USE, CARE AND MAINTENANCE OF MICROSCOPES

Similar documents
MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

MALARIA PARASITE COUNTING

Care and Use of the Compound Microscope

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

THE COMPOUND MICROSCOPE

EXPERIMENT #1: MICROSCOPY

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

OPERATING INSTRUCTIONS XJL 101/101A REFLECTED LIGHT METALLURGICAL MICROSCOPE

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

Compound microscope (Hund)

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Exercise 2. The Compound Light Microscope

How To Use An Asbestos Microscope

VISM CQB Scope Series

Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

74 Chapter CO 2 Cleaning

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

18-270mm F/ Di II VC PZD for Canon, Nikon (Model B008) mm F/ Di II PZD for Sony (Model B008)

Infrared Viewers. Manual

VISM Evolution Scope Series

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

Features: Mounting the Optic

Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!

Microscopy and Cellular Morphology

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

NIGHT VISION MONOCULAR PHANTOM

Care and Handling of Your VAIO Computer

Microscope Lab Introduction to the Microscope Lab Activity

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

MACRO PHOTO LENS. MP-E 65mm f/ ENG. Instruction

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

EF70-300mm f/4-5.6 IS USM

OLYMPUS STUDENT MICROSCOPES INSTRUCTIONS ST. HS&HSC MODELS OLYMPUS

BIO 10 Lab 1 Introduction Pre Lab Test

FirstView 3 Reflector Telescope Owner s Manual

GLobAL Dental Microscopes. Dentists First Choice

EF-S18-135mm f/ IS

AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17)

Use of the Microscope and Cytology

ISO9001 ISO Environmentally-friendly product All optical components in CX41 microscope use lead-free eco-glass.

V-500-PRE. 500mm F/8.0 Telephoto Lens INSTRUCTION MANUAL

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Light and its effects

Installation and use of Millett Tactical TRS-1 and TRS-2 scopes TRS-1 TRS-2. Before starting, make sure firearm is UNLOADED!!

MIST DECORATIVE LAMP WITH ESSENTIAL OIL DIFFUSER

The Vortex Spitfire 1x Prism Scope

HISTOLOGY LABORATORY. Microscope Orientation and Blood Smear Lab

VICKERS HARDNESS TESTER. HBS HBW Kc

UV100A Ultraviolet Air Treatment System

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Leica DM300 User Manual

SP AF 90mm F/2.8 Di Macro 1:1 (Model 272E)

EF-S18-55mm f/ IS II COPY ENG. Instruction

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

3. Maintenance of Laboratory Equipment

Care and Maintenance for Wood Flooring

SP AF 17~50 mm F/2.8 XR Di-II LD Aspherical [IF] (Model A16)

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

Information. From the LowVision Specialists. Guidelines for the fitting of telescopic systems

EF70-200mm F2.8L IS USM. Instruction

euromex microscopen bv The Netherlands page1/16

3.1 Cells and cell function

3 WATT LED SPOTLIGHT Model No. SLM

TURN TABLES 1.5 TON CAPACITY / 2 PC. Model 45742

Please read and keep these instructions. Run water through your machine before first use

EF-S55-250mm f/4-5.6 IS STM COPY ENG. Instructions

A Fishy Tale. Observing the Circulatory System of a Goldfish with a Compound Light Microscope

Wine Cooler with Thermo-Electric Cooling & Heating Technology

microscope OP-Dent-5

EF24-105mm f/4l IS USM

LED Par 56 Short DMX ORDERCODE 42421

30 mm Diameter Main Tube 1-4x24 Models

ClearView+ User Manual

LED Par 56 Ultra Bright RGB Black ORDERCODE Polished ORDERCODE 42451

Handheld USB Digital Endoscope/Microscope

Heated throw User manual

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

15GAL STEEL OIL DRAIN WITH 110V PUMP

SMD Rework Station TABLE OF CONTENTS

DETECTION OF BACTERIAL MOTILITY. To demonstrate bacterial motility by microscopic and macroscopic techniques.

Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

STAINLESS STEEL WINE / BEVERAGE COOLER INSTRUCTION MANUAL HVBC31ST

OLYMPUS STUDENT MICROSCOPES IINSTRUCTION MANUAL I CBA& CBB MODELS

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Rauserv Steam Sterilizers, Laboratory and Hospital Equipment. Brewery Laboratory Equipment

Review: Amscope Metallurgical Trinocular Microscope. Michael Reese Much FRMS EMS Bethlehem, Pennsylvania USA

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Fitting Guide. Dallas Denver Tulsa

Educational Tool for Medical Laser Programs 1. Laser Safety

Transcription:

VERSION 1 EFFECTIVE DATE: 01/01/2016 USE, CARE AND MAINTENANCE OF MICROSCOPES MALARIA MICROSCOPY STANDARD OPERATING PROCEDURE MM-SOP-12 1. PURPOSE AND SCOPE To describe the general protocol for the use, care and maintenance of microscopes in laboratories in which malaria microscopy is performed This procedure is to be modified only with the approval of the national coordinator for quality assurance of malaria microscopy. All procedures specified herein are mandatory for all malaria microscopists working in national reference laboratories, in hospital laboratories or in basic health laboratories in health facilities performing malaria microscopy. 2. BACKGROUND Compound binocular light microscopes are recommended for malaria microscopy, with 10x and 40x objectives, an oil immersion 100x objective and 10x oculars. The maximum depth of field can be achieved only if the microscope light source has sufficient luminosity to allow the iris diaphragm to be closed optimally without loss of brightness. Preferably, it should have a built-in lamp, an adjustable condenser (a fixed condenser may be acceptable) and a daylight blue filter. The accuracy of malaria microscopy depends on the correct functioning and use of the microscope. Microscopes should be set up for optimal performance, protected from damage, used ergonomically, regularly maintained and, if required, repaired by qualified personnel. Care of microscopes is particularly important in facilities in areas that are dusty, where microscopes must be covered when not in use and before cleaning the floor to avoid damage to the microscope. 3. SUPPLIES, MATERIALS AND EQUIPMENT a compound microscope fitted with paired 10x oculars (eyepieces), 10x, 40x and 100x (oil immersion) objectives and a mechanical stage; a dust cover; lens paper; commercial microscope cleaning solution and a soft cloth. 4. PROCEDURE 4.1. Transporting and moving microscopes Transport microscopes in the original container with the internal packing materials to prevent it from moving within the container. If the original packaging is not available, use a specifically designed microscope transport box supplied by the manufacturer or a fabricated container containing foam or similar packing materials to prevent the microscope from moving within the container during transport. During transport, protect the microscope from excessive movement or vibration: pack it so that it does not move around in the vehicle and cannot fall from the top of other items being transported; protect the microscope from exposure to water (such as rain, flooding, falling into water), excessive heat, direct sunlight and rodents. Carry a microscope with two hands, one supporting the base and the other holding the arm.

4.2. Placement Place the microscope on a flat, level, firm bench, free from vibration. At high magnification, very small movements of the bench will cause large movements in the image being viewed by the microscopist. Place the microscope in a position where there is space for the microscopist to place his or her legs fully under the bench. Preferably use height-adjustable chairs. Do not place the microscope in front of a brightly lit window. Place it in front of a wall or a darkened window. 4.3. Microscope set-up Follow the manufacturer s directions for optimal set-up of the optical system and general use. Adjust the iris aperture to the setting recommended by the manufacturer to achieve maximum depth of field. If the manufacturer provides an iris diaphragm setting on the condenser, set this to the 100x objective lens setting. Use the following method if the eyepiece of the microscope can be removed: raise the condenser; set the lamp to low ; select the 40x objective; close the iris diaphragm; remove one eyepiece; look down the tube, then adjust the condenser until the edge of the diaphragm is in sharp focus without showing an outer fringe ring in green or in red; open the iris diaphragm until the objective lens completely fills with light; the shape of the light is usually octagonal; when the points of the octagon touch the outside of the objective lens, open the iris diaphragm until the light appears circular; replace the eyepiece. An alternative method, and one that does not require removal of the eyepieces, is to set the microscope into Kohler illumination. close the iris diaphragm on the condenser; close the light source at the base of the microscope, where the light is reflected up to the condenser; turn the light up as bright as possible; put a stained blood smear on the stage, add immersion oil, and use the 100x oil immersion objective lens; look through the microscope oculars, and focus the condenser up and down until the edge of the field is sharp; use the adjustment screws on the condenser to move the circle of light to the centre of the field if necessary. turn the light down, and open the iris diaphragm and the light source before use. Adjust the interpupillary distance. Adjust the dioptre. 4.4. Use of the microscope Be conversant with the parts of the microscope and their functioning for efficient use. Turn on the light source, and adjust the optimum light setting to ensure the correct level of brightness by turning or sliding the brightness adjustment knob at the base. Rotate the low power objective into position. Remove the eyepiece, look down the body tube and adjust the mirror and diaphragm setting so that light is reflected up the tube and a circle of evenly illuminated light is visible in the field of view. View the specimen with the 10x objective, then with the 40x and then with the 100x oil immersion objective. 2

Prevent damage to the 40x objectives Immediately remove any immersion oil that accidentally comes into contact with the 40x objective. Because the 40x lens is located next to the 100x lens and because it is also a long lens, it is easy for it to come into contact with immersion oil accidentally. The 40x objective is not sealed against oil penetration, and any immersion oil left in contact with this objective will penetrate the lens and be deposited on the inside of the lower lens. Only the manufacturer can repair, after dismantling the objective lens. Prevent damage to the 100x objective Lower the stage before removing a slide. After finishing a microscopic examination, immediately clean the immersion oil from the objective with lens paper and commercially prepared lens cleaner. If this is not done, the oil may thicken and harden over time and affect the optical performance of the lens. To protect the 100x objective lens, the objective should be rotated up when the microscope is not in use. 4.5. Daily maintenance Inspect the microscope for damage or malfunction. Record any damage or malfunction in the daily microscopy maintenance sheet. Clean the parts of the microscope with a clean cloth. Clean the objectives after each day s work. Ensure that immersion oil residues are removed. Do not clean any part of the microscope with xylene, which will damage the microscope and is toxic. Clean the objective lens with lens cleaning tissue only. Never clean lenses with alcohol, ordinary tissues, cleaning paper, toilet paper, cotton wool or hand towels, which will scratch the lens surface. Cover the microscope with a dust cover when not in use. Turn off the power at the end of the day, and unplug the microscope to protect it from a power surge. Do not leave lens ports uncovered; use the port cover or sealing tape. 4.6. Storage In warm humid climates, fungal growth is easily established on lenses and prisms. The microscope must be stored in dry conditions when not in use to prevent fungal growth on glass surfaces. For example, the microscope could be kept in a warm cupboard with a constant temperature and low humidity. Lenses and prism heads could be stored in airtight boxes containing desiccant (not containing cobalt chloride). 4.7. Repairs Site staff can replace a broken bulb or replace a blown fuse by strictly following the manufacturer s instructions. Other repairs must be performed by a qualified service engineer or technician. Do not exchange lenses and ports with those of other microscopes. Routine servicing, such as realignment of optics, replacement of lens and maintenance and lubrication of the stage, should be performed by a qualified service technician. Record all repairs on the microscope maintenance sheet. 3

5. PROCEDURE NOTES Precautions and safety The power source and connections to the microscope should be secure and stabilized and not expose staff to a risk for electrocution. The microscope and electrical connections should not be exposed to water. Care should be taken to prevent damage to the eyes from exposure to the high light-intensity halogen lamp. The microscope should be used ergonomically to prevent back and neck strain. Quality assurance The set-up and maintenance of the microscope should be inspected during routine supervisory visits. A register for maintaining laboratory equipment should also be inspected. A microscope maintenance chart similar to the table at the end of this SOP may be used. Causes of error unskilled repairs attempted on malfunctioning microscopes; removal of eyepieces, unless they are designed to slide in and out of the tube; and removal of eyepieces from sealed microscopes, exposing the internal optics to dust and fungi. 6. REFERENCES WHO. Universal access to malaria diagnostic testing. An operational manual. Geneva; 2011. WHO. Basic malaria microscopy. Part 1: Learner s guide. Geneva; 2010. 7. DOCUMENT HISTORY Date (mmm/yyyy) Version Comments Responsible person (First name, last name) Jan 2016 1 Reviewed and finalized by experts, edited and formatted Glenda Gonzales, Technical Officer, WPRO 4

EXAMPLE OF MICROSCOPE MAINTENANCE CHART MICROSCOPE ID: # Month/Year: Microscope type: Serial number: Manufacturer: Date first used: Please tick [ ] the activities. This chart should be filed away at the end of each month. Day of month Daily maintenance 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Check all optics for damage. Check coarse and fine adjustments. Clean surfaces of components. Clean the external surface. Remove oil. Replace bulbs as needed. Cover microscope after use. Technician s initials Comments.. QA check QA review Date: Audit 5