9800 Installation and User Guide

Similar documents
9452/9453 Installation and User Guide

500r+ Installation and User Guide

9448 Installation and User Guide

TS510 & TS500. Installation & User Guide. Compatible Equipment

ACTIVE 5 ENGINEERING MANUAL

HARDWIRED CONTROL PANELS

ACP10 10 Zone Intruder Alarm System

9x5x PROGRAMMING GUIDE

IMPORTANT USER INFORMATION

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

CONTENTS 4. HOW TO UNSET THE PANEL...7

USER GUIDE HARDWIRED CONTROL UNIT

Intruder alarm system Engineering Information

INSTALLATION AND PROGRAMMING GUIDE HARDWIRED CONTROL PANEL

Microprocessor Intruder Alarm System User Guide

INSTALLATION MANUAL CONTENTS

SECURIT 800L+ CONTROL PANEL

ALARM SYSTEM USER GUIDE

Accenta/Optima. Engineer s Manual. Honeywell Security. 8SP399A - Accenta mini panel with remote LCD keypad and communicator outputs.

Intruder alarm system Engineering Information

Programming & Installation PIEZO WARNING. EN : 2009 EN : 2008 EN : 2005 Security Grade 2 Environmental Class II RINS1347-2

Master User Guide Premier Elite Series

TS590. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT 0 ESC

FIREDEX Conventional Fire Panels

How To Set A Timer On A Gg System

User s Information Guide R1A

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

User.QXD 09/05/00 14:47 Page 1 Gardtec /582 User Instructions

Master User Guide Premier Elite 24/48/88/168/640

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panels. Issue 12

SECURIT 800L+ CONTROL PANEL

Control/Communicator Installation Manual

Using your LED Plus keypad

Galaxy 2 Series. User Guide. Honeywell Security

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication

Security System User Guide

SECTION DETECTION AND ALARM

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

Matrix 424/832/832+ ICON & LCD User Manual. Software Version 5 RINS EN Security Grade 2 Environmental Class 2

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

AC-115 Compact Networked Single Door Controller. Installation and User Manual

PRT3 Printer Module: ASCII Protocol Programming Instructions

Solution 862 Operators Manual. Issue 1.00

User Guide Premier Elite 24/48/88/168/640

SCORPION. micron security products

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

ICP-CC488. Installation Guide ICP-CC488 Control Panel

User Guide Veritas 8/Veritas 8Compact/Veritas R8 INS036-5

Ademco Vista-20P/First Alert FA-168C Basic Commands

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

Users Guide to Keypad Functions

How To Program An Autodialer

IDS X-Series User Manual D Issued July 2012

!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40

NetworX Series. NX-216E Zone Expander Module Installation and Startup

THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL. Security Control Panels with Integrated Communicator. Issue 6

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

Diamond + User Manual. Wireless Alarm System. Default codes: User code: 1234 Master Manager Code: 2222

INSTALLATION MANUAL PC2525. Version 1.1

Solution-16 Operators Manual ISSUE 1.60

How To Control A Car Alarm On A Car With A Remote Control System

NetworX NX-6V2. LED Keypad User Manual

MATRIX 6/816. Control Panel with Remote Keypads Software Version 1.34 USER MANUAL RINS545-7

i 70 Installation Manual V1.04 Contents Grade 2 Wireless Intruder Alarm System YOUR SECURITY IS OUR PRIORITY Installation Instructions 2

Secure Keypads for access control

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Intruder alarm system Operating Instructions

Security System. User Guide for the LED Command Center

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

Security System Installation and Programming Guide

PX Control Panel. User Manual. Issue C

tattletale User Guide Consumer unit version P a g e

Scantronic Leading the way in security

ICP-CC404 ICP-CC404 EN. Control Panel. User s Guide

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

UNSET TAMPER FINAL EXIT

SECURITY SYSTEM NOTES

Master User Guide Premier 24/48/88/168. Issue 6

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

SECURITY SYSTEM NOTES

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

astec Integrated Alarm System USER GUIDE

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

SCORPION Z16040C Alarm Controller User Instructions

D200+ Auto-Dialler Installation/Operators Manual

Microprocessor Home Security System

User Guide. RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up

EC-P8 Security System

EURO User Manual. Castle Care-Tech 2012 (RINS1531) Issue 2. Page 1

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Digital Keypad Use s Manual

SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T.

Solution 880 Operators Manual ISSUE 1.10

P/N Rev D

616, 626, 636 & 646 Keypads

System Introduction S E C T I O N 1

LW A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

Intelligent GSM Auto-Dial Alarm System

Transcription:

9800 Installation and User Guide Compatible Equipment 9825 Remote Keypad 9827 Remote Keypad 9040 Internal loudspeaker (16 Ohm). 2 max, fit at least one. 9056 Plug-on Digital Communicator 9076-01/02 Signalling Relay Interface 960 Speech/Digital Communicator 9066 Self-Activating Bell (SAB) Module 496334 Issue 1 1 of 14

9800 Introduction The 9800 Alarm Control Panel comprises a control unit in a shielded case, and up to four separate keypads. The control unit provides: Connections for up to eight Closed Circuit zones. Connections for four outputs (external sounder, strobe, and two fully programmable outputs). Connections for up to four 9825 Keypads. Pins for fitting a plug-on communication device. Any device that complies with the Scantronic plug-on footprint can be fitted. Internal sounder loudspeaker output with electronically generated Chime, Alarm and Fire tones. The programming interface is arranged as a set of two-digit numbered commands. The system can provide for up to 4 separate users. User facilities include: Three different security levels (full set and two part sets) which can be programmed by the installer. User programmable Duress code. Keyswitch setting/unsetting. Technical Specifications General Operating temperature = -10 C to + 40 C. Humidity = Up to 80% non-condensing. Dimensions = h x w x d 300 x 300 x 75 mm. Weight = 4.85 Kg (excl battery). Standby Battery = 12 Volt, 6.0Ah rechargeable lead-acid, Gel Type battery. Power Supply The total current available from the control unit is as follows: System output current = 800mA (Ambient Temp. 20 C). Control unit pcb = 60mA quiescent. = 500mA active (when driving standard external bell). Each 9825 Remote Keypad = 20mA quiescent. = 60mA active. 2 of 14 496334 Issue 1

9800 9825 Keypad Addressing Standard 9066 SAB Module = 40mA. Plug-on 9056 Communicator = 40mA. Keypad Wiring Recommended maximum distances for the remote keypads from the control unit, using standard alarm cable is 100 metres for the star configuration. Outputs OP1, OP2, Bell, Strobe = 500mA. Transistorised outputs capable of driving a relay. 9825 Keypad Addressing Before connecting the keypad(s) to the system, the engineer must set the address of each keypad. Each keypad in a system must have a different address number to ensure that the control unit can correctly identify them. To set the address: 1. Ensure the system is powered down. 2. Open the keypad and identify the four position DIP switch on the keypad pcb, see Figure 1 below. Note that each switch is numbered 1 to 4. The numbers correspond to the keypad address. Figure 1. Keypad Address Switch 3. Select one switch and move it to the ON position (up). Make sure all the other switches are OFF (down). The keypad now has the address given by the switch that is ON. Adjusting Keypad Sounder Volume You can alter the volume of the keypad sounder by adjusting the potentiometer located next to the sounder. See Figure 1. When first installing the keypad set the potentiometer midway using a small screwdriver. 496334 Issue 1 3 of 14

9800 Wiring Figure 2 shows the main connector on the control unit PCB. Subsequent sections describe how to wire keypads and closed circuit zones. Figure 2. Main Connector 4 of 14 496334 Issue 1

9800 Wiring Keypads Wiring Keypads All keypads must be connected to Keypad terminals on the control unit PCB or "daisy chained" to other keypads. Figure 3 shows the connections for each keypad using the 9285 as an example: Figure 3. Wiring the 9285 Keypad Note: The output for the lock release interface must be a transistorised type. A recommended type is RS Components 349-254. A SEPARATE 12 Volt DC supply is required. Contact rating is 10 A. Caution: Do not connect other devices (for example SAB, speakers and so on) in the same cable as the remote keypad wiring. 496334 Issue 1 5 of 14

Wiring Keyswitches 9800 Wiring Keyswitches Connect a keyswitch to the I/P and 0V terminals of the nearest keypad (see Figure 4). Make sure you use a two position, unbiased keyswitch. Communications Figure 4. Keyswitch The control unit can be fitted with communicators that conform to the standard Scantronic plug-on communicator footprint (for example, the 9056 and 9058 Plug-on Digital Communicators, a 960 Speech/Digital Communicator, or a Plug-on Red Care Transmitter). For communicators that do not conform the 9076-01 and 9076-02 can be used as interfaces to the system. 6 of 14 496334 Issue 1

9800 Initial Power Up Programming When all wiring is complete, power up the system for the first time as follows: 1. Ensure that the keypad(s) and detectors are securely fitted and their tamper switches closed. 2. Connect the battery and then close the case. 3. Switch on the mains power. Ignore any tones from the internal and keypad sounders. 4. Go to a keypad and key in 1234. 5. Key in 0 followed by 7890 (the default Engineer s code). The keypad gives an intermittent tone. 6. Open the end station lid. (If the lid is already open, close and open the tamper switch.) The displays shows E (engineer). You are now in programming mode. Programming Commands When delivered from the factory the control unit already has default program settings. To change the default programming you must be in programming mode. Then: 1. Key in the appropriate command number. The display shows the current value of the command. 2. Key in digits to select the value you require. The display shows a code giving the new value. 3. Press Clear to store the new value of the command. If at any time you change your mind, repeat step 1 to 3. The table on the following pages shows the commands and their options. ( A y next to a command value shows that it is the factory default.) The factory default access codes are: Engineer Code 7890 Access Code User 1 1234 Access Code 2 to 4 AAAA (inactive) Access Code 3 BBBB (inactive) Access Code 4 CCCC (inactive) Duress Code OMIT, OMIT, OMIT, OMIT (inactive) Note: The factory default Access Codes 02 to 04 and the Duress Code must be changed by USER 1 to a four digit number to activate them. 496334 Issue 1 7 of 14

Engineer Program Commands 9800 Engineer Program Commands To change: Key-in: Notes Default Zone n 0n x y n = zone number 01 to 08 x = Zone type, one of: 0 = nu (not used) y 1 = PA (panic alarm) 2 = Fr (fire zone) 3 = Al (normal alarm) 4 = 24 (24 hour zone) 5 = FE (final exit) 6 = ER (entry route) y = Zone attributes, any of: 7 = ch (chime) 8 = St (soak test) 9 = 2A (double knock) B = b (armed in part set B) C = c (armed in part set C) OMIT = OA (omit allow) Example: Zone 3 is a Normal Alarm, active in Part Set B and C, that is Omit Allowed. Type in: 03 Zone Number 3 Normal Alarm B Active in Part Set B C Active in Part Set C OMIT Omit Allow CLEAR to store the value of the command. Output 1 11 x y x = Output Type, one of: 0 = Bell follow 1 = Exit/entry follow 2 = Set latch type 1 Y 3 = Set latch type 2 4 = Shock sensor reset 5 = Walk test 6 = Entry system 7 = 24 hour alarm y = Output state, one of: 8 = positive applied Y 9 = positive removed Output 2 12 x y (as for command 11) 4 9 Engineer Code 20 nnnn Engineer code 7890 Bell Output Type 21 0 SAB, negative applied in alarm Y 1 SCB, negative removed in alarm Loudspeaker Chime 22 1 Chime through loudspeaker & kypds Y 0 Chime through keypads only RedCare reset 23 0 Disabled Y 1 Enabled 8 of 14 496334 Issue 1

9800 Engineer Program Commands To change: Key-in: Notes Default Duress mode 24 0 Audible 1 Silent Y Internal Sounder 25 0 Follows external bell Y 1 Continuous Sounder Delay on Entry 26 0 Normal 1 Delay always Y PA Response 30 0 Audible Y 1 Silent Night Line Fault Response 31 0 Full alarm 1 No alarm Y Day Line Fault Response 32 0 Audible Y 1 Silent System Reset 33 0 User reset Y 1 Engineer reset PA Reset 34 0 User reset Y 1 Engineer reset First circuit lockout 35 0 Lock out Y 1 Re-arm Entry Abort 36 0 Disabled Y 1 Enabled (90 seconds abort time) Day tamper comms 37 0 Disable (local audibles only) Y and Engineer on Site 1 Enabled, communicator channel 5 Keypad Input 38 0 Exit terminate Y 1 Keyswitch 2 Lockset Exit Mode 39 0 Timed or terminate set Y 1 Final door set 2 Lock set Auto Re-Arm 40 0 Never 1 Once Y 2 Twice 3 Three times 4 Always Bell Delay 41 0 No delay Y 1 1.5 minutes 2 3 minutes 3 5 minutes 4 10 minutes 5 15 minutes 6 20 minutes 7 Infinite delay 496334 Issue 1 9 of 14

Engineer Program Commands 9800 To change: Key-in: Notes Default Bell Duration 42 1 1.5 minutes 2 3 minutes 3 5 minutes 4 10 minutes 5 15 minutes 6 20 minutes Y 7 nil Entry Time 43 1 10 Seconds Y 2 20 seconds 3 30 seconds 4 45 seconds 5 60 seconds 6 120 seconds Exit Time 44 0 Continuous (exit terminate only) 1 10 Seconds Y 2 20 seconds 3 30 seconds 4 45 seconds 5 60 seconds 6 120 seconds CSID Code 50 n...n Seed code for remote reset Available from Jan 1993 on all models. Area B final exit response 60 0 Final exit Y 1 Normal alarm Area B Entry route 61 0 Entry route Y 1 Start entry timer Area B Exit mode 62 0 As full set 1 Quick set (10s) Y 2 Instant set 3 Deferred set Area B Alarm response 63 0 Keypad sounders only 1 Internal and keypad sounders Y 2 All sounders, no comms 3 Full alarm (comms and sounders) Area C final exit 70 see 60 Area C Entry route 71 see 61 Area C Exit mode 72 see 62 Area C Alarm response 73 see 63 Event log 90 1 View earlier events 3 View later events Test External Bells 91 Bell output operates Clear Bell test ends Test Strobe 92 Strobe output operates Clear Strobe test ends Test Internal sounder 93 Internal sounder operates Clear Internal sounder test ends 10 of 14 496334 Issue 1

9800 Leaving Programming Mode To change: Key-in: Notes Default Test keypad sounder 94 Keypad sounder operates Clear Keypad sounder test ends Test output 1 95 Programmable output 1 operates Clear Output 1 test ends Test output 2 96 Programmable output 2 operates Clear Output 2 test ends Walk Test 97 Zone LED and sounder operate when circuit open Clear End walk test Load defaults 98 Load defaults Leave programming 99 Leaving Programming Mode When all programming has been completed: 1. Key-in 99 at the keypad. The display clears and the Day LED is ON. The system is now in user mode. Note: If there is a fault on the system, for example an open tamper circuit, the display shows this and will not return to Day mode. Press Y (Clear) and rectify the faults. Engineer Reset To perform an Engineer Reset: 1. Check that the display is showing the alarm condition. (Note: if the display shows rr, Press Clear twice.) 2. Key in 0 followed by the Engineer s code (default 7890), followed by 99. The display goes blank and the Day LED glows. Re-Entering Programming Mode Initial Power Up describes how to enter programming mode for the first time in a new installation. If you wish to enter programming mode at any other time: 1. Make sure the system is unset. 2. Press 0, then key in the Engineer s code (default 7890). The keypad gives an intermittent tone. 3. Open the end station lid. The display shows E (for engineer ) and the intermittent tone stops. You are now in programming mode. 496334 Issue 1 11 of 14

Refreshing the NVM 9800 Refreshing the NVM If the user and/or engineer codes are lost, or you want to revert to the factory default programming, then: 1. First remove mains power before opening the case and then disconnecting the battery. 2. Identify and remove the NVM chip (IC4) on the main pcb (see Figure 1). 3. Reconnect the battery, then re-apply mains power. 4. Refit the NVM chip (note the locator marker position, see Figure 1). The end station loads the factory default access codes (User 1: 1234, engineer: 7890). 5. Carry on to re-program the system. Testing You may test parts of the system by entering commands at the keypad. To carry out a test make sure the system is in programming mode and then key in one of the following commands. Press Clear to end each test: 91 To test the external sounder/bell. 92 To test strobe output. 93 To test the internal sounder output. 94 To test the keypad sounder. 95 To test programmable output No. 1. 96 To test programmable output No. 2. 97 To carry out a system walk test. This allows the engineer to test all alarm devices. When a circuit is opened, the internal sounder(s) will emit a tone and the appropriate circuit LED lights. Reading the Log The control unit keeps a 60 event log of recent events. Each event is represented by a two digit code, shown on the next page. To review the event log, make sure the system is in programming mode, then: 1. Key in 90. The display shows the most recent event in the log, for example "c7". For a list of the log codes see the next page. 2. Key in 1 to show earlier events or 3 to see more recent events. 3. Press Clear to leave the log. 12 of 14 496334 Issue 1

9800 Event Log Displays The table below shows all the messages that can appear in the event log. The left hand column shows the codes that appear on a keypad display. Event Log Displays Keypad Meaning AA Arm area A (full set) Ab Arm area B (part set) Ac Arm area C (part set) AE Installer access AP Auxiliary power failure bf Battery fault c1 to c8 Zone violation cc Communication successful cf Communications failure E1 to E8 Entry via zone circuit EA Entry alarm EF Exit fault Lb Low battery Lf Telephone line failure Lt End station lid tamper o1 to o8 Zone omitted PF Mains power failure r1 to r4 Remote keypad back tamper rp Remote keypad missing rr Installer reset required rt Remote keypad excess key presses tamper S1 to S8 Zone soak Test Sr System reset (total power failure) t1 to t8 Zone tamper violation tr Tamper return fault u1 to u9 Access user (u5 = Duress, u9 = keyswitch) 496334 Issue 1 13 of 14

9800 User Commands Set/Unset System User code + A Part Set User code + B or C Omit zone (1-8) User code + A, B or C + OMIT + Zone number Omit 24 hour zone User code + OMIT + Zone number Reinstate omitted 24 hour zone User code + OMIT + CLEAR Change User code User code + 4 + old code + new code + CLEAR Read Log User code + 5 + 1 to see earlier events or 3 to see later events + CLEAR + CLEAR Chime On/Off User code + 7 + CLEAR Bell Test User code + 8 + CLEAR to end test Walk Test User code + 9 + CLEAR to end test Note: Duress code default is OMIT OMIT OMIT OMIT and is inactive until changed. 14 of 14 496334 Issue 1