AQUACIAT. Inverter Heat pump. Use. Range

Similar documents
ECOCIAT. Domestic hot water heat recovery unit

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Condensing unit type EPSILON-ECHOS LE Technical information manual

Cool Design for Homes and Offices

CRAC Precision climate control units for data centres

Cooling kw Heating kw

Technical data. Danfoss DHP-A

HP switch LP switch Discharge thermo Comp. Surface thermo

MAC-120HE-01 Air-Cooled Chiller

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

TWE+TTA TWE+TWA T.R.

YCAA-B AIR COOLED LIQUID CHILLER

Test Report issued under the responsibility of:

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

marine/bespoke split applications

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Rotary screw compressors kw 5,5 7, , bar MODULO

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Hot Water. Heat pump water heaters. Residential and Commercial R410a

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE


Refrigeration Compressed Air Dryer Buran Ultrapulse

3Aftermarket Systems. Air Conditioners and Kombos Heater/Pressurizer System Matrix Aftermarket System Requirements...

ELECTRIC CENTRAL HEATING FLOW BOILER

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

york air-conditioning products Residential & VRF News 2015

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

D SERIES MODULAR AIR-COOLED SCROLL CHILLER. TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Failure code manual. content

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Air cooled screw chillers

14. Troubleshooting Guide

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

MAROON kw. General information. Unique selling points

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Unico Inverter. Unique and efficient.

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SMM. Installation Operation Maintenance

Electric Flow Boiler

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Chilled Water Precision Air Conditioner For Critical Application

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

HERZ-Thermal Actuators

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

PANASONIC TROUBLE SHOOTING GUIDE

Diesel Engine Driven Generators Page 1 of 6

Versati Air to Water Heat Pump

SECTION HEAT PUMPS

SECTION AIR COOLED WATER CHILLERS

Magnum Mobile Generator MMG55 Specifications

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

DESIGN STANDARDS SECTION

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

KONRAD. Hybrid Fancoil Series

Appendix - Controllers 179

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Aerona Air Source Heat Pumps

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

ALL IN ONE. Heat Pump Water Heater

HEAVY DUTY STORAGE GAS

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

SWIMMING POOL HEAT PUMP Owners Manual

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

Transformer oil cooler ALFA A02

WWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections

Test Code: 8297 / Version 1

Oil and Coolant Circulating Heating System. Model - OCSM

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

RPV - RP - RA air handling units

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

On/off room thermostats range. On/off V30 range. Master/slave PI V200 range. V3000 KNX networked PID range

Transcription:

High energy efficiency with the R410A Compact and silent Scroll compressors technology High performance brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 40 to 50 kw Heating capacity: 45 to 50 kw Cooling and heating Hydraulic module Heat recovery ENVIRNMENTALLY HFC R410A PRTECTIN DE FRIENDLY L'ENVIRNNEMENT Use The IVDC series packaged water chillers or heaters are medium-capacity units specifically designed for heating and air conditioning applications in ffices, Healthcare, Administration, Shopping Centres and the Residential sector. These standard packaged units are designed for outdoor installation and require no special protection against adverse weather conditions. To operate in HEATING or CLING mode, they use the outdoor air as the only external source; this permits the evacuation of heat in summer or the supply of thermal energy for heating in winter. Connected to an underfloor heating or cooling system, fan coil units or an air handling unit, the reversible GRAND INVERTER IVDC series is an extremely easy way to heat and air condition buildings. Each unit is delivered fully assembled, wired (control and power), charged with refrigerant and factory tested. Simply make the necessary electrical and hydraulic connections, and your unit is ready to operate. Range IVDC series Reversible Air/Water modules with hydraulic system (circulation pump). HEAT PUMPS- AIR CNDITINING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 12.639 C 1

Description The IVDC series is supplied as standard with the following components: - air-source condenser with axial fan motor inverter and variable speed inverter, - high efficiency brazed-plate heat exchangers, - chilled water or hot water capacity control, - control, automatic operation and startup box:. Electrical supply: Three-phase 50 Hz - 400 V (+6%/-10%) + Earth. Control circuit: Single-phase 50 Hz - 230 V (transformers fitted on unit as standard), - casing for outdoor installation. n Complies with European directives (EC): - Machinery directive (98/37/EC) - EMC directive (2004/108 EC) - Pressure equipment directive (97/23/EC, category 2) - Low voltage (2006/95/EC) n Compliance with standards - EN 60204, EN 378-2 (NFC 15-100, France) Standard and ptional Equipment IVDC Power supply: 400 V, 3-Phase, 50 Hz, without neutral, with transformer Coil protection screen Resilient mounts Main disconnect switch Water flow regulator Phase monitor (reversal, loss, over- and undervoltage) Soft start Variable-speed condenser fan Connection frame/duct (XTRAFAN) Sleeve + connection duct/duct (XTRAFAN) 800 micron water filter All-season operation (-20 C) Remote control Additional voltage-free contacts board LNWRKS Protocol MULTICNNECT multiple unit management Partial heat recovery - desuperheater Frost protection BLYGLD coated coil Polyurethane coated coil fins Hydraulic control kit (manifold, control & shut-off valve) Hydraulic hoses Double pump / 200 15 kw electric auxiliary heater kit è 150 15-30 - 45-60 kw electric auxiliary heater module kit / 200 External auxiliary heating management (4-stage) : Supplied as standard : ption Note: Some technical options not listed above may be added on special request (please contact us). 4 HEAT PUMPS- AIR CNDITINING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 12.639 C

Technical data - Reversible heat pumps IVDC 150 V 200 V Net cooling capacity (1) kw 36,77 47,32 Net power input kw 13,86 18,01 Energy efficiency rating (EER) 2,65 2,62 Seasonal energy efficiency rating (ESEER) 3,81 3,72 Lw/Lp (3) (HP high performance version) db(a) 78,5 / 46,5 75,9 / 43,9 Lw/Lp (3) (HT high temperature version) db(a) 86,3 / 54,3 86,3 / 54,3 Net heating capacity (1) kw 41,24 53,49 Net power input kw 13,92 16,73 CP/CP performances 2,96 3,19 Compressor hermetic SCRLL Start-up mode Direct using Soft Starter Number 1 Power control % Variable from 33 to 100% Refrigerant oil type Polyester PE 160 SZ il capacity l 3 3.3 No. of refrigerant circuits 1 Refrigerant (GWP) kw eq. C2 R410A (1720) Refrigerant load kg 9.5 14.8 Electrical supply ph/hz/v Three-phase 50 Hz 400 V (+6%/-10%) + Earth Machine protection rating IP 44 Control circuit voltage ph/hz/v Single-phase 50 Hz 230 V (+6%/-10%) - transformer fitted Evaporator Brazed plate exchanger(s) Water capacity l 3.11 7.71 Chilled water outlet temp. (min./max.) C -10 / +15 Hot water outlet temp. (min./max.) C +30 / +55 Minimum water flow rate m 3 /h 5.1 6.9 Maximum water flow rate m 3 /h 13.1 17.6 Water connections Ø 1 ½ M 2 M Max. pressure. water end bar IVDC 4 bar Air-cooled condenser Finned heat exchanger Fan Ø mm 800 HP High Performance Version- No. x motor capacity no. x kw 1 x 1.143 1 x 1.066 HP High Performance Version - Air flow rate m 3 /h 15.500 16.100 HP High Performance Version - Rotational speed rpm 690 690 HT High Temperature Version- No. x motor capacity no. x kw 1 x 2.443 1 x 2.443 HT High Temperature Version - Air flow rate m 3 /h 23.000 23.500 HT High Temperature version - Rotational speed rpm 985 985 Min. water volume (IVDC) l 74 96 Expansion vessel C l 6 12 Maximum capacity of system in litres (4) Pure water Maximum capacity of system in litres (4) Glycol/water mix max. water 36 C (5) 550 1100 max. water 46 C (5) 325 650 max. water 36 C (5) 390 780 max. water 46 C (5) 230 460 Standard pump Qty. 45 40 Height (excluding mounts) mm 1423 1773 Length (IVDC) mm 1995 Depth mm 1055 Weight (empty) kg 450 620 Storage temperature C +50 C (1) HP High Performance version capacities based on: a/ CLING: +12 C/+7 C and condenser air inlet temperature of +35 C at nominal air flow b/ HEATING: hot water outlet at +45 C and external air at +7 C DB, 86% RH (EN 14511 and EURVENT conditions) (2) Net EER/CP values (3) Lw: verall sound power level as per IS3744 Lp: verall pressure levels measured at 10m in a free field, calculated using the formula LP=Lw-10 log S(4) System capacity depending on expansion vessel fitted on unit (5) Water temperatures given are those which can be reached when the machine is off HEAT PUMPS- AIR CNDITINING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 12.639 C 5

Main components n Casing - Removable galvanised metal panels, - RAL 7024 and RAL 7035 lacquer coating n Hermetic SCRLL compressors - Built-in electric motor cooled by suction gases - Motor protected by internal winding thermostat - Placed on anti-vibration mounts - Continuously variable power from 33 to 100% n Evaporator - Brazed plate exchanger(s) - End and inside plates in AISI 316 stainless steel - High performance, optimised plate patterns - Thermal insulation n Condenser - High efficiency air-cooled exchanger, aluminium fins with optimised profiles and grooved copper tubes - Condenser or evaporator mode heat exchanger on IVDC reversible heat pumps - Axial fans with aluminium airfoil blades. - Variable speed motors with electronic switching- IP 54, class F n Control functions and safety devices - Water flow control - Electronic expansion valve - Refrigerant high and low pressure safety devices - Safety valves on refrigeration circuit - Temperature and pressure sensors - Evaporator water flow controller - Unit start-up sequence - Phase controller Electronic control module CIAT electronic control module with microprocessor and CPU, with central automatic operation and access to internal operation states. n Features: - Start, stop, reset or remote control, - CLING or HEATING mode selector, - RS485 output for GTC link (ModBus-JBus),. board adapter for additional voltage-free contacts,. remote control adapter (optional) - Multilingual analogue LCD display and LEDs. n Functions: - operation information displayed via:. multilingual clear-text messages. direct temperature and pressure readings - complete management of compressors with start-up sequence, timer and runtime balancing - Self-adjusting and proactive functions with adjustment of settings drift control - Device for adapting the capacity to meet the cooling or heating requirements, checked against the water temperatures - Monitoring of internal operation parameters - Second setpoint management - Direct display of water and pressure temperatures - Diagnosis of operation and fault states: HP/LP, water flow, compressor motor(s), frost protection - Short-cycle protection - Remote management and remote monitoring n Electrics box The fully wired electrics box which houses all the electrical components and the electronic CPU board, controls the entire unit, monitors its operation, adjusts water setpoints and interfaces with an external control system. It comprises: - Control and power circuits, - Wire numbering, - Main safety switch with handle on front, - Control circuit transformer, - Circuit breakers on the power and control circuits, - Compressor and motor switches, - Main earth connection, - Microprocessor-controlled electronic control unit, - Alarm or information signals on free terminals. ptions (kit for installation on site) n Main options - Additional voltage-free contact boards, - Remote control unit, - MULTICNNECT management of up to 8 units. - LNWRKS protocol (gateway) - Frost protection, - Evaporator and condenser flexible couplings, - Hydraulic control kit including manifold pressure gauges, control valve and shut-off valve, - Double pump for models 200-15 kw auxiliary electric heater kit (IVDC 150). - 15-30-45-60 kw auxiliary electric heater Kit MDULE (IVDC 200). - Management of 4 auxiliary heating devices. HEAT PUMPS- AIR CNDITINING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 12.639 C 7

Dimensions IVDC model 150 135 50 974 x 957 (int) connection sleeve (option) Connection frame (option) 2070 819 1055 1995 148 4 removable lifting lugs 20.5 x holes 1157 E 192 120 x 4 1423 Xtrafan 120 1321 6 5 2 1 Wooden handling blocks, to be removed after fitting C D B D A 548 1045 527 1145 x 840 1984 Leave a space of 1 metre around the unit for maintenance utdoor air discharge utdoor air intake 5: G ½ male hot water inlet 6: G ½ male hot water outlet 1: G 1½ male chilled water inlet 2: G 1½ male chilled water outlet E: Electrical supply (x 80) Position of mounts Anti-vibration mounts Weight (kg) A B C D empty in operation IVDC 150 300 1147 300 P25 50 x 120 450 454 24 HEAT PUMPS- AIR CNDITINING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 12.639 C

Dimensions IVDC models 200 819 1055 135 50 974 x 957 (int) connection sleeve (option) Connection frame (option) 2070 1995 113 203 423 120 x 3 1773 Xtrafan 1671 5 6 1 2 4 removable lifting lugs 20.5 x holes C E B E 1145 D A 120 548 Wooden handling blocks, to be removed after fitting 1044 527 x 900 1988 Leave a space of 1 metre around the unit for maintenance utdoor air discharge utdoor air intake 5: G1 male hot water inlet 6: G1 male hot water outlet 1: G 2 male chilled water inlet 2: G 2 male chilled water outlet E: Electrical supply (x 80) Position of mounts Anti-vibration mounts Weight (kg) A B C D E empty in operation IVDC 200 100 1188 350 P25 50 x 200 P25 50 x 150 620 625 HEAT PUMPS- AIR CNDITINING - REFRIGERATIN - AIR HANDLING - HEAT EXCHANGE - NA 12.639 C 25