Mount directly to 1.05 jackshafts. (p. 59) AFBUP-S N4(H), AFXUP-S N4 (p. 55) AFB24-SR, AFX24-SR (p. 57) AFBUP-S, AFXUP-S (p. 53)

Similar documents
Installation Instructions

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

WE-350 Series ¼ Turn Electric Actuator

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Series 71, 72, and 76 Modutrol IV Motors

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

Know-how makes the difference. Electrical Actuators

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electric Rotary Actuator - On/Off or programmable control actuator

Quick running actuator

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

HERZ-Thermal Actuators

Electronic Control Devices The European Product Catalogue 2007

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

How To Control A Motorized Motorized Power Control (Motorized Motor Control) (Mft)

Duct Humidity Transmitter

Electronic Control Devices The European Product Catalogue 2007

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

How To Drive A Compact Serie 1

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

HQ Series ¼ Turn Actuator

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Model: DC-A2IO Advanced HVAC Controller

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Single Phase Soft Starter

TorqPlus TM Electric Valve Actuators and Controls

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Air damper actuators

Telefon (+45) Telefax (+45) Installation and operating manual

Absolute Rotary Encoder E6CP

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Safety automation solutions

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Series 90 Modutrol IV Motors

! WARNING. Before using product, read and understand instructions.

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Self Monitoring Power Supply (BPSM)

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Electro-pneumatic control valves

MCR1900 Media Converter 19-Slot Chassis

Spring Return Actuator Product Range Multi-Function Technology

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

38 Series - Relay interface modules A

DUCT SMOKE DETECTOR D4120

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

RAY-MAX Integrated Solar Power Strip

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Operating Instructions

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Digital inductive conductivity transmitter

NEXUS FX04 and FX04-1 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION. FX04-1 Shown

38 Series - Relay interface modules A

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Problem / Solution. The problem:

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Assisted lift operated 2/2-way solenoid valves Type EV250B

ADM1TE 5/30A DIN rail single phase two wire energy meter

40.3. Control Relays and Timers

How To Use A Ds340 (Dsp)

Intersection Preassembled 19-inch Rack

T7560A,B,C Digital Wall Module

Speed Control Relays SX2

UM Series UniModule. Pre-assembled, C-face Clutches and Brakes. Original Design Sizes 210 & 215. GEN 2 Design Sizes 50, 100 & 180

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Digital Controllers ACTUATOR COMPATABILITY

SX460. Generator Automatic Voltage Regulator Operation Manual

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

How To Power A Schen

POWERS Controls No. 4 Pneumatic Damper Actuator

Analog signal converters CC-E I/I Current / current isolators

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Safety Manual BT50(T) Safety relay / Expansion relay

Cross Reference Modutrol IV Motor Cross Reference For Honeywell and Competitive Motors

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Electronic, Digital and Mechanical Vibration Switches

Three-phase monitoring relay CM-PFE

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Transcription:

AF and AFX Series Spring eturn Direct Coupled Actuator Minimum 180 in-lb Torque For damper areas up to 4 sq-ft* (For lower torque, see AF, NF, LF, or TF series) Applications 1 3/4 1/ New standard clamp fits standard 1/ shafts to 1.0 jackshafts. Mount directly to 1.0 jackshafts. Linkage solutions are available when direct coupling is not possible. All Actuators have DCM AF, AFX Series - At A Glance AF4, AFX4 (p. 49) AF4 N4(H), AFX4 N4 (p. 1) AF4-S, AFX4-S (p. 49) AF4-S N4(H), AFX4-S N4 (p. 1) AFUP, AFXUP (p. 3) AFUP N4(H), AFXUP N4 (p. ) AFUP-S, AFXUP-S (p. 3) AFUP-S N4(H), AFXUP-S N4 (p. ) AF4-S, AFX4-S (p. 7) AF4-S N4(H), AFX4-S N4 (p. 9) AF4-S-S, AFX4-S-S (p. 7) AF4-S-S N4(H), AFX4-S-S N4 (p. 9) AF4-MFT, AFX4-MFT (p. 61) AF4-MFT N4(H), AFX4-MFT N4 (p. 63) AF4-MFT-S, AFX4-MFT-S (p. 61) AF4-MFT-S N4(H), AFX4-MFT-S N4 (p. 63) AF4-MFT9, AFX4-MFT9 (p. 6) AF4-MFT9 N4(H), AFX4-MFT9 N4 (p. 67) Torque: 180 in-lb Power supply: 4 VAC/DC 10 VAC 0 VAC Control signal: On/Off to 10 VDC Multi-function** 0 to 13 Ω Feedback signal: VDC variable** unning time <7 seconds motor: 9 seconds Adj. 70 to 0 seconds*** spring: <0 seconds rushless DC Motor External direction of rotation switch Manual override Appliance rated cable, 18 GA (default) Plenum rated cable, 18 GA (optional) uilt-in auxiliary switch, Two SPDT NEMA 4 rated housing Installation instructions...(p. 69-7) General wiring...(p. 77) Start-up and checkout...(p. 78) Electrical operations...(p. 76) *ased on 4 in-lb/ft damper torque loading. Parallel blade. No edge seals. **Default to 10 VDC. ***Default 10 seconds. 47

AF and AFX Series Spring eturn Direct Coupled Actuator A CLOSE LOOK Cut labor costs with simple direct coupling. True mechanical spring return the most reliable fail-safe. everse mount for clockwise or counterclockwise fail-safe. Check damper position easily with clear position indicator. Overload-proof throughout rotation Temporary restrictions in damper movement will not change actuator operation. Actuator returns to normal operation when restriction is removed (modulating actuators). uilt-in mechanical stop to adjust angle of rotation. y eliminating internal condensation incorporated breather membrane optimizes performance in harsh airstream environments. uilt-in auxiliary switches is easy to use, offers feedback or signal for additional device (-S models). Manual override crank speeds installation Need to change control direction? Do it easily with a simple switch (modulating actuators). Microprocessor-controlled brushless DC motor increases actuator life span and reliability, provides constant running time (modulating actuators). ugged metal on plastic housing withstands rough handling in the mechanical room. Standard 3 ft. appliance cable and conduit connector eases installation. Double insulated no need for separate safety ground. A elimo exclusive (-S models). Automatically compensates for damper seal wear, ensuring tight close-off. Added Flexibility to Select Clamp, Electrical Connection, and unning Time to fit your Specific Application with elimo s Flexible of Actuators (AFX). The elimo Difference Customer Commitment. Extensive product range. Application assistance. Same-day shipments. Free technical support. Five year warranty. Low Installation and Life-Cycle Cost. Easy installation. Accuracy and repeatability. Low power consumption. No maintenance. Long Service Life. Components tested before assembly. Every product tested before shipment. 30+ years direct coupled actuator design. 48

AF4, AF4-S, AFX4, AFX4-S On/Off, Spring eturn, 4 V Torque min. 180 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection AF4... AFX4... Overload protection Control Torque Direction of rotation Mechanical angle of rotation unning time AF4, AF4-S, AFX4, AFX4-S 4 VAC ± 0% 0/60 Hz 4 VDC +0% / -10% running holding. 7. VA (class power source) 3 ft, 18 GA appliance cable, 1/" conduit connector -S models: two 3 ft, 18 gauge appliance cables with 1/ conduit connectors 3 ft [1m], 10 ft [3m] or 16 ft [m] 18 GA appliance or plenum cables, with or without 1/ conduit connector -S models: two 3 ft [1m], 10 ft [3m] or 16 ft [m] appliance cables, with or without 1/" conduit connectors electronic throughout 0 to 9 rotation on/off 180 in-lb [0 Nm] minimum spring reversible with C/CC mounting 9 (adjustable with mechanical end stop, 3 to 9 ) motor < 7 seconds spring 0 seconds @ -4 F to 1 F [-0 C to 0 C]; < 60 seconds @ - F [-30 C] Position indication visual indicator, 0 to 9 (0 is full spring return position) Manual override mm hex crank (³ ₁₆" Allen), supplied Humidity max. 9% H non-condensing Ambient temperature - F to 1 F [-30 C to 0 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing Nema, IP4, Enclosure Type Housing material zinc coated metal and plastic casing Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/9/EC Noise level <0d(A) motor @ 7 seconds 6d(A) spring return Servicing maintenance free Quality standard ISO 9001 eight 4.6 lbs (.1 kg); 4.9 lbs (. kg) with switches ated Impulse Voltage 800V, Type of action 1.AA (1.AA. for -S version), Control Pollution Degree 3. AF4-S, AFX4-S Auxiliary switches x SPDT 3A (0.A) @ 0 VAC, UL approved one set at +10, one adjustable 10 to 90 Application For On/Off, fail-safe control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. Control is On/Off from an auxiliary contact, or a manual switch. The actuator is mounted directly to a damper shaft up to 1.0 in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The AF and AFX series actuators provide true spring return operation for reliable failsafe application and positive close off on air tight dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The AF and AFX series provides 9 of rotation and is provided with a graduated position indicator showing 0 to 9. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The AF4-S and AFX4-S versions are provided with two built-in auxiliary switches. These SPDT switches are provided for safety interfacing or signaling, for example, for fan start-up. The switching function at the fail-safe position is fixed at +10, the other switch function is adjustable between +10 to +90. The AF4, AF4-S, AFX4 and AFX4-S actuator is shipped at + ( from full fail-safe) to provide automatic compression against damper gaskets for tight shut-off. Dimensions (Inches [mm]) K7- (supplied) 1/" Centered (Default) 3/4" Centered (Field Selectable) 1.0" Centered (Field Selectable) AFNFDim 49

AF4, AF4-S, AFX4, AFX4-S On/Off, Spring eturn, 4 V Accessories AV 8- Shaft extension IND-AF Damper position indicator KH-AF Crank arm K7- Universal clamp for up to 1.0 dia jackshafts TF-CC US Conduit fitting Tool-06 8mm and 10 mm wrench ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket ZG-118 Mounting bracket for arber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 100 replacement or new crank arm type installations ZG-AF Crank arm adaptor kit ZG-AF118 Crank arm adaptor kit ZS-100 eather shield (metal) ZS-10 eather shield (polycarbonate) ZS-60 Explosion-proof housing ZS-300 NEMA 4X housing Note: hen using AF4, AF4-S, AFX4, AFX4-S actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to elimo iring Guide. Typical Specification On/Off spring return damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a jackshaft up to a 1.0 diameter. The actuators must be designed so that they may be used for either clockwise or counterclockwise fail-safe operation. Actuators shall be protected from overload at all angles of rotation. If required, two SPDT auxiliary switch shall be provided having the capability of one being adjustable. Actuators with auxiliary switches must be constructed to meet the requirements for Double Insulation so an electrical ground is not required to meet agency listings. Actuators shall be culus Approved and have a year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. iring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 4 VDC. 4 For end position indication, interlock control, fan startup, etc., AF4-S and AFX4-S incorporates two built-in auxiliary switches: x SPDT, 3A (0.A) @0 VAC, UL Approved, one switch is fi xed at +10, one is adjustable 10 to 90. Meets culus requirements without the need of an electrical ground connection. ANING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 1 4 VAC Transformer 1 Common + Hot 3 AF4, AF4-S AFX4, AFX4-S 063_AF(X) On/Off wiring for AF4, AFX4 Auxiliary Switches for AF4-S, AFX4-S AF4-S AFX4-S 064_AF(X)_-S 0

AF4 N4(H), AF4-S N4(H), AFX4 N4, AFX4-S N4 NEMA 4, On/Off, Spring eturn, 4 V Torque min. 180 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection AF... N4 AF4 N4(H), AF4-S N4(H), AFX4 N4, AFX4-S N4 4 VAC ± 0% 0/60 Hz 4 VDC +0% / -10% running / heater holding. 7. VA (class power source) / heater VA 3 ft, 18 GA appliance cable, 1/ conduit connector -S models: Two 3 ft, 18 gauge appliance cables with 1/ conduit connectors heater (N4H) terminal block, 6-16 GA AFX... N4 3 ft [1m], 10 ft [3m] or 16 ft [m] 18 GA appliance cable, with or without 1/ conduit connector -S models: Two 3 ft [1m], 10 ft [3m] or 16 ft [m] appliance cables with or without 1/ conduit connectors Overload protection electronic throughout 0 to 9 rotation Control on/off Torque 180 in-lb [0 Nm] minimum Direction of rotation spring reversible with C/CC mounting in housing Mechanical angle of rotation 9 (adjustable with mechanical end stop, 3 to 9 ) unning time motor < 7 seconds spring 0 seconds @ -4 F to 1 F [-0 C to 0 C]; < 60 seconds @ - F [-30 C] spring (with heater) 0 seconds @ -4 F to 1 F [-0 C to 0 C], <60 seconds @ -49 F [-4 C] Position indication visual indicator, 0 to 9 (0 is full spring return position) Manual override mm hex crank (³ ₁₆" Allen), supplied Humidity max. 9% H non-condensing Ambient temperature - F to 1 F [-30 C to 0 C] with heater -49 F to 1 F [-4 C to 0 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing UL Type 4, NEMA 4, IP66 Housing material polycarbonate Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/9/EC Noise level <0d(A) motor @ 7 seconds 6d(A) spring return Servicing maintenance free Quality standard ISO 9001 eight 9.7 lbs (4.4 kg); 10 lbs (4. kg) with switches; 10. lbs (4.8 kg) with heater ated Impulse Voltage 800V, Type of action 1.AA (1.AA. for -S version), Control Pollution Degree 4. AF4-S N4(H), AFX4-S N4 Auxiliary switches x SPDT 3A (0.A) @ 0 VAC, UL approved one set at +10, one adjustable 10 to 90 Application For On/Off, fail-safe control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. Control is On/Off from an auxiliary contact, or a manual switch. The actuator is mounted directly to a damper shaft up to 1.0 in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The AF N4(H) and AFX N4 series actuators provide true spring return operation for reliable fail-safe application and positive close off on air tight dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The AF N4(H) and AFX N4 series provides 9 of rotation and is provided with a graduated position indicator showing 0 to 9. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The AF4-S N4(H), AFX4-S N4 version are provided with two built-in auxiliary switches. These SPDT switches are provided for safety interfacing or signaling, for example, for fan start-up. The switching function at the fail-safe position is fixed at +10, the other switch function is adjustable between +10 to +90. Dimensions (inches [mm]) Clamp Configurations 1/ Field Selectable 3/4 Centered 1.0 Centered (Default) (Field Selectable) 1.99 [330] 1.17 [9.8] 0.79 [0] 3.6 [9.1] 3.36 [8.] 6.4 [163.9] 0.39 [10] 0.9 [.4] 3. [0.14] 6.77 [17] 0.81 [0.] 9.37 [8] 1.1 [8.] D31_Confi g 1

AF4 N4(H), AF4-S N4(H), AFX4 N4, AFX4-S N4 NEMA 4, On/Off, Spring eturn, 4 V Accessories Tool-06 8mm and 10 mm wrench 4344-00001 Gland (needed for additional wires) 11097-00001 Gasket for Gland (needed for additional wires) NOTE: hen using AF4 N4(H), AF4-S N4(H), AFX4 N4, AFX4-S N4 actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to elimo iring Guide. Typical Specification On/Off spring return damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a jackshaft up to a 1.0 diameter. The actuators must be designed so that they may be used for either clockwise or counterclockwise fail-safe operation. Actuators shall be protected from overload at all angles of rotation. If required, two SPDT auxiliary switch shall be provided having the capability of one being adjustable. Actuators with auxiliary switches must be constructed to meet the requirements for Double Insulation so an electrical ground is not required to meet agency listings. Actuators shall be culus Approved and have a year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. iring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 4 VDC. 4 For end position indication, interlock control, fan startup, etc., AF4-S N4(H), AFX4-S N4 incorporates two built-in auxiliary switches: x SPDT, 3A (0.A) @0 VAC, UL Approved, one switch is fi xed at +10, one is adjustable 10 to 90. Meets culus requirements without the need of an electrical ground connection. ANING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 1 4 VAC Transformer 1 Common + Hot 3 063_AF_N4 AF4 N4(H) AF4-S N4(H) AFX4 N4 AFX4-S N4 On/Off wiring Auxiliary Switches AF4-S N4(H) AFX4-S N4 064_AF4_-S_N4 GK-AF-NF N4H 4V heater NEMA 4 Heater

AFUP, AFUP-S, AFXUP, AFXUP-S On/Off, Spring eturn, 4 to 40 VAC Torque min. 180 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection AFUP... AFXUP... Overload protection Control Torque Direction of rotation Mechanical angle of rotation unning time AFUP, AFUP-S, AFXUP, AFXUP-S 4...40 VAC -0% / +10%, 0/60 Hz 4...1 VDC ±10% running 7 holding 3. 7 VA @ 4 VAC (class power source) 8. VA @ 10 VAC 18 VA @ 40 VAC 3 ft, 18 GA appliance cable, 1/" conduit connector -S models: Two 3 ft, 18 gauge appliance cables with 1/ conduit connectors 3 ft [1m], 10 ft [3m] or 16 ft [m] 18 GA appliance cable, with or without 1/ conduit connector -S models: Two 3 ft [1m], 10 ft [3m] or 16 ft [m] appliance cables with or without 1/" conduit connectors Electronic throughout 0 to 9 rotation On/Off 180 in-lb [0 Nm] minimum spring reversible with C/CC mounting 9 (adjustable with mechanical end stop, 3 to 9 ) motor < 7 sec spring 0 sec @ -4 F to 1 F [-0 C to 0 C]; < 60 sec @ - F [-30 C] Position indication visual indicator, 0 to 9 (0 is full spring return position) Manual override mm hex crank (³ ₁₆" Allen), supplied Humidity max. 9% H non-condensing Ambient temperature - F to 1 F [-30 C to 0 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing Nema, IP4, Enclosure Type Housing material Zinc coated metal and plastic casing Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/9/EC Noise level <0d(A) motor @ 7 seconds 6d(A) spring return Servicing maintenance free Quality standard ISO 9001 eight 4.6 lbs (.1 kg), 4.9 lbs (. kg) with switches ated Impulse Voltage 4kV, Type of action 1.AA (1.AA. for -S version), Control Pollution Degree 3. AFUP-S, AFXUP-S Auxiliary switches x SPDT 3A (0.A) @ 0 VAC, UL Approved one set at +10, one adjustable 10 to 90 Application For On/Off, fail-safe control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. Control is On/Off from an auxiliary contact, or a manual switch. The actuator is mounted directly to a damper shaft up to 1.0 in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The AF and AFX series actuators provide true spring return operation for reliable failsafe application and positive close off on air tight dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The AF and AFX series provides 9 of rotation and is provided with a graduated position indicator showing 0 to 9. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The AFUP-S and AFXUP-S versions are provided with two built-in auxiliary switches. These SPDT switches provide safety interfacing or signaling, for example, for fan startup. The switching function at the fail-safe position is fixed at +10, the other switch function is adjustable between +10 to +90. The AFUP, AFUP-S, AFXUP and AFXUP-S actuator is shipped at + ( from full fail-safe) to provide automatic compression against damper gaskets for tight shut-off. Dimensions (Inches [mm]) K7- (supplied) 1/" Centered (Default) 3/4" Centered (Field Selectable) 1.0" Centered (Field Selectable) AFNFDim 3

AFUP, AFUP-S, AFXUP, AFXUP-S On/Off, Spring eturn, 4 to 40 VAC Accessories AV 8- Shaft extension IND-AF Damper position indicator K7- Universal clamp for up to 1.0 dia jackshafts KH-AF Crank arm TF-CC US Conduit fitting Tool-06 8mm and 10 mm wrench ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket ZG-118 Mounting bracket for arber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 100 replacement or new crank arm type installations ZG-AF Crank arm adaptor kit ZG-AF118 Crank arm adaptor kit ZS-100 eather shield (metal) ZS-10 eather shield (polycarbonate) ZS-60 Explosion-proof housing ZS-300 NEMA 4X housing Note: hen using AFUP, AFUP-S, AFXUP, AFXUP-S actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to elimo iring Guide. Typical Specification On/Off spring return damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a jackshaft up to a 1.0 diameter. The actuators must be designed so that they may be used for either clockwise or counterclockwise fail-safe operation. Actuators shall be protected from overload at all angles of rotation. If required, two SPDT auxiliary switch shall be provided having the capability of one being adjustable. Actuators with auxiliary switches must be constructed to meet the requirements for Double Insulation so an electrical ground is not required to meet agency listings. Actuators shall be culus approved and have a year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. iring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 No ground connection is required. 4 For end position indication, interlock control, fan startup, etc., AFUP-S and AFXUP-S incorporates two built-in auxiliary switches: x SPDT, 3A (0.A) @0 VAC, UL Approved, one switch is fi xed at +10, one is adjustable 10 to 90. Meets culus requirements without the need of an electrical ground connection. ANING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 066_AF(X)UP AFUP, AFUP-S AFXUP, AFUP-S On/Off wiring for AFUP, AFXUP ht lk 067_AF(X)UP-S Auxiliary Switches for AFUP-S, AFXUP-S AFUP-S AFXUP-S 4

AFUP N4(H), AFUP-S N4(H), AFXUP N4, AFXUP-S N4 NEMA 4, On/Off, Spring eturn, 4 to 40 VAC Torque min. 180 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection AFUP... N4 AFUP N4(H), AFUP-S N4(H), AFXUP N4, AFXUP-S N4 4...40 VAC -0% / +10%, 0/60 Hz 4...1 VDC ±10% running 7 / heater holding 3. 7 VA @ 4 VAC (class power source) 8. VA @ 10 VAC / heater VA @10 VAC 18 VA @ 40 VAC 3 ft, 18 GA appliance cable, 1/ conduit connector -S models: Two 3 ft, 18 gauge appliance cables with 1/ conduit connectors heater (N4H) terminal block, 18-16 GA AFXUP... N4 3 ft [1m], 10 ft [3m] or 16 ft [m] 18 GA appliance cable, with or without 1/ conduit connector -S models: Two 3 ft [1m], 10 ft [3m] or 16 ft [m] appliance cables with or without 1/ conduit connectors Overload protection electronic throughout 0 to 9 rotation Control on/off Torque 180 in-lb [0 Nm] minimum Direction of rotation spring reversible with C/CC mounting inside housing Mechanical angle of rotation 9 (adjustable with mechanical end stop, 3 to 9 ) unning time motor < 7 sec spring 0 sec @ -4 F to 1 F [-0 C to 0 C]; < 60 sec @ - F [-30 C] spring (with heater) 0 sec @ -4 F to 1 F [-0 C to 0 C]; < 60 sec @ -49 F [-4 C] Position indication visual indicator, 0 to 9 (0 is full spring return position) Manual override mm hex crank (³ ₁₆" Allen), supplied Humidity max. 9% H non-condensing Ambient temperature - F to 1 F [-30 C to 0 C] with heater -49 F to 1 F [-4 C to 0 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing UL Type 4, NEMA 4, IP66 Housing material polycarbonate Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/9/EC Noise level <0d(A) motor @ 7 seconds 6d(A) spring return Servicing maintenance free Quality standard ISO 9001 eight 9.7 lbs (4.4 kg), 10 lbs (4. kg) with switches 10. lbs (4.8 kg) with heater ated Impulse Voltage 4kV, Type of action 1.AA (1.AA. for -S version), Control Pollution Degree 4. AFUP-S N4(H), AFXUP-S N4 Auxiliary switches x SPDT 3A (0.A) @ 0 VAC, UL Approved one set at +10, one adjustable 10 to 90 Application For On/Off, fail-safe control of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. Control is On/Off from an auxiliary contact, or a manual switch. The actuator is mounted directly to a damper shaft up to 1.0 in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. Operation The AF N4(H) and AFX N4 series actuators provide true spring return operation for reliable fail-safe application and positive close off on air tight dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The AF N4(H) and AFX N4 series provides 9 of rotation and is provided with a graduated position indicator showing 0 to 9. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The AFUP-S N4(H), AFXUP-S N4 versions are provided with two built-in auxiliary switches. These SPDT switches provide safety interfacing or signaling, for example, for fan start-up. The switching function at the fail-safe position is fixed at +10, the other switch function is adjustable between +10 to +90. Dimensions (inches [mm]) Clamp Configurations 1/ Field Selectable 3/4 Centered 1.0 Centered (Default) (Field Selectable) 1.99 [330] 1.17 [9.8] 0.79 [0] 3.6 [9.1] 3.36 [8.] 6.4 [163.9] 0.39 [10] 0.9 [.4] 3. [0.14] 6.77 [17] 0.81 [0.] 9.37 [8] 1.1 [8.] D31_Confi g

AFUP N4(H), AFUP-S N4(H), AFXUP N4, AFXUP-S N4 NEMA 4, On/Off, Spring eturn, 4 to 40 VAC Accessories Tool-06 8mm and 10 mm wrench 4344-00001 Gland (needed for additional wires) 11097-00001 Gasket for Gland (needed for additional wires) NOTE: hen using AFUP N4(H), AFUP-S N4(H), AFXUP N4, AFXUP-S N4 actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to elimo iring Guide. 066_AFUP_N4 Typical Specification On/Off spring return damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a jackshaft up to a 1.0 diameter. The actuators must be designed so that they may be used for either clockwise or counterclockwise fail-safe operation. Actuators shall be protected from overload at all angles of rotation. If required, two SPDT auxiliary switch shall be provided having the capability of one being adjustable. Actuators with auxiliary switches must be constructed to meet the requirements for Double Insulation so an electrical ground is not required to meet agency listings. Actuators shall be culus Approved and have a year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. iring Diagrams On/Off iring ht lk AFUP N4(H) AFUP-S N4(H) AFXUP N4 AFXUP-S N4 067_AFUP-S_N4 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 No ground connection is required. For end position indication, interlock control, fan startup, etc., 4 AFUP-S N4(H), AFXUP-S N4 incorporates two built-in auxiliary switches: x SPDT, 3A (0.A) @0 VAC, UL Approved, one switch is fi xed at +10, one is adjustable 10 to 90. Meets culus requirements without the need of an electrical ground connection. ANING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Auxiliary Switches NEMA 4 Heater AFUP-S N4(H) AFXUP-S N4 AF-NF N4H 10V heater 6

AF4-S, AF4-S-S, AFX4-S, AFX4-S-S Proportional, Spring eturn, 4 V, for to 10 VDC or 4 to 0 ma Control Signal Torque min. 180 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection AF... AFX... Overload protection Operating range Y Input impedance Feedback output U Torque Direction of rotation Mechanical angle of rotation unning time AF4-S, AF4-S-S, AFX4-S, AFX4-S-S 4 VAC ±0%, 0/60 Hz 4 VDC +0% / -10% running. holding 3 8. VA (class power source) 3 ft, 18 GA appliance cable, 1/" conduit connector -S models: two 3 ft, 18 gauge appliance cables with 1/ conduit connectors 3 ft [1m], 10 ft [3m] or 16 ft [m] 18 GA appliance or plenum cables, with or without 1/ conduit connector -S models: Two 3 ft [1m], 10 ft [3m] or 16 ft [m] appliance cables, with or without 1/" conduit connectors electronic throughout 0 to 9 rotation to 10 VDC, 4 to 0mA 100 kω for to 10 VDC (0.1 ma) 00 Ω for 4 to 0 ma to 10 VDC (max. 0. ma) 180 in-lb [0 Nm] minimum spring reversible with C/CC mounting motor reversible with built-in switch 9 (adjustable with mechanical end stop, 3 to 9 ) spring < 0 seconds @ -4 F to 1 F [-0 C to 0 C]; < 60 seconds @ - F [-30 C] motor 9 seconds Position indication visual indicator, 0 to 9 (0 is full spring return position) Manual override mm hex crank (³ ₁₆" Allen), supplied Humidity max. 9% H non-condensing Ambient temperature - F to 1 F [-30 C to 0 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing Nema, IP4, Enclosure Type Housing material zinc coated metal and plastic casing Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/9/EC Noise level 40d(A) motor @ 9 seconds 6d(A) spring return Servicing maintenance free Quality standard ISO 9001 eight 4.6 lbs (.1 kg); 4.9 lbs (. kg) with switches ated Impulse Voltage 800V, Type of action 1.AA (1.AA. for -S version), Control Pollution Degree 3. AF4-S-S, AFX4-S-S Auxiliary switches x SPDT 3A (0.A) @ 0 VAC, UL approved one set at +10, one adjustable 10 to 90 Application For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft up to 1.0 in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The actuator operates in response to a to 10 VDC, or with the addition of a 00Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. A to 10 VDC feedback signal is provided for position indication. Not to be used for a master-slave application. Operation The AF and AFX series actuators provide true spring return operation for reliable failsafe application and positive close-off on air tight dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The AF and AFX series provides 9 of rotation and is provided with a graduated position indicator showing 0 to 9. The AF4-S and AFX4-S uses a brushless DC motor which is controlled by an Application Specific Integrated Circuit (ASIC) and a microprocessor. The microprocessor provides the intelligence to the ASIC to provide a constant rotation rate and to know the actuator s exact fail-safe position. The ASIC monitors and controls the brushless DC motor s rotation and provides a digital rotation sensing function to prevent damage to the actuator in a stall condition. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The AF4-S-S and AFX4-S-S versions are provided with two built-in auxiliary switches. These SPDT switches provide safety interfacing or signaling, for example, for fan start-up. The switching function at the fail-safe position is fixed at +10, the other switch function is adjustable between +10 to +90. The AF4-S, AF4-S-S, AFX4-S and AFX4-S-S actuator is shipped at + ( from full fail-safe) to provide automatic compression against damper gaskets for tight shut-off. ATTENTION: AF4-S(-S) and AFX4-S(-S) cannot be tandem mounted on the same damper or valve shaft. Only On/Off and MFT AF models can be used for tandem mount applications. Dimensions (Inches [mm]) K7- (supplied) 1/" Centered (Default) 3/4" Centered (Field Selectable) 1.0" Centered (Field Selectable) AFNFDim 7

AF4-S, AF4-S-S, AFX4-S, AFX4-S-S Proportional, Spring eturn, 4 V, for to 10 VDC to 4 to 0 ma Control Signal Accessories AV 8- Shaft extension IND-AF Damper position indicator KH-AF Crank arm K7- Universal clamp for up to 1.0 dia jackshafts TF-CC US Conduit fitting Tool-06 8mm and 10 mm wrench ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket ZG-118 Mounting bracket for arber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 100 replacement or new crank arm type installations ZG-AF Crank arm adaptor kit ZG-AF118 Crank arm adaptor kit ZS-100 eather shield (metal) ZS-10 eather shield (polycarbonate) ZS-60 Explosion-proof housing ZS-300 NEMA 4X housing NOTE: hen using AF4-S, AF4-S-S, AFX4-S and AFX4-S-S actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to elimo iring Guide. Typical Specification Spring return control damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a jackshaft up to a 1.0 diameter. The actuator must provide proportional damper control in response to a to 10 VDC or, with the addition of a 00Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. The actuators must be designed so that they may be used for either clockwise or counterclockwise fail-safe operation. Actuators shall use a brushless DC motor controlled by a microprocessor and be protected from overload at all angles of rotation. un time shall be constant, and independent of torque. A to 10 VDC feedback signal shall be provided for position feedback. Actuators shall be culus Approved and have a year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. iring Diagrams ANING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 1 4 VAC Transformer Control Signal ( ) to 10 VDC (+) to 10 VDC control of AF4-S and AFX4-S 4 to 0 ma control of AF4-S and AFX4-S with to 10 VDC feedback output 1 Common 3 + Hot 3 Y 1 Input, to 10V U Output to 10V AF4-S, AF4-S-S AFX4-S, AFX4-S-S AF4-S, AF4-S-S AFX4-S, AFX4-S-S 068_AF(X)4-S 069_AF(X)4-S 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Up to 4 actuators may be connected in parallel if not mechanically mounted to the same shaft. ith 4 actuators wired to one 00 Ω resistor. Power consumption must be observed. 3 Actuator may also be powered by 4 VDC. 4 For end position indication, interlock control, fan startup, etc., AF4-S-S and AFX4-S-S incorporates two built-in auxiliary switches: x SPDT, 3A (0.A) @0 VAC, UL Approved, one switch is fi xed at +10, one is adjustable 10 to 90. Only connect common to neg. ( ) leg of control circuits AF4-S-S AFX4-S-S Auxiliary switches for AF4-S-S, AFX4-S-S 064_AF(X)4_S_-S The ZG-01 00 Ω resistor converts the 4 to 0 ma control signal to to 10 VDC. ATTENTION: AF4-S(-S) and AFX4-S(-S) cannot be tandem mounted on the same damper or valve shaft. Only On/Off and MFT AF models can be used for tandem mount applications. 8

AF4-S N4(H), AF4-S-S N4(H), AFX4-S N4, AFX4-S-S N4 NEMA 4, Proportional, Spring eturn, 4 V, for to 10 VDC or 4 to 0 ma Control Signal Torque min. 180 in-lb, for control of air dampers Technical Data Power supply Power consumption Transformer sizing Electrical connection AF... N4 AF4-S N4(H) AF4-S-S N4(H), AFX4-S N4 AFX4-S-S N4 4 VAC ±0%, 0/60 Hz 4 VDC +0% / -10% running. / heater holding 3 6 VA (class power source) / heater VA 3 ft, 18 GA appliance cable, 1/" conduit connector -S models: two 3 ft, 18 gauge appliance cables with 1/ conduit connectors heater (N4H) terminal block, 6-16 GA AFX... N4 3 ft [1m], 10 ft [3m] or 16 ft [m] 18 GA appliance or plenum cables, with 1/ conduit connector -S models: Two 3 ft [1m], 10 ft [3m] or 16 ft [m] appliance cables with 1/" conduit connectors Overload protection electronic throughout 0 to 9 rotation Operating range Y to 10 VDC, 4 to 0mA Input impedance 100 kω for to 10 VDC (0.1 ma) 00 Ω for 4 to 0 ma Feedback output U to 10 VDC (max. 0. ma) Torque 180 in-lb [10 Nm] minimum Direction of rotation spring reversible with C/CC mounting Inside housing motor reversible with built-in switch Mechanical angle of rotation 9 (adjustable with mechanical end stop, 3 to 9 ) unning time motor 9 seconds spring < 0 seconds @ -4 F to 1 F [-0 C to 0 C]; < 60 seconds @ - F [-30 C] spring (with heater) < 0 seconds @ -4 F to 1 F [-0 C to 0 C]; < 60 seconds @ -49 F [-4 C] Position indication visual indicator, 0 to 9 (0 is full spring return position) Manual override mm hex crank (³ ₁₆" Allen), supplied Humidity max. 9% H non-condensing Ambient temperature - F to 1 F [-30 C to 0 C] with heater -49 F to 1 F [-4 C to 0 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing UL Type 4, NEMA 4, IP66 Housing material polycarbonate Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/9/EC Noise level 40d(A) motor @ 9 seconds 6d(A) spring return Servicing maintenance free Quality standard ISO 9001 eight 9.7 lbs (4 kg); 10 lbs (4. kg) with switches 10. lbs (4.8 kg) ated Impulse Voltage 800V, Type of action 1.AA (1.AA. for -S version), Control Pollution Degree 4. AF4-S-S N4(H), AF4-S-S N4 Auxiliary switches x SPDT 3A (0.A) @ 0 VAC, UL approved one set at +10, one adjustable 10 to 90 Application For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifications. The actuator is mounted directly to a damper shaft up to 1.0 in diameter by means of its universal clamp. A crank arm and several mounting brackets are available for applications where the actuator cannot be direct coupled to the damper shaft. The actuator operates in response to a to 10 VDC, or with the addition of a 00Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. A to 10 VDC feedback signal is provided for position indication. Not to be used for a master-slave application. Operation The AF N4(H), AFX N4 series actuators provide true spring return operation for reliable fail-safe application and positive close-off on air tight dampers. The spring return system provides constant torque to the damper with, and without, power applied to the actuator. The AF N4(H), AFX N4 series provides 9 of rotation and is provided with a graduated position indicator showing 0 to 9. The AF4-S N4(H), AFX4-S N4 uses a brushless DC motor which is controlled by an Application Specific Integrated Circuit (ASIC) and a microprocessor. The microprocessor provides the intelligence to the ASIC to provide a constant rotation rate and to know the actuator s exact fail-safe position. The ASIC monitors and controls the brushless DC motor s rotation and provides a digital rotation sensing function to prevent damage to the actuator in a stall condition. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The AF4-S-S N4(H), AFX4-S-S N4 version are provided with two built-in auxiliary switches. These SPDT switches provide safety interfacing or signaling, for example, for fan start-up. The switching function at the fail-safe position is fixed at +10, the other switch function is adjustable between +10 to +90. ATTENTION: AF4-S(-S) N4(H) and AFX4-S(-S) N4 cannot be tandem mounted on the same damper or valve shaft. Only On/Off and MFT AF models can be used for tandem mount applications. Dimensions (inches [mm]) Clamp Configurations 1/ Field Selectable 3/4 Centered 1.0 Centered (Default) (Field Selectable) 1.99 [330] 1.17 [9.8] 0.79 [0] 3.6 [9.1] 3.36 [8.] 6.4 [163.9] 0.39 [10] 0.9 [.4] 3. [0.14] 6.77 [17] 0.81 [0.] 9.37 [8] 1.1 [8.] D31_Confi g 9

AF4-S N4(H), AF4-S-S N4(H), AFX4-S N4, AFX4-S-S N4 NEMA 4, Proportional, Spring eturn, 4 V, for to 10 VDC or 4 to 0 ma Control Signal Accessories Tool-06 8mm and 10 mm wrench 4344-00001 Gland (needed for additional wires) 11097-00001 Gasket for Gland (needed for additional wires) NOTE: hen using AF4-S N4(H), AF4-S-S N4(H), AFX4-S N4, AFX4-S-S N4 actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to elimo iring Guide. Typical Specification Spring return control damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a jackshaft up to a 1.0 diameter. The actuator must provide proportional damper control in response to a to 10 VDC or, with the addition of a 00Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. The actuators must be designed so that they may be used for either clockwise or counterclockwise fail-safe operation. Actuators shall use a brushless DC motor controlled by a microprocessor and be protected from overload at all angles of rotation. un time shall be constant, and independent of torque. A to 10 VDC feedback signal shall be provided for position feedback. Actuators shall be culus Approved and have a year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. iring Diagrams ANING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 1 Control Signal ( ) to 10 VDC (+) to 10 VDC control 4 VAC Transformer 1 Common 3 + Hot 3 Y 1 Input, to 10V U Output to 10V AF4-S N4(H) AF4-S-S N4(H) AFX4-S N4 AFX4-S-S N4 068_AF4-S_N4 069_AF4-S_N4 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. Up to 4 actuators may be connected in parallel. ith 4 actuators wired to one 00 Ω resistor. Power consumption must be observed. 3 Actuator may also be powered by 4 VDC. 4 For end position indication, interlock control, fan startup, etc., AF4-S-S N4(H), AFX4-S-S N4 incorporates two built-in auxiliary switches: x SPDT, 3A (0.A) @0 VAC, UL Approved, one switch is fi xed at +10, one is adjustable 10 to 90. Only connect common to neg. ( ) leg of control circuits The ZG-01 00 Ω resistor converts the 4 to 0 ma control signal to to 10 VDC. ATTENTION: AF4-S(-S) N4(H) and AFX4-S(-S) N4 cannot be tandem mounted on the same damper or valve shaft. Only On/Off and MFT AF models can be used for tandem mount applications. AF4-S N4(H) AF4-S-S N4(H) AFX4-S N4 AFX4-S-S N4 4 to 0 ma control with to 10 VDC feedback output Auxiliary switches AF4-S-S N4(H) AFX4-S-S N4 064_AF4_S_-S_N4 GK-AF-NF N4H 4V heater NEMA 4 Heater 60

AF4-MFT, AF4-MFT-S, AFX4-MFT, AFX4-MFT-S Proportional, Spring eturn, 4 V, Multi-Function Technology Torque min. 180 in-lb Control to 10 VDC (DEFAULT) Feedback to 10 VDC (DEFAULT) Technical Data AF4-MFT, AF4-MFT-S, AFX4-MFT, AFX4-MFT-S Power supply 4 VAC, +/- 0%, 0/60 Hz 4 VDC, +0% / -10% Power running 7. consumption holding 3 Transformer sizing 10 VA (Class power source) Electrical connection AF... 3 ft, 18 GA appliance cable, 1/" conduit connector -S models: two 3 ft, 18 gauge appliance cables with 1/ conduit connectors AFX... 3 ft [1m], 10 ft [3m] or 16 ft [m] 18 GA appliance or plenum cables, with or without 1/ conduit connector -S models: two 3 ft [1m], 10 ft [3m] or 16 ft [m] appliance cables with or without 1/" conduit connectors Overload protection electronic throughout 0 to 9 rotation Operating range Y* to 10 VDC, 4 to 0 ma (default) variable (VDC, PM, floating point, on/off) Input impedance 100 kω for to 10 VDC (0.1 ma) 00 Ω for 4 to 0 ma 100 Ω for PM, floating point and on/off control Feedback output U* to 10 VDC, 0. ma max Torque minimum 180 in-lb (0 Nm) Direction of spring reversible with cw/ccw mounting rotation* motor reversible with built-in switch Mechanical 9 (adjustable with mechanical end stop, 3 to 9 ) angle of rotation* unning time spring <0 sec @ -4 F to 1 F [-0 C to 0 C]; <60 sec @ - F [-30 C] motor* 10 seconds (default), variable (70 to 0 seconds) Angle of otation off (default) adaptation Override control* min position = 0% mid. position = 0% max. position = 100% Position indication visual indicator, 0 to 9 (0 is spring return position) Manual override mm hex crank (³ ₁₆" Allen), supplied Humidity max. 9% H, non-condensing Ambient temperature - to 1 F (-30 to 0 C) Storage temperature -40 to 176 F (-40 to 80 C) Housing NEMA, IP4, Enclosure Type Housing material zinc coated metal and plastic casing Noise level 40d(A) motor @ 10 seconds, run time dependent 6d(A) spring return Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/9/EC Quality standard ISO 9001 Servicing maintenance free eight 4.6 lbs. (1.9 kg), 4.9 lbs. ( kg) with switch * Variable when configured with MFT options ated Impulse Voltage 800V, Type of action 1.AA (1.AA. for -S version), Control Pollution Degree 3. Programmed for 70 sec motor run time. At 10 sec motor run time, transformer sizing is 8. VA and power consumption is 6 running / 3 holding. Application For proportional modulation of dampers and control valves in HVAC systems. The AF4-MFT, AFX4-MFT provides mechanical spring return operation for reliable failsafe application. Default/Configuration Default parameters for to 10 VDC applications of the AF4-MFT, AFX4-MFT actuator are assigned during manufacturing. If required, custom versions of the actuator can be ordered. The parameters noted in the Technical Data table are variable. These parameters can be changed by three means: Pre-set configurations from elimo Custom configurations from elimo Configurations set by the customer using the MFT PC tool (version 3.4 or higher) software application. Handheld ZTH-GEN Operation The AF4-MFT, AFX4-MFT actuator provides 9 of rotation and is provided with a graduated position indicator showing 0 to 9. The actuator will synchronize the 0 mechanical stop or the physical damper or valve mechanical stop and use this point for its zero position during normal control operations. A unique manual override allows the setting of any actuator position within its 9 of rotation with no power applied. This mechanism can be released physically by the use of a crank supplied with the actuator. hen power is applied the manual override is released and the actuator drives toward the fail-safe position. The actuator uses a brushless DC motor which is controlled by an Application Specific Integrated Circuit (ASIC) and a microprocessor. The microprocessor provides the intelligence to the ASIC to provide a constant rotation rate and to know the actuator s exact position. The ASIC monitors and controls the brushless DC motor s rotation and provides a Digital otation Sensing (DS) function to prevent damage to the actuator in a stall condition. The position feedback signal is generated without the need for mechanical feedback potentiometers using DS. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The AF4-MFT, AFX4-MFT is mounted directly to control shafts up to 1.0" diameter by means of its universal clamp and anti-rotation bracket. A crank arm and several mounting brackets are available for damper applications where the actuator cannot be direct coupled to the damper shaft. The spring return system provides minimum specified torque to the application during a power interruption. The AF4-MFT, AFX4-MFT actuator is shipped at + ( from full fail-safe) to provide automatic compression against damper gaskets for tight shut-off. NOTE: Please see documentation on Multi-Function Technology. Dimensions (Inches [mm]) K7- (supplied) 1/" Centered (Default) 3/4" Centered (Field Selectable) 1.0" Centered (Field Selectable) AFNFDim AF4-MFT-S, AFX4-MFT-S Auxiliary switches x SPDT 3A (0.A) @ 0 VAC, UL approved one set at +10, one adjustable 10 to 90 61

AF4-MFT, AF4-MFT-S, AFX4-MFT, AFX4-MFT-S Proportional, Spring eturn, 4 V, Multi-Function Technology Accessories AV 8- Shaft extension IND-AF Damper position indicator KH-AF Crank arm K7- Universal clamp for up to 1.0 dia jackshafts TF-CC US Conduit fitting Tool-06 8mm and 10 mm wrench ZG-100 Universal mounting bracket ZG-101 Universal mounting bracket ZG-10 Multiple actuator mounting bracket 600_AF_AFX ZG-118 Mounting bracket for arber Colman MA 3../4.., Honeywell Mod III or IV or Johnson Series 100 replacement or new crank arm type installations ZG-AF Crank arm adaptor kit ZG-AF118 Crank arm adaptor kit ZS-100 eather shield (metal) ZS-10 eather shield (polycarbonate) ZS-60 Explosion-proof housing ZS-300 NEMA 4X housing NOTE: hen using AF4-MFT, AF4-MFT-S, AFX4-MFT and AFX4-MFT-S actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to elimo iring Guide. Auxiliary Switches for AF4-MFT-S, AFX4-MFT-S AF4-MFT-S AFX4-MFT-S 399_08 Typical Specification Spring return control damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a jackshaft up to a 1.0 diameter. The actuator must provide proportional damper control in response to a to 10 VDC or, with the addition of a 00Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. The actuators must be designed so that they may be used for either clockwise or counterclockwise fail-safe operation. Actuators shall use a brushless DC motor controlled by a microprocessor and be protected from overload at all angles of rotation. un time shall be constant, and independent of torque. A to 10 VDC feedback signal shall be provided for position feedback. Actuators shall be culus Approved and have a year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. VDC/4-0 ma 399_08 iring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 4 VDC. Position feedback cannot be used with Triac sink controller. 4 The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 4 VAC line. Contact closures A & also can be triacs. 8 A & should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator 9 must be connected to the hot connection of the controller. Meets UL requirements without the need of an electrical ground connection. PM On/Off control 399_08 399_08 The ZG-01 00 Ω resistor may be used. ANING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Floating Point control 6

AF4-MFT N4(H), AF4-MFT-S N4(H), AFX4-MFT N4, AFX4-MFT-S N4 NEMA 4, Proportional, Spring eturn, Direct Coupled, 4V, Multi-Function Technology Torque min. 180 in-lb for control of damper surfaces up to 4 sq ft. Technical Data AF4-MFT N4(H), AF4-MFT-S N4(H), AFX4-MFT N4, AFX4-MFT-S N4 Power supply 4 VAC, +/- 0%, 0/60 Hz 4 VDC, +0% / -10% Power running 7. / heater consumption holding 3 Transformer sizing 10 VA (Class power source) / heater VA Electrical connection AF... N4 3 ft, 18 GA appliance cable, 1/" conduit connector -S models: two 3 ft, 18 gauge appliance cables with 1/ conduit connectors heater (N4H) terminal block, 6-16 GA AFX... N4 3 ft [1m], 10 ft [3m] or 16 ft [m] 18 GA appliance cables, with 1/ conduit connector -S models: two 3 ft [1m], 10 ft [3m] or 16 ft [m] appliance cables with 1/" conduit connectors Overload protection electronic throughout 0 to 9 rotation Operating range Y* to 10 VDC, 4 to 0 ma (default) variable (VDC, PM, floating point, on/off) Input impedance 100 kω for to 10 VDC (0.1 ma) 00 Ω for 4 to 0 ma 100 Ω for PM, floating point and on/off control Feedback output U* to 10 VDC, 0. ma max Torque minimum 180 in-lb (0 Nm) Direction of spring reversible with cw/ccw mounting inside housing rotation* motor reversible with built-in switch Mechanical 9 (adjustable with mechanical end stop, 3 to 9 ) angle of rotation* unning time motor* 10 seconds (default), variable (70 to 0 seconds) spring <0 sec @ -4 F to 1 F [-0 C to 0 C]; <60 sec @ - F [-30 C] spring (with heater) <0 sec @ -4 F to 1 F [-0 C to 0 C]; <60 sec @ -49 F [-4 C] Angle of otation off (default) adaptation Override control* min position = 0% mid. position = 0% max. position = 100% Position indication visual indicator, 0 to 9 (0 is spring return position) Manual override mm hex crank (³ ₁₆" Allen), supplied Humidity max. 9% H non-condensing Ambient temperature - F to 1 F (-30 C to 0 C) with heater -49 F to 1 F (-4 C to 0 C) Storage temperature -40 F to 176 F (-40 C to 80 C) Housing UL Type 4, NEMA 4, IP66 Housing material polycarbonate Noise level 40d(A) motor @ 10 seconds, run time dependent 6d(A) spring return Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/9/EC Quality standard ISO 9001 Servicing maintenance free eight 9.7 lbs. (4.4 kg), 10 lbs. (4. kg) with switches 10. lbs (4.8 kg) with heater * Variable when configured with MFT options ated Impulse Voltage 800V, Type of action 1.AA (1.AA. for -S version), Control Pollution Degree 4. Programmed for 70 sec motor run time. At 10 sec motor run time, transformer sizing is 8. VA and power consumption is 6 running / 3 holding. AF4-MFT-S N4(H), AFX4-MFT-S N4 Auxiliary switches x SPDT 3A (0.A) @ 0 VAC, UL approved one set at +10, one adjustable 10 to 90 63 Application For proportional modulation of dampers in HVAC systems. Actuator sizing should be done in accordance with the damper manufacturer s specifi cations. The actuator is mounted directly to a damper shaft up to 1.0" in diameter by means of its universal clamp. The default parameters for to 10 VDC applications of the MFT actuator are assigned during manufacturing. If necessary, custom versions of the actuators can be ordered. The parameters can be changed by two means: pre-set and custom confi gurations from elimo or on-site confi gurations using the elimo PC-Tool software. Operation The actuator is not provided with and does not require any limit switches, but is electronically protected against overload. The anti-rotation strap supplied with the actuator will prevent lateral movement. The AF4-MFT N4(H), AF4-MFT-S N4(H), AFX4-MFT N4, AFX4-MFT-S N4 provides 9 of rotation and a visual indicator indicates position of the actuator. hen reaching the damper or actuator end position, the actuator automatically stops. The actuator can be manually operated with the manual crank that is supplied after the cover is removed. The AF4-MFT N4(H), AF4-MFT-S N4(H), AFX4-MFT N4, AFX4-MFT-S N4 actuators use a brushless DC motor, which is controlled by an Application Specifi c Integrated Circuit (ASIC). The ASIC monitors and controls the actuator s rotation and provides a digital rotation sensing (DS) function to prevent damage to the actuator in a stall condition.power consumption is reduced in holding mode. Add-on auxiliary switches or feedback potentiometers are easily fastened directly onto the actuator body for signaling and switching functions. Dimensions (inches [mm]) Clamp Configurations 1/ Field Selectable 3/4 Centered 1.0 Centered (Default) (Field Selectable) 1.99 [330] 6.4 [163.9] 0.39 [10] 0.9 [.4] 1.17 [9.8] 0.79 [0] 3.6 [9.1] 3.36 [8.] 3. [0.14] 6.77 [17] 0.81 [0.] 9.37 [8] 1.1 [8.] D31_Confi g

AF4-MFT N4(H), AF4-MFT-S N4(H), AFX4-MFT N4, AFX4-MFT-S N4 NEMA 4, Proportional, Spring eturn, Direct Coupled, 4V, Multi-Function Technology Accessories Tool-06 8mm and 10 mm wrench 4344-00001 Gland (needed for additional wires) 11097-00001 Gasket for Gland (needed for additional wires) NOTE: hen using AF4-MFT N4(H), AF4-MFT-S N4(H), AFX4-MFT N4 and AFX4-MFT-S N4 actuators, only use accessories listed on this page. For actuator wiring information and diagrams, refer to elimo iring Guide. 399_08 Typical Specification Spring return control damper actuators shall be direct coupled type which require no crank arm and linkage and be capable of direct mounting to a jackshaft up to a 1.0 diameter. The actuator must provide proportional damper control in response to a to 10 VDC or, with the addition of a 00Ω resistor, a 4 to 0 ma control input from an electronic controller or positioner. The actuators must be designed so that they may be used for either clockwise or counterclockwise fail-safe operation. Actuators shall use a brushless DC motor controlled by a microprocessor and be protected from overload at all angles of rotation. un time shall be constant, and independent of torque. A to 10 VDC feedback signal shall be provided for position feedback. Actuators shall be culus Approved and have a year warranty, and be manufactured under ISO 9001 International Quality Control Standards. Actuators shall be as manufactured by elimo. VDC/4-0 ma 399_08 iring Diagrams 1 Provide overload protection and disconnect as required. CAUTION Equipment Damage! Actuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. PM 399_08 3 Actuators may also be powered by 4 VDC. 4 8 9 Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 4 VAC line. Contact closures A & also can be triacs. A & should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection of the controller. Meets UL requirements without the need of an electrical ground connection. The ZG-01 00 Ω resistor may be used. ANING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. 600_AF_AFX_N4 On/Off Control Floating Point Control 399_08 GK-AF-NF N4H 4V heater NEMA 4 Heater AF4-MFT-S N4(H) AFX4-MFT-S N4 Auxiliary Switches 64

AF4-MFT9, AFX4-MFT9 Proportional, Spring eturn, 4 V, for Use with Honeywell Electronic Series 90 or a 0 to 13 Ω Input Torque min. 180 in-lb Control fixed, 0 to 13 Ω input, or Honeywell series 90 (fixed) Feedback to 10 VDC (DEFAULT) Technical Data AF4-MFT9, AFX4-MFT9 Power supply 4 VAC, +/- 0%, 0/60 Hz 4 VDC, +0% / -10% Power consumption running 7. holding 3 Transformer sizing 10 VA (Class power source) Electrical connection AF4-MFT9 3 ft, 18 GA plenum cable, with 1/ conduit connector AFX4-MFT9 3 ft [1m], 18 GA plenum cable, with or without 1/ conduit connector Overload protection electronic throughout 0 to 9 rotation Operating range Y 0 to 13 Ω Honeywell Electronic Series 90, 0 to 13 Ω input Feedback output U* to 10 VDC, 0. ma max Torque minimum 180 in-lb (0 Nm) Direction of rotation* spring reversible with cw/ccw mounting motor reversible with built-in switch Mechanical 9 (adjustable with mechanical end stop, 3 to 9 ) angle of rotation* unning time spring <0 seconds @ -4 F to 1 F [-0 C to 0 C]; <60 seconds @ - F [-30 C] motor* 10 seconds (default), variable (70 to 0 seconds) Angle of otation off (default) adaptation Position indication visual indicator, 0 to 9 (0 is spring return position) Manual override mm hex crank (³ ₁₆" Allen), supplied Humidity max. 9% H, non-condensing Ambient temperature - to 1 F (-30 to 0 C) Storage temperature -40 to 176 F (-40 to 80 C) Housing NEMA, IP4, Enclosure Type Housing material zinc coated metal and plastic casing Noise level 40d(A) motor @ 10 seconds, run time dependent 6d(A) spring return Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/9/EC Quality standard ISO 9001 Servicing maintenance free eight 4.6 lbs. (1.9 kg) * Variable when configured with MFT options ated Impulse Voltage 800V, Type of action 1.AA (1.AA. for -S version), Control Pollution Degree 3. Programmed for 70 seconds motor run time. At 10 sec motor run time, transformer sizing is 8. VA and power consumption is 6 running / 3 holding. Application For proportional modulation of dampers and control valves in HVAC systems. The AF4-MFT9, AFX4-MFT9 provides mechanical spring return operation for reliable fail-safe application. Default/Configuration Default parameters for 0 to 13 Ω Input applications of the AF4-MFT9 and AFX4- MFT9 actuator are assigned during manufacturing. If required, custom versions of the actuator can be ordered. However the control input cannot be modified via MFT PC tool software. The parameters noted in the Technical Data table are variable. These parameters can be changed by three means: Pre-set configurations from elimo Custom configurations from elimo Configurations set by the customer using the MFT PC tool (version 3.4 or higher) software application. Operation The AF4-MFT9, AFX4-MFT9 actuator provides 9 of rotation and is provided with a graduated position indicator showing 0 to 9. The actuator will synchronize the 0 mechanical stop or the physical damper or valve mechanical stop and use this point for its zero position during normal control operations. A unique manual override allows the setting of any actuator position within its 9 of rotation with no power applied.this mechanism can be released physically by the use of a crank supplied with the actuator. hen power is applied the manual override is released and the actuator drives toward the fail-safe position. The actuator uses a brushless DC motor which is controlled by an Application Specific Integrated Circuit (ASIC) and a microprocessor. The microprocessor provides the intelligence to the ASIC to provide a constant rotation rate and to know the actuator s exact position. The ASIC monitors and controls the brushless DC motor s rotation and provides a Digital otation Sensing (DS) function to prevent damage to the actuator in a stall condition. The position feedback signal is generated without the need for mechanical feedback potentiometers using DS. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The AF4-MFT9, AFX4-MFT9 is mounted directly to control shafts up to 1.0" diameter by means of its universal clamp and anti-rotation bracket. A crank arm and several mounting brackets are available for damper applications where the actuator cannot be direct coupled to the damper shaft. The spring return system provides minimum specified torque to the application during a power interruption. The AF4- MFT9, AFX4-MFT9 actuator is shipped at + ( from full fail-safe) to provide automatic compression against damper gaskets for tight shut-off. Dimensions (Inches [mm]) K7- (supplied) 1/" Centered (Default) 3/4" Centered (Field Selectable) 1.0" Centered (Field Selectable) AFNFDim 6

AF4-MFT9, AFX4-MFT9 Proportional, Spring eturn, 4 V, for Use with Honeywell Electronic Series 90 or a 0 to 13 Ω Input Proportional Potentiometric Control - iring Diagrams Actuators with plenum rated cable do not have numbers on wires; use color codes instead. Actuators with appliance cables are numbered. Provide overload protection and disconnect as required. ANING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Actuators and controller must have separate transformers. Consult controller instruction data for more detailed information. esistor value depends on the type of controller and the number of actuators. 4 No resistor is used for one actuator. Honeywell resistor kits may also be used. To reverse control rotation, use the reversing switch. ire Colors 1 = lack = ed Override Switch A Switch Damper Position Damper Open Damper Closed The direction of rotation switch is set so that the fail safe position and the position of the damper is closed with no signal at wire. 4 VAC Transformer Low Limit Control Series 90 Controller 4 VAC Transformer 13 Ω A 4 VAC Transformer Controller Series 90 low limit control 13 Ω for 0 to 0% control 80 Ω for 0 to 100% control High Limit Control Series 90 Controller 3 = hite 4 = Pink 4 VAC Transformer Series 90 high limit control - 80 Ω A = Gray 6 = Orange lk (1) Common ed () + Hot Pnk (4) 4 ht (3) Gry () -MFT9 lk (1) Common ed () + Hot Pnk (4) 4 ht (3) Gry () -MFT9 lk (1) Common ed () + Hot Pnk (4) 4 ht (3) Gry () -MFT9 lk (1) Common ed () + Hot Pnk (4) 4 ht (3) Gry () -MFT9 01 016 017 iring Multiple Actuators to a Series 90 Controller 4 VAC Transformer Shunting esistor 4 Series 90 Controller No. of actuators esistance 140 Ω 3 71. Ω 4 47. Ω 37. Ω 6 8 Ω esistor Kit No. ZG-03 To other actuators lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 iring Multiple Actuators to a Series 90 Controller using a Minimum Position Potentiometer Series 90 Controller 4 Shunting esistor 4 VAC Transformer H0 Changeover Occupied Controller Contact To other actuators S963A Minimum Position Potentiometer lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 018 019 Typical wiring diagrams for multiple actuators used with the 973, 7100 and T77 controllers 4 H0 Changeover Controller Shunting esistor 4 VAC Transformer No. of actuators esistance 1300 Ω 3 910 Ω 4 768 Ω esistor Kit No. ZG-06 4 Shunting esistor 973, 7100 Controller Y 973, 7100 T77 Q09A Minimum Position Potentiometer To other actuators To other actuators lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 Occupied Contact Honeywell T67A Morning armup lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () Honeywell Q09A Minimum Position Potentiometer -MFT9 Used with the 973 and 7100 controllers 4 VAC Transformer Honeywell T67A Morning armup lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 00 66

AF4-MFT9 N4(H), AFX4-MFT9 N4 NEMA 4, Proportional, Spring eturn, 4 V, for Use with Honeywell Electronic Series 90 or a 0 to 13 Ω Input Torque min. 180 in-lb Control fixed, 0 to 13 Ω input, or Honeywell series 90 (fixed) Feedback to 10 VDC (DEFAULT) Technical Data AF4-MFT9 N4(H), AFX4-MFT9 N4 Power supply 4 VAC, +/- 0%, 0/60 Hz 4 VDC, +0% / -10% Power running 7. / heater consumption holding 3 Transformer sizing 10 VA (Class power source) / heater VA Electrical connection AF4-MFT9 N4 3 ft, 18 GA plenum cable, with 1/ conduit connector heater (N4H) terminal block, 6-16 GA AFX4-MFT9 N4 3 ft [1m], 18 GA plenum cable, with 1/ conduit connector Overload protection electronic throughout 0 to 9 rotation Operating range Y 0 to 13 Ω Honeywell Electronic Series 90, 0 to 13 Ω input Feedback output U* to 10 VDC, 0. ma max Torque minimum 180 in-lb (0 Nm) Direction spring reversible with cw/ccw mounting inside housing of rotation* motor reversible with built-in switch Mechanical 9 (adjustable with mechanical end stop, 3 to 9 ) angle of rotation* unning time motor* 10 seconds (default), variable (70 to 0 seconds) spring <0 seconds @ -4 F to 1 F [-0 C to 0 C]; <60 seconds @ - F [-30 C] spring (with heater) <0 seconds @ -4 F to 1 F [-0 C to 0 C]; <60 seconds @ -49 F [-4 C] Angle of rotation off (default) adaptation Position indication visual indicator, 0 to 9 (0 is spring return position) Manual override mm hex crank (³ ₁₆" Allen), supplied Humidity max. 9% H non-condensing Ambient temperature - F to 1 F [-30 C to 0 C] with heater -49 F to 1 F [-4 C to 0 C] Storage temperature -40 F to 176 F [-40 C to 80 C] Housing UL Type 4, NEMA 4, IP66 Housing material polycarbonate Noise level 40d(A) motor @ 10 seconds, run time dependent 6d(A) spring return Agency listings culus acc. to UL60730-1A/--14, CAN/CSA E60730-1:0, CE acc. to 004/108/EC & 006/9/EC Quality standard ISO 9001 Servicing maintenance free eight 9.7 lbs. (4.4 kg); 10. lbs (4.8 kg) with heater * Variable when configured with MFT options ated Impulse Voltage 800V, Type of action 1.AA (1.AA. for -S version), Control Pollution Degree 4. Programmed for 70 seconds motor run time. At 10 sec motor run time, transformer sizing is 8. VA and power consumption is 6 running / 3 holding. Application For proportional modulation of dampers and control valves in HVAC systems. The AF4-MFT9 N4(H), AFX4-MFT9 N4 provides mechanical spring return operation for reliable fail-safe application. Default/Configuration Default parameters for 0 to 13 Ω Input applications of the AF4-MFT9 N4(H) and AFX4-MFT9 N4 actuator are assigned during manufacturing. If required, custom versions of the actuator can be ordered. However the control input cannot be modified via MFT PC tool software. The parameters noted in the Technical Data table are variable. These parameters can be changed by three means: Pre-set configurations from elimo Custom configurations from elimo Configurations set by the customer using the MFT PC tool (version 3.4 or higher) software application. Operation The AF4-MFT9 N4(H), AFX4-MFT9 N4 actuator provides 9 of rotation and is provided with a graduated position indicator showing 0 to 9. The actuator will synchronize the 0 mechanical stop or the physical damper or valve mechanical stop and use this point for its zero position during normal control operations. A unique manual override allows the setting of any actuator position within its 9 of rotation with no power applied.this mechanism can be released physically by the use of a crank supplied with the actuator. hen power is applied the manual override is released and the actuator drives toward the fail-safe position. The actuator uses a brushless DC motor which is controlled by an Application Specific Integrated Circuit (ASIC) and a microprocessor. The microprocessor provides the intelligence to the ASIC to provide a constant rotation rate and to know the actuator s exact position. The ASIC monitors and controls the brushless DC motor s rotation and provides a Digital otation Sensing (DS) function to prevent damage to the actuator in a stall condition. The position feedback signal is generated without the need for mechanical feedback potentiometers using DS. The actuator may be stalled anywhere in its normal rotation without the need of mechanical end switches. The AF4-MFT9 N4(H), AFX4-MFT9 N4 is mounted directly to control shafts up to 1.0 diameter by means of its universal clamp and anti-rotation bracket. A crank arm and several mounting brackets are available for damper applications where the actuator cannot be direct coupled to the damper shaft. The spring return system provides minimum specified torque to the application during a power interruption. Dimensions (inches [mm]) Clamp Configurations 1/ Field Selectable 3/4 Centered 1.0 Centered (Default) (Field Selectable) 1.99 [330] 1.17 [9.8] 0.79 [0] 3.6 [9.1] 6.4 [163.9] 0.39 [10] 0.9 [.4] 3. [0.14] 0.81 [0.] 6.77 [17] D31_confi g 3.36 [8.] 9.37 [8] 1.1 [8.] 67

AF4-MFT9 N4(H), AFX4-MFT9 N4 NEMA 4, Proportional, Spring eturn, 4 V, for Use with Honeywell Electronic Series 90 or a 0 to 13 Ω Input Proportional Potentiometric Control - iring Diagrams Actuators with plenum rated cable do not have numbers on wires; use color codes instead. Actuators with appliance cables are numbered. Provide overload protection and disconnect as required. ANING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Actuators and controller must have separate transformers. Consult controller instruction data for more detailed information. esistor value depends on the type of controller and the number of actuators. 4 No resistor is used for one actuator. Honeywell resistor kits may also be used. To reverse control rotation, use the reversing switch. ire Colors 1 = lack = ed Override Switch A Switch Damper Position Damper Open Damper Closed The direction of rotation switch is set so that the fail safe position and the position of the damper is closed with no signal at wire. 4 VAC Transformer Low Limit Control Series 90 Controller 4 VAC Transformer 13 Ω A 4 VAC Transformer Controller Series 90 low limit control 13 Ω for 0 to 0% control 80 Ω for 0 to 100% control High Limit Control Series 90 Controller 3 = hite 4 = Pink 4 VAC Transformer Series 90 high limit control - 80 Ω A = Gray 6 = Orange lk (1) Common ed () + Hot Pnk (4) 4 ht (3) Gry () -MFT9 N4 lk (1) Common ed () + Hot Pnk (4) 4 ht (3) Gry () -MFT9 N4 lk (1) Common ed () + Hot Pnk (4) 4 ht (3) Gry () -MFT9 N4 lk (1) Common ed () + Hot Pnk (4) 4 ht (3) Gry () -MFT9 N4 01 016 017 iring Multiple Actuators to a Series 90 Controller 4 VAC Transformer Shunting esistor 4 Series 90 Controller No. of actuators esistance 140 Ω 3 71. Ω 4 47. Ω 37. Ω 6 8 Ω esistor Kit No. ZG-03 To other actuators lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 N4 lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 N4 iring Multiple Actuators to a Series 90 Controller using a Minimum Position Potentiometer 4 VAC Transformer Series 90 Controller Shunting esistor 4 H0 Changeover Occupied Controller Contact To other actuators S963A Minimum Position Potentiometer lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 N4 lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 N4 018 019 Typical wiring diagrams for multiple actuators used with the 973, 7100 and T77 controllers 4 H0 Changeover Controller Shunting esistor 4 VAC Transformer No. of actuators esistance 1300 Ω 3 910 Ω 4 768 Ω esistor Kit No. ZG-06 4 Shunting esistor 973, 7100 Controller Y 973, 7100 T77 Q09A Minimum Position Potentiometer To other actuators To other actuators lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 N4 Occupied Contact Honeywell T67A Morning armup lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () Honeywell Q09A Minimum Position Potentiometer -MFT9 N4 Used with the 973 and 7100 controllers 4 VAC Transformer Honeywell T67A Morning armup lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 N4 lk (1) Common ed () + Hot Pnk (4) ht (3) Gry () -MFT9 N4 00 68

Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. otate the damper to its fail-safe position. If the shaft rotates counterclockwise, mount the CC side of the actuator out. If it rotates clockwise, mount the actuator with the C side out.. If the universal clamp is not on the correct side of the actuator, mount it onto the correct side. 3. Slide the actuator onto the shaft and tighten the nuts on the V-bolt with a 10mm wrench to 6-8 ft-lb of torque. 4. Slide the anti-rotation strap under the actuator so that it engages the slot at the base of the actuator. Secure the strap to the duct work with #8 self-tapping screws. NOTE: ead the Standard Mounting instructions, on the next page, for more detailed information. Dimensions (Inches [mm]) min. 3 1/ [90] min. 3/4 [0] CC CC CC CC C C 1/4" [6.3 mm] 3... 9 9 CC C..8 C C 1/4" [6.3 mm] 1/4" [6.3 mm] 1/4" [6.3 mm] 69

Installation Instructions K7- Universal Clamp 1 70