separate cable for handheld terminal (L = 20 m) Data storage module RVW20.000D27 RVW20.001D27 ARG61.010 ARG61.040 AZW20.20 KF8860 RZD20 Relay board 4 668 9846 0 Exchangeable Plug-in design Conductive plastic potentiometers for actuators (refer to data sheet 7921) Single potentiometer 1 kω / 90 ASZ12.803 Single potentiometer 1 kω / 135 ASZ12.833 Double potentiometer 1 kω / 90 ASZ22.803 Double potentiometer 1 kω / 135 ASZ22.833 Demo case KF8869 Landis & Staefa CC1N7871E Juni 05, 1998 3/8

Technical data Operating voltage AC 230 V ±15 % Connection terminals for 2 x 1.5 mm² ains frequency 50 Hz ±6 % or 1 x 2.5 mm² Power consumption 25 VA Plug-in system design D to DIN 41612 ounting position optional Dimensions of board 100 x 160 mm Safety class II to IEC 730-1 Degree of protection of housing Weight - Front IP 42 to IEC 529 - With housing approx. 1.4 kg - Base IP 10 to IEC 529 - Without housing approx. 0.75 kg Environmental conditions CE conformity Transport IEC 721-3-2 According to the directives of the European Union Climatic conditions class 2K2 Electromagnetic compatibility EC Temperature range -25...+70 C 89/336 EWG incl. 92/31 EEC Humidity < 95 % r.h. Directive for gas-fired appliances 90/396 EEC echanical conditions class 22 (level to EN 298) Operation IEC 721-3-3 Climatic conditions class 3K5 Temperature range 0...+60 C Humidity < 95 % r.h. ing signal X3 Condensation, formation of ice and ingress of - Voltage DC 0...10 V water are not permitted! - Internal resistance 470 Ω Switching capacity of terminals L-Q1 Switching capacity of control outputs Y1...Y6 - Voltage AC 230 V ±15 % - Voltage AC 230 V ±15 % - Current 0.005...2 A - Current max. 5...150 ma eff. - Switching cycles at cos ϕ = 0.6 : 13 x 10 6 Switching capacity of terminals Q4-Q5 / H cos ϕ = 0.8 : 18.8 x 10 6 - Voltage AC 24...265 V cos ϕ = 1 : 20 x 10 6 - Current at AC 230 V 0.005...2A - Current at AC 24 V 0.02...2A Terminals +5 V Extra low voltage inputs - Current 1 ma - Hum voltage max. AC 50 mv (50 Hz) Extra low voltage output terminals U10 - Voltage DC 10 V Terminals B1...B4 - Current (all terminals) max. 50 ma - Voltage DC 0...10 V - Impedance 100 kω Terminals X2, U1 - Voltage DC 0...10 V Terminals TxD - Impedance 25 kω RS-232 level, 9600 Baud, 8 data bits, 1 stop bit, - no parity bit Control inputs Q2, Q3, Y10, Y20, F1, and F2 Permissible running time of actuators 20...120 s - Voltage on AC 187...265 V - Voltage off < AC 50 V Conductive plastic potentiometers - Current on < 1 ma - Resistance 1 kω - Angular rotation 90...135 signal X1 - Refer to «Ordering» - Voltage DC 0...10 V - Internal resistance 100 Ω 4/8 CC1N7871E Juni 05, 1998 Landis & Staefa

Functions General Programming Supervision and display Startup Control mode Shutdown Compensating signal Compensation of hysteresis The controls the actuators in function of the positioning signals delivered by the load controller depending on programmable curves, for each type of fuel synchronously to one another With the help of the handheld terminal AZW20.20 (to be ordered as a separate item) Programming of setpoint curves Programming of other plant parameters Operating mode selector on the must be set to PROG Three channels: For two, three or four actuators Each with two setpoint curves, with a maximum of 17 breakpoints Programmable and stored in non-volatile memory: The ignition position The load-specific operating positions Other parameters By using the data storage module RZD20, the values can be transferred to other If there are inadmissible operational statuses or fualts in the system, the burner will be shut down During startup and shutdown, the shows operating phases 0...9 in the display During operation, the burner's output is displayed as a percentage Faults are indicated by a flashing 2-digit code Burner startup is controlled by the burner control The identifies the startup sequence during the startup phase based on valve and fan control; the actuators are controlled accordingly checks the function of the connected components during the startup sequence runs to the programmed ignition position to allow startup after burner startup, runs to the programmed low flame position When the operating position is reached, the burner control enables the load controller The load controller controls the burner's output via the The positions of the actuators are calculated based on the required output based on the type of fuel selected with the help of the programmed setpoint curves The drives the actuators to the calculated positions The drives the actuators to their start positions after burner shutdown on completion of the post-purge time, if required Changing combustion parameters (e.g. air density or quality of fuel) can be offset by applying oxygen trim control RPO25... and connecting it to the compensating signal input the authority of the compensating variable can be programmed The offsets any mechanical play between actuator and regulating unit The authority of the compensation can be programmed Landis & Staefa CC1N7871E Juni 05, 1998 5/8

Basic diagram AIR1 DC 0...10 V X2 X2 - AIR2 Y1 Y2 SA P AIR B1 DC 0...10 V X1 FUEL1 FUEL2 B2 Y3 SA P FUEL1 Y4 SA P DC 0...10 V U1 LR Y10 Y20 Integrator AUX1 AUX2 B3 FS Y5 Fuel1 Fuel2 SA P FUEL2 AUX Y6 Programming Fuel select Control B4 7871a07/0398 TxD F1 F2 Q3 Q2 Q1 Q4 Q5 H AZW20.20 FS FA Sequence diagram Phase 0 1 2 3 4 5 6 7 R 8 9 0 Betrieb STOP lim1 lim5 t4 Service Operation lim8 Q3 Q2 Y10 Y20 Q1 Q4-Q5 1) 5) 7) 1) 5) 5) 7) R R Quit Ready Y1, Y3, Y5 SA Y2, Y4, Y6 X1 (DC 0...10 V) 2) 4) 5) Burner 3) 2) Output SA A ax IgnPos in IgnitLo Z 6) SA1 (AIR) SA4 (AUX) A ax in IgnitLo Z 6) 7871d01/0398 SA2 (FUEL1) SA3 (FUEL2) Legend Signal must be present or output is live Signal may not be present or output is dead Signal may be present Controlled output Prerequisite for changing to the next phase 1) Signals at Y10 or Y20 only act on output X1 Phase Program phase 2) X1 gives the current air damper position AIR Setpoint curves of air damper actuator 3) X1 gives the current burner output AUX Setpoint curves of auxiliary actuator 4) X1 changes according to signals Y10 and Y20 AZW... Handheld terminal 5) Signals at Y10 or Y20 have no effect lim... Duration of phase 1 is limited to 30 s, phase 5 to 75 s, and phase 8 to 300 s. If, on completion of these 6) If the ignition load (IgnitLo) is set to a level above the minimum burner load, it will be active in phase 7 periods of time, the sequence does not change, the unit will initiate lockout FA Burner control 7) Optionally Y10 / Y20 or analog signal at U1 for controller operation FS Fuel selector P Potentiometer FUEL Setpoint curves of fuel actuator Q...Y Terminal designations (refer to «Connection diagram») LR controller SA Actuators Fan motor t4 Interval 6/8 CC1N7871E Juni 05, 1998 Landis & Staefa

Electrical connections ains voltage side Extra low voltage side Q5 Q4 +5V H Y6 Q3 Y5 GND TxD Y10 Y4 X1 Y3 F1 U1 X2 Y2 F2 U10 U10 Y20 N Q2 Q1 Y1 N N L L B4 U10 B2 B3 U10 B1 7871a03/0398 Legend Terminal Input / Voltage Description output B1 Input DC 0...10 V Feedback signal from air damper actuator B2 Input DC 0...10 V Potentiometer from fuel valve actuator (Fuel1) B3 Input DC 0...10 V Potentiometer from fuel valve actuator (Fuel2) B4 Input DC 0...10 V Potentiometer from auxiliary actuator (AUX) F1 Input AC 230 V Selection of fuel: fuel 1 F2 Input AC 230 V Selection of fuel: fuel 2 GND Reference potential for RS-232 output L Input AC 230 V Live for internal power supply, actuator outputs and Q1 Reference potential for all low voltage inputs / outputs and for the screening (all -terminals are internally interconnected) N Input Neutral for internal power supply, reference potential for mains voltage inputs (all N-terminals are internally interconnected) Q1 Output AC 230 V Acknowledge signal: indicates when certain actuator positions are reached Q2 Input AC 230 V Signal from burner control: first fuel valve on / off Q3 Input AC 230 V Signal from burner control: fan on / off Q4-Q5 / H Output Potentialfree Readiness contact or non-readiness / control loop: indicates when is ready to operate TxD Output Output RS-232 U1 Input DC 0...10 V Signal input for analog burner load control U10 Output DC 10 V Power supply for the potentiometers (all U10 terminals are internally interconnected) X1 Output DC 0...10 V Burner load signal X2 Input DC 0...10 V Compensating signal from oxygen trim control RPO25... Y1 Output AC 230 V ing signal (open) (three-position control of actuators) Y2 Output AC 230 V ing signal (closed) (three-position control of actuators) Y3 Output AC 230 V ing signal (open) (three-position control of actuators) Y4 Output AC 230 V ing signal (closed) (three-position control of actuators) Y5 Output AC 230 V ing signal (open) (three-position control of actuators) Y6 Output AC 230 V ing signal (closed) (three-position control of actuators) Y10 Input AC 230 V Signal for higher burner output from the three-position controller Y20 Input AC 230 V Signal for lower burner output from the three-position controller +5V Output DC 5 V Auxiliary voltage, max. 1 ma Landis & Staefa CC1N7871E Juni 05, 1998 7/8

Dimensions Housing ARG61.040 for wall mounting Dimensions in mm Housing AGG61.010 for flush panel mounting 7871m03/0598 1998 Landis & Staefa Produktion (Deutschland) GmbH 8/8 CC1N7871E Juni 05, 1998 Landis & Staefa