Regulation and shut-off damper SPBA and SPCA

Similar documents
CONTROL/SLAVE Zone. Zone damper for Swegon s WISE System for demand-controlled ventilation

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

TFSR & TFSK Roof Fans

3/2-way Solenoid Valve, direct-acting, NC or NO

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Electric Rotary Actuator - On/Off or programmable control actuator

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Butterfly Valves PN 6/10/16 for flanged connection

High-speed spiral doors for deep-freeze applications. TK Series

The compact unit series

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

kymanual or Automatic - it s your Choice

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

POWERS Controls No. 4 Pneumatic Damper Actuator

MODEL HSR-007 Direct Drive Rolling Steel

AMD-33 Air Measuring Station with VCD-33 Control Damper

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB EDITION 5.

Rotary actuators Rotary wing drives Series RAK. Brochure

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Series 8146/5-V37 and Series 8150/5-V37

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

System 8. ü ( System 8

SERVER ROOM CABINET INSTALLATION CONCEPTS

How To Make A Supply Air Ceiling

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja 12 14tel: Hinges

FIRE DAMPER APPLICATION GUIDE

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

How To Drive A Compact Serie 1

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

CRN A-F-G-E-HQQE 3x400D 50 HZ

1.1 Z 011-A WAFER PATTERN BUTTERFLY TYP Z 011-A TECHNICAL DATA

Air Comfort. Technical Catalogue > Roof Fan STOF

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

ICQ Series - square centrifugal

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

Series 6000 Torque measured metal bellow coupling

Type: DILM32 10(24V50HZ) Article No.:

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

STAR Linear Bushings and Shafts Supplement RE / Linear Motion and Assembly Technologies

Dampers. Inlet guide vane. Damper. Louvre damper. Handbook Radial Fans / Chapter 3 - Dampers REITZ List 2010 DO 1. Dampers

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

Hydraulic Control Solutions

Transformer oil cooler ALFA A02

CADB and CADT-D / DI / DC Series

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Guide rail bracket (for adjustable heads)

Assisted lift operated 2/2-way solenoid valves Type EV250B

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Series description: Wilo-Drain TC 40

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Type: DILM9 10(24VDC) Article No.:

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

SMOKE DAMPERS IMOS DKI-1 TECHNICAL CONDITIONS TPI (DAMPERS FOR EMISSION EXHAUST) FOR ONE FIRE AREA

Energy Saving ECM Motors and Fans Ventilation Catalogue

AC axial fans A series

HDA

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

Air damper actuators

PLQE. The base of the economy gearboxes with square output flange. Economy Line. Formerly PLE

RUBBER SLEEVE KNIFE GATE VALVE

Hydraulically actuated clutches and spring-applied brakes clutch/brake combined units

High-speed folding doors. F Series


RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Tyco PremiAir Pneumatic Actuators

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Type: DILM50(230V50HZ,240V60HZ) Article No.:

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Vacuum Gate Valve DN 100 and DN 150

UDSA - UDSBD unit heater

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

Free piston Stirling engine for rural development

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

Architectural Specifications MODEL HDXL Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8

EC DECLARATION OF CONFORMITY FOR MACHINES

Transcription:

Regulation and shut-off damper SPBA and SPCA Multi leaf dampers are used as regulation, shut-off and mixing dampers in air handling systems and units. Dampers are mounted to air handling units and rectangular ducts by means of a slip joint or a flange joint, and to circular ducts with sealed spigots. They are equipped with a base for actuator and an external position indicator. With the face area larger than 5 m², the damper is put together of two or more units with each having its own actuator. Specifications Leakage classes CEN1, CEN3 and CEN4 Non insulated, blades insulated and casing insulated Robust construction Split, flange and circular joint Base for actuator as default Large range of actuators Made of galvanized steel sheet or acid-proof steel Body width 120 mm / 220 mm Product code example Shut off damper SPBA-3L01400180000 Damper with tightness class CEN 3, blades thermally insulated, nominal size 1400x1800, slip joint, galvanized steel 1 (10) Specifications are subject of alteration without further notice.

Properties SPBA SPBA-1... regulation damper for balancing air flows no thermal insulation leakage class: 1 (CEN) leakage class of casing: B SPBA-3... regulation and shut-off damper to be used where low leakage is required no thermal insulation SPBA-3L... effective thermal insulation are required blades thermally insulated heat transmission Um = 4 W/m 2 K General information SPBA Construction Multi leaf damper is available with slip or flange joint. The width of the SPBA body is 220 mm. The blades are profiled and mechanically jointed and they are linked with a lever mechanism to achieve opposite actions. The drive shaft is the third shaft from the bottom; in two-blade dampers the upper shaft is the driving one. The dampers are equipped with a base for actuator and an external position indicator. The normal operating temperature of the dampers with standard construction varies between -40 C and +80 C. The multi leaf damper is also available with a protective cover for the lever mechanism. The protective cover is attached to the damper with screws, so that it can easily be detached e.g. for installation. The protective cover also serves as base for motor. SPBA-3LE... effective thermal insulation are required also through casing blades and casing thermally insulated heat transmission Um = 4 W/m 2 K SPBA-4L... effective thermal insulation are of great importance blades thermally insulated leakage class: 4 (CEN) heat transmission Um = 4 W/m 2 K SPBA-4LE... effective thermal insulation are of great importance blades and casing thermally insulated leakage class: 4 (CEN) heat transmission U m = 4 W/m 2 K Installation The multi leaf dampers are mounted to air handling units and rectangular ducts by means of a slip joint or a flange joint, and to circular ducts with sealed spigots. If the face area is larger than 5 m², the damper is put together of two or more units with each having its own actuator. Material The casing and blades of a multi leaf damper are made of hot-galvanized steel sheet or acid-proof steel. The bearings and edges of the blades are made of polyamide, the seals are profiled PVC and EPDM. The material used for thermal insulation is mineral wool. 2 (10) Specifications are subject of alteration without further notice.

Dimensions SPBA Width B 200-2500 mm Height H 200-2600 mm B x H max 5 m² Circular joints NOTE! Insulated casing increases the dimensions: B+160, H+60 If the face area is larger than 5 m², the damper is put together of two or more units. Construction and dimensions are agreed on separately. Slip joint 1) Base for actuator ØD B x H A (mm) 160 200 250 315 400 500 630 800 1000 1250 200 x 200 200 x 200 300 x 300 400 x 400 400 x 400 500 x 500 650 x 650 800 x 800 1000 x 1000 1300 x 1300 35 35 45 45 85 70 80 140 140 140 1) Base for actuator Flange joint 1) Base for actuator C = 120 mm when H = 200, 400, etc. C = 170 mm when H = 300, 500, etc. Dampers with flange joints are equipped with Ø5 mm screw holes with 200 mm spacing to enable the mounting e.g. to wall surface without a counter-flange. 3 (10) Specifications are subject of alteration without further notice.

Technical data SPBA Max allowable pressure difference Sound power level Lw in duct when damper closed (SPBA-300, SPBA-3L0, SPBA-3LE) L W (A = 1 m²) (db) p Medium frequence of octave band (Hz) (Pa) 63 125 250 500 1000 2000 4000 8000 500 43 38 43 47 50 53 62 69 1000 43 41 48 52 56 60 67 70 In duct Damper weight 5 4 3 2 Face area (m 2 ) 1 0,5 0,4 0,3 0,2 Duct end, extract 0,1 0,05 4 5 6 10 20 30 40 50 70 120 Weight (kg) Sound power level Lw CORRECTION K oct (db) SPBA Medium frequence of octave band (Hz) 63 125 250 500 1000 2000 4000 8000 9 4 1 2-1 -3-8 -12 Tol.± 5 5 5 4 4 4 4 4 CORRECTION K A (db) Face area of damper (m²) 0.1 0.15 0.25 0.4 0.6 1.0 1.6 2.5 4.0-10 -8-6 -4-2 0 2 4 6 The sound power levels of the duct for every octave band are obtained by adding the corrections K oct of octave bands and K A of the face area (see tables above) to the total sound pressure level L p10a, db(a), according to the following formula: L Woct = L p10a + K oct + K A Correction K oct is the average in the area of application of SPBA. 4 (10) Specifications are subject of alteration without further notice.

Duct end, supply torque SPBA The torque used depends e.g. on the type, width and length of the multi leaf damper, the total length of the sealing surfaces and the mounting method. The actuator torque required for the shut-off function of SPBA-3... and SPBA-4... and the recommended actuator type are shown in the tables below. 1: 10 Nm actuator 2: 20 Nm actuator 3: 30 Nm actuator 5 (10) Specifications are subject of alteration without further notice.

Properties SPCA SPCA-3... regulation and shut-off damper to be used where low leakage is required no thermal insulation SPCA-3L... effective thermal insulation are required blades thermally insulated heat transmission Um = 4.5 W/m 2 K SPCA-3LE... effective thermal insulation are required also through casing blades and casing thermally insulated heat transmission Um = 4.5 W/m 2 K SPCA-4... shut-off damper to be used where low leakage is required no thermal insulation leakage class: 4 (CEN) SPCA-4L... effective thermal insulation are of great importance blades thermally insulated leakage class: 4 (CEN) heat transmission Um = 4.5 W/m 2 K General information SPCA Construction Multi leaf damper is available with slip or flange joint. The width of the SPCA body is 120 mm with a slip joint and 130 mm with a flange joint. The blades are profiled and mechanically jointed to achieve high strength and they are linked with a lever mechanism to achieve opposite actions. The top shaft is the drive shaft. The dampers are equipped with a screw-on cover plate that protects and supports the total length of the gear unit. the base for actuator is installed on the cover plate. NOTE! Dampers are never delivered without the protective cover. The normal operating temperature varies between -40 C and +80 C. Installation The dampers are mounted to air handling units and rectangular ducts by means of a slip joint or a flange joint. Material The casing and blades of a multi leaf damper are made of hot-galvanized steel sheet or acid-proof steel. The bearings and edges of the blades are made of polyamide, the seals are profiled PVC and EPDM. The material used for thermal insulation is mineral wool. SPCA-4LE... effective thermal insulation are of great importance blades and casing thermally insulated leakage class: 4 (CEN) heat transmission Um = 4.5 W/m 2 K 6 (10) Specifications are subject of alteration without further notice.

Dimensions SPCA Width B Height H 200-1400 mm 200-1000 mm NOTE! Insulated casing increases the dimensions: B+120, H+60 Slip joint Technical data SPCA Sound power level Lw CORRECTION K oct (db) SPCA Medium frequence of octave band (Hz) 63 125 250 500 1000 2000 4000 8000 6 5 3 1 0-4 -8-15 Tol.± 5 5 5 4 4 4 4 4 CORRECTION K A (db) Face area of damper (m²) 0.04 0.06 0.1 0.15 0.25 0.4 0.65 1.0 1.6-10 -8-6 -4-2 0 2 4 6 The sound power levels of the duct for every octave band are obtained by adding the corrections K oct of octave bands and K A of the face area (see tables above) to the total sound pressure level L p10a, db(a), according to the following formula: 1) Axel support Flange joint L Woct = L p10a + K oct + K A Correction K oct is the average in the area of application of SPCA. Sound power level Lw in duct when damper closed L W (A = 1 m²) (db) p Medium frequence of octave band (Hz) (Pa) 63 125 250 500 1000 2000 4000 8000 500 34 37 41 49 54 56 59 54 1000 43 41 45 53 59 62 65 64 In duct C = 120 mm when H = 200, 400, etc. C = 170 mm when H = 300, 500, etc. 7 (10) Specifications are subject of alteration without further notice.

Duct end, extract torque SPCA The torque used depends e.g. on the type, width and length of the multi leaf damper, the total length of the sealing surfaces and the mounting method. The actuator torque required for the shut-off function of SPCA and the recommended actuator type are shown in the table below. Duct end, supply 1: 10 Nm actuator 2: 20 Nm actuator 8 (10) Specifications are subject of alteration without further notice.

Product code SPBA Multi leaf damper SPBA-abcddddeeeefg Product code SPCA Multi leaf damper SPCA-abcddddeeeefg Tightness class (a) 1 = CEN 1 (b = 0, c = 0) 3 = CEN 3 4 = CEN 4 (b = L) Blade insulation (b) 0 = none L = insulated blade (a = 3 or 4) Casing insulation (c) 0 = none E = insulated casing (a = 3 or 4, b = L) Damper width or duct diameter (dddd) Width 200-1000 mm in steps of 50 mm Width 1100-2500 mm in steps of 100 mm Duct diameter 0160, 0200, 0250, 0315, 0400, 0500, 0630, 0800, 1000, 1250 (eeee = 0000, f = 2 or 3) Damper height (eeee) Height 200-1000 mm in steps of 50 mm Height 1100-2600 mm in steps of 100 mm 0000 = duct diameter (f = 2 or 3) Joint type (f) 0 = slip joint 1 = flange joint 2 = circular duct connection on one side + slip joint on other side 3 = circular duct connection on both sides Material (g) 0 = galvanized steel 1 = acid-proof stainless steel 316L Examples SPBA-3L01400180000 Damper with tightness class CEN 3, blades thermally insulated, nominal size 1400x1800, slip joint, galvanized steel SPBA-1000800150011 Damper with tightness class CEN 1, nominal size 800x1500, flange joint, acid-proof steel Tightness class (a) 3 = CEN 3 4 = CEN 4 Blade insulation (b) 0 = none L = insulated blade (a = 3 or 4) Casing insulation (c) 0 = none E = insulated casing (a = 3 or 4, b = L) Damper width or duct diameter (dddd) Width 200-1000 mm in steps of 50 mm Width 1100-1400 mm in steps of 100 mm Duct diameter 0160, 0200, 0250, 0315, 0400, 0500, 0630, 0800, 1000, 1250 (eeee = 0000, f = 2 or 3) Damper height (eeee) Height 200-1000 mm in steps of 100 mm 0000 = duct diameter (f = 2 or 3) Joint type (f) 0 = slip joint 1 = flange joint 2 = circular duct connection on one side + slip joint on other side 3 = circular duct connection on both sides Material (g) 0 = galvanized steel 1 = acid-proof stainless steel 316L Examples SPCA-3L00400080000 Damper with tightness class CEN 3, blades thermally insulated, nominal size 0400x0800, slip joint, galvanized steel NOTE! SPCA dampers are always delivered with protective cover for gear unit. Base for actuator is mounted on protective cover. 9 (10) Specifications are subject of alteration without further notice.

Accessories Manual regulator standard with CEN 1 model (SPBA-1...) Regulator with extension length 1500 mm Protective cover for level mechanism Material (aa) 00 = galvanized 01 = acid-proof SPBZ-01-aa SPBZ-02-aa SPBZ-03-aa SPBZ-04-aa 00 = On-off 24 V, 5 Nm without spring-return 01 = On-off 24 V, 10 Nm without spring-return 02 = On-off 24 V, 20 Nm without spring-return 03 = On-off 24 V, 40 Nm without spring-return SPBZ-05-aa 00 = On-off 24 V auxiliary switch, 5 Nm without springreturn 01 = On-off 24 V auxiliary switch, 10 Nm without springreturn 02 = On-off 24 V auxiliary switch, 20 Nm without springreturn SPBZ-06-aa 00 = On-off 230 V, 5 Nm without spring-return 01 = On-off 230 V, 10 Nm without spring-return 02 = On-off 230 V, 20 Nm without spring-return 03 = On-off 230 V, 40 Nm without spring-return SPBZ-07-aa 00 = On-off 230 V auxiliary switch, 5 Nm without spring-return 01 = On-off 230 V auxiliary switch, 10 Nm without spring-return 02 = On-off 230 V auxiliary switch, 20 Nm without spring-return SPBZ-08-aa 00 = 24 V Control DC 2-10 V, 5 Nm without springreturn 01 = 24 V Control DC 2-10 V, 10 Nm without springreturn 02 = 24 V Control DC 2-10 V, 20 Nm without springreturn 03 = 24 V Control DC 2-10 V, 40 Nm without springreturn SPBZ-09-aa 00 = 230 V Control DC 2-10 V, 5 Nm without springreturn 01 = 230 V Control DC 2-10 V, 10 Nm without springreturn 02 = 230 V Control DC 2-10 V, 20 Nm without springreturn SPBZ-10-aa 00 = On-off 24 V, 4 Nm with spring-return 01 = On-off 24 V, 10 Nm with spring-return 02 = On-off 24 V, 20 Nm with spring-return 03 = On-off 24 V, 30 Nm with spring-return SPBZ-11-aa 00 = On-off 24 V auxiliary switch, 4 Nm with springreturn 01 = On-off 24 V auxiliary switch, 10 Nm with springreturn 02 = On-off 24 V auxiliary switch, 20 Nm with springreturn 03 = On-off 24 V auxiliary switch, 30 Nm with springreturn SPBZ-12-aa 00 = On-off 230 V, 4 Nm with spring-return 01 = On-off 230 V, 10 Nm with spring-return 02 = On-off 230 V, 20 Nm with spring-return 03 = On-off 230 V, 30 Nm with spring-return SPBZ-13-aa 00 = On-off 230 V auxiliary switch, 4 Nm with springreturn 01 = On-off 230 V auxiliary switch, 10 Nm with springreturn 02 = On-off 230 V auxiliary switch, 20 Nm with springreturn 03 = On-off 230 V auxiliary switch, 30 Nm with springreturn SPBZ-14-aa 00 = 24 V Control DC 2-10 V, 4 Nm with spring-return 01 = 24 V Control DC 2-10 V, 10 Nm with spring-return 02 = 24 V Control DC 2-10 V, 20 Nm with spring-return 03 = 24 V Control DC 2-10 V, 30 Nm with spring-return 10 (10) Specifications are subject of alteration without further notice.