GT11 Series-to-FR-A 700 Inverter

Similar documents
How to connect your Victron to a computer with VE Bus Quick Configure

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

The new 5.7 standard model

How to read this guide

IGSS. Interactive Graphical SCADA System. Quick Start Guide

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

Read Me UNISTREAM AUTOMATION IDE

How to setup a serial Bluetooth adapter Master Guide

USB2VGA. Instruction Manual. USB to VGA Adapter. USB 2.0 to VGA External Multi Monitor Video Adapter

Plena Voice Alarm System Firmware update

U90Ladder / VisiLogic /UniLogic and software utilities system requirements. Contents

Keep it Simple Timing

Schneider OS-Loader usage via Ethernet or USB.

GV- RK1352 Card Reader

DUKANE Intelligent Assembly Solutions

USB 3.0 Universal Mini Docking Station Adapter

Fiery E100 Color Server. Welcome

WindO/I-NV2 Utility Pass-Through Tool

Network/Floating License Installation Instructions

Phone: Fax: Web: info@ctiautomation.net

DiCE INSTALLATION INSTRUCTION

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

Configuring Windows 7 64 bit for AutoVISION

Modicon M340 Firmware

7.7 Ethernet Communication (AFPX-COM5)

Setting Up the ZigBee Ethernet Gateway

Custom Solutions Center. Users Guide. Low Cost OEM PackML Templates L02 Release. Version LC-1.0

NVIDIA Graphics Card and Driver Installation Guide (Windows NT 4.0 and Windows 2000)

US-122L/US-144 Release Notes

The Wireless LAN (Local Area Network) USB adapter can be operated in one of the two following networking configurations :

User Manual. AS-Interface Programmer

1 DVR 670 Series firmware version (date )

SA-9600 Surface Area Software Manual

Ultra Thin Client TC-401 TC-402. Users s Guide

Install Device Drivers and Toolkit for Windows 7

Easy! Smooth! GP/ST-3500 Series->GP4000 Series Replacement Guidebook

PN-L702B LCD MONITOR TOUCH PANEL DRIVER OPERATION MANUAL. Version 2.1

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Yamaha 01V96 Version2 Upgrade Guide

Using the VEX Cortex with ROBOTC

How to use the VMware Workstation / Player to create an ISaGRAF (Ver. 3.55) development environment?

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

HOW TO TRANSFER FILES BETWEEN EEN IDL7000 PVR AND USB2 DEVICE

USB to VGA Adapter USB2VGAE2. Instruction Manual. USB 2.0 to VGA Multi Monitor External Video Adapter

1 Serial RS232 to Ethernet Adapter Installation Guide

Title Page. Reflex USB v2. Reader Installation Guide

Job Aid Pre-Installation Information S8500 Media Server

How to install USB driver (MICRO/I)

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

FTDX1200 Firmware Update Manual

FT-991 Firmware Upgrade Manual

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2

PRINTER DRIVER GUIDE (KODAK 305 Photo Printer)

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Setup and Programming of the. Master Module R72-11Z-SLSASG-028

ScreenBeam Wireless Display Kit. User Manual. Solutions for the Digital Life. Model #: SBWD100KIT. Ver 1.0

X Series Application Note 43:

COPYRIGHT TOP NOTCH TABLETS LLC HOW TO: Install the Drivers to your PC so you can Flash Firmware to your RK3066 Powered Tablet.

Network Video Recorder. User s Manual v Model: SVR-504/508/516/516+

How to install USB driver (MICRO/I)

Human Machine Interface

Quick Start Guide. DVR DS-7200HWI-SH Series DVR. First Choice For Security Professionals

The following pages will help you to solve issues linked to the installation and first use of the Wintech Manager software and Wintech USB computer.

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Mastertech Diagnostic Software Frequently Asked Questions

Fusion. User s Guide: Updating the Fusion s Image

Screen Capture. User s Guide. For ClassPad Series

WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4

SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

PM1122 INT DIGITAL INTERFACE REMOTE

EZ-View Network Communications Guide

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

Connecting your Omega/BetaPAT PLUS to a PC via a USB

ADDENDUM - Bluetooth interface Option Instructions for using Extech Printer with a Bluetooth device

Computer Requirements

Firmware Update Instruction Manual

SMART Board Software for Macintosh FAQ

OWNERS MANUAL. WattsVIEW. Power Monitor Model: DC WattsVIEWTM. Models: DC Serial DC-1000 USB DC-25000

Communication Setup Application Note

Gauge Drawing Tool Slider Drawing Tool Toggle Button Drawing Tool One-Way List Drawing Tool... 8

Calrec SoundGrid I/O. User Guide

CENTRONICS interface and Parallel Printer Port LPT

Operation and Maintenance Terminal (OMT 1.2) User s Manual for use with MPW

Remote Deposit Capture Installation Guide

COLOR TFT LCD MONITOR. User Manual

OVERVIEW Playbacks: Shortcuts: Memories: Data Entry Wheels: Touchpad: Master and Blackout:

Phaser 3635MFP Software Upgrade Process

VisionView Maintenance Utility Release Notes

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

1 Technical Description Lokal-200PC

How do I configure the wireless printer using a USB or Ethernet cable and install the printer driver in Windows?

Wattbike Power Cycling Studio Edition. User Manual

Mobile Video Analysis Software User Guide. Version 2.0.8

8/23/13 Configuring the S7 Server for Windows NT 4.0 to Access S7-400 PLCs via the Siemens CP1613 Card for ISO (Industrial Ethernet)

Wired / Wireless / PoE. CMOS Internet Camera ICA-107 / ICA-107W / ICA-107P. Quick Installation Guide

T3 Mux M13 Multiplexer

FINS Gateway For OMRON PLCs

Transcription:

START-UP GUIDE GT11 Series-to-FR-A 700 Inverter 1

GOT1000 Startup Guide GT11 Series-to-FR-A 700 Inverter Ver. A Overview: This document provides a simple guide to setting up the GT11 Series Graphic Operation Terminal (GOT) hardware and firmware for use with an FR-A 700 Inverter. Hardware Introduction: The GT11 Series are 5.7, 320 x 240 dot resolution, three built-in communication channel GOT1000 Series touch panel interfaces. GT11 Series terminals also have Compact Flash card interfaces and a Reset button built-in. The models that are connectable to FREQROL inverters as follows: Model Display Type Comm. IF Power GT1155-QTBD 256 Color TFT USB (slave) GT1155-QSBD 256 Color STN RS-232C 24V DC GT1150-QLBD 16-gradient Grayscale STN RS-422 For new GT11** Series terminals, included in the box should be the GT11** (A), and a sealed plastic bag containing 1 rubber Dust-/Water-Proof Packing, 4 metal Mounting Brackets, and 4 M4 Mounting Screws. A B Cabling: Power All GT11 Series GOTs require an external 24V DC power supply to be connected to the Power Terminals on the back of the GOT. 2

Communication For the GT11 terminal to communicate with the inverter, a communication cable is required. The type of cable used is dependent on the number of inverters used within the system, examples of which are illustrated below. One inverter: (A) Multi-drop connection: (C) (D) (D) (D) (A) *1 Connect to the PU port of the inverter. Key: (A) (C) (D) RS-422 Between inverter and GOT RS-422 Between distributor and inverter or between distributors RS-422 Mounting a terminating resistor Distributor 3

When wiring to the inverter s 485 terminal: One inverter: (E) Multi-drop connection: (F) (E) *2 Connect to Terminal block Key: (E) (F) RS-422 Between inverter and GOT RS-422 Between inverters and GOT * Cables to be made by user ** For direct wiring to RS-485 terminal blocks refer to respective product manual. 4

GOT Inverter Wiring Diagrams (A) (C) *1 The connector figure shows the engagement face. (E) 5

(F) - Set the terminator switch built in the farthest inverter from the GOT to ON (100Ω). Programming Cables: The GT11 Series GOTs come pre-installed with an OS only and without any project data. To download a project from a PC running GT Designer2 to the GOT, a programming cable is required to connect the PC to one of the communication interfaces. For a new out-of-the-box GOT, the easiest way to connect to the GOT is through the USB Mini-B type port on the front panel with a standard USB cable. After setting up the GOT communication settings from the GOT main menu or with GT Designer2, the RS-422 and RS-232C interfaces can also be used for program transfer. Connection via USB is shown below. PC USB GOT GT Designer 2 (Version 2.73 or later) To make sure the GT11 Series GOT is able to use the latest functions and features, it is the responsibility of the user to check and update the firmware (Standard monitor OS) of the GOT. Launch the latest copy of GT Designer2 and start a new project for the GOT model GT11**-Q(320x240) with the with the FREQROL500/700 Inverter Type. Select Yes to set the Communication Setting and make sure the Standard I/F-1 CH No. is set to 1 before selecting OK. The Screen Property window that pops up for making a new screen can be either canceled or accepted for the following steps. 6

Go to the Communication menu and select To/From GOT to bring up the Communicate with GOT window. Go to the Communication configuration tab and select RS232 and the corresponding Port No. that connects the PC to the GOT. With the GOT power ON, use the Test button to verify that the PC and GOT can communicate properly then turn the GOT power OFF. Go to the OS Install -> GOT tab in the Communicate with GOT window of GT Designer2 and select Standard monitor OS and Communication driver FREQROL 500/700 [**.**.**] from the data selection tree. Use the Install button to initiate the data transfer and update the firmware. Once the firmware update has been completed the GOT will automatically reboot and all features will be up to date. Note that new project data will need to be downloaded to the GOT. 7

Inverter Settings When setting the inverter communication parameters it is important to reset the power afterwards so that the settings are saved to the inverter. The parameters shown in the following table must be set using the PU (Parameter Unit). Note: Do not change these parameters, even though it is possible to monitor them through the GOT. If they are changed, communication with the GOT is disabled. Setting item PU communication station number/rs-485 communication station number PU communication speed/ speed*2 PU communication stop bit length/ stop bit length*2 PU communication parity check/rs-485 communication parity check*2 Number of PU communication retries/ retry count PU communication check time interval/ check time interval PU communication waiting time setting/ waiting time setting PU communication CR/LF selection/ CR/LF selection Parameter Set Value Setting Contents PU Connector RS-485 Pr.117 Pr.331 0-31 See following section Pr.118 Pr.332 192 19200bps Pr.119 Pr.333 10 Data length: 7bit Stop bit length: 1bit Pr.120 Pr.334 1 Odd Pr.121 Pr.335 9999 The inverter will not come to an alarm stop. Pr.122 Pr.336 9999 Communication check Suspension Pr.123 Pr.337 0 0ms Pr.124 Pr.341 1 With CR, without LF Protocol selection - Pr.549 0 Mitsubishi inverter protocol Operation mode Pr.79 PU 1 PU operation mode selection connector RS-485 0 External operation mode at power on Link start mode selection Pr.340 PU 0 Refer to Pr.79 settings. connector RS-485 1 Network operation mode. Communication EEPROM write selection Pr.342 0 Written to RAM and EEPROM 8

Station Setting Set each station number while making sure that each station number is used only once. The station number can be set regardless of the cable connection order. Station numbers do not have to be consecutive. The setting of the Station number has to be between 0-31. Indirect specification When setting the station number indirectly, the station number of the inverter can be changed using the 16-bit GOT internal data register (GD10 to GD25). When specifying the station No. from 100 to 155 on GT Designer 2, the value within GD10 to GD25 is equal to the station No. Specification Compatible Device station no. 100 GD10 101 GD11 102 GD12 103 GD13 104 GD14 105 GD15 106 GD16 107 GD17 108 GD18 109 GD19 110 GD20 111 GD21 112 GD22 113 GD23 114 GD24 115 GD25 Setting range 0 to 31 If the associated device contains a value outside this range an error (dedicated device is out of range) will occur. 9

Confirm Communication Before downloading project data to the GOT, the I/O Check function can be used to verify that the GOT is communicating properly with the PLC. After pressing the CPU button, if no error is shown, communication has been set up correctly. Manual References: Refer to the following manuals for more detailed explanations. For any further questions, please contact your local Mitsubishi Product Provider. GOT1000 Series Connection Manual 3/3 (SH(NA)-080532ENG) - Sections 32.1, 32.2, 32.3, 32.4, 32.5 & 32.6 Inverter FR-A 700 Instruction Manual (Applied) (IB(NA)-0600257ENG-B) 10