FCC 47 CFR PART 15 SUBPART B

Similar documents
FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

Electromagnetic Compatibility Test Report Test results of Floww equipment

Declaration of Conformity.

Declaration of Conformity.

EMC TEST REPORT For. Webcam. Model Number: CAM67U

Declaration of Conformity.

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

Test Report #: Date: April 8, 2005

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Declaration of Conformity.

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Declaration of Conformity.

RAPPORTO DI PROVA / TEST REPORT

Declaration of Conformity.

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC File reference No:

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

TEST REPORT EN (1997) +A1 (2001)

Design and Certification of ASH Radio Systems for Japan

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

RX-AM4SF Receiver. Pin-out. Connections

Correlation between OATS, Fully Anechoic Room and GTEM Radiated Emissions

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Radio Frequency Exposure Test Report

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

Radiated emission measurement of a cell phone processor module using TEM cell

Digital Active Indoor Antenna SRT ANT 10 ECO

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

DVT913 TV CHANNEL CONVERTER

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Telephone- and leased line modem for industrial applications TD-36

Coupling/Decoupling Networks (CDN)

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

For the following information

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

Partial GSM TEST - REPORT

Electromagnetic Compatibility and International Regulatory Approvals

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

AN3353 Application note

FIBRE-OPTICS POWER METER INSTRUCTION MANUAL

Uncertainty evaluations in EMC measurements

EMI TEST REPORT. Product Name. Notebook Personal Computer. Model A770;A790. Applied by:

iva Cable & Antenna Analyzer

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

iva Cable & Antenna Analyzer

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Agilent E5100A Network Analyzer

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

CE Test Report. : Microchip Technology Inc West Chandler Blvd., Chandler, Arizona , USA

Waveguide Access Point WGA631. Product Guide

FCC Part 15C Compliance Test Report

30 In Compliance October

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Broadband Telecommunications Drop Amplifier

Regulatory requirements - USA

CE Test Report. : BL600 Series Bluetooth Low Energy Module

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

Nardalert S3 Non-Ionizing Radiation Monitor

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Low-cost EMI Pre-compliance Testing Using a Spectrum Analyzer

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

AM Radio Field Strength Measurements with Confidence November 2004

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Coupling- / Decoupling Network. 150 khz 300 MHz. 150 khz 230 MHz. 10 khz 230 MHz. IEC and CISPR 15 / CISPR 22 IEC

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Impedance 50 (75 connectors via adapters)

NI USB-5681 RF Power Meter Specifications

USB Plus+ RFID Reader Setup Guide

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Current Probes. User Manual

Agilent P940xA/C Solid State PIN Diode Switches

Physical Specifications (Custom design available.)

HP 70950B OPTICAL SPECTRUM ANALYZER

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

Transcription:

FCC 47 CFR PART 15 SUBPART B TEST REPORT For DC TO DC CONVERTER Model : E100/E100I Series Issued for MicroPower Direct, LLC 232 Tosca Drive Stoughton, MA 02072 U.S.A. Issued by Compliance Certification Services Inc. Tainan Lab. No. 8, Jiu Cheng Ling, Jiaokeng Village,Sinhua Township, Tainan Hsien 712, Taiwan R.O.C. TEL: 886-6-580-2201 FAX: 886-6-580-2202 Note: This report shall not be reproduced except in full, without the written approval of Compliance Certification Services Inc. Ltd. This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. Page 1 Total Page: 19

TABLE OF CONTENTS 1 TEST RESULT CERTIFICATION...3 2 EUT DESCRIPTION...4 3 TEST METHODOLOGY...6 3.1 EUT SYSTEM OPERATION...6 3.2 DECISION OF FINAL TEST MODE...6 4 SETUP OF EQUIPMENT UNDER TEST...7 5 FACILITIES AND ACCREDITATIONS...8 5.1 FACILITIES...8 5.2 LABORATORY ACCREDITATIONS AND LISTINGS...9 6 INSTRUMENT AND CALIBRATION...10 6.1 MEASURING INSTRUMENT CALIBRATION...10 6.2 TEST AND MEASUREMENT EQUIPMENT...10 7 LINE CONDUCTED & RADIATED EMISSION TEST...11 7.1 LIMIT...11 7.2 TEST PROCEDURE OF LINE CONDUCTED EMISSION...12 7.3 TEST PROCEDURE OF RADIATED EMISSION...13 7.4 TEST RESULTS...14 APPENDIX 1 - PHOTOGRAPHS OF TEST SETUP...19 Page 2

1 TEST RESULT CERTIFICATION Applicant: Equipment Under Test: Model: MicroPower Direct, LLC 232 Tosca Drive Stoughton, MA02072 U.S.A. DC TO DC CONVERTER E100/E100I Series Detailed EUT Description: See Item 2 of this report Date of Test: December 20 ~ December 21, 2005 Applicable Standard Class / Limit Test Result FCC 47 CFR Part 15 Subpart B IC ICES-003 ANSI C63.4 (2003) Class B Deviation from Applicable Standard None No non-compliance noted The above equipment was tested by Compliance Certification Services Inc. for compliance with the requirements set forth in the FCC Rules and Regulations Part 15, Subpart B, the measurement procedures were according to ANSI C63.4. This said equipment in the configuration described in this report shows the maximum emission levels emanating from equipment are within the compliance requirements. Approved by: Reviewed by: May 30, 2006 May 30, 2006 Alex Chiu Jeter Wu Manager Section Manager Compliance Certification Services Inc. Compliance Certification Services Inc. Page 3

2 EUT DESCRIPTION Product Model Housing Type Power Source DC TO DC CONVERTER E100/E100I Series Plastics E131 Input : DC 48V, 28mA, 13.44W Output : DC 5V, 200mA, 1W E104I Input : DC 5V, 257mA, 1.285W Output : DC 15V, 67mA, 1W Note: Client consigns only one model sample to test (Model Number: E100/E100I Series), Therefore, the testing Lab. just guarantees the units, which has been tested. E100/E100I Series Model Number Input Rating Output Rating % Load voltage current voltage current efficiency C.R. Page 4

Model Number Input Rating Output Rating % Load voltage current voltage current efficiency C.R. Page 5

3 TEST METHODOLOGY 3.1 EUT SYSTEM OPERATION 1. Setup whole system for test as shown on setup diagram. 2. Confirm output voltage. 3. Start test. Note: Test program is self-repeating throughout the test. 3.2 DECISION OF FINAL TEST MODE After the preliminary scan, the following test mode was found to produce the highest emission level. Mode 1: Normal Operation FOR Test Model : E131; E104I Then, the EUT configuration and cable configuration of the above highest emission mode was chosen for all final test items. Page 6

4 SETUP OF EQUIPMENT UNDER TEST Setup Diagram See test photographs attached in Appendix 1 for the actual connections between EUT and support equipment. Support Equipment No. Product Manufacturer Model No. Certify No. Signal cable 1 DC Power Supply LOKO DPS-5050 DOC N/A 2 LOAD N/A 25, 10W N/A N/A 3 LOAD N/A 223.8, 10W N/A N/A DC Power Supply (A) (A) + - EUT LOAD No. Signal cable description A Power Cable Unshielded, 1.2m, 2 pcs Note: All the above equipment/cables were placed in worse case positions to maximize emission signals during emission test. Grounding: Grounding was in accordance with the manufacturer s requirements and conditions for the intended use.. Page 7

5 FACILITIES AND ACCREDITATIONS 5.1 FACILITIES All measurement facilities used to collect the measurement data are located at CCS Tainan Lab. No. 8, Jiu Cheng Ling, Jiaokeng Village,Sinhua Township, Tainan Hsien 712, Taiwan R.O.C. The measurement facilities are constructed in conformance with the requirements of CISPR 16-1, ANSI C63.4 and other equivalent standards. Page 8

5.2 LABORATORY ACCREDITATIONS AND LISTINGS The test facilities used to perform Electromagnetic compatibility tests are registered or accredited by the organizations listed in the following table which includes the recognized scope specifically. Country Agency Scope of Accreditation Logo USA NVLAP EN 55014-1, AS/NZS 1044, CNS 13783-1, IEC/CISPR 14-1, IEC/CISPR 22, EN 55022, EN 61000-3-2, EN 61000-3-3, ANSI C63.4, AS/NZS CISPR 22, AS/NZS 3548, IEC 61000-4-2/3/4/5/6/8/11 200627-0 USA FCC 3/10 meter Open Area Test Sites to perform FCC Part 15/18 measurements 228014 Japan Taiwan VCCI CNLA 3/10 meter Open Area Test Sites and conducted test sites to perform radiated/conducted measurements CISPR 11 FCC METHOD-47 CFR Part 18 EN 55011 CNS 13803, CISPR 14 EN 55014 CNS 13783-1, CISPR 22 EN 55022 VCCI FCC Method-47 CFR Part 15 Subpart B CNS 13438 R-1989, C-2142 Taiwan BSMI CNS 13438, CNS 13783-1, CNS 13803 SL2-IS-E-0039 SL2-IN-E-0039 SL2-A1-E-0039 Canada Industry Canada RSS212, Issue 1 IC 6192 * No part of this report may be used to claim or imply product endorsement by NVLAP or any agency of the US Government. Page 9

6 INSTRUMENT AND CALIBRATION 6.1 MEASURING INSTRUMENT CALIBRATION The measuring equipment utilized to perform the tests documented in this report has been calibrated once a year or in accordance with the manufacturer's recommendations, and is traceable under the IEC 17025 to international or national standards. Equipment has been calibrated by accredited calibration laboratories. 6.2 TEST AND MEASUREMENT EQUIPMENT The following list contains measurement equipment used for testing. The equipment conforms to the requirement of CISPR 16-1, ANSI C63.2 and other equivalent standards. Calibration of all test and measurement, including any accessories that may effect such calibration, is checked frequently to ensure the accuracy. Adjustments are made and correction factors are applied in accordance with the instructions contained in the respective manual. Equipment Used for Emission Measurement Conducted Emission Test Name of Equipment Manufacturer Model Serial Number Date of Calibration OCT.21, 2005 8121-446 NNLK For Insertion loss L.I.S.N. SCHWARZBECK 8121 OCT. 04, 2005 8121-308 For Insertion loss Test Receiver R&S ESCS 30 100348 JUN. 17, 2005 N Type coaxial cable --------------- -------- ----------- N.C.R. Note: The measurement uncertainty is less than +/- 2.83dB, which is evaluated as per the NAMAS NIS 81 and CISPR/A/291/CDV. Open Area Test Site # 5 Name of Equipment Manufacturer Model Serial Number Date of Calibration O.A.T.S --------------- ---------- No.5 SEP. 12, 2005 TEST RECEIVER R&S ESCS 30 100294 JAN. 09, 2006 Pre-Amplifier HP 8447F 2944A03817 MAR. 09, 2006 SPECTRUM ANALYZER HP 8595E 3308A00344 MAR. 08, 2006 TYPE N COAXIAL CABLE --------------- CHA9513 004 SEP. 12, 2005 CHASE BILOG ANTENNA --------------- CBL6112B 2341 FEB. 16, 2006 Note: The measurement uncertainty is less than +/- 3.36dB, which is evaluated as per the NAMAS NIS 81 and CISPR/A/291/CDV. Page 10

7 LINE CONDUCTED & RADIATED EMISSION TEST 7.1 LIMIT Maximum permissible level of Line Conducted Emission Frequency Class A (dbuv) Class B (dbuv) (MHZ) Quasi-peak Average Quasi-peak Average 0.15-0.5 79 66 66-56 56-46 0.50-5.0 73 60 56 46 5.0-30.0 73 60 60 50 Note: The lower limit shall apply at the transition frequency. Maximum permissible level of Radiated Emission measured at 10 meter Frequency Class A (dbuv/m) Class B (dbuv/m) (MHZ) Quasi-peak Quasi-peak 30 230 40 30 230-1000 47 37 Note: The lower limit shall apply at the transition frequency. Maximum permissible level of Radiated Emission measured at 3 meter Frequency Class A (dbuv/m) Class B (dbuv/m) (MHZ) Average Peak Average Peak Above 1000 59.3 79.3 53.9 73.9 Note: The lower limit shall apply at the transition frequency. Page 11

7.2 TEST PROCEDURE OF LINE CONDUCTED EMISSION Procedure of Preliminary Test The EUT was set up as per the test configuration to simulate typical usage per the user s manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is placed on the ground plane as per ANSI C63.4 (see Test Facility for the dimensions of the ground plane used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane. Support equipment, if needed, was placed as per ANSI C63.4. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4. The test equipment EUT installed received AC power, 120VAC/60Hz, through a Line Impedance Stabilization Network (LISN), which supplied power source and was grounded to the ground plane. All support equipment received power from a second LISN. The EUT test program was started. Emissions were measured on each current carrying line of the EUT using a EMI Test Receiver connected to the LISN powering the EUT. The LISN has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1 connected to the Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1 connected to a 50 ohm load and Line 2 connected to the Receiver. The Receiver scanned from 150kHz to 30MHz for emissions in each of the test modes. During the above scans, the emissions were maximized by cable manipulation. The test mode(s) described in Item 3.2 were scanned during the preliminary test. After the preliminary scan, we found the test mode described in Item 3.2 producing the highest emission level. The EUT configuration and cable configuration of the above highest emission level were recorded for reference of the final test. Procedure of Final Test EUT and support equipment were set up on the test bench as per step 10 of the preliminary test. A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions. Emission frequency and amplitude were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit. If EUT emission level was less 2dB to the AV. limit in Q.P. mode, then the emission signal was re-checked using an AV. detector. The test data of the worst-case condition(s) was recorded. Calculation Formula REMARKS 1. Level (dbuv) = Read Level (dbuv) + LISN Factor (db) + Cable Loss (db) 2. Over Limit value (db) = Level (dbuv) Limit Line (dbuv) Page 12

7.3 TEST PROCEDURE OF RADIATED EMISSION Procedure of Preliminary Test The equipment was set up as per the test configuration to simulate typical usage per the user s manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters is used which is placed on the ground plane. When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane. Support equipment, if needed, was placed as per ANSI C63.4. All I/O cables were positioned to simulate typical usage as per ANSI C63.4. The EUT received AC power source, 120VAC/60Hz, from the outlet socket under the turntable. All support equipment received power from another socket under the turntable. The antenna was placed at 10 meter away from the EUT as stated in ANSI C63.4. The antenna connected to the Spectrum Analyzer via a cable and at times a pre-amplifier would be used. The Analyzer / Receiver quickly scanned from 30MHz to 40GHz maximum, if any. The EUT test program was started. Emissions were scanned and measured rotating the EUT to 360 degrees and positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the emission reading level. The test mode(s) described in Item 3.2 were scanned during the preliminary test: After the preliminary scan, we found the test mode described in Item 3.2 producing the highest emission level. The EUT and cable configuration, antenna position, polarization and turntable position of the above highest emission level were recorded for the final test. Procedure of Final Test EUT and support equipment were set up on the turntable as per step 8 of the preliminary test. The Analyzer / Receiver scanned from 30MHz to 40GHz maximum, if any. Emissions were scanned and measured rotating the EUT to 360 degrees, varying cable placement and positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the emission reading level. Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position, polarization and turntable position were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit and only Q.P. reading is presented. The test data of the worst case condition(s) was recorded. Calculation Formula REMARKS 1.Level (dbuv/m) = Read Level (dbuv) + Antenna Factor (db/m) + Cable loss (db) 2.Over Limit value (db) = Level (dbuv/m)-limit Line(dBuV/m) Page 13

7.4 TEST RESULTS Line Conducted Emission **Note: Sine this EUT is powered by DC Source, this test item is not applicable. Common Mode Conducted Emission Not applicable Page 14

Radiated Emission Model: E131 Temperature: 30 C Detector Function: Quasi-peak. Tested by: Eric Yang Test Mode: Normal Operation Humidity: 56 % RH Antenna: Horizontal at 10m Test Results: Pass HORIZONTAL REMARKS 1.Level (dbuv/m) = Read Level (dbuv) + Antenna Factor (db/m) + Cable loss (db) 2.Over Limit value (db) = Level (dbuv/m)-limit Line(dBuV/m) Page 15

Model: E131 Temperature: 30 C Detector Function: Quasi-peak. Tested by: Eric Yang Test Mode: Normal Operation Humidity: 56 % RH Antenna: Vertical at 10m Test Results: Pass VERTICAL REMARKS 1.Level (dbuv/m) = Read Level (dbuv) + Antenna Factor (db/m) + Cable loss (db) 2.Over Limit value (db) = Level (dbuv/m)-limit Line(dBuV/m) Page 16

Model: E104I Temperature: 30 C Detector Function: Quasi-peak. Tested by: Eric Yang Test Mode: Normal Operation Humidity: 56 % RH Antenna: Horizontal at 10m Test Results: Pass HORIZONTAL REMARKS 1.Level (dbuv/m) = Read Level (dbuv) + Antenna Factor (db/m) + Cable loss (db) 2.Over Limit value (db) = Level (dbuv/m)-limit Line(dBuV/m) Page 17

Model: E104I Temperature: 30 C Detector Function: Quasi-peak. Tested by: Eric Yang Test Mode: Normal Operation Humidity: 56 % RH Antenna: Vertical at 10m Test Results: Pass VERTICAL REMARKS 1.Level (dbuv/m) = Read Level (dbuv) + Antenna Factor (db/m) + Cable loss (db) 2.Over Limit value (db) = Level (dbuv/m)-limit Line(dBuV/m) Page 18

APPENDIX 1 - PHOTOGRAPHS OF TEST SETUP RADIATED EMISSION TEST END OF REPORT Page 19