LORAIN VPS DC Power System

Similar documents
LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Chassis, Power Supply, and Element Management

MPR-Systems. Mini Power Racks 1200 W W

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

MAJORSINE Power Inverter

MCR1900 Media Converter 19-Slot Chassis

Thyristor-controlled power supplies and battery chargers

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Model #: SMART2200CRMXL

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Infinity C DC to DC Power System

Infinity C DC to DC Power System

User s Manual Before using the inverter, you need to read and save the safety instructions.

8-Port PoE Network Switch

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

DSA E-Series E2600, DE1600, DE6600. en Storage System Site Preparation Guide

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

T1 Backhaul Connectivity Solution All Products :: Application Note

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

I STAR COMPUTER CO., LTD

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

Back-UPS Pro 1300/1500 Installation and Operation

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

HP Managed and Unmanaged Notebook Charging Carts Overview. Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Installation and Operation Back-UPS 1250, 1300, 1500

Re-defining the utility-scale inverter

Cisco Nexus 7000 Series Power Supply Modules

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Phase Modular Finally the benefits of Modular ups are for all

DCS Series 1 kw, 1.2 kw, & 3 kw

Uninterruptible Power Supply

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Power Distribution Considerations for Data Center Racks

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

DC Power Training Services Technical Courses

ST Series POWER SUPPLIES USER INSTRUCTIONS

Specification Requirements DBL 700MX and 1000MX Series UPS

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Power Supplies 3. SDN-P DIN Rail Series

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

LT-82 Stationary IR Transmitter

Internet Office UPS System Standby UPS for PCs, workstations and more

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

ABB central inverters PVS to 1000 kw

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

DC Electronic Loads 8500 series

Internet Office 500VA Tower Standby 120V UPS with USB port

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Power Feeding Equipment for Optical Submarine Cable Systems

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

4.0 UPS dedicated to ICT for unmatched energy savings

BC Pro UPS System Standby UPS System

Overview of Cisco 2600 Series Routers

Agilent 87421A/87422A Power Supply

Research RF Sputtering Packages

TIG INVERTER INSTRUCTION MANUAL

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

User Manual for CH-PFC76810

LOXONE 12 Channel Amplifier

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Provides one channel for Ethernet over existing

1.44 kw Programmable DC Power Supplies XLN Series

How To Test A Power Distribution Unit

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

Liebert GXT3 UPS 230V 700VA-3000VA

STRATO LED Drivers 70W, Single output

User Manual 1K/2K/3K Online UPS

Transcription:

LORAIN VPS 246000 DC Power for Business-Critical Continuity Key Features Modular Design simple to install and operate; allows users to grow system in cost-effective increments Single Point Adjustment no tools required to make settings and adjustments; the MCA controls up to 72 PCUs Remote Access options allow users to view, control and interact with all power systems in a network from a remote location Plug n Play add PCUs without adjustments and settings; no system interruption Front Accessible allows for easy installation, additions and maintenance High Density compact design takes up less floor space; houses four 150/180 amp 4,275 watt PCUs per rectifier shelf (3RU), system can be configured with up to three bays Optional Temperature Compensation provides automatic adjustment of PCU output voltage when battery temperature increases or decreases Safety Compliance NEBS Level 3 certified; UL listed to UL subject 1801 New 4,275 watt power conversion units provide 150 amps at 28.5VDC and 180 amps at 23.8VDC each with a constant power limiting feature. With four units per shelf, these rectifiers provide 600 to 720 amps in three rack units (5.25-in.) of space. Description The LORAIN VPS with 130 amp or 150/180 amp 4,275 watt power conversion units (PCUs) is a modular power system providing up to 6,000 amps of power for +24 volt systems. The basic components of the power system include the meter control alarm unit (MCA), rectifier shelves which house the PCUs and up to three modular distribution cabinets with rear copper bus inter-bay power connections, allowing the system to be expanded to either side of the main bay. The LORAIN VPS contains a powerful, microprocessor-based meter control alarm system, capable of monitoring and controlling up to 72 PCUs. The MCA provides a 16-character alphanumeric display, which can be activated at the touch of a keypad. Each rectifier shelf can accommodate up to four plug n play PCUs, which are controlled by the MCA. The shelves are modular, so additional shelves can be added as load requirements increase. The VPS distribution cabinet is modular by row and position. Four distinct distribution cabinet sizes are available to accommodate from one to four distribution panels. This allows the system to be configured in relay racks of various heights for installation in low-profile sites or atop batteries or other equipment to make more effective use of floor space. Several distribution panels are available offering different combinations of distribution positions, low voltage disconnect and battery disconnect options. +24VDC 2,000 amp LORAIN VPS with -48VDC Converters and LMS1000 Monitoring System PPB-MDCP-008 / 1206 Enterprise : 93

LORAIN VPS 246000 Application The LORAIN VPS is ideal for wireless applications such as cell sites, huts and large CUE sites. Additional Information For additional specification, engineering and installation information, specify spec. numbers 581125000 (power system), 588703800 (520 amp power shelf and 130 amp PCUs), 588704900 (600/720 amp shelf and 150/180 amp PCUs), 588248700 (40 amp converter frames and 10 amp modules), 588249400 (80 amp converter shelf and 10 amp modules). For ordering information, request SAG581125000, PD588703800, PD588704900. Distribution The LORAIN VPS includes a modular distribution product line that can be designed with one to three distribution cabinets sized to accommodate from one to four distribution panels each. Each panel is rated at 500 amps load. The maximum load per distribution cabinet is 2000 amps. The two, three and four-row distribution cabinets can be interconnected via copper inter-bay bus bars for a total system capacity of up to 6,000 amps with three bays. The system can also be expanded with additional bays that are not adjacent to each other via extended length communications cables and inter-bay power cabling. The distribution cabinet can be factory mounted in a relay rack or shipped loose for mounting in a customer supplied relay rack or cabinet rails. A wide variety of panels provide multiple combinations of distribution positions, low voltage disconnect and battery disconnect. Distribution cabinets are front accessible, modular in design and are initially configured in the factory. Circuit breakers and/or fuse modules plug into the multi-position distribution panels to provide for easy installation. Distribution device options include 1 to 250 amp plug-in circuit breakers, 3 to 100 amp TPS-style fuses,100 to 600 amp GJ/218-style circuit breakers and 70 to 600 amp TPH-style fuses. These devices can be configured for both load and battery disconnect. A GMT fuse module is also available. Modular Distribution Cabinets Copper Inter-bay Bus Bars (shown with cover removed for detail) 94 : Enterprise PPB-MDCP-008 / 1206

LORAIN VPS 246000 Monitoring/Control The MCA provides a single point of adjustment for such features as float voltage, test/equalize voltage,high voltage shutdown and current limit for all PCUs in the entire power system. The rugged, temperature hardened LED display allows users to view specific alarm conditions, system measurements and system settings. All measurements and adjustments can be performed locally via the alphanumeric display on the front of the MCA panel or remotely via optional software and hardware. The MCA provides local indicators and the ability to transmit various alarm conditions such as PCU failure, high voltage shutdown and AC failure. Remote and local communication is MCA available via an ethernet, modem, RS-232 or RS-485 interface. In addition, the LMS1000 monitoring product can be configured into this system (refer to 586505000 documentation for specifications). +24VDC 1,040 amp VPS with Battery Stand Battery Stand or Trays The LORAIN VPS can be configured with a NEBS Level 3 certified modular front access battery stand to provide an entire power plant in one bay. Available options include manual battery disconnect/protection, low voltage battery disconnect, battery current monitoring and battery recharge current limit (refer to 588810000 documentation for specifications). Rack mount battery trays are also available with optional battery disconnect circuit breakers. Converter Frame -48V, 40 amp Rectifier Shelf The power conversion units are housed in modular rectifier shelves each of which accommodates four PCUs. The rectifier shelves are 23" (58.42cm) wide by 10.5" (26.67cm) high for 130 amp PCUs or 5.25" (13.33cm) high for 150/180 amp 4,275 watt PCUs. System capacity can be easily expanded with additional shelves. AC connection options are available to provide an AC feed for each rectifier or for each pair of rectifiers. Twist-lock line cords can be provided for the individual PCU AC feed option (130 amp PCUs only). DC to DC Converters A modular DC to DC converter system provides up to 320 amps at -48VDC via high frequency switch mode converters rated at 10 amps each. A unique frame design mounts into a slot in the rectifier shelf and can accommodate four converter modules. Four of these frames can be configured in a system. The system can also accommodate two rack-mount shelves, each of which houses eight 10 amp modules. Distribution devices for the -48 volt output are located in the main distribution cabinet and are available in various quantities (refer to 588248700 documentation for specifications). PPB-MDCP-008 / 1206 Enterprise : 95

LORAIN VPS 246000 130 amp, +24 Power Conversion Unit 150/180 amp, 4,275 watt, +24 Power Conversion Unit Power Conversion Unit The modular, high frequency, switch-mode PCU is the foundation of the VPS platform. Plug n play technology allows for easy system configuration. System capacity can be increased by simply plugging an additional PCU into an existing rectifier shelf or a newly added expansion shelf no adjustments or setup are required. The LORAIN VPS can house up to 72 PCUs, which provide load power, battery float current and battery recharge current. The PCUs are monitored and controlled by the MCA. The PCUs allow the user to appropriately size a power plant to meet specific applications. 150/180 amp, 4,275 watt Power Conversion Unit Specifications Input Inrush Frequency Nominal 208/240 volts AC, single phase, 50/60 Hz, with a range of 176 to 264 volts. Extended range to 300 volt AC without damage. 23.0 amps@208vac, 19.8 amps@240vac, 27.24VDC, 4275 watts output 28.8 amps@176vac, 4275 watts output (worst case) Peak does not exceed 2 times the RMS input at full load, under any conditions of input voltage within the rated input voltage range 47-65 Hz Each PCU is individually wired; connections for individual AC input branch circuits are provided. If the AC input voltage decreases or increases beyond a non-adjustable predetermined value, the PCU power conversion circuitry inhibits, disabling PCU output. The PCU will recover automatically when the AC input voltage is re-established within specifications limits. Power Factor Typical power factor greater than or equal to 98% for any load greater than or equal to 50% of rated full load at nominal line. Meets IEC 1000 3 2. Operating Efficiency Typical operating efficiency 90% at full load Output Nominal +24 volts DC, positive ground, adjustable from +23.0 to +29.0VDC 150 to 180 amps per PCU, up to a total of 600 to 720 amps per shelf with four PCUs installed. Power 4,275 watts maximum. The PCU employs a constant power limiting feature which limits the maximum output power to 4,275 watts over the output voltage range of +23.8 to +29.0 VDC. Regulation Steady state output voltage remains within ±0.02% of any voltage within the range of +23.0 to +29.0 volts DC for any combination of input voltage, input frequency and load from no load to full load Filtering On or off battery Voice Band Noise Less than 32 dbrnc Wide Band Noise Does not exceed 250 mv peak-to-peak, or 30 mv rms Psophometric Noise Does not exceed 1 mv 96 : Enterprise PPB-MDCP-008 / 1206

LORAIN VPS 246000 150/180 amp, 4,275 watt Power Conversion Unit Specifications (continued) Limiting Maximum output current of each PCU can be set from 15 to 180 amps. High Shutdown If PCU output voltage exceeds an adjustable preset value, the PCU shuts down. After approximately three seconds, the PCU automatically restarts. Status/Alarm Indicators and Monitoring Extensive alarming and status indicators such as AC on/off, fan fail, PCU failure and open sense are displayed on the 16-character numerical display of the MCA and on the PCUs in the shelf. Environmental Operating Temperature -40 C to +50 C (-40 F to +122 F); -40 C to +65 C (-40 F to +149 F) derate linearly to 3,200 watts output at 65 C (149 F) Storage Temperature -40 C to +85 C (-40 F to +185 F) Humidity 0% to 95% relative humidity, non-condensing Altitude The maximum operating ambient temperature should be derated by 10 C (18 F) at an elevation of 10,000 feet ( 3,048m) above sea level. For elevations between 3,000 feet (914m) and 10,000 feet (3,048m), derate the maximum operating ambient temperature linearly. Ventilation Fan-cooled front to rear EMI/RFI Suppression Conforms to FCC rules Part 15, Subpart B, Class B and EN55022 Class B, radiated and conducted Audible Noise 2 feet from any vertical surface; does not exceed 77dBA, 65dBA with low fan speed selected. Physical Characteristics Mounting Plug-in installation Dimensions (H x W x D) 5.10" (12.95cm) x 5.13" (13.02cm) x 14.5" (36.83cm) Weight 17 lbs. (7.73 kg) Safety Compliance UL recognized (UL 1950), CSA 22.2, No.950, CE 130 amp Power Conversion Unit Specifications Input Inrush Frequency Power Factor Operating Efficiency Nominal 208/240 volts AC, single phase, 50/60 Hz, with a range of 176 to 264 volts. Extended range to 290 volt AC 19.9 amps@208vac, 17.1 amps@240vac, 27.24VDC, 130 amps output 24.8 amps@176vac, 28.5VDC, 136 amps output (worst case) Peak does not exceed 2 times the RMS input at full load, under any conditions of input voltage within the rated input voltage range 45-70 Hz Each PCU is individually wired and connections for individual AC input branch circuits are provided. If the AC input voltage decreases or increases beyond a non-adjustable predetermined value, the PCU power conversion circuitry inhibits, disabling PCU output. The PCU will recover automatically when the AC input voltage is re-established within specifications limits. Typical power factor greater than or equal to 98% for any load greater than or equal to 50% of rated full load at nominal line. Meets IEC 1000 3 2. Typical operating efficiency 89% at full load PPB-MDCP-008 / 1206 Enterprise : 97

LORAIN VPS 246000 130 amp Power Conversion Unit Specifications (continued) Output Nominal +24 volts DC, negative ground, adjustable from 23.0 to 28.5 volts DC 130 amps per PCU, up to a total of 520 amps per shelf with four PCUs installed. Regulation Steady state output voltage remains within ±0.02% of any voltage within the range of 23.0 to 28.5 volts DC for an combination of input voltage, input frequency and load from no load to full load Filtering On or off battery Voice Band Noise Less than 32 dbrnc Wide Band Noise Does not exceed 250 mv peak-to-peak, or 25 mv rms Psophometric Noise Does not exceed 1 mv Limiting Maximum output current of each PCU can be set from 10% to 105% of full load current. High Shutdown If PCU output voltage exceeds an adjustable preset value, the PCU shuts down. After approximately three seconds, the PCU automatically restarts. Status/Alarm Indicators and Monitoring Environmental Operating Temperature Storage Temperature Humidity Altitude Ventilation EMI/RFI Suppression Audible Noise Physical Characteristics Mounting Dimensions (H x W x D) Weight Safety Compliance Extensive alarming and status indicators such as AC on/off, fan fail, PCU failure and open sense are displayed on the 16-character numerical display of the MCA and on the PCUs in the shelf. -40 C to +50 C (-40 F to +122 F);-40 C to +65 C (-40 F to +149 F) at 110 amps output -40 C to +85 C (-40 F to +185 F) 0% to 95% relative humidity, non-condensing The maximum operating ambient temperature should be derated by 10 C (18 F) at an elevation of 10,000' (3,048m) above sea level. For elevations between 3,000' (914m) and 10,000' (3,048m), derate the maximum operating ambient temperature linearly. Fan-cooled front to rear Conforms to FCC rules Part 15, Subpart B, Class A, with an option for FCC and CISPR22 Class B emission ratings. 3' from any vertical surface does not exceed 65dBA; 55dBA with low fan speed selected. Plug-in installation 9.88" (25.08cm) x 5.13" (13.02cm) x 14.5" (36.83cm) 18 lbs. (8.16 kgs) UL recognized (UL 1950), CSA 22.2, No.950, CE Emerson Network Power. The global leader in enabling businesscritical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge 2007 Emerson Network Power Energy Systems, North America, Inc. All rights reserved. Emerson Network Power Energy Systems 1122 F St. Lorain, OH 44052 Toll Free: 800-800-1280 (USA and Canada) Telephone: 440-246-6999 Fax: 440-246-4876 Web: EmersonNetworkPower.com/EnergySystems This publication is issued to provide outline information only which (unless agreed by Emerson Network Power Energy Systems, North America, Inc. in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or services concerned. Emerson Network Power Energy Systems, North America, Inc. reserves the right to alter without notice the specification, design or conditions of supply of any product or service. The Emerson logo is a trademark and a service mark of Emerson Electric Co. Emerson Network Power is a division of Emerson Electric Co. Vortex, and LORAIN are trademarks of Emerson Network Power Energy Systems, North America, Inc. 98 : Enterprise Printed in USA PPB-MDCP-008 / 1206

LORAIN VPS 486000 DC Power for Business-Critical Continuity Key Features Modular Design simple to install and operate; allows users to grow system in cost-effective increments Single Point Adjustment no tools required to make settings and adjustments; the MCA controls up to 72 PCUs Remote Access options allow users to view, control and interact with all power systems in a network from a remote location Plug n Play add PCUs without adjustments and settings; no system interruption Front Accessible allows for easy installation, additions and maintenance High Density compact design takes up less floor space; houses four 85/105 amp 5,000 watt PCUs per rectifier shelf (3RU), system can be configured with up to three bays Optional Temperature Compensation provides automatic adjustment of PCU output voltage when battery temperature increases or decreases Safety Compliance NEBS Level 3 certified; UL listed to UL subject 1801 New 5,000 watt power conversion units provide 85 amps at 58.0VDC and 105 amps at 48.0VDC each with a constant power limiting feature. With four units per shelf, these rectifiers provide 340 to 420 amps in three rack units (5.25-in.) of space. Description The LORAIN VPS with 65 amp or 85/105 amp 5,000 watt power conversion units (PCUs) is a modular power system providing up to 6,000 amps of power for -48 volt systems. The basic components of the power system include the meter control alarm unit (MCA), rectifier shelves which house the PCUs and up to three modular distribution cabinets with rear copper bus inter-bay power connections, allowing the system to be expanded to either side of the main bay. The LORAIN VPS contains a powerful, microprocessor-based meter control alarm system, capable of monitoring and controlling up to 72 PCUs. The MCA provides a 16-character alphanumeric display, which can be activated at the touch of a keypad. Each rectifier shelf can accommodate up to four plug n play PCUs, which are controlled by the MCA. The shelves are modular, so additional shelves can be added as load requirements increase. The VPS distribution cabinet is modular by row and position. Four distinct distribution cabinet sizes are available to accommodate from one to four distribution panels. This allows the system to be configured in relay racks of various heights for installation in low-profile sites or atop batteries or other equipment to make more effective use of floor space. Several distribution panels are available offering different combinations of distribution positions, low voltage disconnect and battery disconnect options. -48VDC 1,600 amp LORAIN VPS with +24VDC Converters and LMS1000 Monitoring System PPB-MDCP-003 / 1206 Enterprise : 99

LORAIN VPS 486000 Application The LORAIN VPS is ideal for wireline and wireless applications such as switch sites, co-location, huts and large CUE sites. Additional Information For additional specification, engineering and installation information, specify spec. numbers 582125000 (power system), 588703600 (260 amp power shelf and 65 amp PCUs), 588704800 (340/420 amp shelf and 85/105 amp PCUs), 588249600 (80 amp converter frame and 20 amp modules), 588249700 (160 amp converter shelf and 20 amp modules), 588250100 (40 amp converter frame and 20 amp modules). For ordering information, request SAG582125000, PD588703600, PD588704800. Distribution The LORAIN VPS includes a modular distribution product line that can be designed with one to three distribution cabinets sized to accommodate from one to four distribution panels each. Each panel is rated at 500 amps load. The maximum load per distribution cabinet is 2000 amps. The two, three and four-row distribution cabinets can be interconnected via copper inter-bay bus bars for a total system capacity of up to 6,000 amps with three bays. The system can also be expanded with additional bays that are not adjacent to each other via extended length communications cables and inter-bay power cabling. The distribution cabinet can be factory mounted in a relay rack or shipped loose for mounting in a customer supplied relay rack or cabinet rails. A wide variety of panels provide multiple combinations of distribution positions, low voltage disconnect and battery disconnect. Distribution cabinets are front accessible, modular in design and are initially configured in the factory. Circuit breakers and/or fuse modules plug into the multiposition distribution panels to provide for easy installation. Distribution device options include 1 to 250 amp plug-in circuit breakers, 3 to 100 amp TPS-style fuses,100 to 600 amp GJ/218-style circuit breakers and 70 to 600 amp TPH-style fuses. These devices can be configured for both load and battery disconnect. A GMT fuse module is also available. Modular Distribution Cabinets Copper Inter-bay Bus Bars (shown with cover removed for detail) 100 : Enterprise PPB-MDCP-003 / 1206

LORAIN VPS 486000 Monitoring/Control The MCA provides a single point of adjustment for such features as float voltage, test/equalize voltage,high voltage shutdown and current limit for all PCUs in the entire power system. The rugged, temperature hardened LED display allows users to view specific alarm conditions, system measurements and system settings. All measurements and adjustments can be performed locally via the alphanumeric display on the front of the MCA panel or remotely via optional software and hardware. The MCA provides local indicators and the ability to transmit various alarm conditions such as PCU failure, high voltage shutdown and AC failure. Remote and local communication is available via an Ethernet, modem, RS-232 or MCA RS-485 interface. In addition, the LMS1000 monitoring product can be configured into this system (refer to 586505000 documentation for specifications). Battery Stand or Trays The LORAIN VPS can be configured with a NEBS Level 3 certified modular front access battery stand to provide an entire power plant in one bay. Available options include manual battery disconnect/ protection, low voltage battery disconnect, battery current monitoring and battery recharge current limit (refer to 588820000 documentation for specifications). Rack mount battery trays are also available with optional battery disconnect circuit breakers. -48VDC 520 amp VPS with Battery Stand -48VDC 500 amp VPS with Battery Trays DC to DC Converters A modular DC to DC converter system provides up to 320 amps at +24VDC via high frequency switch mode converters rated at 20 amps each. A unique frame design mounts into a slot in the rectifier shelf and +24V, 80 amp Converter Frame can accommodate four converter modules (260 amp rectifier shelf) or two converter modules (340/420 amp rectifier shelf). The system can also accommodate up to two rack-mount shelves, each of which houses eight 20 amp modules. Distribution devices for the +24 volt output are located in the main distribution cabinet and are available in various quantities. PPB-MDCP-003 / 1206 Enterprise : 101

LORAIN VPS 486000 65 amp, -48 Power Conversion Unit Power Conversion Unit The modular, high frequency, switch-mode PCU is the foundation of the LORAIN VPS platform. Plug n play technology allows for easy system configuration. System capacity can be increased by simply plugging an additional PCU into an existing rectifier shelf or a newly added expansion shelf no adjustments or setup are required. The LORAIN VPS can house up to 72 PCUs, which provide load power, battery float current and battery recharge current. The PCUs are monitored and controlled by the MCA. The PCUs allow the user to appropriately size a power plant to meet specific applications. Rectifier Shelf The power conversion units are housed in modular rectifier shelves each of which accommodates four PCUs. The rectifier shelves are 23" (58.42cm) wide by 10.5" (26.67cm) high for 65 amp PCUs or 5.25" (13.33cm) high for 85/105 amp 5,000 watt PCUs. System capacity can be easily expanded with additional shelves. AC connection options are available to provide an AC feed for each rectifier or for each pair of rectifiers. Twist-lock line cords can be provided for the individual PCU AC feed option (65 amp PCUs only). 85/105 amp, 5000 watt, -48 Power Conversion Unit 85/105 amp, 5000 watt, Power Conversion Unit Specifications Input Inrush Frequency Power Factor Operating Efficiency Output Power Regulation Filtering Voice Band Noise Wide Band Noise Psophometric Noise Nominal 208/240 volts AC, single phase, 50/60 Hz, with a range of 176 to 264 volts. Extended range to 300 volt AC without damage. 26.9 amps@208vac, 23.3 amps@240vac, 54.48VDC, 5000 watts output 33.0 amps @176VAC, 5000 watts output (worst case) Peak does not exceed 2 times the RMS input at full load, under any conditions of input voltage within the rated input voltage range. 47-65 Hz Each PCU is individually wired; connections for individual AC input branch circuits are provided. If the AC input voltage decreases or increases beyond a non-adjustable predetermined value, the PCU power conversion circuitry inhibits, disabling PCU output. The PCU will recover automatically when the AC input voltage is reestablished within specifications limits. Typical power factor greater than or equal to 98% for any load greater than or equal to 50% of rated full load at nominal line. Meets IEC 1000 3 2. Typical operating efficiency 91% at full load Nominal -48 volts DC, positive ground, adjustable from -44.0 to -58.0 volts DC 85 to 105 amps per PCU, up to a total of 340 to 420 amps per shelf with four PCUs installed. 5,000 watts maximum. The PCU employs a constant power limiting feature which limits the maximum output power to 5,000 watts over the output voltage range of -47.6 to -58.0VDC. Steady state output voltage remains within ±0.02% of any voltage within the range of 44.0 to 58.0 volts DC for any combination of input voltage, input frequency and load from no load to full load On or off battery Less than 32 dbrnc Does not exceed 250 mv peak-to-peak, or 30 mv rms Does not exceed 1 mv 102 : Enterprise PPB-MDCP-003 / 1206

LORAIN VPS 486000 85/105 amp, 5000 watt, Power Conversion Unit Specifications (continued) Limiting High Shutdown Monitoring Status/Alarm Indicators Environmental Operating Temperature Storage Temperature Humidity Altitude Ventilation EMI/RFI Suppression Audible Noise Physical Characteristics Mounting Dimensions (H x W x D) Weight Safety Compliance Maximum output current of each PCU can be set from 8.5 to 105 amps. If PCU output voltage exceeds an adjustable preset value, the PCU shuts down. After approximately three seconds, the PCU automatically restarts. Extensive alarming and status indicators such as AC on/off, fan fail, PCU failure and open sense are displayed on the 16-character numerical display of the MCA and on the PCUs in the shelf. -40 C to +50 C (-40 F to +122 F); -40 C to +65 C (-40 F to +149 F) derate linearly to 4,000 watts output at 65 C (149 F) -40 C to +85 C (-40 F to +185 F) 0% to 95% relative humidity, non-condensing The maximum operating ambient temperature should be derated by 10 C (18 F) at an elevation of 10,000 feet (3,048m) above sea level. For elevations between 3,000 feet (914m) and 10,000 feet (3,048m), derate the maximum operating ambient temperature linearly. Fan-cooled front to rear Conforms to FCC rules Part 15, Subpart B, Class B and EN55022 Class B, radiated and conducted 2 feet from any vertical surface; does not exceed 77dBA, 65dBA with low fan speed selected. Plug-in installation 5.10" (12.95cm) x 5.13" (13.02cm) x 14.5" (36.83cm) 17 lbs. (7.73 kg) UL recognized (UL 1950), CSA 22.2, No.950, CE 65 amp Power Conversion Unit Specifications Input Inrush Frequency Nominal 208/240 volts AC, single phase, 50/60 Hz, with a range of 176 to 264 volts. Extended range to 290 volt AC without damage. 19.3 amps@208vac, 16.6 amps@240vac, 54.48VDC, 65 amps output 25.1 amps@176vac, 57VDC, 69 amps output (worst case) Peak does not exceed 2 times the RMS input at full load, under any conditions of input voltage within the rated input voltage range 45-70 Hz Each PCU is individually wired; connections for individual AC input branch circuits are provided. If the AC input voltage decreases or increases beyond a non-adjustable predetermined value, the PCU power conversion circuitry inhibits, disabling PCU output. The PCU will recover automatically when the AC input voltage is re-established within specifications limits. Power Factor Typical power factor greater than or equal to 98% for any load greater than or equal to 50% of rated full load at nominal line. Meets IEC 1000 3 2. Operating Efficiency Typical operating efficiency 89% at full load PPB-MDCP-003 / 1206 Enterprise : 103

LORAIN VPS 486000 65 amp Power Conversion Unit Specifications (continued) Output Regulation Filtering Voice Band Noise Wide Band Noise Psophometric Noise Limiting High Shutdown Monitoring Status/Alarm Indicators Environmental Operating Temperature Storage Temperature Humidity Altitude Ventilation EMI/RFI Suppression Audible Noise Physical Characteristics Mounting Dimensions (H x W x D) Weight Safety Compliance Nominal -48 volts DC, positive ground, adjustable from -44.0 to -57.0 volts DC 65 amps per PCU, up to a total of 260 amps per shelf with four PCUs installed. Steady state output voltage remains within ±0.02% of any voltage within the range of 44.0 to 57.0 volts DC for any combination of input voltage, input frequency and load from no load to full load On or off battery Less than 32 dbrnc Does not exceed 250 mv peak-to-peak,or 25 mv rms Does not exceed 1 mv Maximum output current of each PCU can be set from 10% to 105% of full load current. If PCU output voltage exceeds an adjustable preset value, the PCU shuts down. After approximately three seconds, the PCU automatically restarts. Extensive alarming and status indicators such as AC on/off, fan fail, PCU failure and open sense are displayed on the 16-character numerical display of the MCA and on the PCUs in the shelf. -40 C to +50 C (-40 F to +122 F); -40 C to +65 C (-40 F to +149 F) at 55 amps output -40 C to +85 C (-40 F to +185 F) 0% to 95% relative humidity, non-condensing The maximum operating ambient temperature should be derated by 10 C (18 F) at an elevation of 10,000 feet (3,048m) above sea level. For elevations between 3,000 feet (914m) and 10,000 feet (3,048m), derate the maximum operating ambient temperature linearly. Fan-cooled front to rear Conforms to FCC rules Part 15, Subpart B, Class A, with an option for FCC and CISPR22 Class B emission ratings. 3 feet from any vertical surface; does not exceed 65dBA, 55dBA with low fan speed selected. Plug-in installation 9.88" (25.08cm) x 5.13" (13.02cm) x 14.5" (36.83cm) 18 lbs. (8.16kgs) UL recognized (UL 1950), CSA 22.2, No.950, CE Emerson Network Power. The global leader in enabling businesscritical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge 2007 Emerson Network Power Energy Systems, North America, Inc. All rights reserved. Emerson Network Power Energy Systems 1122 F St. Lorain, OH 44052 Toll Free: 800-800-1280 (USA and Canada) Telephone: 440-246-6999 Fax: 440-246-4876 Web: EmersonNetworkPower.com/EnergySystems This publication is issued to provide outline information only which (unless agreed by Emerson Network Power Energy Systems, North America, Inc. in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or services concerned. Emerson Network Power Energy Systems, North America, Inc. reserves the right to alter without notice the specification, design or conditions of supply of any product or service. The Emerson logo is a trademark and a service mark of Emerson Electric Co. Emerson Network Power is a division of Emerson Electric Co. Vortex, and LORAIN are trademarks of Emerson Network Power Energy Systems, North America, Inc. 104 : Enterprise Printed in USA PPB-MDCP-003 / 1206