MULTI PHOTON LASER SCANNING MICROSCOPE FV1000MPE FLUOVIEW NEW



Similar documents
Zeiss 780 Training Notes

Optical laser beam scanner lens relay system

Applications of confocal fluorescence microscopy in biological sciences

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

Taking the Confusion out of Confocal Microscopy

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Neuro imaging: looking with lasers in the brain

Leica TCS SP5 Confocal Laser Scanning Microscope User Guide 1. BASIC IMAGE ACQUISITION

Raman spectroscopy Lecture

A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

Introduction to flow cytometry

Recording the Instrument Response Function of a Multiphoton FLIM System

Chapter 12 Filters for FISH Imaging

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

A VERYbrief history of the confocal microscope 1950s

Optical mesoscopy with a new giant lens. Gail McConnell, Johanna Tragardh, John Dempster & Brad Amos

AxioCam MRm Pure Sensitivity

Fluorescence Microscopy for an NMR- Biosensor Project

Synthetic Sensing: Proximity / Distance Sensors

Advances in scmos Camera Technology Benefit Bio Research

Z-Stacking and Z-Projection using a Scaffold-based 3D Cell Culture Model

Zeiss Laser Scanning Microscope 510. Zuidhorst 178. For more information contact. Tom Groothuis. ZH153,

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

Zecotek S Light Projection Network Marketing

MIRAX SCAN The new way of looking at pathology

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

ZEISS Microscopy Course Catalog

Introduction to Flow Cytometry

Nederland België / Belgique

Introduction to Fourier Transform Infrared Spectrometry

Optik Kolloquium Jena January 17, Modern Applications in Laser Scanning Microscopy. Dr. Ulrich Simon

Optical Coherence Tomography OCT. 3D Imaging in Medical Technology and Quality Control

AxioCam HR The Camera that Challenges your Microscope

CNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual

Real-world applications of intense light matter interaction beyond the scope of classical micromachining.

Zeiss Axioimager M2 microscope for stereoscopic analysis.

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

Archimedes Palimpsest Metadata Standard XRF Extensions DRAFT

Infrared Viewers. Manual

FIXED STAGE UPRIGHT MICROSCOPE BX51WI FIXED STAGE UPRIGHT MICROSCOPE WITH MOTORIZED FOCUSING BX61WI UNIVERSAL INFINITY SYSTEM

Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

Preface Light Microscopy X-ray Diffraction Methods

These particles have something in common

CONFOCAL LASER SCANNING BIOLOGICAL MICROSCOPE FV1000 FLUOVIEW. Next Generation Live Cell Imaging System

Alignment Laser System.

A pretty picture, or a measurement? Retinal Imaging

Measuring Laser Power and Energy Output

Acousto-optic modulator

Data. microcat +SPECT

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

RESEARCH MACRO ZOOM SYSTEM MICROSCOPE MVX10. Macro View. The first true macro fluorescence imaging system

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Theremino System Theremino Spectrometer Technology

Experiment 5. Lasers and laser mode structure

Pump-probe experiments with ultra-short temporal resolution

Two-photon FCS Tutorial. Berland Lab Department of Physics Emory University

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Measuring the Point Spread Function of a Fluorescence Microscope

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

Experiment #5: Qualitative Absorption Spectroscopy

Fluorescent Array Imaging Reader

DIODE PUMPED CRYSTALASER

Materials and Methods

Guideline Laser Series

ProScan DC Linear Servo Stage Technology

product overview pco.edge family the most versatile scmos camera portfolio on the market pioneer in scmos image sensor technology

Fiber Optics: Engineering from Global to Nanometer Dimensions

Near-field scanning optical microscopy (SNOM)

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

WE THINK HE S SHARP TOO.

16 th IOCCG Committee annual meeting. Plymouth, UK February mission: Present status and near future

Designing and Manufacturing Femtoseconds Ultra-broadband Lasers: Proven, Hands-free Reliability

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

Two-photon Fluorescence Light Microscopy

OPERATING INSTRUCTIONS Nikon TiE Deconvolution Microscope CCRB 1-220G

LASER SCANNING CONFOCAL MICROSCOPY

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Make Life Easier by Using Modern Features of the SPCM Software

The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic

INFITEC - A NEW STEREOSCOPIC VISUALISATION TOOL BY WAVELENGTH MULTIPLEX IMAGING

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

INVITATION FOR TENDER FOR SUPPLY OF EQUIPMENT

Flat-Field IR Mega-Pixel Lens

Switch on the system

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

pco.edge 4.2 LT 0.8 electrons 2048 x 2048 pixel 40 fps :1 > 70 % pco. low noise high resolution high speed high dynamic range

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Explaining Ellipse I 2 PL

Powerful Upright Microscope Solutions for Life Science and Clinical Applications

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution

ILLUSTRATIVE EXAMPLE: Given: A = 3 and B = 4 if we now want the value of C=? C = = = 25 or 2

How To Use An Edge 3.1 Scientific Cmmos Camera

INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.

Transcription:

MULTI PHOTON LASER SCANNING MICROSCOPE FV1000MPE FLUOVIEW NEW

Multi photon laser scanning microscope for deep imaging The Olympus Fluoview FV1000MPE, a multi photon laser scanning microscope, allows deeper imaging of living or thickly sliced specimens than conventional confocal laser microscopes can provide. Scientists can delve deeper into living tissue to study dynamic processes, with much less damage to specimens. Optimal for in vivo observation deep within tissue Because it uses a near-infrared laser with superior tissue penetration, the FV1000MPE allows observation deep within living specimens. Minimizes damage to specimens The FV1000MPE uses a near-infrared laser, for greatly reduced phototoxicity. Photodamage to specimens and fluorochromes is minimized, making long-range and time-lapse studies possible. Reduces photobleaching With multi photon excitation, the laser excites only the fluorescent molecules located at the focal plane. Fluorescent molecules above and below the focal plane are not stimulated by the excitation light, so there is minimal photobleaching. Multi photon excitation A laser radiates high-density light at wavelengths up to several times the emission wavelength, causing only those fluorescent molecules located exactly at the focal point to become excited. Confocal-type optical sectioning can be achieved without the use of a pinhole, since light is not emitted from areas outside the focal plane. Confocal laser microscope Single photon Multi photon laser microscope Multi photon Y Single photon Multi photon X Excitation light Fluorescent light Excitation light Fluorescent light Photomultiplier Pinhole Focal point Z 3-dimensionally constructed images of neurons expressing EYFP in the cerebral neocortex of a mouse under anesthesia. Cross-sectional images down to 0.7 mm from the surface can be observed after attachment of a special adapter to the specimen. Objective: LUMPlanFL 60xW/IR Hiroaki Waki, Tomomi Nemoto, and Junichi Nabekura National Institute for Physiological Sciences, National Institutes of Natural Sciences, Japan Single photon image Tomomi Nemoto National Institute for Physiological Sciences, National Institutes of Natural Sciences, Japan Haruo Kasai Center for Disease Biology and Integrative Medicine, Faculty of Medicine, University of Tokyo, Japan Multi photon image 1

More e efficient ficient fluorescence Streamlined optical system offers enhanced multi photon performance The FV1000MPE offers aberration correction over a wide range from the visible spectrum to the near-infrared range, thanks to its integrated optical design featuring a dedicated IR laser port, pupil projection lens and objectives. Because every optical element was designed with multi photon imaging in mind, the optical system functions efficiently, and allows better optical penetration when using near-infrared lasers. Olympus provides a full line of water immersion objectives designed for near-infrared imaging, including the five most often-requested objectives. Numerical aperture Working distance (mm) XLUMPlanFl 20 x W 0.95 2.0 LUMPlanFl 40 x W/IR 0.80 3.30 LUMPlanFl 60 x W/IR 0.90 2.00 LUMFL60 x W 1.1 1.5 UPlanSApo60 x W 1.2 0.28 Efficient fluorescence acquisition via non-descanned detector system With regular confocal systems, returning fluorescence emissions traveling from deep within a specimen can become dispersed through the specimen and degrade acquisition efficiency. But the FV1000MPE provides more efficient detection with minimal loss using an external two-channel photomultiplier detection system placed close to the specimen. The system provides effective fluorescence detection without the need for a pinhole for de-scanning, because fluorescence excitation occurs only in the confocal plane. Dichromatic mirrors are used in the light path to separate the light going to the two photomultiplier tubes; the mirrors and filters can be changed easily according to the specimen s fluorescence emission characteristics. External photomultiplier CH2 CH1 Use of a femtosecond pulsed IR laser In multi photon excitation, a pulsed laser is used to increase photon density in the focal plane. Fluorescent molecules can be efficiently detected even at low emission levels by using a femtosecond pulsed laser. Either a Mai Tai (Spectra-Physics, a unit of Newport Corporation) or Chameleon (Coherent, Inc.) laser with PC-controlled wavelength adjustment can be adapted. Mai Tai Chameleon Optics adapted following lasers Manufacturer Model Wavelengths covered Spectra-Physics Mai Tai XF-1 710 920 nm Mai Tai XF-950 710 950 nm Mai Tai BB 710 990 nm Mai Tai HP 690 1020 nm COHERENT Chameleon 210 720 950 nm Chameleon XR 705 980 nm Chameleon Ultra II 680 1080 nm 2

Optimal for in vivo observation up to several hundred µm deep The FV1000MPE s streamlined light path involving fewer optical elements permits the microscope to operate with far less laser attenuation. The heightened rate of penetration allows deeper observation of in vivo and thickly sliced specimens. Single photon Multi photon 40µm 90µm 320µm Z-stack image of neurons and glial cells in layers II and III of the cerebral cortex of a rat under anesthesia. Magenta: glial cells (astrocytes) marked by specific fluorescence marker Sulforhodamine 101, Green: neurons and glial cells, Ca-sensitive fluorescent dye Oregon Green 488 BAPTA-1 200 µm. Norio Takata, Hajime Hirase Neuronal Circuit Mechanisms Research Group, Riken Brain Science Institute, Japan XYZ images of mouse brain sections expressing GFP, comparing single-photon 488 nm excitation and two-photon 910 nm excitation. With single photon excitation, tissue can be observed only to a depth of about 90 µm, but with two photons, observation to a depth of about 320 µm is possible. Items displayed in color are vertical cross sections of 3-dimensionally constructed images. Specimens provided by: Kimihiko Kameyama, Tomoyo Ochiishi, Kazuyuki Kiyosue, Tatsuhiko Ebihara Molecular Neurobiology Group, Neuroscience Research Institute, National Institute of Advanced Industrial Science and Technology, Japan Dil Cerebellar slices (XZ scan) Single-photon Two-photon Single-photon Two-photon Molecular layer Granular layer Image of cerebral blood flow of a rat under anesthesia. Cerebral blood flow FITC-dextran 50-350 µm Z-stack image. Hajime Hirase Neuronal Circuit Mechanisms Research Group, Riken Brain Science Institute, Japan Vertical cross sections of the mouse cerebellum molecular layer (L) and granular layer (R) marked with DiI and obtained by XZ scans using single-photon 488 nm and two-photon 720 nm excitation. Multiphoton excitation's superiority to confocal observation is apparent in deep observation of brain slices. Yasuyuki Hayakawa, Haruo Kasai Center for Disease Biology and Integrative Medicine, Faculty of Medicine, University of Tokyo 3

F V 1 0 0 0 M P E A P P L I C A T I O N S Living pancreatic islet of Langerhans stained with FM1-43 lipid-soluble fluorescent dye. The cell membrane structure of the islet of Langerhans can be readily observed, and growth of the membrane area accompanying insulin exocytosis of a single insulin granule can also be observed. Noriko Takahashi, Haruo Kasai Center for Disease Biology and Integrative Medicine, Faculty of Medicine, University of Tokyo 3-dimensionally constructed image of cgmp-containing cells marked with CY3 running along the antenna nerve of the silkworm. 200 µm projection image. Hitoshi Aonuma Research Institute for Electronic Science, Hokkaido University, Japan Cells distributed in the CA1 region of the hippocampus (Mouse embryo with the GFP gene introduced in utero) Cell body and projections of a neural progenitor cell (Mouse embryo with the GFP gene introduced in utero) Akira Mizoguchi Department of Neural Regeneration and Cell Communication, Faculty of Medicine, Mie University Cell body and projections of a neural progenitor cell (Mouse embryo with the GFP gene introduced in utero) Neural progenitor cell: GFP (green) Actin fibers: Phalloidin-Alexa 594 (red) Visualization of erythrocytes following the blood flow in the brain and vascular endothelial cells in a GFP-actin transgenic mouse XYT (time interval 148 ms) Akira Mizoguchi Department of Neural Regeneration and Cell Communication, Faculty of Medicine, Mie University 4

Scanning specific areas using optimal pulse width The FV1000MPE can handle applications using multiple points or regions of interest through highspeed toggling ON/OFF of the laser with an acousto-optic modulator (AOM). In addition, the system s negative chirp enables highly efficient multi photon excitation. What is negative chirp? In microscopes, dispersion through the optics causes delays in laser pulse components, which in turn can create problems with multi photon imaging. By narrowing the pulse width of the laser (also called creating a negative chirp), the beam emerging from the objective is adjusted so that the optimal width of the pulse is nearly restored. This negative chirp results in ultra-short pulses of light for multi photon excitation, and helps reduce specimen damage. General multi photon laser microscope Microscope Multi photon laser microscope with negative chirp Negative chirp Microscope Multi photon simultaneous imaging and laser stimulation Laser light stimulation can be adjusted as desired without the user being limited by imaging settings. The FV1000's SIM scanner for laser light stimulation, which is independent of the scanner for observation, is available. A multi photon laser provides simultaneous excitation of the same focal plane as that used in imaging. Calcium signal of a single dendritic spine examined by two-photon uncaging and fluorescence a) Stacked fluorescent image of dendritic spines in the hippocampus (excitation of 830 nm). Whole-cell recording was performed, and Alexa 594 and the calcium indicator OGB-5N were injected. At the head of the single spine (red), two-photon uncaging of caged glutamate was performed and glutamate was administered (excitation of 720 nm). A line scan was performed on the line (the line linking the 2 triangles) from the head of this single spine toward the dendritic trunk. b), c) Simultaneous line scanning for Alexa 594 and OGB-5N. d) Calcium concentration determined from the fluorescence emission ratios of OGB-5N and Alexa 594. e) Changes in calcium concentration at the head of the spine (H, black), changes in calcium concentration at the dendritic trunk (D, red), current from whole-cell recorded NMDA receptors (INMDA). Calcium flow into the trunk via NMDA receptors at the head of the spine is apparent from these observations. Reprinted from Noguchi et al. Neuron 46(2005)609-622. Jun Noguchi, Haruo Kasai Center for Disease Biology and Integrative Medicine, Faculty of Medicine, University of Tokyo Uncaging area Single photon uncaging Multi photon uncaging 5

F V 1 0 0 0 M P E A P P L I C A T I O N S Three types of optics are available for multi photon laser integration. Basic system Optimized for in vivo imaging, this system allows deeper sections of specimens to be viewed using the multi photon laser. The optics are designed to have the beam enter the pupil of the objective efficiently. Precise adjustment of the light intensity is possible through use of a highly durable λ/2 Plate & Glan-Thompson prism. The system features a streamlined, compact design to save valuable laboratory space. 1200 Fixed stage upright microscope with motorized focusing BX61WI system layout Unit: mm Laser power source Chiller 1800 608 Laser rack for visible light lasers PC rack 900 900 2100 3000 AOM system The AOM module allows high-speed ON/OFF powering of the laser. Local laser radiation of regions of interest is possible, so the FV1000MPE can be used in experiments requiring laser light stimulation, such as photoconversion. Negative chirp comes standard, so efficient multi photon excitation can be achieved with relatively weak excitation light. Motorized inverted system microscope BX61WI/IX81 system layout Unit: mm 2400 900 900 608 Laser rack for visible light lasers PC rack 2400 Chiller Laser power source 1500 3600 MPE-SIM system Multi photon lasers have been integrated in the imaging unit as well as in the scanner for laser light stimulation. With multi photon excitation, excitation occurs only in the focal plane, so there is minimal bleaching. Thus, laser light stimulation of a specific site can be performed in a localized manner, in three dimensions. Additionally, this set of optics is equipped with two AOM modules, and exact laser light stimulation of the targeted area may be achieved in 2 dimensions. (Use of the single photon laser for laser light stimulation by attaching it to the dedicated scanner for laser light stimulation is not possible while imaging with the multi photon laser.) Fixed stage upright microscope with motorized focusing BX61WI with SIM scanner system layout 2700 1500 Unit: mm Chiller Laser power source 1800 900 900 Laser rack for visible light lasers PC rack 608 Chiller Laser power source 3000 3900 IR pulsed laser for Stimulation λ2 IR pulsed laser for imaging λ1 6

FV1000MPE specifications Basic system AOM system MPE-SIM system Single photon Visible light laser LD laser: 405nm: 50mW, 440nm: 25mW, 473nm: 15mW, 559nm: 15mW, 635mW, 20mW, laser unit Multi Ar laser (457nm, 488nm, 515nm, Total 30mW), HeNe(G) laser (543nm, 1mW) Modulation: Continuously adjustable via an AOTF (0.1 100% in 0.1% increments) Operating mode: Allows laser turn-off during the retrace period, adjustment of laser power for a given region, and selection of the laser and selection of the laser wavelength AOTF laser combiner Visible light laser platform with implemented AOTF system, ultra-fast intensity with individual laser lines, additional shutter control Connected to scanner via single-mode fiber Equipped with laser feedback mechanism to limit changes in laser light intensity over time Multi photon Multi photon near-infrared For the adjustable wavelengths of a mode-locked Ti:sapphire laser (femtosecond), laser unit pulsed laser refer to additional lasers that can be used on page 6: Mai Tai (Spectra-Physics) or Chameleon (COHERENT) Can be directly connected to a scanner via Olympus' optics integrating a multi photon near-infrared pulsed laser Multi photon near-infrared pulsed laser power unit, water-cooled circulating chiller Optics integrated Integrates a multi photon near-infrared pulsed laser in the scanning unit Laser safety measures implemented via a protective cover for laser safety Shutter/attenuator λ/2 Plate & Glan-Thompson prism AOM AOM x 2 Scanning unit Basic configuration Detector: 3 channels for fluorescence detection (photomultipliers), 1 channel for transmitted light detection (photomultiplier) Laser ports: visible-light laser port (integrated by fiber), multi photon near-infrared pulsed laser port (directly integrated) Dichromatic mirrors for excitation, dichromatic mirrors for multi photon excitation, dichromatic mirrors for fluorescence, emission filter, infrared cut filter: using a high-performance filter A filter or spectral type of fluorescence detector can be selected Spectral type: Channels 1 and 2 provided with independent grating and slit Selectable wavelength range: 1 100 nm, wavelength resolution: 2 nm, wavelength switching speed: 100 nm/ms Scanning method Light deflection via 2 galvanometer scanning mirrors Scanning modes Pixel size: 64 x 64 4096 x 4096 pixels Scanning speed: (pixel time): 2 µs 5ms High-speed scanning mode: 16 frames/sec (256 x 256) Dimensions: Time, Z, (wavelength) (or any combination thereof) Line scan: straight line (includes rotation), free line, point XY scan Photo detection method Analog integration Pinhole Single motorized pinhole, adjustable in 0.5 µm increments Field Number 18 Zoom size 1 50x (adjustable in 0.1x increments) External detector External detector: photomultiplier (2 channels) SIM scanner unit For single photon laser (optional) For single photon laser (optional) For multi photon laser Vibration isolation table size Large vibration isolation table for a multi photon near-infrared pulsed laser 1,800(W) x 1,200 (D) mm 2,400(W) x 1,500 (D) mm 3,000 (W) x 1,500 (D) mm Microscopes Motorized microscopes BX61WI BX61WI/ IX81 BX61WI System control OS: Windows XP Professional (English version) CPU: Pentium IV 3.2GHz or larger Memory: 2.0GB or larger Hard disk: 120GB or larger Dedicated I/F board: built-in PC Graphics board: Open GL-compliant Recording media: Equipped with DVD dual drive Monitor: two SXGA 1280 x 1024 19-inch monitors Software FV10-ASW Required installation environment Room temperature: 20 C 25 C ± 1 C, humidity: 60% or less, dust level: Class 10000, requires continuous (24-hour) power supply Power source environment AC100-120/220-240V 60VA For details, refer to supplied environmental specifications *The cover page shows an FV1000MPE BX61WI system The use of lasers with SUB-PICOSECOND pulses for two-photon microscopy is protected by US Pat No. USP5034613, JP Pat No. JP2848952B2, EU Pat No. EP500717B2, EU Pat No. EP807814B1. This technology are under a license from Carl Zeiss MicroImaging GmbH and Cornell Research Foundation Inc. Certified ISO 14001 by UKAS ENVIRONMENTAL MANAGEMENT 008 ISO9001 Certification OLYMPUS CORPORATION Micro-Imaging System Division IISO14001 Certification OLYMPUS CORPORATION Ina-Plant ISO9001/ISO14001 Certification Olympus Optical Technology Philippines Inc. OLYMPUS CORPORATION has obtained ISO9001/ISO14001 Specifications are subject to change without any obligation on the part of the manufacturer.