TotalPac X Double interlock Preaction system Electric / PneuLectric release

Similar documents
BERMAD Fire Protection

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Technical Data. Installation

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

BERMAD Fire Protection

Fire Pump Plan Review March 2010

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

Element D Services Plumbing

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Automatic Fire Sprinkler Submittal Requirements

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

Inspection and Testing of Water-Based Systems

Potter Electric Sprinkler Monitoring Training Manual

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

TECHNICAL DATA. Dry 122a. November 12, 2013

Cost Evaluation of Black Steel Pipe and Galvanized Pipe When Using a Nitrogen Generator

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Commercial Gas Furnace Upflow

Transformer Deluge Systems

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

I-768 FireLock NXT Dry Valve

FIVE YEAR CERTIFICATION REPORT

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

ESFR "PRE-PRIMED SINGLE INTERLOCKED PREACTION" COLD STORAGE SYSTEM MANUAL

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Oil and Coolant Circulating Heating System. Model - OCSM

NFPA31FuelOilPiping 1 Revised

Fire Sprinkler Monitoring PRODUCTS. Accessories Alarm Bells Waterflow Detectors Pressure Switches Supervisory Switches Explosion-Proof

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

ECOCIAT. Domestic hot water heat recovery unit

Wet System. Technical Manual for Operation, Maintenance, and Troubleshooting

MUELLER FALLING FILM CHILLERS

Industrial Generator Set Accessories

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Centro-Matic Automatic Lubrication Systems System Controls

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi CONTROL PANEL

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Advantium 2 Plus Alarm

KODAK VERSAMARK, INC.

HELIPORT FUEL/WATER SEPARATOR MODEL H-200

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Compressor Service & Maintenance Manual

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST

ETZGAR CONVEYOR COMPANY Controls Section v12.05

300 Series PA Pump and Cooler Assemblies

Pr o d u c t In f o r m at i o n V008.0

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

NEMA Enclosure Types

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Diesel Engine Driven Generators Page 1 of 6

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Condensing unit type EPSILON-ECHOS LE Technical information manual

Industrial Generator Set Accessories

MAC-120HE-01 Air-Cooled Chiller

Morrison Bros. Co. General Product Specifications

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

HEAVY DUTY STORAGE GAS

HYDROSTATIC TEST PUMPS

SWIMMING POOL HEAT PUMP

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

Power consumption (kw)

Light Duty Commercial Electric Water Heater

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Model: DC-A2IO Advanced HVAC Controller

Medical Air Systems: Scroll

G670 Intermittent Pilot Ignition Controls

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

SPP Pumps Inc. Atlanta

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Single Phase Soft Starter

Technical data. Danfoss DHP-A

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Hydraulic Control Solutions

Commercial Electric Water Heater

Pressure Relief and Regulating Valves

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Industrial Generator Set Accessories

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R

Wet alarm valves. Wet alarm valves. FM trim

FAIRBANKS NIJHUIS FIRE PUMPS.

Installation Manual CLIFC Fan & Coil Variable Speed

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

"EC" Series Electric Humidifier

Transcription:

DESCRIPTION This TOTALPAC X integrated fire protection system by FireFlex Systems Inc. consists of a preaction system trim totally preassembled, pre-wired and factory tested. All electrical and mechanical components of the system are contained in one single unit TOTALPAC X preaction systems are built around the Viking trim using deluge valves model E-3 for 1½" (40 mm) diameter and model E-1 for 2" (50 mm) diameter and up. Electric/Pneu-Lectric controlled preaction systems use pneumatic supervision of the automatic sprinkler system, and an electric detection system. The deluge valve release trim uses a normally closed electric solenoid valve controlled by an approved system control panel (supplied by others) with two initiating circuits configured for "cross-zoned" operation. One initiating circuit is connected to the electric detection system; the other to a "Low-Air" alarm switch. Both the electric detection system AND supervisory pressure must be relieved from the sprinkler system before the deluge valve will open and fill the sprinkler system with water. Activation of a releasing device alone or operation of a sprinkler alone will sound an alarm but will NOT cause the system to fill with water. All the valves are rated up to a maximum of 250 psi WWP (1724 kpa) max. and are available in the following diameters: 1½" (40 mm) 3" (80 mm) 6" (150 mm) 2" (50 mm) 4" (100 mm) Standard features NEMA 3 or NEMA 4 construction Factory assembled and tested under ISO-9001 standards Prewired to a terminal block Easy and compact installation Viking conventional trim rated at 250 psi (1724 kpa) Galvanized trim piping Serial number for easy reference Wide door for easy access Quarter turn door latches Lockable door to protect against tampering Lifting lugs provided for safe and easy handling Corrosion resistant paint finish Water supply and drain through the bottom center of the unit to avoid freeze-up potential Single drain connection 1 of 12 FM-076D-0-22C

Cabinet NEMA 3 Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure. NEMA 4 Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); and that will be undamaged by the external formation of ice on the enclosure. NEMA 3X Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure. NEMA 4X Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure. COMPARISON OF SPECIFIC NON-HAZARDOUS APPLICATIONS Type of enclosure Provide a degree of protection against the following environmental conditions 3 a 3X a 4 4X Incidental contact with enclosed equipment Rain, snow and sleet Hose down and splashing water Corrosive agents Ingress of solid foreign object (circulating or setting airborne dust, lint, fibers, and flyings) b Ingress of solid foreign objects (winblown dust, lint, fibers, and flyings) b a : these cabinet may be ventilated. b : these fibers and flyings are non hazardous materials and are not considered class III type ignitable fibers or combustible flyings. FM-076D-0-22C 2 of 12

Sequence of operation (see trim diagram) In a fire condition, operation of the detection system activates the first initiating circuit in the system control panel, causing an alarm to activate. When a sprinkler operates, air pressure escapes from the sprinkler piping. The air supervisory switch activates the second initiating circuit in system control panel. When BOTH initiating circuits have been activated, system control panel energizes solenoid valve (F1) open. Pressure is released from the priming chamber of the deluge valve (A1) to the open drain manifold faster than it is supplied through the restricted orifice (B3). The Deluge Valve clapper opens to allow water to flow into the system piping and alarm devices, causing the alarm pressure switch (C1) and optional water motor alarm (C2) to activate. When a sprinkler head opens, water will flow from the system. When the deluge valve operates, the sensing end of the PORV (B9) is pressurized, causing the PORV to open. When the PORV opens, it drains the priming water pressure to the priming chamber, preventing the deluge valve (A1) from resetting, even if the open releasing devices close. The deluge valve can only be reset after the system is taken out of service, and the outlet chamber of the deluge valve and associated trim piping is depressurized and drained. Systems hydraulic limitations WARNING The information contained herewith is for estimation and evaluation purposes only. Its use remains the responsibility of the designer. Designers should refer to the appropriate NFPA Standards and any other applicable codes for their final design. Also refer to FireFlex Systems Inc. appropriate user manuals and to manufacturer's data sheets for additional details. Systems limitations indicated below are nominal flow limitations. Piping Equivalent Lengths w/o System size Usage Range shut off valve (in.) (gpm) (m.) (ft.) 1½ 0 200 8.6 28.2 2 0 330 12.9 42.3 3 125-700 19.8 64.8 4 250 1200 27 88.8 6 750-2800 31.2 102.4 3 of 12 FM-076D-0-22C

Standard equipments Deluge valve The Viking Model deluge valve is a quick-opening, differential diaphragm, flood valve with one moving mechanism. The deluge valve is used to control water flow in deluge and preaction sprinkler systems. The valve is held closed by system water pressure trapped in the priming chamber, keeping the outlet chamber and system piping dry. In fire conditions, when the releasing system operates, pressure is released from the priming chamber. The deluge valve clapper opens to allow water to flow into the system piping. Preaction riser check valve The Viking spring loaded In-Line check valve is a general purpose rubber-faced check valve approved for use in fireservice systems. The Spring Loaded In-Line check valve is manufactured with a brass body, brass seat, and a rubberfaced clapper assembly. The Viking Easy Riser Swing check valve is a general purpose rubber-faced check valve approved for use in fire service systems. The valve is for use in preaction system risers. Water supply control valve The water inlet control valve is a supervised, indicating butterfly valve. Purpose of this vale is to manually shutoff the preaction system. Alarm pressure switch The alarm pressure switch monitors the water flow within the sprinkler piping. Should the Deluge Valve clapper opens to allow water to flow into the sprinkler piping. The alarm pressure switch will activate, indicating a water flow signal. POTTER PS10-1A Low air supervisory switch Solenoid valve The high pressure solenoid valve is a two-way type with one inlet and one outlet. It is a packless, internal pilot operated valve, suitable for use in releasing water pressure from the priming chamber of Viking deluge valves. The solenoid valve has floating diaphragm construction, which requires a minimum pressure drop across the valve to operate properly. The low pressure switches monitors the pressure within the sprinkler piping should a loss pressure of the air below 12PSI occurs. The pressure switch contacts transfer indicating supervisory signal. Should a loss pressure of the air below 10PSI occurs. The pressure switch contacts transfer indicating alarm signal. POTTER PS40-1A IN OUT FM-076D-0-22C 4 of 12

Optional equipment Shut-off valve & sight glass option The Shut-off Valve & Sight Glass Option is intended to be used for applications where testing of the system operation without filling the sprinkler piping network is desirable and where it is critical that all functions of the preaction system be tested under actual discharge conditions. Shut-off valve (D4) Sight glass Point flashlight here Heater option Heater option is recommended where ambient temperatures can drop below 40 F (4.5 C). The cabinet s electric heater temperature cut-out point is set at 50 F (10 C). The heater option is equipped with a low temperature sensor that will activate a supervisory signal when temperature drops below 40 ±5 F (4.5 ±3 C). Heater option can be ordered in two supply voltage settings: 120Vac-60Hz. 400Watts. 220Vac-50Hz. 400Watts. Warning: TOTALPAC X cabinet is rated to provide freeze protection down to a minimum temperature of 14 F (-10 C). Insulated enclosure (standard with heater option) Insulation is made on foam core 2 thick R13 and have a foilfaced sheathing board composed of a uniform closed cell polyisocyanurate foam core bonded on each side to a triminate foil facer. One side has a foil reflective facer and the other side has a non-reflective foil facer. Low temperature sensor (standard with heater option) The low temperature sensor will close the normally open contact when the temperature drops below 40 F (4,5 C. The sensor will automatically reset to its normal state when the temperature rises above 40 F (4,5 C). Light option Optional fluorescent enclosure light is available for all cabinet configurations. Remote door switch activates the light when the door is opened. Light option can be ordered in two supply voltage settings: 120Vac-60Hz. 220Vac-50Hz. 5 of 12 FM-076D-0-22C

Air supply Direct air compressor (Style A ) Used only for the sprinkler piping network of the preaction system. Air supply style "A" includes the air compressor mounted inside the TOTALPAC X cabinet with its supervisory trim and options. Compressors are of the tankless, oiless piston type and are factory piped to the sprinkler system riser, all within the TOTALPAC X cabinet. Air Pressure Maintenance Device (Style B ) Used only for the sprinkler piping network of the preaction system, when an external air supply is provided by others (tank mounted compressor, plant air or dry nitrogen cylinders) and piped to the air inlet port of the unit. Air supply style "B" provides an Air Pressure Maintenance Device (APMD) trim, factory mounted in the TOTALPAC X cabinet. Note: Direct air compressor is available only with NEMA 3, 3X cabinet. Compressors are available in four (4) sizes; 1/6HP 1/3HP 1/2HP 1HP Direct air, external compressor (Style D ) Mainly used with Preaction systems protecting refrigerated spaces and freezers, where a special dry external air supply unit is piped directly to the system riser inside the freezer itself, as shown in NFPA-13. Air supply Style "D" provides only an air supervisory and shut-off trim. Note: The external air supply must be restricted to insure that it cannot replace air as fast as it escapes when a releasing device or sprinkler operates. Air compressor selection Table: H.P. CFM @ 40 psi 120Vac System capacity (gallon) to Pump to 40 psi in 30 Minutes 220Vac System capacity (gallon) to Pump to 40 psi in 30 Minutes 1/6 1.33 110 90 1/3 2.61 215 170 1/2 4.06 335 270 1 7.40 610 400 Warning: When air supplies style "B" or "D" is selected, the air supply should be provided and installed by the sprinkler contractor OUTSIDE of the TOTALPAC X cabinet. It is NOT provided with the unit. Compressor Amp rating Compressor Size Amp. Rating at (HP) 120Vac 60Hz Amp. Rating at 220Vac 50Hz 1/6 6.6 A 3.3 A 1/3 6.6 A 3.3 A 1/2 8 A 4 A 1 12.4 A 6.2 A FM-076D-0-22C 6 of 12

Details & field wiring diagrams Cabinet with main components, shown without door FM-076Z-0-40A 7 of 12 FM-076D-0-22C

Trim diagram Components: A1 Deluge valve B1 Priming valve B2 Strainer B3 1/16" Restricted orifice B4 Spring loaded check valve B5 Alarm test valve B6 Flow test valve B7 Drip check valve B8 Drain check valve B9 Pressure operated relief valve (PORV) B10 Emergency release valve B11 Prime pressure water gauge & valve B12 Water supply pressure gauge & valve B13 Clapper check valve C1 C2 D1 D2 D3 F1 Alarm pressure switch Connection to water motor gong (strainer supplied by contractor) Water supply control valve Riser check valve Main drain valve N.C Solenoid Valve 24Vdc FM-076D-0-22C 8 of 12

Wiring diagram Waterflow Alarm switch Very low air Alarm switch Low air Sup'v switch Main valve Sup'v switch N.C. solenoid valve (See table below for details) Low temperature Sup'v switch (optional) Shut-off valve Sup'v switch (optional) Factory wired TBA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 TBB heater(optional) M NOTES: - ALL DEVICES ARE SHOWN IN THEIR NORMAL SUPERVISORY STATE. Compresseur(optionel) - DRY CONTACTS RATINGS: PRESS. SWITCHES: 2.0A. 30VDC / 10A. 125/250 VAC SUPV. SWITCHES: 0.5A. 125 VDC /.025A. 250 VAC / 10A 125/250VAC USE ONLY WITH POWER LIMITED CIRCUITS - USE END-OF-LINE DEVICES COMPATIBLE WITH THE RELEASE CONTROL PANEL USED (NOT INCLUDED). SOLENOID VALVE ELECTRICAL RATINGS Viking P/N Description Voltage Watts DC Amps 11591 N.C. 24 DVC 10 DC 416mA Light (optional) Factory wired Pressure Rating 300 psi (2068 kpa) Notes: 1. Solenoid Valve is UL Listed as Fire Protection Special System Water Control Release Service (UL 429A Product category VLTR). 2. Voltage Drop: For proper operation, make sure that voltage at the solenoid valve is at least 85% of nameplate rating. FM-076Z-0-30A 9 of 12 FM-076D-0-22C

Dimensions B FACE VIEW S R A = Water inlet diameter B = Sprinkler riser diameter C = Drain diameter Q G SIDE VIEW K DRAIN - SCH.40 GROOVED OUTLET C WATER INLET SCH.40 GROOVED A M E O F D FM-076Z-0-54B L H N X J BOTTOM VIEW M O TOP VIEW V W NN Dimensions are nominal and may vary ±¼". Size A B C D E F G H J K L M N NN O Q R S T U V W X Y 1.5" 2" 1.5" 2" 50" 24.5" 14.5" 74" 11.5" 11" 68" 25" 5.5" 25" 25" 11" 60" 4.75" 6" 9.5" 10.5" 4" 5" 9.5" 7.75" 2" 2" 2" 2" 50" 23" 12" 74" 12" 11" 68" 25" 5" 25" 25" 11" 60" 4.75" 6" 9.5" 10.5" 4" 5" 9.5" 8" 3" 4" 3" 2" 50" 23" 12.5" 74" 8.5" 11" 68" 25" 5.5" 28.5" 22" 11" 60" 4.75" 6" 9.5" 10.5" 4" 5" 9.5" 8.5" 4" 4" 4" 2" 50" 22.5" 12.5" 74" 8" 12" 68" 25" 5.5" 25.5" 25.5" 12" 60" 4.75" 6" 9.5" 10.5" 4" 5" 9.5" 9" 6" 6" 6" 2" 50" 21" 12" 74" 8" 12" 68" 25" 5" 25" 25" 12" 60" 4.75" 6" 9.5" 10.5" 4" 5" 9.5" 9" 4.5" 4.5" 9/16" DIAM. (4 HOLES) 4.5" 4.5" FLOOR ANCHORING TEMPLATE FM-076D-0-22C 10 of 12

11 of 12 FM-076D-0-22C

1935, Lionel-Bertrand Blvd. Boisbriand QC Canada J7H 1N8 Tel.: 450-437-3473 Fax: 450-437-1930 Toll Free: 866-347-3353 Email: info@fireflex.com Web: www.fireflex.com FM-076D-0-22C 12 of 12