Screw-type heat meter G20 / G21

Similar documents
SHARKY 775 COMPACT ENERGY METER ULTRASONIC

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

MOUNTING AND OPERATING INSTRUCTIONS

HYDRUS ULTRASONIC METER

How To Use A Corona Mdi 110

IFC 070 Technical Datasheet

AMTRON E-30 Compact heat and cooling meter

SONOMETER TM 1000 Ultrasonic compact heat meter

Series description: Wilo-Yonos MAXO-D

Heat meters Cooling meters

Series description: Wilo-Yonos MAXO

OZW30. Central Unit SYNERGYR

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Turbine Flow Sensor Series VTR

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Series description: Wilo-Star-Z

Fluxi 2000/TZ Turbine Gas Meter

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

The multi-functional integrator Supercal 531

Instructions for assembly and use MULTICAL 601

How To Use A Multi-Line Calculator With A Power Supply And Power Supply (Kamstrup)

Digital inductive conductivity transmitter

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Duct Humidity Transmitter

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Hand-held thermometer Model CTH7000

How To Use A Flowmeter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electric Rotary Actuator - On/Off or programmable control actuator

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Proportional pressure regulators VPPE

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Typical Aluminum GFM Mass Flow Meter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Butterfly Valves PN 6/10/16 for flanged connection

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

IN-OUT Thermometer with Cable Free Sensor and Clock

HERZ-Thermal Actuators

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

MULTICAL 21 DATA SHEET. Electronic ultrasonic cold and hot water meter

4-Channel Thermometer / Datalogger

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Overview of types. Technical data

Electromagnetic Flow Meter

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

SunMaxx Solar Filling Station Operating Instructions

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

FIELD TESTS OF FUEL EFFICIENCY MAGNETS J A CRABB JULY 1997 SWEEG REPORT 80

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Cable Plug acc. to DIN EN , Form A

Hydraulic Control Solutions

SHARKY 775 Ultrasonic Compact Energy Meter. Installation and User Guide

Portable digital microprocessor thermometers with interchangeable probes

Drayton Digistat +2RF/+3RF

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Operating Instructions for Plastic Flow Meter. Model: KSK

Series 7500 Torque Sensor

Stove Guard Kit User Manual

BB-18 Black Body High Vacuum System Technical Description

Heating, air-conditioning, cooling

Instruction Manual. T3111 T3111L T3111P T3111Ex

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Plastic tube flowmeters Series PT/PS

Electronic Pressure Switch EDS 300

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Type overview. Technical data

COMBIMASS. Technical Data COMBIMASS eco-bio +

Water Metering System SmartMeter Prepayment. SmartMeter Prepayment. Water Metering System

Material test chamber with mechanical convection

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

A project to optimise quality and energy efficiency must include metering

Wireless Indoor/ Outdoor Thermometer

Operating instructions for Electrode sharpening machine WIG 4

Vacuum drying oven for non-flammable solvents

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Solenoid Valve Island Type 3965

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

ECOplus Solar Cylinder

Voltage Regulator SPAU 341 C. Product Guide

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

User's Guide. Integrating Sound Level Datalogger. Model Introduction

PS1800 Centrifugal Pumping Systems

Series 6000 Torque measured metal bellow coupling

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Installation & User Instructions

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Transcription:

Screw-type heat meter G20/G21 Screw-type heat meter with optical interface for retrofitting to external modules. Thanks to integrated modules, the devices can be equipped with the required communication technology ex factory. For use in the Q opto and Q basic systems or through an integrated communication module in the Q M-Bus system. Can be retrofitted with external modules for use in the systems Q M-Bus, Q walk-by and Q AMR. As series G21 with combined heat and cold metering. 1/12 www.qundis.com Screw-type heat meter G20 / G21 DST1-QHEA-GB0 G2x

Application The heat meter is used for measuring heat energy. With model G21, the combined measurement of heat and cold energy is possible. The main areas of application are in central heating systems where the heating energy is outputted individually to different consumers. This is meaningful in: ~ ~ Apartment buildings ~ ~ Offices and administration buildings Typical users are: ~ ~ Metering service companies ~ ~ Housing associations ~ ~ Property management companies ~ ~ Specialist companies for sanitary, heating and air-conditioning technology Functions ~ ~ Heat meter G20 or combined heat/cold meter G21 for direct or indirect installation of the temperature sensors ~ ~ Optical interface for external communication modules ~ ~ Internal communication modules for M-Bus and impulse available ex factory ~ ~ Mains-independent, for local use, 6 or 10-year lithium battery ~ ~ PTB-approved, approval no. D 22.12/04.03 ~ ~ MID-approved, type approval certificate PTB DE-08-MI004-PTB013 ~ ~ Values are measured by two platinum PT 1000 resistance thermometers and one hydraulic impeller wheel sensor with patented magnet-free scanning according to the conductance principle with carbide-sapphire bearings for low-wear and reliable long-term measuring operation ~ ~ High resolution thanks to 7-digit LC display that indicates current value, old value, check number and many service and operating parameters ~ ~ Additional display of 18 monthly values with date ~ ~ Storage of the maximum supply flow and return flow temperatures as well as the maximum current flow with date ~ ~ Programming of a due date can be carried out on-site via the optical interface ~ ~ Add-on modules for radio or M-Bus communication as well as impulse output and RS 232 modules can be retrofitted at any time on-site via the optical interface ~ ~ Thanks to integrated modules, the devices can be equipped with the required communication technology (M-Bus or impulse output) ex factory 2/12

Type summary Part number G20 / G21 Heat meter Heat/cold meter 0.6 m³/h for immersion sleeve and direct measurement - temperature sensor 5.0 x 45 mm with 1.5 m temperature sensor cable G ¾ x 110 mm G20/0000-00 G21/0000-00 with 3.0 m temperature sensor cable G ¾ x 110 mm G20/0300-00 G21/0300-00 1.5 m³/h for immersion sleeve and direct measurement - temperature sensor 5.0 x 45 mm with 1.5 m temperature sensor cable G ¾ x 110 mm G20/0010-00 G21/0010-00 with 3.0 m temperature sensor cable G ¾ x 110 mm G20/0310-00 G21/0310-00 2.5 m³/h for immersion sleeve and direct measurement - temperature sensor 5.0 x 45 mm with 1.5 m temperature sensor cable G 1 x 130 mm G20/0020-00 G21/0020-00 with 3.0 m temperature sensor cable G 1 x 130 mm G20/0320-00 G21/0320-00 0.6 m³/h for direct measurement - temperature sensor acc. to AGFW with 1.5 m temperature sensor cable G ¾ x 110 mm G20/8000-00 G21/8000-00 with 3.0 m temperature sensor cable G ¾ x 110 mm G20/8300-00 G21/8300-00 1.5 m³/h for direct measurement - temperature sensor acc. to AGFW with 1.5 m temperature sensor cable G ¾ x 110 mm G20/8010-00 G21/8010-00 with 3.0 m temperature sensor cable G ¾ x 110 mm G20/8310-00 G21/8310-00 2.5 m³/h for direct measurement - temperature sensor acc. to AGFW with 1.5 m temperature sensor cable G 1 x 130 mm G20/8020-00 G21/8020-00 with 3.0 m temperature sensor cable G 1 x 130 mm G20/8320-00 G21/8320-00 G20 / G21 for external installation spots 0.6 m³/h for immersion sleeve measuring - temperature sensor 5.2 x 45 mm with 1.5 m temperature sensor cable G ¾ x 110 mm G20/1000-00 G21/1000-00 with 3.0 m temperature sensor cable G ¾ x 110 mm G20/1300-00 G21/1300-00 1.5 m³/h for immersion sleeve measuring - temperature sensor 5.2 x 45 mm with 1.5 m temperature sensor cable G ¾ x 110 mm G20/1010-00 G21/1010-00 with 3.0 m temperature sensor cable G ¾ x 110 mm G20/1310-00 G21/1310-00 2.5 m³/h for immersion sleeve measuring - temperature sensor 5.2 x 45 mm with 1.5 m temperature sensor cable G 1 x 130 mm G20/1020-00 G21/1020-00 with 3.0 m temperature sensor cable G 1 x 130 mm G20/1320-00 G21/1320-00 0.6 m³/h for immersion sleeve measuring - temperature sensor 6.0 x 50 mm with 1.5 m temperature sensor cable G ¾ x 110 mm G20/2000-00 G21/2000-00 with 3.0 m temperature sensor cable G ¾ x 110 mm G20/2300-00 G21/2300-00 1.5 m³/h for immersion sleeve measuring - temperature sensor 6.0 x 50 mm with 1.5 m temperature sensor cable G ¾ x 110 mm G20/2010-00 G21/2010-00 with 3.0 m temperature sensor cable G ¾ x 110 mm G20/2310-00 G21/2310-00 2.5 m³/h for immersion sleeve measuring - temperature sensor 6.0 x 50 mm with 1.5 m temperature sensor cable G 1 x 130 mm G20/2020-00 G21/2020-00 with 3.0 m temperature sensor cable G 1 x 130 mm G20/2320-00 G21/2320-00 3/12

Type summary G20 / G21 with internal module Heat meter Part number * Heat/cold meter Internal communication modules M-BUS module G20/xxx2-xxx G21/xxx2-xx Impulse output G20/xxx3-xxx G21/xxx3-xx * x = any option code Further order options Volume measurement in heat pipes Immersion sleeve and direct measurement, temperature sensor G20/Axxx-xxx G21/Axxx-xx 5.0 x 45 mm Immersion sleeve measurement, temperature sensor 5.2 x 45 mm G20/Bxxx-xxx G21/Bxxx-xx Immersion sleeve measurement, temperature sensor 6.0 x 50 mm G20/Cxxx-xxx G21/Cxxx-xx Direct measurement, temperature sensor acc. to AGFW G20/Kxxx-xxx G21/Kxxx-xx * x = any option code Further accessories Order data Programming key for due date programming Remote display with wall bracket, inc. plug-in cable 2.5 m long Extension cable 5 m long Part no. G99/PAFF-01 R99/FANZ-01 390 980 M-Bus cable with sealable plug, 2-pole for M-Bus, 3.0 m long * 593 812 Impulse cable with sealable plug, 2-pole, 3.0 m long for G20 * 4-pole, 3.0 m long for G21 * * only for devices with integrated modules 593 812 593 559 4/12

Installation material Direct temperature measurement Order data Part no. Direct measurement installation set R 1/2" with RL screwed connections for WMZ with q p 0.6 m³/h and 1.5 m³/h 592 977 Direct measurement installation set R 3/4" with RL screwed connections for WMZ with q p 0.6 m³/h and 1.5 m³/h 592 978 Direct measurement installation set R 1" with RL screwed connections for WMZ with q p 0.6 m³/h and 1.5 m³/h 592 979 Direct measurement installation set R 3/4" with RL screwed connections for WMZ with q p 2.5 m³/h 592 980 Direct measurement installation set R 1" with RL screwed connections for WMZ with q p 2,5 m³/h 592 981 Direct measurement installation set R 1/2" with RL ball valves for WMZ with q p 0.6 m³/h and 1.5 m³/h 592 982 Direct measurement installation set R 3/4" with RL ball valves for WMZ with q p 0.6 m³/h and 1.5 m³/h 593 983 Direct measurement installation set R 1" with RL ball valves for WMZ with q p 0.6 m³/h and 1.5 m³/h 592 984 Direct measurement installation set R 3/4" with RL ball valves for WMZ with q p 2.5 m³/h 592 985 Direct measurement installation set R 1" with RL ball valves for WMZ with q p 2.5 m³/h 592 986 Indirect temperature measurement Order data Part no. Immersion sleeve installation set R 1/2" with RL screwed connections for WMZ with q p 0.6 m³/h and 1.5 m³/h 531 236 Immersion sleeve installation set R 3/4" with RL screwed connections for WMZ with q p 0.6 m³/h and 1.5 m³/h 531 237 Immersion sleeve installation set R 1" with RL screwed connections for WMZ with q p 0.6 m³/h and 1.5 m³/h 531 238 Immersion sleeve installation set R 3/4" with RL screwed connections for WMZ with q p 2.5 m³/h 531 713 Immersion sleeve installation set R 1" with RL screwed connections for WMZ with q p 2.5 m³/h 531 971 Immersion sleeve installation set R 1/2" with RL ball valves for WMZ with q p 0.6 m³/h and 1.5 m³/h 531 957 Immersion sleeve installation set R 3/4" with RL ball valves for WMZ with q p 0.6 m³/h and 1.5 m³/h 590 365 Immersion sleeve installation set R 1" with RL ball valves for WMZ with q p 0.6 m³/h and 1.5 m³/h 590 367 Immersion sleeve installation set R 3/4" with RL ball valves for WMZ with q p 2.5 m³/h 590 369 Immersion sleeve installation set R 1" with RL ball valves for WMZ with q p 2.5 m³/h 531 959 Ordering The part numbers shown in the type summary must be quoted in orders. If a due date other than January 1 is required, the type description must be supplemented by the required month in the order (the due date is always the first of the month). Ordering example for a heat meter with 110 mm installation length and May 1 as due date: G20/0000-00, due date: May 5/12

Technology The heat meter G20 / G21 comprises a pair of precise temperature sensors and a volume meter which is installed in a hot water or cooling circuit. An electronic calculator unit continually calculates the difference in temperature between the supply and return flow and multiplies the value by the flow rate. The result of this (current heating or cooling capacity) is cumulated, displayed or forwarded to a data-processing system by radio or cable. The heat meter G20 / G21 is a heat meter that can be extended by different internal and external modules. Internal modules are integrated into the device during production in the factory. The G20 / G21 has two communication interfaces available. 1. The optical interface Q opto (1107) which is accessible from the outside. This allows programming and retrofitting work on the G20 / G21 on-site at all times. The heat meter can be retrofitted for radio or other communication means. The respective modules are simply mounted on the calculator unit. 2. The internal module interface for internal impulse output or M-Bus modules. In the case of integrated modules, the information is forwarded via a permanently mounted, threaded and sealed cable connection (impulse output and M-Bus). Measuring principle The hydraulic sensor (volume meter) is based on the single-jet impeller wheel sensor principle. The scanning of impeller wheel revolutions takes place using the electrical conductance of the water in the sensor. Several electrodes are arranged in the water in such a way that an electrical signal can be discharged as the impeller wheel rotates. Determining water consumption Using the measured difference in temperature between supply and return flow, the flow rate and the calculated thermal coefficient, the heat quantity is shown on the LC display in physical units (kwh, MWh, MJ, GJ) following an internal calculation process. To increase measuring accuracy, the density and enthalpy values are determined for every measurement and integrated into the calculation. Storing the consumption values The heat consumption values are continually cumulated. The current status is stored at 00.00 h on the due date. The due date can be set with the aid of a programming key; January 1 is set as the standard due date (see «Ordering» section) When the annual consumption is stored, the heat meter calculates a plausibility figure. This can be read out together with the due date value and checked in the billing program. This allows incorrect display readouts (e.g. switched digits ) to be detected. The stored due date value remains in place for one year. 6/12

Display Device states, display units and consumption values are shown via the LC display on several levels (up to 5 levels). The heat meter is equipped with a key that can be used to switch between the individual display steps and levels. The display includes the following values: ~ ~ Current heat quantity and, with G21, cold quantity ~ ~ Display test ~ ~ Old value heat quantity and, with G21, cold quantity ~ ~ Check number heat quantity and, with G21, cold quantity ~ ~ Due date ~ ~ Cumulated volume ~ ~ Current flow ~ ~ Supply flow temperature ~ ~ Return flow temperature ~ ~ Temperature difference ~ ~ Current energy flow ~ ~ Operating hours ~ ~ High-resolution heat quantity ~ ~ Volume per input impulse ~ ~ Software status ~ ~ Any module installed ~ ~ Storage date and consumption values for the last 18 months for quantity of heat and cold (with G21) Display level 0 Current heat quantity Segment test everything on Segment test everything off Standard display Old value heat quantity (meter count on the due date) Check number heat quantity (plausibility figure reg. old value) Due date (day the old value is formed) Current cooling quantity Old value cooling quantity (meter count on the due date) Optional display for combined heat/cold meter (G21) Old value cooling quantity (plausibility figure reg. old value) 7/12

Display level 1 Cumulated volume Current flow Supply flow temperature Return flow temperature Standard display Temperature difference Current energy flow Operating hours (since factory test) Display level 2 High-resolution heat quantity Volume per input impulse Software status Standard display Module: not installed (no integrated module) Module: M-Bus (primary address = 012) Module: Impulse output (impulse value = 1 kwh) Optional display. Depending on the module installed or heat meter type, this display appears additionally. 8/12

Display level 3 Storage date Latest monthly value Standard display Respective monthly value Heat quantity 18 monthly values Storage date Oldest monthly value Respective monthly value Display level 4 Storage date Latest monthly value Respective monthly value Optional display. Depending on the module installed or heat meter type, this display appears additionally. Cooling quantity 18 monthly values Storage date Oldest monthly value Respective monthly value Special displays for error messages The heat meter is self-monitoring and can display errors established. Battery warning These messagse alternate with the current display. Error message with error code 9/12

Measurement Loss of pressure curve Loss of pressure in bar Sensor Q n 0.16 / 1.5 Sensor Q n 2.5 Flow rate q in l/h Technical data Norms and standards CE conformity Directive 1995/5/EC (R&TTE Directive) Legislation concerning radio systems and telecommunications equipment (FTEG) Electromagnetic compatibility Interference resistance EN 61000-6-2 Emitted interference EN 61000-6-3 Protection rating IP protection rating IP54 according to EN 60529 Heat meter European Measuring Instruments Directive (MID) Heat meter 2004/22/EC EN1434 Quality of heat medium VDI guideline 2035 10/12

Technical data General device data Flow conditions G20 / G21 G20 / G21 G20 / G21 Nominal flow Q n 0.6 m³/h 1.5 m³/h 2.5 m³/h Installation position horizontal/vertical horizontal/vertical horizontal/vertical Metrological class B (opt. C) B (opt.c) B (opt. C) Start-up 3 l/h 4 l/h 5 l/h Dynamics Q n /Q min 50:1 (100:1) 50:1 (100:1) 50:1 (100:1) Minimum flow Q min 0.012 (0.006) m³/h 0.030 (0.015) m³/h 0.050 (0.025) m³/h Maximum flow Q max 1.2 m³/h 3.0 m³/h 5.0 m³/h Loss of pressure at Q n < 0.04 bar < 0.22 bar < 0.24 bar Nominal pressure PN 16 bar 16 bar 16 bar Nominal diameter DN 15 DN 15 DN 20 Connection sizes and dimensions Installed length 110 mm 110 mm 130 mm Connection thread on meter G 3/4 G 3/4 G 1" Temperature range 5-90 C 5-90 C 5-90 C Maximum temperature (for brief periods) 110 C 110 C 110 C Calibrated temperature difference 3-70 K 3-70 K 3-70 K Minimum temperature difference 1.0 / 0.2 K 1.0 / 0.2 K 1.0 / 0.2 K Type of temperature sensor PT 1000 PT 1000 PT 1000 Cable length of temperature sensor 1.5 (opt. 3.0) m 1.5 (opt. 3.0) m 1.5 (opt. 3.0) m Energy supply Lithium battery Lithium battery Lithium battery Service life > 6 (opt. 10) years > 6 (opt. 10) years > 6 (opt. 10) years Protection rating IP 54 IP 54 IP 54 Display levels 4 / 5 4 / 5 4 / 5 Display 7-digit LCD 7-digit LCD 7-digit LCD Energy display kwh (opt. MJ, GJ) kwh (opt. MJ, GJ) kwh (opt. MJ, GJ) 11/12

Dimensional drawing Qundis GmbH Sondershäuser Landstraße 27 99974 Mühlhausen / Germany Tel.: +49 (0) 3601 46 83-0 Fax: +49 (0) 3601 46 83-175 Mail: info@qundis.com Bahnhofstraße 10 78112 St. Georgen / Germany Tel.: +49 (0) 7724 93 89-0 Fax: +49 (0) 7724 93 89-310 Mail: info@qundis.com 12/12 The information in this data sheet only contains general descriptions or product characteristics, which may not always apply in particular application cases and/or may be subject to change through further development of the product. Required product characteristics are then binding if they are expressly agreed when the contract is drawn up. 2010 QUNDIS GmbH. Subject to change www.qundis.com Screw-type heat meter G20/G21 DST1-QHEA-GB0 G2x