Cable sockets for controlling electrically operated valves and sensors

Similar documents
Coils - Connectors. Coils Connectors. Summary. RE /03.16 Replaces: RE / Description

Electrical connection technologies Electrical connectors Electrical connectors with cable, series. Brochure

Cable Plug acc. to DIN EN , Form A

mpm DIN CONNECTORS

400 Series Buccaneer BUCCANEER POWER. bulgin

Coils - Connectors. Coils Connectors. Summary. RE / /10 Replaces: RE / Description

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

7000 Series Buccaneer

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

2/2 and 3/2 Way Size 6 Seat Valves

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Line-Mounted Valves L Series

Fixed displacement vane pumps

3/2- and 2/2-way cartridge valve type BVE

Liquid Level Limit Switch liquiphant T FTL 20

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

3/2 Solenoid Cartridge Valve, Size 6

Proportional pressure regulators VPPE

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

Single sub-base valve

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Solenoid Valve Island Type 3965

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Digital input modules

Product and functional description

HERZ-Thermal Actuators

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Electro-hydraulic pressure switches type DG

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Analog Command Value Card Type VT-SWKA-1

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Series 7500 Torque Sensor

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

PowerLine. Single Pole Connectors

Operating instructions IV / 2007

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

System 8. ü ( System 8

Givare NC-SRS 280 och 880

RM4TG20 three-phase network control relay RM4-T - range V

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Inductive sensor NI10-M18-Y1X-H1141

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Electronic Pressure Switch EDS 3000

Electric Rotary Actuator - On/Off or programmable control actuator

Product Information. HMC 6 Hybrid Motor Cable

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Conductive Level Switch FK 2 Technical Data:

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

ELECTRICAL PLUG TYPE CONNECTIONS

Directional seated valves type VP 1

Pressure reducing valve, direct operated, Type ZDR 6 D

Thermal-Magnetic Circuit Breaker M1-..

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Industrial circular connectors

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Pressure transmitter For general industrial applications Model A-10

Proximity Switches RS (Reed Switch)

Universal MATE-N-LOK Connector System

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

HARTING Ethernet Cabling 8-poles Overview

Digital Keypad Use s Manual

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Adjustment functions for both span and shift have been incorporated

48 SERIES Relay interface modules 10 A

Universal plug connectors, for self-assembly

Turbine Flow Sensor Series VTR

Capacitive Prox E2K-X

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Cross-beam scanning system to detect slim objects. 100 mm in

TECHNICAL DATASHEET Incremental Encoder RI 58-H

Elektromotoren und Gerätebau Barleben GmbH

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

gesis IP + Heavy Duty Class I, Zone 2

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Electronic Pressure Switch EDS 300

ACS-30-EU-EMDR-10-MOD

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

38 Series - Relay interface modules A

3 Port Solenoid Valve

Linear Luminaire with LED Series EXLUX 6402/2

Digital inductive conductivity transmitter

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Rotary actuators Rotary wing drives Series RAK. Brochure

5SV Residual Current Protective Devices

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Series 6000 Torque measured metal bellow coupling

Transcription:

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Cable sockets for controlling electrically operated valves and sensors H554 Cable sockets according to DIN EN 7530-803 and ISO 4400, -pin+, with standardised connecting cable, for electrically operated valves with component plug "K4" Table of contents H5744 Cable sockets for mechanical position switches and valves with central connection with component plug "K6" / "K" Contents Page Individual connection Cable sockets according to DIN EN 7530-803 and ISO 4400, -pin + for electrically operated valves with component plug "K4" Cable sockets according to DIN EN 7530-803 and ISO 4400, -pin + 4 with standardised connecting cable for electrically operated valves with component plug "K4" Cable sockets for electrically operated directional valves with component plug "C4" (AMP Junior-Timer) 6 Cable sockets for electrically operated directional valves with component plug "K40" (Deutsch plug) 7 Cable sockets according to DIN EN 7530-803 and ISO 4400, 3-pin + 8 for pressure switches with component plug "K4" Cable sockets according to DIN EN 7530-803 and ISO 4400, 3-pin + 0 with standardised connecting cable for pressure switches with component plug "K4" H 5743 Cable sockets according to IEC 60947-5-, for valves with inductive position switch "QM" and valves with component plug "K4" RE 08006/0.05 Replaces: 03.03 H 5745 /4 Cable socket according to DIN EN 7530-803 and ISO 4400, -pin+, for electrically operated valves with component plug "K4" Contents Page Central connection (terminal box) Cable sockets for mechanical position switches and valves with central connection with component plug "K6" / "K" Cable sockets according to IEC 60947-5- 3 for valves with inductive position switch "QM" and valves with component plug "K4"

/4 Bosch Rexroth AG Industrial Hydraulics Cable sockets RE 08006/0.05 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Cable sockets according to DIN EN 7530-803 and ISO 4400, -pin + for electrically operated valves with component plug "K4" Ordering code Designation: Cable socket Z4 DC voltage AC voltage Colour Valve side Fitting Ma te ri al number Symbol 40 V grey A M6 x.5 R900700 40 V black B M6 x.5 R90070 Z45 40 V brown A NPT /" R90000483 40 V black B NPT /" R9000039 Standard without circuitry Z5L 40 V black A/B M6 x.5 R90070 Z55L 40 V black A/B NPT /" R900057453 With indicator lamp ge Z5L With indicator lamp and Z-Diodenprotective coating Z5L With indicator lamp and protective diode + - ge ge + - 4 V black A/B M6 x.5 R900706 Limitation of cut-off voltage peak to 55 V 4 V black A/B M6 x.5 R900707 Limitation of cut-off voltage peak to V RZ5L 4 40 V black A/B M6 x.5 R900709 RZ55L + 4 40 V black A/B NPT /" R900057455 With indicator lamp and rectifier ge - RZ5 4 40 V black A/B M6 x.5 R900705 RZ55 + 4 40 V black A/B NPT /" R90084566 With rectifier -

RE 08006/0.05 Cable sockets Industrial Hydraulics Bosch Rexroth AG 3/4 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Technical data (for applications outside these parameters, please consult us!) Ambient temperature Standard C 40 to + 5 With indicator lamp/ rectifier Type of protection according to DIN 40050 C 0 to + 60 IP 65 with cable socket mounted and locked Operating voltage V See ordering code on page Maximum operating current Standard A 6 With indicator lamp A 4 With rectifier A,5 Current consumption of LED ma approx. 0 LED Number of pins Yellow + Clamping range for cables having an outer diameter of mm 5, up to 0 Maximum cable cross-section mm.5 Type of connection Unit dimensions: Without circuitry (in mm) 8 0A 50V 7,5 GDM 43 0 Fixing screw M3, tightening torque M T = 0,5 Nm Fitting, see page 34, 5,5 Threaded connection Unit dimensions: With circuitry (in mm) 8 8 8 45 40 5,5

4/4 Bosch Rexroth AG Industrial Hydraulics Cable sockets RE 08006/0.05 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Cable sockets according to DIN EN 7530-803 and ISO 4400, -pin + with standardised connecting cable for electrically operated valves with component plug "K4" Ordering code Designation: Cable socket Z4 Standard without circuitry Z4L With indicator lamp sw sw gnge sw sw gnge Symbol DC AC Material number for cable length voltage voltage Colour 3 m 5 m 0 m 40 V black R9000300 R9000304 R900734 4 V black R90003050 R9000308 R900735 90 30 V black R9000303 R900030 R900736 80 40 V black R9000304 R9000300 R900737 Z4L sw 4 V black R900030 R9000305 R900738 With indicator lamp and Z-Diodenprotective coating sw Limitation of the cutoff voltage peak to 55 V gnge Cable sockets with indicator lamp are provided with a yellow LED that signals the operational state. With cable sockets with indicator lamp and 4 V suppressor circuit, the cut-off voltage peak is limited to approx. 55 V by a zener diode circuit. The cable socket s scope of supply includes a fixing screw and a flat seal (both captive). Technical data (for applications outside these parameters, please consult us!) Ambient temperature Cable socket housing C 0 to + 90 Type of protection according to DIN 40050 Connecting cable Rigidly mounted cable C 0 to + 80 Flexibly mounted cable C 5 to + 70 Wire cross-section mm 3 x.0 Wire marking Green/yellow Number of pins IP 67 with cable socket mounted and locked Ölflex 50 PVC, grey, with approbation: VDE, UL, CSA, SEV Other wires Black with figures. On the -pin electrical connection to DIN EN 75 30-803, contacts and are assigned. + Cable cross-section mm approx. 7

RE 08006/0.05 Cable sockets Industrial Hydraulics Bosch Rexroth AG 5/4 Unit dimensions (in mm) Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com 7 8 30 7 47 4 3 5 LED DIN contacts, rotatable through 0 + 80 3 Flat seal (captive) 4 Nameplate 5 Fixing screw M3 (captive), tightening torque M T = 0.5 Nm

6/4 Bosch Rexroth AG Industrial Hydraulics Cable sockets RE 08006/0.05 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Cable sockets for electrically operated directional valves with component plug "C4" (AMP Junior-Timer) Ordering code Designation: Cable socket Outer wire diameter in mm Colour Material number POL AMP JUNIOR D.. to 3.0 black R9007 POL AMP JUNIOR D.. to. black R90033533 Technical data (for applications outside these parameters, please consult us!) Ambient temperature range C 0 to + 5 Permissible operating voltage range V DC 0 to 3 Type of protection according to EN6059 Maximum operating current A 5 Number of pins Permissible outer cable diameter mm 5. to 7 Maximum wire cross-section mm 0.5 to Permissible outer single wire mm. to 3 Type of connection Condition when delivered Crimping tool Unit dimensions (in mm) Housing AMP Type 889-9,5 54 IP66A (correctly mounted and locked) Crimped connection plug housing, contacts, single wire seal, rubber sleeve, not assembled, packed in a bag Basic crimping tool type 539635-, make: AMP Matrix type 539737-, make: AMP 37,5 5 A 7 A A-A 3,8±0,3

RE 08006/0.05 Cable sockets Industrial Hydraulics Bosch Rexroth AG 7/4 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Cable sockets for electrically operated directional valves with component plug "K40" (Deutsch plug) Ordering code Designation: Cable socket Wire cross-section Colour Material number POL DT06 K40AWG4*BG AWG4-6 grey R90073345 POL DT06 K40AWG6*BG AWG6-8 grey R9007847 Technical data (for applications outside these parameters, please consult us!) Plug housing 6 6 DT06-S-CE0 Ambient temperature range C 0 to + 5 Permissible operating voltage range V DC 0 to 3 Type of protection according to EN6059 Maximum operating current A 5 Number of pins Maximum wire cross-section AWG4-6 mm.3 to.08 AWG 6-8 mm 0.8 to.3 Permissible outer diameter single wire mm.35 to 3.05 Type of connection Condition when delivered Crimping tool Unit dimensions (in mm) IP69K (correctly installed and locked) Crimped connection plug housing, contacts, securing wedge, not assembled, in bag Type HDT-4800, make: Compagnie Deutsch 3

8/4 Bosch Rexroth AG Industrial Hydraulics Cable sockets RE 08006/0.05 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Cable sockets according to DIN EN 7530-803 and ISO 4400, 3-pin + for pressure switches with component plug "K4" Ordering code Designation: Cable socket Symbol Z4 Standard without circuitry 3 3 Z5L With indicator lamp 3 -N Z5L6 With indicator 3 3 lamp ge gn -N ge gn 3 DC voltage AC voltage Colour Fitting Material number 40 V black M6 x.5 R90070 V black M6 x.5 R9007030 4 V black M6 x.5 R9007048 48 V black M6 x.5 R900703 0 V black M6 x.5 R9007035 0 V black M6 x.5 R9007037 4 V black M6 x.5 R9007040 Technical data (for applications outside these parameters, please consult us!) Ambient temperature Standard C 40 to + 5 Type of protection according to DIN 40050 With indicator lamp C 0 to + 60 IP 67 with cable socket mounted and locked Operating voltage V See ordering code above Maximum operating current Standard A 6 With indicator lamp A 4 Current consumption of LED ma approx. 0 Indicator lamp Number of pins Yellow / yellow + green 3 + Clamping range for cables having an outer diameter of mm 5, up to 0 Maximum wire cross-section mm.5 Type of connection Threaded connection

RE 08006/0.05 Cable sockets Industrial Hydraulics Bosch Rexroth AG 9/4 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Unit dimensions: Without circuitry (in mm) 8 34, 5,5 0A 50V 7,5 3 GDM 43 0 Fixing screw M3, tightening torque M T = 0.5 Nm M6 x,5 Unit dimensions: With circuitry (in mm) 8 8 8 3 45 M6 x,5 40 5,5

0/4 Bosch Rexroth AG Industrial Hydraulics Cable sockets RE 08006/0.05 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Cable sockets according to DIN EN 7530-803 and ISO 4400, 3-pin + with standardised connecting cable for pressure switches with component plug "K4" Ordering code Designation: Cable socket Z4 Without circuitry DC AC Material number for cable length Symbol voltage voltage Colour 5 m 0 m sw 40 V black R900698 R900699 sw sw3 3 gnge Z4L sw 4 V black R900508 R9005083 With indicator sw sw3 3 lamp gn ge sw4 gnge Technical data (for applications outside these parameters, please consult us!) Ambient temperature Cable socket housing C 0 to + 90 Type of protection according to DIN 40050 Connecting cable Cable rigidly mounted C 0 to + 80 Cable flexibly mounted C 5 to + 70 Wire cross-section Standard mm 4 x 0.75 With indicator lamp mm 5 x 0.5 Wire marking Green/yellow Number of pins IP 67 with cable socket mounted and locked Ölflex 50 PVC, grey, with approbation: VDE, UL, CSA, SEV Other wires Black with figures. On the 3-pin electrical connection according to DIN EN 75 30-803, contacts, and 3 are assigned. 3 + Cable cross-section mm approx. 7

RE 08006/0.05 Cable sockets Industrial Hydraulics Bosch Rexroth AG /4 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Unit dimensions (in mm) 7 8 30 3 7 47 3 4 LED Flat seal (captive) 3 Nameplate 4 Fixing screw M3 (captive), tightening torque M T = 0.5 Nm

/4 Bosch Rexroth AG Industrial Hydraulics Cable sockets RE 08006/0.05 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Cable sockets for mechanical position switches and valves with central connection with component plug "K6" / "K" Ordering code Component plug Standardisation DC voltage AC voltage Colour Fitting Material number K6 according to DIN 4365 50 V grey Pg R90000803 K not standardised 50 V red Pg R900005538 Technical data (for applications outside these parameters, please consult us!) Ambient temperature C 40 to + 90 Type of protection according to DIN 40050 Operating current, contiuous A 0 Number of pins Component plug K6 6 + Component plug K 4 + Clamping range for cables having an outer diameter of mm 7, up to 9 Maximum wire cross-section mm.5 Type of connection Unit dimensions: Component plug K6 (in mm) max 40 Fixing screw M3, tightening torque M T = 0.5 Nm 5, SW 9,5 5,5 48 0 IP 65 with cable socket mounted and locked Crimped connection Unit dimensions: Component plug K (in mm) 65 9,5 7,5 30 48 0

RE 08006/0.05 Cable sockets Industrial Hydraulics Bosch Rexroth AG 3/4 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Cable sockets according to IEC 60947-5- for valves with inductive position switch "QM" and valves with component plug "K4" Ordering code Designation, features: Cable socket Colour Fitting Material number Cable socket suitable for K4 4-pin, M x with threaded connection black Pg 9 R9000355 Cable socket suitable for K4-3m 4-pin, M x with moulded-on PUR cable, 3 m long. Cable cross-section: 4 x 0.34 mm, cable Ø approx. 5 mm black Pg 9 R90006438 Wire marking: : brown : white 3: blue 4: black Cable socket suitable for K4 4-pin, M x with threaded connection, angled. Housing can be rotated around 4 x 90 in relation to contact insert. black Pg 9 R90008899 Technical data (for applications outside these parameters, please consult us!) Ambient temperature C 40 to + 85 Type of protection according to VDE 0470 Nominal voltage according to VDE 00 group C V 50 V DC Nominal current per contact A 3 Clamping range for cables having an outer diameter of mm 6, up to 8 Maximum wire cross-section mm 0.75 Type of connection Cable cross-section mm 6 to 8 Unit dimensions (in mm) Cable socket suitable for K4 4-pin, M x with threaded connection 4,5 54 Cable socket suitable for K4-3m 4-pin, M x with moulded-on PVC cable, 3 m long M x Ø9,6 M x Ø9,6 IP 67 with cable socket mounted and locked Threaded connection Cable socket suitable for K4 4-pin, M x with threaded connection, angled 40 35 M x Ø9,6

4/4 Bosch Rexroth AG Industrial Hydraulics Cable sockets RE 08006/0.05 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Notes Bosch Rexroth AG Industrial Hydraulics Zum Eisengießer 9786 Lohr am Main, Germany Phone +49 (0) 93 5 / 8-0 Fax +49 (0) 93 5 / 8-3 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth AG. Without their consent it may not be reproduced or given to third parties. The data specifi ed above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The given information does not release the user from the obligation of own judgement and verifi cation. It must be remembered that our products are subject to a natural process of wear and aging.

RE 08006/0.05 Cable sockets Industrial Hydraulics Bosch Rexroth AG 5/4 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Notes Bosch Rexroth AG Industrial Hydraulics Zum Eisengießer 9786 Lohr am Main, Germany Phone +49 (0) 93 5 / 8-0 Fax +49 (0) 93 5 / 8-3 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth AG. Without their consent it may not be reproduced or given to third parties. The data specifi ed above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The given information does not release the user from the obligation of own judgement and verifi cation. It must be remembered that our products are subject to a natural process of wear and aging.

6/4 Bosch Rexroth AG Industrial Hydraulics Cable sockets RE 08006/0.05 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Notes Bosch Rexroth AG Industrial Hydraulics Zum Eisengießer 9786 Lohr am Main, Germany Phone +49 (0) 93 5 / 8-0 Fax +49 (0) 93 5 / 8-3 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifi cations and other information set forth in it, are the exclusive property of Bosch Rexroth AG. Without their consent it may not be reproduced or given to third parties. The data specifi ed above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The given information does not release the user from the obligation of own judgement and verifi cation. It must be remembered that our products are subject to a natural process of wear and aging.