GENIE CLIP - TYPE RST Resilient Sound Isolation Clip INSTALLATION INSTRUCTIONS

Similar documents
Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

PANELIZED HOME INSTALLATION GUIDELINE

Rockwool Flexi Insulation Application Guide

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

H-Stud Area Separation Wall System

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

PART 1 GENERAL 1.1 SECTION INCLUDES

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

Lightweight Partition Design for Residential and Commercial Buildings

Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

DE Frame with C Series Sidelight

FireWall. High performance fireresistant. FireWall.

CRASH RAIL INSTALLATION HEIGHT

Design No. U419 BXUV.U419 Fire Resistance Ratings ANSI/UL 263 "Reprinted from the Online Certifications Directory with permission from UL"

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Window Installation Instructions

Gypsum Board Systems Manual

GYPSUM AREA SEPARATION FIREWALLS GA

ILLUSION FRAMELESS SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

WINDOW PANNING AND TRIMS

INSTALLATION OF A BAY WINDOW

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

Guidelines for Earthquake Bracing of Residential Water Heaters

DETAILED INSTALLATION GUIDE

Clad Direct Glaze Window Installation Instructions

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

How to Install GoBoard:

Fire Barrier Duct Wrap 15A

NATIONAL INSTITUTE OF BIOLOGICALS

March 14, Installation of Bay, Bow and Garden Windows

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Eucaboard / Eucaplac/ Eucatile paneling is intended for dry interior use only and requires care in handling.

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

Sliding Door Hardware Installation Instructions

CertainTeed. For Shaftwalls SHAFTLINER

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

Composite Panel Firewall Systems

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

CertainTeed. Shaftliner For A rea Separation Firewalls

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No.

INSTALLATION INSTRUCTIONS

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

POST AND FRAME STRUCTURES (Pole Barns)

Packaged Terminal Air Conditioner Wall Sleeve Installation

GYPSUM BOARD AND PLASTER

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia Fax:

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

Seismic Installation for Attic Storage System

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

CPA Steel Stud Framing Page 1 of 11

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

BUILD A CARPORT. 2 - Planning the carport. 3 - Designing the carport

Guidelines for Earthquake Bracing Residential Water Heaters

Installation Guide. Bath and Wall Surrounds SERIES B

PASSIVE FIRE PROTECTION SYSTEMS Application & Technical Manual: Ceilings & Floors

Manual lifting and handling

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

Uncovered Decks & Porches

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

Energy Company Obligation (ECO): Technical Monitoring Questions

Mark Cramer Inspection Services, Inc.

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Typical Finished Basement Details

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

Partitioning & Ceiling Product Information

Superform Products Ltd.

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

SMALL SCALE ASTM E 119/UL 263 ONE HOUR FIRE TESTING FOR MARINOWARE ON JOIST-RITE WITH ARMOROC FLOOR VTEC # TESTED: MAY 23, 2008 REVISION

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

The WANZ Guide to Window Installation

Beadboard Wall Bookcase

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

application instructions

Introduction...COMB-2 Design Considerations and Examples...COMB-3

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Assembly Instructions

Hollow or Cinder Block Wall Mount Job Aid

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

WOODWORKS Linear. Assembly and Installation Instructions 1. GENERAL

Residential Deck Safety, Construction, and Repair

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Wood-frame Construction, Fire Resistance and Sound Transmission

Samuel Shorty Bunk Bed

2.9 WINDOW & DOOR BUCKS

Owner's Manual & Assembly Instructions

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Multi-layer Insulation Blanket for Roofs

Discipline: Structural Issued

39HQ Airovision Air Handling Units

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

Fire Resistance of Brick Masonry

AMF112 ( <00>) 13mm (1/2 in.)

Transcription:

GENIE CLIP - TYPE RST Resilient Sound Isolation Clip INSTALLATION INSTRUCTIONS NOTE If at any time there is a question or concern as to the installation methods please contact Sound Service (Oxford) Ltd. GENIE CLIP TYPE RST SPECIFICATIONS Width..1-5 / 8 (41.6 mm) Height..1 ( 25 mm) Length..2-1 / 2 ( 64.1 mm) Weight...1.25 oz. (40 grams) Max Spacing on Top Hat Channel.48 in. on center Max Acoustic Design Load.. 36 lbs (16 kilo) Plasterboard Steel Channel Specifications (Hat Channel) Gage minimum... 25g. With hemmed edges Width min at base.....2.5 (63.5 mm) Width recommended at base..2.75 (70 mm) Width at top...1.25 (32 mm) Height standard.7.8 (22 mm) Max Clip Spacing on Top Hat Channel..48 in. on center Max Acoustic Design Load per clip.. 36 lbs (16 kilo) NOTE Splice steel channel with 6 (150 mm) overlaps in mid span between clips. Secure with 18g. Wire or (2) two 7/16 framing screws. IMPORTANT!!! Top Hat Channels MUST have hemmed edges Fasteners for Wood Steel or Concrete wood wood steel concrete Wood Wood #8 x 2-1/2 Course Threads, or # 8 x 2-1/2 Course thread Self-drilling screws Steel #8, #10 or #12 1-5/8 Self Tapping, fine thread, Type S Concrete 3/16 or ¼ x 2-1/4 long Anchors Screws NOTES Use fasteners that will have a minimum of 120 lbs pull out or shear strength in the wood, steel or concrete substrate. Tighten fasteners until they come into solid contact with the top washer on the Genie Clip. For best acoustic results DO NOT OVER TIGHTEN EST. 1969 Crawley Mill, Dry Lane, Witney, Oxfordshire, OX29 9TJ Tel : 0845 363 7131 sales@soundservice.co.uk VAT NO: GB 434 5018 73 REG NO: 960986 Fax : 01993 779569

NOTES One and Two Layers of 5/8 Drywall Genie Sound Isolation Clips shall not exceed 48 on centres. (horizontal) Spacing between the steel channels (hat channel) shall not exceed 24. Steel channels are installed perpendicular to the floor. Fasten the Sound Isolation Clips to the substrate with a fastener approved for a minimum pull out and shear of 120 lbs. Tighten fasteners until they come into solid contact with the top washer on the Genie Clip. For best acoustic results DO NOT OVER TIGHTEN Locate the bottom row of steel channel within 3 to 6 of the floor and install in a pattern roughly as per drawing below. Locate the top row of steel channel within 6 of the ceiling. Install all other rows of steel channel ensuring imum spacing between rows does not exceed 24 Add additional short rows of steel channel and clips to pick up plasterboard edges around doors and windows as needed. Snap steel channel into the Genie Clips and make joins between clips with a 6 overlap. Secure with 18g. wire or 2 7 / 16 framing screws. IMPORTANT Before any plasterboard is applied place ¼ to 3 / 8 shims on floor to fully support plasterboard. Install plasterboard (drywall) from the bottom up leaving ¼ spacing (min) around total perimeter. ONLY remove the shims after ALL plasterboard is installed and screwed to ALL top hat channels. Ensure that every screw is installed according to assembly design in each layer of plaster board. Shims are critical for best acoustic results. NOTE It is impossible to short out the Genie Clip System. Should the installer hit a clip location, they will not be able to seat the screw. They will be forced to move left or right on the track away from the Genie Clip. For best acoustic results, if there is more than one layer of plaster board, joints should be staggered. ONLY when plasterboard application is complete with all required screws can the shims be removed. Seal around the entire perimeter of the plasterboard wall filling the gaps with non hardening, intumescent acoustic sealant. Do not install sealant so that it is proud of the plasterboard surface. After sealant has set, tape and finish as usual.

CEILING INSTALLATION GUIDE NOTES One and Two Layers of 5/8 Acoustic Plasterboard Genie Sound Isolation Clips shall not exceed 48 on center. (horizontal) Spacing between the steel channels (hat channel) shall not exceed 24. Steel channels are installed perpendicular to the joists. Fasten the Sound Isolation Clips to the substrate with a fastener approved for a minimum pull out and shear of 120 lbs. Tighten fasteners until they come into solid contact with the top washer on the Genie Clip. For best acoustic results DO NOT OVER TIGHTEN Locate the first row of steel channel within 3 to 6 of the wall edge and install in a pattern roughly as per drawing below. Locate the last of top hat channel within 3 to 6 of the opposite wall. Install all other rows of top hat channel ensuring imum spacing between rows does not exceed 24. IMPORTANT NOTE If the cavity is to have AMW type acoustic mineral wool infill some codes require that steel members not exceed 16 on centers. Check with local building and fire codes. Top hat channels shall not be cantilevered more than 6 beyond the last sound control clip. Snap steel channel into the Genie Clips and make joins between clips with a 6 overlap. Secure with 18g. wire or 2 7 / 16 framing screws. For best acoustic results if there is more than one layer of plasterboard, joints should be staggered. Seal around the entire perimeter of the plasterboard wall filling the gaps with non hardening, intumescent acoustic sealant. Do not install sealant so that it is proud of the gypsum board surface After acoustic sealant has set, tape and finish as usual. General Information It is advised that heavy point loads such as cabinets or book shelves are not fitted to GenieClip supported walls. Resilient Sound Isolation Clips and high density acoustic plasterboard shall The steel channel must have hemmed edge. Splice steel channel in mid span between clips with 6 overlap, securing with 18g. wire or 2-7/16 framing screws. For best acoustic results seal all potential air leaks with non-hardening acoustic sealant. Use fire rated sealant where required. Resilient putty pads should be used to seal back of outlet boxes along with acoustic sealant. WALL AND CEILING INSTALLATION GUIDE Steel studs shall be a minimum of 20g.

FOR WOOD OR STEEL FRAMING with Channels on 24 centers Wall or Ceiling Framing at 24 o.c. Genie Clips at 48 o.c., channels at 24 o.c. 1 or 2 Layers of 5/8 Plasterboard Framing Member Standard 7/8 high Steel Channel (Hat Track) 24 Genie Clip Locations 48 24 WALL Wall AND or CEILING Ceiling Framing INSTALLATION at 16 o.c. 16 GUIDE Genie Clips at 48 o.c., channels at 24 o.c. 1 or 2 Layers of 5/8 Plasterboard Framing Member Standard 7/8 high Steel Channel (Hat Track) 24 Genie Clip Locations 48 16

WALL AND CEILING INSTALLATION GUIDE FOR WOOD OR STEEL FRAMING with Channels on 16 centers NOTE: For when code dictates steel channel must be on 16 centers or when loading with 3 layers of plasterboard

ESTIMATED GENIE CLIP USAGE CHART FOR WALLS AND CEILINGS STEEL OR WOOD FRAMING (CLIPS SPACED 48 o.c. FURRING 24 o.c.) FOR ONE OR TWO LAYERS OF 5/8 ACOUSTIC PLASTERBOARD 1~4 5~8 9~12 13~16 17~20 21~24 25~28 29~32 33~36 37~40 1~3 4pcs 6 8 10 12 14 16 18 20 22 3~5 6 9 12 15 18 21 24 27 30 33 5~7 8 12 16 20 24 28 32 36 40 44 7~9 10 15 20 25 30 35 40 45 50 55 9~11 12 18 24 30 36 42 48 54 60 66 11~13 14 21 28 35 42 49 56 63 70 77 13~15 16 24 32 40 48 56 64 72 80 88 15~17 18 27 36 45 54 63 72 81 90 99 17~19 20 30 40 50 60 70 80 90 100 110 19~21 22 33 44 55 66 77 88 99 110 121 21~23 24 36 48 60 72 84 96 108 120 132 23~25 26 39 52 65 78 91 104 117 130 143 25~27 28 42 56 70 84 98 112 126 140 154 27~29 30 45 60 75 90 105 120 135 150 165 29~31 32 48 64 80 96 112 128 144 160 176 31~33 34 51 68 85 102 119 136 153 170 187 33~35 36 54 72 90 108 126 144 162 180 198 35~37 38 57 76 95 114 133 152 171 190 209 37~39 40 60 80 100 120 140 160 180 500 220 39~41 42 96 84 105 126 147 168 189 210 231 PLEASE NOTE For fire rated assemblies please add 4 Genie Clips and steel top hat channel for each plasterboard butt joint. Check local compliances against fire resistive design specifications. It is always best to have a few extra Genie Clips on hand for non-standard room configurations and to fit around windows, doors, bulkheads etc.