MINI-SYS-PS AC/24DC/1.5

Similar documents
Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

PHOENIX CONTACT - 01/2007

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Redundancy Module QUINT-DIODE/40

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

MINI MCR-SL-R-UI(-SP)

PHOENIX CONTACT Features

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

RM4TG20 three-phase network control relay RM4-T - range V

Safety technique. Emergency stop module BO 5988 safemaster

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

LOGO!Power. Power supply. LOGO!Power. Overview. Description, device design, dimension drawing. Mounting/Disassembly 2

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Three-phase monitoring relay CM-PFE

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

PSI-REP-PROFIBUS/12MB

PLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet _en_02. 1 Description

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

48 SERIES Relay interface modules 10 A

38 Series - Relay interface modules A

Power Supplies 3. SDN-P DIN Rail Series

Product and functional description

Electronic overload relay EF19 and EF45

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

49 Series - Relay interface modules A. Features

38 Series - Relay interface modules A

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

E-STOP relays, safety gate monitors

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Electronic overload relay EF65, EF96 and EF146

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

MasterINTERFACE 39 Series - Relay interface modules

Relés e Contatores de Estado Sólido SIRIUS

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Digital input modules

PHOENIX CONTACT

Modular I/O System Analog and Digital Interface Modules

Thermistor motor protection

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MasterINTERFACE 39 Series - Relay interface modules

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

PNOZsigma - Base units

SYSTEM DESCRIPTION Termination Boards

7 - Phaseo power supplies and transformers

R.C.C.B. s two-pole LEXIC

Contact expander modules

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

SURGE PROTECTIVE DEVICES

E-STOP relays, safety gate monitors

Contact expansion modules

Cross-beam scanning system to detect slim objects. 100 mm in

80 Series - Modular timers 16 A. Features

Type: DILM32 10(24V50HZ) Article No.:

TX OPEN RS232/485 module

Analog signal converters CC-E I/I Current / current isolators

Operating Manual UWAPS-TINY Series

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

is then retained absolutely without interruption.

E-STOP relays, safety gate monitors

CompactLogix Power Supplies Specifications

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

J TB/TW Temperature limiter, temperature monitor

Control Devices Catalogue. Control Devices. Preferred and Standard Products

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

TEP 200WIR Series, Watt

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

APD / Outputs 19" DC/DC Converter, 50 Watt

Transcription:

Power supply unit, primary switched-mode INTERFACE Data Sheet 102050_01_en PHOENIX CONTACT - 11/2006 Description With the MINI-SYS-PS power supply, additional modules can be supplied with 24 DC using the optional DIN rail connectors. The low design depth of 95 mm is a particular advantage for use in surroundings with a low height. The system power supply particularly simplifies the power supply of the FO transmission system PSI-MOS as well as of the analog 6 mm MCR measuring transducer. In this way it emphasizes the seamless character of the INTERFACE product range. Even without the DIN rail connector, the flat power supply unit 24 V/1.5 A is suitable for many applications in areas in which space is restricted, as the housing is 12 mm flatter than other comparable solutions. The electronic short circuit and idling-proof device is connected to single-phase AC networks with nominal voltages of 100 V AC to 240 V AC or to two of the phase conductors of three-phase networks with a linked voltage of this value. In the event of a malfunction, the output voltage is limited to 30 V DC. Due to the U/I characteristic curve with POWER BOOST, miniature circuit breakers blow reliably. For function monitoring, there is the floating DC OK output and the DC OK LED. High operational reliability is provided by the mains failure bridging time of more than 20 ms under full load. Ambient temperatures can be in the range of -25 C to +70 C, whereby the power reserve of approx. 25% up to 40 C is permanently available. Danger! Components with dangerously high voltage and high stored energy are located in the device! Never carry out work on live parts! Depending on the ambient temperature and the load, the housing can become very hot! Make sure you always use the the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf.

Order data Description Type Order No. Pcs./Pkt. Power supply unit, primary switched-mode MINI-SYS-PS-100-240AC/24DC/1.5 2866983 1 Accessories Type Order No. Pcs./Pkt. Bus connector, gold-plated contacts, for mounting on DIN rail, 5-pos. ME 17,5 TBUS 1,5/ 5-ST-3,81 GN 2709561 10 Technical data Input data Input nominal voltage range 100 V AC... 240 V AC AC input voltage range 85 V AC... 264 V AC AC frequency range 45 Hz... 65 Hz Current consumption Approx. 0.75 A (120 V AC) Approx. 0.45 A (230 V AC) Inrush current limitation/i 2 t < 15 A (0.6 A 2 s) Power failure bypass > 20 ms (120 V AC) > 100 ms (230 V AC) Typical response time < 0.5 s Protective circuitry Transient surge protection, varistor Input fuse, integrated 3.15 A (slow-blow, internal) Recommended backup fuse for mains protection 6 A (power circuit-breaker, characteristic B) 10 A (power circuit-breaker, characteristic B) 16 A (power circuit-breaker, characteristic B) Output data Nominal output voltage 24 V DC ±1% Output current 1.5 A (up to 60 C) 2 A (with POWER BOOST) Derating From +60 C 2.5% per Kelvin Output current limit 7 A (in the event of a short circuit) Max. capacitive load Unlimited Control deviation < 1 % (change in load, static 10%... 90%) < 3 % (change in load, dynamic 10%... 90%) < 0.1 % (change in input voltage ±10%) Power loss nominal load max. 12 W Maximum power dissipation idling 2.5 W Efficiency > 84 % (for 230 V AC and nominal values) Ascent time < 2 ms Residual ripple < 40 mv SS (20 MHz) Peak switching voltages < 20 mv SS (20 MHz) Connection in parallel Yes, for redundancy and increased capacity. Maximum of 2 devices for redundancy on DIN rail connector. Surge protection against internal surge voltages Yes, < 30 V DC Resistance to reverse feed 35 V DC 102050_01_en PHOENIX CONTACT 2

Signal output DC OK floating Output description Continuous current Output voltage Status display U OUT > 21.5 V: Contact closed 1 A 30 V AC/DC LED green (U out > 21,5 V DC: LED permanently lit) Standards Electrical Equipment for Machinery EN 60204 Safety transformers for power supply units EN 61558-2-17 Electrical safety (of information technology equipment) EN 60950/VDE 0805 (SELV) UL/C-UL recognized UL 60950 Industrial control equipment UL/C-UL Listed UL 508 Electronic equipment for use in electrical power installations EN 50178/VDE 0160 (PELV) SELV EN 60950 (SELV) and EN 60204 (PELV) Safe isolation DIN VDE 0100-410 Protection against electric shock, basic requirements for safe isolation in DIN VDE 0106-101 electrical equipment Limitation of mains harmonic currents EN 61000-3-2 Approvals Granted approvals Granted approvals for potentially explosive areas u U General data Insulation voltage input/output 3 kv (routine test) 4 kv (type test) Installation position On horizontal DIN rail NS 35 in acc. with EN 60715 Degree of protection IP20 Class of protection II (in an enclosed control cabinet) MTBF > 500 000 h in acc. with IEC 61709 (SN 29500) Housing version Polyamide PA, color: green Width 35 mm Height 99 mm Depth 95 mm Weight 0.25 kg Climatic data Ambient temperature (operation) -25 C... 70 C (> 60 C derating) Ambient temperature (storage/transport) -40 C... 85 C Max. permissible. relative humidity (operation) 95 % (at 25 C, no condensation) Vibration (operation) < 15 Hz, amplitude ±2.5 mm in acc. with IEC 60068-2-6 15 Hz... 150 Hz, 2.3g, 90 min. Shock 30g in all directions in acc. with IEC 60068-2-27 Pollution degree in acc. with EN 50178 2 Climatic class 3K3 (in acc. with EN 60721) 102050_01_en PHOENIX CONTACT 3

Conformance with EMC directive 89/336/EEC Immunity to interference in acc. with EN 61000-6-2 Discharge of static electricity in acc. with EN 61000-4-2 Housing Level 3 Contact discharge 6 kv Discharge in air 8 kv Criterion B Electromagnetic HF field in acc. with EN 61000-4-3 Housing Level 3 Frequency range 80 MHz... 2 GHz Field intensity 10 V/m Criterion A Fast transients (burst) in acc. with EN 61000-4-4 Input 4 kv (level 4 - asymmetrical: conductor to ground) Output 2 kv (level 3 - asymmetrical: conductor to ground) Signal 1 kv (level 2 - asymmetrical: conductor to ground) Criterion B Surge voltage capacities (surge) in acc. with EN 61000-4-5 Input 4 kv (level 4 - asymmetrical: conductor to ground) 2 kv (level 4 - symmetrical: conductor to conductor) Output 0.5 kv (level 1 - asymmetrical: conductor to ground) 0.5 kv (level 1 - symmetrical: conductor to conductor) Signal 0.5 kv (level 1 - asymmetrical: conductor to ground) Criterion B Conducted disturbance in acc. with EN 61000-4-6 Input/Output/Signal Level 3 - asymmetrical Frequency range 0.15 MHz... 80 MHz Voltage 10 V Criterion A Voltage dips in acc. with EN 61000-4-11 Input (mains buffering > 20 ms) Criterion B Emitted interference in acc. with EN 61000-6-3 Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential Note: Criterion A: Normal operating behavior within the defined limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself EN 55011 corresponds to CISPR11 / EN 55022 corresponds to CISPR22 EN 61000 corresponds to IEC 1000 102050_01_en PHOENIX CONTACT 4

Block diagram Structure 1 4 IN AC 100-240 V DC OK MINI SYS POWER 24V 13 14 OUT DC 24V 1.5A 24V 0V 0V 2 3 1 AC input 2 DC output 3 DC OK output, floating 4 DC OK control lamp 5 Universal snap-on foot for EN DIN rails 6 Connection option for DIN rail connector 33 34 71 72 63 64 www.interface.phoenixcontact.com DC: 90-350V 0.4-0.2A Read installation instructions before connecting to mains LISTED 100-240V 50-60Hz Range: 85-264V 1.1-0.38A CONTROL EQUIPMENT 43KA TECHNOLOGY EQUIPMENT U INDUSTRIAL u INFORMATION 24V DC ±1% 1.5A APPROVALS INPUT OUTPUT AC: TEMPERATURE -25...+70 C -13... + 158 F (> + 60 C/+ 140 F Derating) Power Supply Order No.: 28 66 98 3 MINI-SYS-PS-100-240AC/24DC/1.5 6 [mm 2 ] AWG [Nm] solid stranded Torque Input 0.2-2.5 0.2-2.5 24-12 0.5-0.6 Output 0.2-2.5 0.2-2.5 24-12 0.5-0.6 Signal 0.2-2.5 0.2-2.5 24-12 0.5-0.6 5 Input data Input nominal voltage range 100 V AC... 240 V AC AC input voltage range 85 V AC... 264 V AC AC frequency range 45 Hz... 65 Hz Input fuse, integrated 3.15 A (slow-blow, internal) Recommended backup fuse for mains protection 6 A (power circuit-breaker, characteristic B) 10 A (power circuit-breaker, characteristic B) 16 A (power circuit-breaker, characteristic B) Type of connection COMBICON screw/plug connection Stripping length 7 mm Output data Nominal output voltage 24 V DC ±1% Output current 1.5 A (up to 60 C) 2 A (with POWER BOOST) Type of connection COMBICON screw/plug connection Stripping length 7 mm 102050_01_en PHOENIX CONTACT 5

Safety and warning notes The power supply units are built-in devices. The device may only be installed and put into operation by qualified personnel. The corresponding national regulations (e.g. VDE, DIN) must be observed. Installation Danger! Components with dangerously high voltage and high stored energy are located in the device! Never carry out work on live parts! Depending on the ambient temperature and the load, the housing can become very hot! Before startup please ensure: The mains connection has been carried out by a competent person and protection against electric shock is guaranteed! The device can be disconnected outside the power supply unit in accordance with the regulations as in EN 60950 (e.g. through primary side line protection)! All feed lines are sufficiently protected and dimensioned! All output lines are dimensioned according to the maximum output current of the device or separately protected! Sufficient convection is guaranteed! In order to guarantee sufficient convection, we recommend observing the following minimum distance to other modules: 5 cm in a vertical direction and 0 cm in a horizontal direction. MINI-SYS-POWER 24V 0V 0V 24V 13 14 OUT DC 24V 1.5A 24V 0V 0V DC OK 24V 13 14 63 64 71 72 MINI-SYS-PS-100-240AC/24DC/1.5 Order No.: 28 66 98 3 Power Supply CONTROL EQUIPMENT 1YD8 U INDUSTRIAL LISTED APPROVALS INPUT OUTPUT AC: 100-240V 24V DC 50-60Hz ±1% Range: 1.5A 85-264V 0.4-0.2A DC: 90-350V 0.4-0.2A TEMPERATURE - 25 + 60 C - 13 + 140 F 25 TECHNOLOGY EQUIPMENT u INFORMATION Read installation instructions before connecting to mains www.interface.phoenixcontact.com The power supply unit can be snapped onto all DIN rails in acc. with EN 60715. They must be horizontal (connecting terminal blocks above and below). IN AC 100-240 V 102050_01_en PHOENIX CONTACT 6

MINI-SYS-POWER MINI-SYS-PS-100-240AC/24DC/1.5 Installation position 35 50 102.5 95 24V 13 14 OUT DC 24V 1.5A 24V 0V 0V 99 DC OK IN AC 100-240 V 50 199 Installation: Installation depth 95 mm (+ DIN rail) Assembly When the DIN rail connector ME 17,5 TBUS (Order no. 2709561, 2x required) is used, place this in the DIN rail first. Position the module with the DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward moti1on. Dismantling Pull the snap lever open with the aid of a screwdriver and slide the module out at the lower edge of the DIN rail. 102050_01_en PHOENIX CONTACT 7

Connection, network forms 100...240 V AC networks TN-S TN-C TT it L N PE L PEN L N L1 L2 L3 L N L N L N L N + - + - + - MINI MINI MINI MINI + - The 100...240 V AC connection is made using the L and N screw connections. The device can be connected to 1-phase AC systems or to two of the phase conductors of three-phase systems (TN, TT or IT networks in acc. with VDE 0100-300/IEC 60364-3) with nominal voltages of 100 V AC...240 V AC. For operation on two of the phase conductors of a three-phase system, an isolating facility for all poles must be provided. Input 1 33 34 IN AC 100-240 V 63 64 DC OK MINI SYS DC: 90-350V 0.4-0.2A 100-240V 50-60Hz Range: 85-264V 1.1-0.38A 24V DC ±1% 1.5A INPUT OUTPUT AC: Protection of the primary side The device must be installed in acc. with the regulations as in EN 60950. It must be possible to disconnect the device using a suitable isolating facility outside the power supply. The primary side line protection, for example, is suitable. For device protection, there is an internal fuse. Additional device protection is not necessary. Recommended backup fuse for mains protection Power circuit-breaker 6 A, 10 A or 16 A, characteristic B (or identical function). 71 72 www.interface.phoenixc Read installation ins before connecting LISTED CONTROL EQUIPMENT 43KA u IN T U INDUSTRIAL APPROVALS TEMPERATURE -25... + 70 C -13...+158 (> + 60 C/+ 140 F Derat If an internal fuse is triggered, there is most probably a malfunction in the device. In this case, the device must be inspected in the factory! 102050_01_en PHOENIX CONTACT 8

Output DC OK MINI SYS POWER 24V 13 14 OUT DC 24V 1.5A 24V 0V 0V 2 Make sure that all output lines are dimensioned according to the maximum output current or are separately protected. The cables on the secondary side must have sufficiently large cross sections in order to keep the voltage drops on the lines as low as possible. C 100-240 V N 63 64 DC: 90-350 0.4-0 1.1-0.38A 100-240V 50-60Hz Range: 85-264V 24V ±1 1 INPUT OUTPUT AC: Pow Order No.: MINI-SYS They are connected using the "24 V" and "0 V" screw connections on the screw connection of the DC output and via the DIN rail connector. Protection of the secondary side The device is electronically protected against short circuit and idling. In the event of a malfunction, the output voltage is limited to 30 V DC. Signaling For function monitoring, there is the floating DC OK switching output and the DC OK LED. State 1 State 2 DC OK LED ON OFF Floating DC OK output Closed Open Meaning Normal operation of the power supply (U OUT > 21.5 V) 1. The output voltage is less than 21.5 V. There is a secondary consumer short circuit or overload. 2. There is no input voltage or there is a device fault. Output 24 V DC 13 14 24V 0V 0V 24V Floating contact The floating signal contact opens and signalizes a drop in the output voltage of 21.5 V. Signals and ohmic loads of up to 30 V and currents of up to 1 A can be connected. For heavily inductive loads such as a relay, a suitable protection circuit (e.g. damping diode) is necessary. max. 30 V AC/DC, 1 A DC OK 102050_01_en PHOENIX CONTACT 9

Function UOUT [V] U N < 60 C < 40 C I N I BOOST I OUT [A] Output characteristic curve The device can supply a nominal output current of 1.5 A with ambient temperatures of up to 60 C. At an ambient temperature of up to 40 C, the device supplies a continuous output current of 2 A. At temperatures up to 60 C, the POWER BOOST provides a transient output current of 2 A for a few minutes. In the event of a higher load, the operating point follows the U/I characteristic curve depicted in the figure. In the case of overload or short-circuit, the full output current I BOOST is supplied permanently with reduced output voltage, the device does not switch off. As soon as the overload or short-circuit is no longer present, the full secondary voltage is once again available. The U/I characteristic curve ensures that both heavily capacitive loads and devices with DC/DC converters in the primary circuit can be fed without problems using MINI POWER. Downstream fuses are triggered reliably. Selectivity in the design of your system is guaranteed at all times. U N = 24 V I N = 1.5 A I BOOST = 2 A Thermal behavior With an ambient temperature of up to +60 C, the device supplies the continuous output current of I N. In the case of ambient temperatures above +60 C, the output current must be reduced by 2.5% per Kelvin increase in temperature. The device does not switch off at ambient temperatures of +70 C or thermal overload. The output capacity is reduced as far as necessary to provide device protection. After it has cooled down, the output capacity is increased again. Output current [A] I BOOST I N 0 0 20 40 60 Ambient temperature [ C] 102050_01_en PHOENIX CONTACT 10

Parallel operation Due to the current carrying capacity, a maximum of two devices may be connected in parallel on the DIN rail connector for redundancy. Without using the DIN rail connector, devices of the same type can be connected in parallel both for redundancy reasons as well as to improve performance. To ensure symmetrical distribution of power, we recommend designing all cable connections from the power supply unit to a busbar of the same length and with the same conductor cross section. The system makes it advisable to install a protective circuit at the output of each device when more than two power supply units are connected in parallel (e.g. decoupling diode or DC fuse). This prevents high reverse feed currents in the event of a secondary device fault. + I N I N + + + Σ =I N Redundant operation Redundant circuits are suitable for the supply of systems which make especially high requirements on the operational safety. If a fault occurs in the primary circuit of the first power supply unit, the second device automatically takes over the entire power supply, without interruption, and vice versa. For this reason, the power supply units to be connected in parallel are dimensioned in such a way that the total current requirement of all consumers can be completely covered by one power supply unit. 100% redundancy makes external decoupling diodes necessary (QUINT-DIODE/40, Order No. 2938963)! + I N I N + + Increased performance For n parallel connected devices, the output current can be increased to n x I N. Parallel connection to increase efficiency is used for the expansion of existing systems. It is advisable to use parallel connection if the power supply unit does not cover the current requirement of the most powerful consumer. Otherwise the consumers should be spread among individual devices independent of one another. A maximum of five devices can be connected in parallel! + Σ =2xI N 102050_01_en PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany PHOENIX CONTACT 11 Phone: +49-(0) 5235-3-00 Fax: +49-(0) 5235-3-4 12 00 www.phoenixcontact.com