SmartFan Cirrus-6 Programmable Speed Control for 4-Wire Fans

Similar documents
DS1621 Digital Thermometer and Thermostat

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

UniPi technical documentation REV 1.1

SYSTEM 4C. C R H Electronics Design

DS1621 Digital Thermometer and Thermostat

DS Wire Digital Thermometer and Thermostat

Analog Servo Drive 25A8

SYSTEM 45. C R H Electronics Design

NC-12 Modbus Application

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

User and installation manual

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Brushless DC Motor Controller Product Specification Assembly 025F0129

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

NB3H5150 I2C Programming Guide. I2C/SMBus Custom Configuration Application Note

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Install the DeviceNet Module using the following procedure:

AN2680 Application note

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

PCS0100en Persy Control Services B.V. Netherlands

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TC-9102 Series Surface Mount Temperature Controllers

7 OUT1 8 OUT2 9 OUT3 10 OUT4 11 OUT5 12 OUT6 13 OUT7 14 OUT8 15 OUT9 16 OUT10 17 OUT11 18 OUT12 19 OUT13 20 OUT14 21 OUT15 22 OUT16 OUT17 23 OUT18

Talon and Talon SR User Manual

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Ordering Part Numbers:

Multifunction devices

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm

Name Description P/N. Programmer Programmer with calibration function SDD-AAPNP. Parameter Min. Typ. Max. Notes. (Vo+ - Vo-) - Voltage

Data Sheet. Adaptive Design ltd. Arduino Dual L6470 Stepper Motor Shield V th November L6470 Stepper Motor Shield

How To Power A Schen

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

MODULE BOUSSOLE ÉLECTRONIQUE CMPS03 Référence :

Duct Humidity Transmitter

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

RS - SPM. Serial parallel translator module

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

HDMM01 V1.0. Dual-axis Magnetic Sensor Module With I 2 C Interface FEATURES. Signal Path X

User Manual for CH-PFC76810

DS1307ZN. 64 x 8 Serial Real-Time Clock

User manual Rev. 1.2 (17/04/2015)

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Series AMLDL-Z Up to 1000mA LED Driver

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Non-Isolated Analog Voltage/Current Output module IC695ALG704 provides four configurable voltage or current output channels. Isolated +24 VDC Power

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

LM75 Digital Temperature Sensor and Thermal Watchdog with Two-Wire Interface

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

EMC6D103S. Fan Control Device with High Frequency PWM Support and Hardware Monitoring Features PRODUCT FEATURES ORDER NUMBERS: Data Brief

SMART SENSOR COLLECTION

DCS Series 1 kw, 1.2 kw, & 3 kw

Digital input modules

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Installation and User Guide

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

INSTALLATION MANUAL XM3 Reader

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Manual for Fire Suppression & Methane Detection System

UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation

DCP Fan Controller. Version 01/2009. The engineer s choice

PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section

GLOLAB Universal Telephone Hold

The I2C Bus. NXP Semiconductors: UM10204 I2C-bus specification and user manual HAW - Arduino 1

Model: DC-A2IO Advanced HVAC Controller

FLYPORT Wi-Fi G

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

ARDUINO SEVERINO SERIAL SINGLE SIDED VERSION 3 S3v3 (REVISION 2) USER MANUAL

Electronic Control Devices The European Product Catalogue 2007

Neonixie 6 Digit Nixie Clock Controller Introduction and Assembly

Electronic Control Devices The European Product Catalogue 2007

GSM Autodialer Professional GJD700 Speech & Text Autodialer

Model 201 Wiegand Touchpad Reader Installation Guide

HP4000EX Hardware Manual

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

Y.LIN ELECTRONICS CO.,LTD.

Adafruit MCP9808 Precision I2C Temperature Sensor Guide

User manual LCD 240-2xx

Smart Sensing Solutions Since 1954

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs

DC Electronic Loads 8500 series

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

AP331A XX G - 7. Lead Free G : Green. Packaging (Note 2)

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Users manual. TCW181B-CM_R1 Page 1

1 Application Description Objective Goals... 3

Innovative Electronics for a Changing World INDEX

TEP 200WIR Series, Watt

Allen-Bradley/Rockwell

Application/Connection Examples

Troubleshooting and Diagnostics

Transcription:

For engineers, by engineers. SmartFan Cirrus-6 Programmable Speed Control for 4-Wire Fans Cirrus 6 shown with optional Navigator custom programming tool DC Controls SmartFan Cirrus-6 is a programmable fan speed control designed to monitor and manage up to six 12, 24 or 48VDC 4-wire fans or blowers. The Cirrus-6 can be programmed using the Navigator PRG00-F handheld remote programmer or with an I2C interface. When programming with the Navigator, one can customize a temperature control curve, temperature alarm trigger, low speed alarm trigger, fail-safe modes and more. When programming using an I2C interface, one has the same control programming options as the Navigator plus the ability to control and monitor fans via the I2C interface. Factory customization available for quantities as low as 50 pieces. ( See page 2 for customization options ) Specifications: Features: Power Source: 10-60VDC, single or dual feed diode OR d Extended Voltage Ratings: Up to 76VDC can be achieved when used with the SmartFan Multi SD or Storm regulator Total Fan Current: Up to 12 Amps (single power feed only), 2.5 Amps max per fan Compatible Fans: Up to six 12, 24 or 48VDC, 4-wire fans (open collector PWM or 0-12VDC PWM control) On-board 3.3 / 5.0VDC isolated power for I2C and other control signals Operating Environment: -20 C to 60 C, RH 95% non-condensing Storage Temperature: -40 C to 125 C Weight: 1.9 oz (53 grams) RoHS (6/6) compliant Control temperature accuracy and hysteresis: ±2 C Control Signals & Programming Modes (Off-the-Shelf) I2C interface (single or dual) used to control speed or set up temperature control parameters Temperature control parameters can be programmed using the Navigator remote programmer PRG00-F (rented or sold separately) Status and Alarm reporting Fan speed, temperature and alarm conditions are programmable through I2C interface and reported through I2C, LED or MOS relay connections Temperature alarms and fan speed alarms are programmable with Navigator remote programmer and reported through LED or MOS relay Factory programming available for orders as low as 50 pcs. UL Recognized to UL508 and CSA-C22.2, File E100344 www.controlresources.com 2014.3.JM

For engineers, by engineers. Ordering Part Number Total Fan Current / Power Feed 4-Wire Fan Signal Type 4WR6C00-F 6 Amps / Single or Dual Open Collector PWM 4WR6V00-F 6 Amps / Single or Dual 0-12 VDC PWM 4WR12C00-F 12 Amps / Single Open Collector PWM 4WR12V00-F 12 Amps / Single 0-12 VDC PWM H125-F PRG00-F Hardware Pack (optional) Navigator remote programmer available for rent or purchase. Required to program controller when no I2C capabilities are available * * * To sense or control temperatures off the board choose a temperature sensor from www.controlresources.com/sensors Dimensions 4.55 (115.6mm) 0.156 (3.96mm) Diameter Holes x 5 places 1.500 (38.1mm) 1.100 (27.9mm) 0.863 (21.92mm) 0.200 (5.1mm) 9.00 (228.6mm) 8.600 (218.4mm) 0.080 (2.03mm) Lead Length Max. 0.063 (1.57mm) PCB Thickness Customized Configuration Options Factory programming of standard control parameters Non-standard 4-wire fan signal types Multiple control parameters to control 2 or more sets of fans Up to 3 temperature sensors Analog control signals (i.e.: 4-20mA, 0-5VDC...) Individual fan fusing Custom I2C reporting data Conformal coating Custom diode ORing ( negative feed, both feeds, none ) Custom fan speed alarm triggers Output Current ( Amps ) 14 12 10 8 6 4 2 0 Current Derating vs. Ambient Temperature 4WR12X00-F 4WR6X00-F 20 30 40 50 60 70 75 80 85 Ambient Temperature ( Celsius ) www.controlresources.com 2014.3JM

INSTALLATION MOUNTING To maintain safety and reliability, the Cirrus 6 should be mounted in a ventilated enclosure so as to maintain an operating temperature of 60 C or less. Using the PCB support hardware specified in hardware pack H125-F (see below), or hardware of your choosing, mount the Cirrus-6 on a flat surface using all five mounting holes for maximum support. Note: To meet UL recommendations without using an insulator, the unit must be mounted at least.25 from a conductive surface. Header J7 J14 J1 - J6 J12 J9 & J11 Or equivalent Table 1: Recommended Hardware H125-F Hardware Pack Mfg. & P/N Qty Description Mfg. & Part No. 26-60-4040 26-60-4020 22-29-2041 22-29-2121 22-29-2041 1 Housing 4 (tin) 1 Housing 2 (tin) 6 Housing 24 (gold) 1 Housing 12 (gold) 2 Housing 8 5 (gold) PCB Support 09-50-8041 08-50-0106 09-50-8021 08-50-0106 22-01-3047 08-55-0102 22-01-3127 08-55-0102 22-01-3047 08-55-0102 Richco No. CBS-4-19 Input Power J7A/J7B (4WR6C00-F, 4WR6V00-F) Connect single or dual 10-60VDC supplies to J7. For one supply, connect to A+ and A-, for dual supplies; connect the second supply to B+ and B-. Input Power J7B/J14 (4WR12C00-F, 4WR12V00-F) Connect a single 10-60VDC supply only to J7B and J14. When total fan current exceeds 6 Amps, make sure to connect supply to all 4 positive and negative pins. Controller Status LED Connection J9 (Optional) Header J9 provides local indication of Alarm (Red LED, Pin R) and Normal (Green LED, Pin G) status. Choose 2 single color LEDs or 1 bi-color LED (2 leaded) with a rated forward voltage (V f ) between 1.6 and 2.4 VDC at a forward current (I f ) of between 15 and 25 ma. Nominal current applied to the LEDs is 8 ma. CONNECTIONS Refer to table 1, figure 1, table 2 and the paragraphs below to connect your Cirrus 6. Fan Connections (J1-J6) Cirrus-6 distributes power to and monitors the tachometer signals from up to six four-wire fans. Fan current at each fan header must not exceed 2.5 Amps. Total fan current must not exceed the current rating of the Cirrus-6 model being used. For controller ambient temperature above 60 C, reference the derating curve on page 2. Figure 1: Connection diagram Connection of MOS Relay Alarm J11 (Optional) A dual MOS relay is provided on header J11. Pins 1A and 1B output is closed on no alarm. Pins 2A and 2B output is Page 3 of 8

open on no alarm. The alarm circuits on header J11 are isolated from all other pins and have no polarity. These outputs have a maximum on-state resistance of 50. Maximum sinking current is 100mA. A maximum of 230 VAC/VDC can be applied to alarm terminals. Remote Temperature Sensor J12 (Optional) All Cirrus 6 models come with an on board temperature sensor (T2) that can be used for monitoring board temperature or controlling fan speed based on temperature. The Cirrus-6 can also be configured to operate with an external sensor (sold separately, reference www.controlresources.com/sensors). There is no polarity consideration when connecting the sensor. Temperature accuracy and hysteresis is 2ºC. Table 2: Connector Pin Assignments Header Label Description J7 / J14 J1- J6 J9 J12 J11 A+ A Power Supply Positive B+ B Power Supply Positive A- A Power Supply Negative B- B Power Supply Negative - Fan, Negative C A Fan, Speed Control Signal Fan, Tachometer Signal + Fan, Positive GND G R GND Green LED Cathode Green LED Anode Red LED Anode Red LED Cathode 1 I2C Address A0 2 I2C Address A1 3 I2C Address A2 4 Speed Override Input 5 Not Used 6 Not Used 7 External Thermistor Input D1 C1 D0 C0 GND 1A 1B 2A 2B SDA for Secondary I2C Bus SCL for Secondary I2C Bus SDA for Primary I2C Bus SCL for Primary I2C Bus Isolated/Logic Ground NC MOS Relay NC MOS relay NO MOS Relay NO MOS Relay Speed Override Input J12 (Optional) A logic level input is located on J12 that allows the user to command the fans to full speed when pin 4 is tied to GND. If this input is set to VCC or left open, then the speed is set by its normal operating mode. Default is 100% and can be adjusted with the Navigator. I2C Bus Connection J12 (Optional) The Cirrus 6 can be used with or without I2C communications. When no I2C is present, the Cirrus 6 will control fan speed by sensing temperature, programming is done via the SmartFan Navigator hand-held programmer, no additional connections to J12 are required. When using I2C communications to program, control and monitoring is provided by a dual or single I2C Bus on pins C0, D0, C1, D1, see I2C Programming and Control section for details. PROGRAMMING FOR TEMPERATURE Cirrus-6 can be programmed using a Navigator PRG00-F programmer (www.controlresources.com/navigator) or using an IC2 bus. If programming with I2C, skip this section and go directly to I2C PROGRAMMING &. Cirrus-6 can also be preprogrammed at the factory in production volumes at no additional cost, contact CRI customer service for details. Navigator Handheld Remote Programmer Refer to figure 2 and table 3 below to develop and program your temperature control curve. Page 4 of 8

ALARM SETTINGS SETTINGS SYSTEM SETTINGS SmartFan Cirrus-6 Datasheet Figure 2: Fan speed signal vs. sensor temperature. Options Selection Default NUMBER OF FANS 1-6 6 TEMP SENSOR External / On Board External SPEED ON SIGNAL LOSS Full / Idle Full PWM FREQUENCY 2.5kHz /5.0kHz /10kHz / 20kHz 2.5kHz FULL SPEED PWM 100% - 0% 100% IDLE SPEED PWM 0% - 100% 55% IDLE TEMP -20 C to 80 C 35 C FULL SPEED TEMP 80 C to -20 C 40 C OFF TEMP -20 C to 80 C / Disabled Disabled No Alarm / TACH TRIP POINT 1000 / 2000 / 2000 PPM 4000 PPM ALARM TEMP 80 C to -20 C / Disabled Disabled Table 3: Cirrus-6 Navigator Menu NAVIGATOR PROGRAMMING 1) Connect Navigator to the Cirrus-6 through the RJ45 connectors using the Ethernet cable supplied. Apply power to the Cirrus-6 to enable programming via the Navigator. See table 3 for a description of each programming option. 2) Navigator will display its current revision briefly then it will show the product type connected. Cirrus-6 is ready 3) Select the number of fans (1-6) connected. The value is adjusted with the or keys and the Next key will bring you to the next parameter. Set # of fans, 6 Note: At any time the Previous key can be used to go back to the previous menu and the Write Drive key can be used to save all the settings in the Cirrus-6. 4) Use the or keys to select the On-Board temp. sensor or External temp. sensor (connected at J12 pin 7 & GND) to be used for temperature control. press the Next key to go to the next parameter. Temp Sensor External 5) Use the or keys to adjust the speed of the fan or motor if the temp. sensor signal is lost. The available options are idle speed or full speed. Speed on signal loss Full Once the desired speed is displayed, press the Next key. 6) Use the or keys to select the PWM frequency. The options are 2.5kHz, 5.0kHz, 10kHz, or 20kHz. Refer to the fan specification for the recommended frequency. Once the desired frequency is displayed, press the Next key. Set PWM freq. 2.50kHz 7) Use the or keys to adjust the full speed for the fan or motor. This sets the PWM duty cycle from 0% to 100% in 1% increments. Once the desired output duty cycle is displayed, press the Next key. Set full speed 100% 8) Use the or keys to adjust the idle speed for the fan or motor. This sets the PWM duty cycle from 0% to 100% in 1% increments. Note the idle can be set higher than the full speed for heating applications or to compensate for fans with reverse slope input control curves. Once the desired output duty cycle is displayed, press the Next key. Page 5 of 8

Set idle speed 55% 9) Use the or keys to select the temperature at which you want the fans to idle. Options are between -20 C and 80 C with 1. Once the desired temp. is displayed, press the Next key. Set idle temp. 35C 10) Use the or keys to select the temperature at which you want the fans to reach full speed. Options are between -20 C and 80 C with 1. Once the desired temp. is displayed, press the Next key. Set full temp. 40C 11) Use the or keys to select the temperature at which you want the fans to turn off. Options are between -20 C and 80 C with 1 or Disabled. Fans will not turn off (as long a power is applied) when Disabled is selected. Once the desired level is displayed, press the Next key. Set off temp. Disabled 12) Use the or keys to select the tachometer alarm trip point. When fan speed falls below the trip point, the alarm output will be activated and the PWM will be forced to full speed. The options are No Alarm, 1000PPM, 2000PPM, and 4000PPM. PPM (pulses per minute) = RPM x PPR (pulses per revolution). No Alarm disables the tachometer alarm. Once the desired trip point is displayed, press the Next key. Set tach trip point 2000 PPM 13) Use the or keys to select the temperature at which you want an alarm to be triggered. Options are between -20 C and 80 C with 1 or Disabled. Once the desired level is displayed, press the Next key. Set alarm temp. Disabled 14) Cirrus-6 will now cycle back to the Set # of Fans screen. To review the existing parameters of a programmed Cirrus-6, scroll through parameters using the Next or Previous keys. Parameters can be changed at any time using the or keys. 15) Once all parameters are correct, press the Write Drive key to save the settings to the Cirrus-6. Disconnecting power from the Cirrus-6 before pressing Write Drive will discard any changes and reload the parameters from its previous memory. OTHER NAVIGATOR FUNCTIONS Refer to the instructions that came with your Navigator or down the datasheet from www.controlresources.com/navigator to learn how to: Copy a program from one Cirrus 6 to another Save a program to Navigator memory Customize a program name Recall a program from Navigator memory I2C PROGRAMMING & When an I2C speed command is given, the Cirrus-6 automatically switches to I2C control mode for fan control via the I2C Bus. The speed of all fans is mapped to the command sent through the I2C on header J12. I2C Bus Protocol The I2C Bus is configured as a slave device that can transmit and receive data. When the Cirrus-6 is configured for I2C based speed control, the user can write speed commands to the Cirrus-6 and read all alarm status bits. When configured for temperature based control the user can read all alarm status bits from the Cirrus-6. Writing an I2C speed command changes the control mode from temperature based to I2C based. Specifications The Bus supports seven-bit addressing and only acts as a slave device. The address for the fan controller is 0001A2A1A0. General call support is not provided. The fan controller will stretch the clock further if needed. The I2C master must observe clock stretching. Page 6 of 8

The hardware register will support Standard Mode I2C with speeds up to 100 KHz, however, lower clock speeds are recommended for increased noise immunity. If temperature control mode is disabled and I2C speed mode is used, then I2C communication must occur within ~2 minutes of the last communication, or there will be an I2C communication timeout error. When an I2C timeout occurs, full speed will be applied to the fans, and fan speed must be reset with a new speed command. Performing any valid I2C operation on either bus will clear the timeout condition and restart the watchdog timer. Fan failure based on 2000 minimum PPM of fan in slow (default) mode or 4000 minimum PPM in fast mode. Fan failure is not updated when the output is set to 0%. It is possible for noise to cause the I2C hardware to miss an address or data. In this case an Ack will not be generated. The production tester allows 3 errors to occur before marking the board as failing. Also during the EEPROM write cycle the I2C will not generate ACK signals as no more data can be accepted until the write cycle is complete. Typical write cycle is 8ms. I2C specifies a maximum sink current of 5 ma and macimum bus capacitance of 400 pf. Table 4 defines the bits used in the serial bus protocol. Table 4: I 2 C Bus Definitions ACK Acknowledge ACK Not Acknowledge (End of Transmission) A6 A0 Address for Fan Controller, bits 6 0 D7 D0 Data TO/FROM Fan Controller, bits 7 0 L7 L0 Data location being accessed, bits 7-0 P Stop Bit R Read Bit (1) S Start Bit W Write Bit (0) On Board Power Supply An isolated 3.3/5.0 VDC is provided on board to power the I2C Bus and control signal interfaces. The jumper on J10 selects the logic VCC. Using Sensors with I2C Configuration Control temperature can be set through the I2C Bus. When configured to operate with a remote external temperature sensor, choose a compatible SmartFan Sensor shown at www.controlresources.com/sensors. Control temperature can also be set through the I2C for the board-mounted temperature sensor. Digital Inputs The Speed input (Pin 4) and the ID inputs (Pins 1-3) are internally pulled to 3.3 VDC or 5.0 VDC with 10.0K resistors. GND (Pin GND) Ground reference pin for the I2C Busses and digital inputs only. Write sequence S A6 A5 A4 A3 A2 A1 A0 W Ack L7 L6 L5 L4 L3 L2 L1 L0 Ack D7 D6 D5 D4 D3 D2 D1 D0 Ack P Read sequence S A6 A5 A4 A3 A2 A1 A0 W Ack L7 L6 L5 L4 L3 L2 L1 L0 Ack P S A6 A5 A4 A3 A2 A1 A0 R Ack D7 D6 D5 D4 D3 D2 D1 D0 Ack P Register Locations: L7-L0 Label (R/W) [initial condition] Register 0x00 0xEF: Generic EEPROM storage (Read/Write) [undetermined] Register 0xF0: Firmware Revision (Read only) [0x01:current rev] Register 0xF1: Alarm0 Status (Read only) [0x00] D0: Status of fan on J1 (0=no fault, 1= fault) D1: Status of fan on J2 (0=no fault, 1= fault) D2: Status of fan on J3 (0=no fault, 1= fault) D3: Status of fan on J4 (0=no fault, 1= fault) D4: Status of fan on J5 (0=no fault, 1= fault) D5: Status of fan on J6 (0=no fault, 1= fault) D6: Always 0 D7: Always 0 Register 0xF2: Alarm1 Status (Read only) [0x00] D0: Always 0 D1-3: Always 0 D4: Status of speed override (0=normal, 1=100%) D5: Status of on-board sensor (0=connected, 1= open) D6: Status of external sensor (0=connected, 1=open) D7: Status of controlling sensor (0=valid, 1=alarm) Register 0xF3: Temperature (Read only) [1111 1111] on-board sensor 0XFF = temperature not read yet or open (Temperatures above 70 are reported as 254) Page 7 of 8

Register 0xF4: Temperature (Read only) [1111 1111] external sensor 0XFF = temperature not read yet or open (Temperatures above 70 are reported as 254) Register 0xF5: Current Target Speed (Read only) [0001 0100] D0-7: 0x14 = 100%, 0x00 = 0% (Commanded speed with alarm status override included) (In temperature mode this register will read 0x14) Register 0xF6: Current Speed (Read only) [0001 0100] D0-7: 0x14 = 100%, 0x00 = 0% (What the actual current voltage is) (In temperature mode this register will read 0x14) Register 0xF7: Commanded Speed (Read/Write) [1111 1111] D0-3: 0x14 = 100%, 0x00 = 0% 0x00 0x14 = 0 100 %, 5% per step If set to 0xFF then temperature mode is enabled and I2C speed control disabled D1-D4: Set to 0, may be set to 1 to allow system to indicate a fan controller reset. D5: 0=5deg slope, 1=10 deg slope for temperature mode only D6: 0=2000PPM tach, 1=4000PPM tach fan alarm speed D7: 0=External, 1=On-board sensor selection for temperature mode only Register 0xFD-0xFF: CRI Test Register (Reserved) [xxxx xxxx] D0-7: Do not use Note: If a fan failure occurs the Current Speed will be updated to full but the Commanded Speed will remain at its previous value. Once the failure clears the Current Speed will return to the Commanded Speed value. An I2C timeout changes BOTH the Current Speed and Commanded Speed to full. The Commanded Speed must be reset after a timeout. During the speed ramp the Current Speed will not match the Commanded Speed until the ramp completes. Register 0xF8: Off Temperature (Read/Write) [1111 1111] Temperature below which the controller turns off the fan output (0% PWM) If set to 0xFF then function disabled Register 0xF9: Control Temperature (Read/Write) [0101 0000] Full speed temperature, only used if Commanded Speed set to 0xFF. Register 0xFA: Alarm Temperature (Read/Write) [1111 1111] Temperature above which the controller alarms If set to 0xFF then function disabled Register 0xFB: Config0 Register (Read/Write) [0011 1111] D0-D5: 0=Mask, 1=Active for an Fan (J1-J6) D6-D7: Not Used Register 0xFC: Config1 Register (Read/Write) [0000 0000] D0: Not Used Page 8 of 8