SITOP 3-phase 24 V DC, 30 to 40 A

Similar documents
SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.

Related catalogs. Trademarks ITC. Training for Information and Industrial Solutions 1) The offline Mall of Automation and Drives KT 10.

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

is then retained absolutely without interruption.

Actuator-Sensor-Interface

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

Power Supplies 3. SDN-P DIN Rail Series

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Safety technique. Emergency stop module BO 5988 safemaster

PHOENIX CONTACT - 01/2007

Redundancy Module QUINT-DIODE/40

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

LOGO! logic module. 2/2 Introduction 2/2 LOGO! logic module

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relay CM-PFE

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Industrial Power Supplies

Product and functional description

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

650W Single Output Power Supply

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Thyristor-controlled power supplies and battery chargers

I STAR COMPUTER CO., LTD

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Single Output Switching Power Supply

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

DOCUMENTATION PD16 CP3-SVE-M75DC-24

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

How can a charging station for electric vehicles be set up simply and safely?

APD / Outputs 19" DC/DC Converter, 50 Watt

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Digital input modules

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Electronic overload relay EF19 and EF45

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

PHOENIX CONTACT Features

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

5SV Residual Current Protective Devices

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

LOGO! logic module. 2/2 Introduction

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Datasheet. Arrant-Light Oy. 120W DR Series

Modular I/O System Analog and Digital Interface Modules

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Relés e Contatores de Estado Sólido SIRIUS

7 - Phaseo power supplies and transformers

Preset Counter signo 721

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Electronic overload relay EF65, EF96 and EF146

mecotron Safety relay ESTOP-2 For emergency stop monitoring

UMEC International Corporation

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

LOGO! Logic module. Brochures For brochures serving as selection guides for SIMATIC products refer to: printmaterial

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Operating Manual UWAPS-TINY Series

AC-DC Single Output Power Module

Antec TruePower User's Manual

3000W Single Output Power Supply

PCS0100en Persy Control Services B.V. Netherlands

3000W Single Output Power Supply

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

ABB i-bus KNX SA/S Switch Actuators Product Manual

NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

E-STOP relays, safety gate monitors

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

MODEL PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48 MAX OUTPUT WATTAGE[W]

CompactLogix Power Supplies Specifications

Transcription:

Siemens AG 2011 SITOP 3-phase, 30 to 40 A /2 SITOP PSU300B 30 A /2 SITOP PSU300M 40 A /3 40 A /3 SITOP PSU300S 40 A /6 Ordering data and additional information Export regulations AL and ECCN see page 17/9 Siemens KT.1 2012

SITOP 3-phase Siemens AG 2011 Overview Product Special design PSU300B NEW PSU300M Power supply, type 30 A 40 A Order No. 6EP1 437-3BA20 6EP1 437-3BA 1) The product families are highlighted in the same color. For an explanation of the product families, see chapter 1, pages 1/8 through 1/12. Expansion possibilities Power supply optimized for battery charging, with 3-phase wide-range input for use around the world; small frame size; with switchable output characteristic; functional expansion possible if expansion modules are used. Modular power supply with 3-phase wide-range input for use around the world; small frame size; with 50 % extra power for 5 s/min and switchable output characteristic; functional expansion possible if expansion modules are used. Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds (chapter 11) and DC UPS for additional protection against mains failures (chapter 12). Technical data Product Special design PSU300B PSU300M Input Rated voltage value V in rated 400 to 500 V wide-range input 400 to 500 V wide-range input Voltage range 320... 575 V 320... 575 V Overvoltage strength Mains buffering at I out rated > 20 ms at V in = 400 V > 15 ms at V in = 400 V Rated line frequency value; range 50/60 Hz; 47... 63 Hz 50/60 Hz; 47... 63 Hz Rated current I in rated 1.6-1.3 A 2.6-2.1 A Switch-on current limit (+25 C) < 56 A < 56 A I 2 t < 2.24 A 2 s < 2.24 A 2 s Built-in incoming fuse None None Required protection in the supply feeder 3-pole connected miniature circuit breaker... 16 A, characteristic C or circuit breaker 3RV2011-1DA (set to 3 A) or 3RV2711-1DD (UL 489) 3-pole connected miniature circuit breaker... 16 A, characteristic C or circuit breaker 3RV2011-1DA (set to 3 A) or 3RV2711-1DD (UL 489) Output Rated voltage V out rated Total tolerance ± 3 % ± 3 % Static line compensation < ±0.1 % < ±0.1 % Static load compensation < ±0.1 % < ±0.1 % Residual ripple < 0 mv pp < 0 mv pp Spikes (bandwidth: 20 MHz) < 200 mv pp < 200 mv pp Adjustment range 24... 28.8 V 24... 28.8 V (max. 960 W) Status display Green LED for 24 V OK Green LED for 24 V OK Signaling Relay contact (NO contact, contact rating DC 60 V/0.3 A) for 24 V OK On/off behavior No overshoot of V out (soft start) No overshoot of V out (soft start) Startup delay/voltage rise < 2.5 s/< 500 ms < 2.5 s/< 500 ms Rated current value I out rated 30 A 40 A Current range Up to +60 C 0... 30 A 0... 40 A Derating 25 A (up to +70 C) 25 A (up to +70 C) Relay contact (NO contact, contact rating DC 60 V/0.3 A) for 24 V OK Dynamic overcurrent on Power-up on short-circuit Approx. 32 A constant current Approx. 44 A constant current Short circuit during operation Approx. 32 A constant current Typ. 120 A for 25 ms Parallel switching for enhanced performance (switchable characteristic) (switchable characteristic) 1) SIPLUS module see page 15/4. /2 Siemens KT.1 2012

Siemens AG 2011 SITOP 3-phase SITOP smart PSU300S 40 A 40 A 6EP1 437-3BA00 1)2) 6EP1 437-2BA20 NEW Modular power supply with 3-phase wide-range input for use around the world; small frame size; with switchable output characteristic; functional expansion possible if expansion modules are used. Powerful standard power supply with 3-phase wide-range input for use around the world; high overload capability with 50 % extra power for 5 s/min and 1.2 times the rated current continuously up to +45 C ambient temperature. Expansion modules, such as redundancy modules or selectivity modules for protecting 24 V feeds (chapter 11) and DC UPS for additional protection against mains failures (chapter 12). SITOP smart PSU300S Wide-range input AC Wide-range input 320... 550 V (startup from V in > 340 V) 340... 550 V 2.3 V in rated, 1.3 ms 2.3 V in rated, 1.3 ms > 6 ms at V in = 400 V > 6 ms at V in = 400 V 50/60 Hz; 47... 63 Hz 50/60 Hz; 47... 63 Hz 2.2 A (V in = 400 V) 1.7-1.5 A < 70 A < 60 A < 2.8 A 2 s < 3.4 A 2 s None 3-pole connected miniature circuit breaker... 16 A, characteristic C or circuit breaker 3RV2011-1DA (set to 3 A) or 3RV2711-1DD (UL 489) None 3-pole connected miniature circuit breaker... 16 A, characteristic C or circuit breaker 3RV2011-1DA (set to 3 A) or 3RV2711-1DD (UL 489) ± 3 % ± 3 % Approx. 0.1 % Approx. ±1 % Approx. 0.2 % Approx. ±2 % < 0 mv pp < 150 mv pp < 200 mv pp < 240 mv pp 24... 28.8 V (max. 960 W) 24... 28.0 V (max. 960 W) Green LED for 24 V OK Green LED for 24 V OK Use signaling module (6EP1961-3BA) Relay contact (NO contact, contact rating DC 60 V/0.3 A) for 24 V OK No overshoot of V out (soft start) No overshoot of V out (soft start) < 2.5 s/< 500 ms < 1.5 s/typ. 15 ms 40 A 40 A 0... 40 A 0... 40 A > 60 C 48 A (up to +45 C)/30 A (up to +70 C) Approx. 46 A constant current Typ. 120 A for 25 ms (switchable characteristic) Approx. 65 A for 120 ms Approx. 65 A for 120 ms 1) SIPLUS module see page 15/4. 2) plus 6EP1 437-3BA00-8AA0 with circuit board varnished for protection Siemens KT.1 2012 /3

SITOP 3-phase Siemens AG 2011 Technical specifications (continued) Product Special design PSU300B PSU300M Power supply, type 30 A 40 A Order No. 6EP1 437-3BA20 6EP1 437-3BA Efficiency Efficiency at V out rated, I out rated Approx. 93 % Approx. 92 % Power loss at V out rated, I out rated Approx. 50 W Approx. 83 W Closed-loop control Dyn. mains compensation <1 % V out <1 % V out (V in rated ± 15 %) Dynamic load smoothing Typ. ±3 % V out Typ. ±3 % V out (I out : 50/0/50 %) Load-step settling time 50 to 0 % < ms < ms 0 to 50 % < ms < ms Protection and monitoring Output overvoltage protection < 35 V < 35 V Current limitation Typically 32 A Typ. 44 A, overload capability 150 % I out rated up to 5 s/min Short-circuit protection Alternatively, constant current characteristic approx. 32 A or latching shutdown Alternatively, constant current characteristic approx. 44 A or latching shutdown Sustained short-circuit current rms Approx. 32 A Approx. 44 A value Overload/short-circuit indicator LED yellow for "overload", LED red for "latching cutoff" LED yellow for "overload", LED red for "latching cutoff" Safety Primary/secondary isolation Yes, SELV output voltage V out according to Yes, SELV output voltage V out according to Protection class Class I Class I Leakage current < 3.5 ma < 3.5 ma Safety test Yes Yes CE mark Yes Yes UL/cUL (CSA) approval culus-listed (UL 508, CSA C22.2 No. 7.1) File E197259 culus-listed (UL 508, CSA C22.2 No. 7.1) File E197259 Explosion protection ATEX (available soon) Marine approval GL and ABS available soon Degree of protection (EN 60529) IP20 IP20 EMC Emitted interference EN 55022 Class B EN 55022 Class B Supply harmonics limitation EN 600-3-2 EN 600-3-2 Noise immunity EN 600-6-2 EN 600-6-2 Operating data Ambient temperature range -25... +70 C with natural convection -25... +70 C with natural convection Transport/storage temperature -40... +85 C -40... +85 C range Humidity class Climate class 3K3 according to EN 60721, Climate class 3K3 according to EN 60721, Mechanics Connections Supply input L1, L2. L3, PE Output + Output Alarm signal 0.33... mm 2 0.33... mm 2 0.33... mm 2 0.33... mm 2 0.14... 1.5 mm 2 0.14... 1.5 mm 2 Dimensions (W x H x D) in mm 150 125 150 150 125 150 Weight, approx. 3.4 kg 3.4 kg Installation Snaps onto DIN rail EN 60715 35x15 Snaps onto DIN rail EN 60715 35x15 Accessories Buffer module (6EP1961-3BA01) Device labeling plates (3RT1900-1SB20) Buffer module (6EP1961-3BA01) Device labeling plates (3RT1900-1SB20) /4 Siemens KT.1 2012

Siemens AG 2011 SITOP 3-phase SITOP smart PSU300S 40 A 40 A 6EP1 437-3BA00 6EP1437-2BA20 Approx. 90 % Approx. 91.5 % Approx. 6 W Approx. 89 W <1 % V out <3 % V out Typ. ±2 % V out Typ. ± 1.5 % V out < ms (typ. 4 ms) < ms (typ. 1 ms) < ms (typ. 4 ms) < ms (typ. 1 ms < 35 V Yes, according to EN 60950 Typically 46 A Typ. 50 A, overload capability 150% I out rated up to 5 s/min Alternatively, constant current characteristic approx. Electronic shutdown, automatic restart 46 A or latching shutdown Approx. 46 A Approx. 14 A LED yellow for "overload", LED red for "latching cutoff" Yes, SELV output voltage V out according to Yes, SELV output voltage V out according to Class I Class I < 3.5 ma < 3.5 ma ma (typ. 1 ma) Yes Yes Yes Yes; CB scheme UL-listed (UL 508) File E197259, CSA (CSA C22.2 culus-listed (UL 508, CSA C22.2 No. 7.1) No. 14, CSA C22.2 No. 7.1) ATEX (EX) II 3G Ex na nc IIC T3 GL in preparation IP20 IP20 EN 55022 Class B EN 55022 Class B EN 600-3-2 EN 600-3-2 EN 600-6-2 EN 600-6-2 0... +70 C with natural convection 0... +70 C with natural convection -40... +85 C -40... +85 C Climate class 3K3 according to EN 60721, Climate class 3K3 according to EN 60721, 0.33... mm 2 0.5... mm 2 0.33... mm 2 0.5... mm 2 0.14... 1.5 mm 2 240 125 125 150 145 150 3.2 kg 3.7 kg Snaps onto DIN rail EN 60715 35 15 Snaps onto DIN rail EN 60715 35 15 Buffer module (6EP1961-3BA01) Signaling module (6EP1961-3BA) Siemens KT.1 2012 /5

SITOP 3-phase Siemens AG 2011 Selection and ordering data Product Input Output Order No. Price Voltage V in rated Voltage V out rated Current I out rated Special design, PSU300B NEW (Planned delivery date: December 2011) 30 A 6EP1 437-3BA20, PSU300M 40 A 6EP1 437-3BA 40 A 6EP1 437-3BA00 Version with circuit board varnished for protection 6EP1 437-3BA00-8AA0 SITOP smart, PSU300S NEW 40 A 6EP1437-2BA20 Further information Additional information is available in the Internet under: 2D dimensional drawings, 3D CAD data, circuit diagram macros: www.siemens.com/sitop-cax Operating instructions: www.siemens.de/sitop-manuals Find the right product with the SITOP Selection Tool: www.siemens.com/sitop-selection-tool /6 Siemens KT.1 2012