Aruba S3500/Cisco Catalyst Interoperability Test Results. September 2011

Similar documents
Aruba Mobility Access Switch and Arista 7050S INTEROPERABILITY TEST RESULTS:

Juniper / Cisco Interoperability Tests. August 2014

Juniper Networks EX Series/ Cisco Catalyst Interoperability Test Results. May 1, 2009

Juniper Networks EX Series Ethernet Switches/ Cisco VoIP Interoperability Test Results. September 25, 2009

FlexNetwork Architecture Delivers Higher Speed, Lower Downtime With HP IRF Technology. August 2011

AT-S60 Version Management Software for the AT-8400 Series Switch. Software Release Notes

Abstract. Avaya Solution & Interoperability Test Lab

VLANs. Application Note

HARTING Ha-VIS Management Software

Abstract. MEP; Reviewed: GAK 10/17/2005. Solution & Interoperability Test Lab Application Notes 2005 Avaya Inc. All Rights Reserved.

What is VLAN Routing?

Overview of Routing between Virtual LANs

How To Configure Voice Vlan On An Ip Phone

Five Pillars: Assessing the Cisco Catalyst 4948E for Data Center Service

Abstract. Avaya Solution & Interoperability Test Lab

Objectives. The Role of Redundancy in a Switched Network. Layer 2 Loops. Broadcast Storms. More problems with Layer 2 loops

Cisco EtherSwitch Network Modules

CHAPTER 10 LAN REDUNDANCY. Scaling Networks

Management Software. Web Browser User s Guide AT-S106. For the AT-GS950/48 Gigabit Ethernet Smart Switch. Version Rev.

Abstract. Avaya Solution & Interoperability Test Lab

Configure IOS Catalyst Switches to Connect Cisco IP Phones Configuration Example

Interoperability between Avaya IP phones and ProCurve switches

Switching in an Enterprise Network

Dell PowerVault MD Series Storage Arrays: IP SAN Best Practices

BLADE PVST+ Spanning Tree and Interoperability with Cisco

VLAN 802.1Q. 1. VLAN Overview. 1. VLAN Overview. 2. VLAN Trunk. 3. Why use VLANs? 4. LAN to LAN communication. 5. Management port

Abstract. Avaya Solution & Interoperability Test Lab

Data Networking and Architecture. Delegates should have some basic knowledge of Internet Protocol and Data Networking principles.

48 GE PoE-Plus + 2 GE SFP L2 Managed Switch, 375W

Abstract. Avaya Solution & Interoperability Test Lab

Chapter 7 Lab 7-1, Configuring Switches for IP Telephony Support

Interoperability between Cisco Unified IP 7900 Series phones and ProCurve switches

Lab Testing Summary Report

Course Contents CCNP (CISco certified network professional)

EVOLVING ENTERPRISE NETWORKS WITH SPB-M APPLICATION NOTE

How To Switch In Sonicos Enhanced (Sonicwall) On A 2400Mmi 2400Mm2 (Solarwall Nametra) (Soulwall 2400Mm1) (Network) (

Virtual PortChannels: Building Networks without Spanning Tree Protocol

Datasheet. Managed Gigabit Fiber Switch. Model: ES-12F. Non-Blocking Throughput Switching. High Performance and Low Latency

Note: This case study utilizes Packet Tracer. Please see the Chapter 5 Packet Tracer file located in Supplemental Materials.

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: ES W, ES W, ES W, ES W

VXLAN: Scaling Data Center Capacity. White Paper

MS Series: VolP Deployment Guide

CCNP SWITCH: Implementing High Availability and Redundancy in a Campus Network

IP SAN BEST PRACTICES

Abstract. Avaya Solution & Interoperability Test Lab

HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios

VMware ESX Server Q VLAN Solutions W H I T E P A P E R

Voice Over IP. MultiFlow IP Phone # 3071 Subnet # Subnet Mask IP address Telephone.

A Guide to Simple IP Camera Deployment Using ZyXEL Bandwidth Solutions

Efficient Video Distribution Networks with.multicast: IGMP Querier and PIM-DM

EX 3500 ETHERNET SWITCH

Datasheet. Managed Gigabit Switches with SFP. Models: ES-24-Lite, ES-48-Lite. Non-Blocking Throughput Switching Performance

CCT vs. CCENT Skill Set Comparison

DCS CT-POE fully loaded AT PoE Switch Datasheet

Objectives. Explain the Role of Redundancy in a Converged Switched Network. Explain the Role of Redundancy in a Converged Switched Network

Use MAC-Forced Forwarding with DHCP Snooping to Create Enhanced Private VLANs

Network Discovery Protocol LLDP and LLDP- MED

CCNA R&S: Introduction to Networks. Chapter 5: Ethernet

SonicOS Enhanced Release Notes

ALL8894WMP. User s Manual. 8-Port 10/100/1000Mbps with 4-port PoE. Web Management Switch

ADVANCED NETWORK CONFIGURATION GUIDE

hp ProLiant network adapter teaming

Can PowerConnect Switches Be Used in IP Multicast Networks?

STATE OF THE ART OF DATA CENTRE NETWORK TECHNOLOGIES CASE: COMPARISON BETWEEN ETHERNET FABRIC SOLUTIONS

TP-LINK. 24-Port Gigabit Smart PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG2424P.

ForeScout CounterACT. Device Host and Detection Methods. Technology Brief

RESILIENT NETWORK DESIGN

Enabling Multiple Wireless Networks on RV320 VPN Router, WAP321 Wireless-N Access Point, and Sx300 Series Switches

Interconnecting Cisco Networking Devices Part 2

EX Series Technical Details

> Technical Configuration Guide for Microsoft Network Load Balancing. Ethernet Switch and Ethernet Routing Switch Engineering

Gigabit Ethernet Web Smart 8-Port Switch 2 Combo SFP Open Slot

802.1X Authentication, Link Layer Discovery Protocol (LLDP), and Avaya IP Telephones

Network Discovery Protocol LLDP and LLDP- MED

Management Software. User s Guide AT-S84. For the AT-9000/24 Layer 2 Gigabit Ethernet Switch. Version Rev. B

Fiber Channel Over Ethernet (FCoE)

Abstract. Avaya Solution & Interoperability Test Lab

Cisco Networking Professional-6Months Project Based Training

Rohde & Schwarz R&S SITLine ETH VLAN Encryption Device Functionality & Performance Tests

Configuring EtherChannel and 802.1Q Trunking Between Catalyst L2 Fixed Configuration Switches and Catalyst Switches Running CatOS

Chapter 3. Enterprise Campus Network Design

16-PORT POWER OVER ETHERNET WEB SMART SWITCH

Configuring LLDP, LLDP-MED, and Location Service

Configuring LACP (802.3ad) Between a Catalyst 6500/6000 and a Catalyst 4500/4000

TP-LINK. 24-Port Gigabit L2 Managed PoE Switch with 4 Combo SFP Slots. Overview. Datasheet TL-SG3424P.

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: ES-8-150W, ES W, ES W, ES W, ES W, ES W

Example: Configuring VoIP on an EX Series Switch Without Including 802.1X Authentication

Switching Basics and Intermediate Routing CCNA 3 Labs and Study Guide Allan Johnson

: Interconnecting Cisco Networking Devices Part 1 v2.0 (ICND1)

Layer 3 Network + Dedicated Internet Connectivity

Cisco Small Business Managed Switches

Cisco Which VPN Solution is Right for You?

Interoperability between Mitel IP Phones and ProCurve Switches

Exhibit n.2: The layers of a hierarchical network

Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance

Lab Testing Summary Report

TP-LINK. 24-Port 10/100Mbps + 4-Port Gigabit L2 Managed Switch. Overview. Datasheet TL-SL

Chapter 2 Lab 2-2, Configuring EtherChannel Instructor Version

ProSafe Plus Switch Utility

IP SAN Best Practices

Transcription:

Aruba S3500/Cisco Catalyst Interoperability Test Results September 2011

Page2 Executive Summary Aruba Networks commissioned Network Test to assess interoperability between its S3500 Mobility Access Switch and switches from Cisco Systems. Working with a test bed that included core-, distribution-, and access-layer switches, Network Test validated the interoperability of 13 data, voice, and security protocols commonly used in enterprise networks. The Aruba and Cisco devices exchanged traffic using every protocol tested. In other words, testing demonstrated complete interoperability. The following table summarizes the results of interoperability tests. Aruba Networks / Cisco Systems Protocol Interoperability VLAN trunking Aruba S3500 Mobility Access Switch Diff-serv codepoint remarking Aruba S3500 Mobility Access Switch Cisco Catalyst 3750 Cisco Catalyst 3750 Cisco Catalyst 4506 Cisco Catalyst 4506 Cisco Catalyst 6506 Cisco Catalyst 6506 Multiple spanning tree protocol (MSTP) Link aggregation Cisco Catalyst 3750 Cisco Catalyst 3750 Cisco Catalyst 4506 Cisco Catalyst 4506 Cisco Catalyst 6506 Cisco Catalyst 6506 MSTP (Aruba) / PVST+ (Cisco on VLAN 1) VoIP using LLDP-MED Cisco Catalyst 3750 Cisco Catalyst 3750 Cisco Catalyst 4506 Cisco Catalyst 4506 Cisco Catalyst 6506 Cisco Catalyst 6506 MSTP (Aruba) / Rapid PVST+ (Cisco on VLAN 1) 802.1X authentication (S3500 as authenticator) Cisco Catalyst 3750 Cisco Catalyst 3750 Cisco Catalyst 4506 Cisco Catalyst 4506 Cisco Catalyst 6506 Cisco Catalyst 6506 Aruba Hot Standby Link (HSL) Tunneled node with role-based authentication Cisco Catalyst 3750 Cisco Catalyst 3750 Cisco Catalyst 4506 Cisco Catalyst 4506 Cisco Catalyst 6506 Cisco Catalyst 6506 IGMP snooping MAC authentication Cisco Catalyst 3750 Cisco 7942G phone Cisco Catalyst 4506 Aruba AP-105 access point Cisco Catalyst 6506 Aruba AP-135 access point Power over Ethernet (PoE)/PoE+ Cisco 7942G IP phone Aruba AP-135 access point Aruba AP-135 access point

Page3 Methodology and Results Figure 1 below illustrates the test bed used to validate interoperability for most tests. The interoperability test bed used a three-tier design commonly found in enterprise campus networks, with separate devices at the core (Catalyst 6506), distribution (Catalyst 4506), and access layers (Cisco Catalyst 3750 and Aruba S3500 Mobility Access Switch). A Spirent TestCenter traffic generator/analyzer emulated clients and servers, and externally verified interoperability of the various protocols. Except where otherwise noted, tests involved connections between each layer of the network, validating interoperability of each protocol using every device on the test bed. Aruba Networks supplied all Aruba and Cisco equipment for this project. Figure 1: The Aruba-Cisco Interoperability Test Bed

Page4 VLAN Trunking Network Test evaluated IEEE 802.1Q VLAN trunking interoperability in three ways: forwarding of allowed tagged traffic; forwarding of allowed untagged (native) traffic; and blocking of disallowed untagged traffic. Engineers configured eight VLANs on each switch, and configured trunk ports between switches to allow traffic from six VLANs as tagged frames and a seventh VLAN as untagged frames. To determine whether switches would correctly block disallowed traffic, engineers did not include the eighth VLAN ID in the list of VLANs allowed across trunk ports. Spirent TestCenter then offered untagged traffic in all VLANs to each Aruba and Cisco switch, destined for all other switches. In all cases, traffic counters on the Spirent test instrument verified that Aruba and Cisco switches correctly forwarded VLAN traffic that was intended to be forwarded, and did not carry VLAN traffic that was not intended to be forwarded. Engineers also captured traffic from a trunk port to verify that all switches forwarded tagged and untagged traffic as expected. Multiple Spanning Tree Protocol (MSTP) The spanning tree protocol serves as a key loop prevention and redundancy mechanism in enterprise networks. Over the years it has been refined with updates such as multiple spanning tree (MSTP) to form a separate spanning tree instance for each VLAN. In addition to the standards-based protocols, Cisco switches use proprietary variants called per-vlan spanning tree plus (PSVT+) and Rapid PVST+. Network Test verified interoperability using three variations of spanning tree: 1. MSTP (Aruba and Cisco, using the IEEE 802.1s specification) 2. MSTP (Aruba) / PVST+ (Cisco) 3. MSTP (Aruba) / Rapid PVST+ (Cisco) In the cases involving PVST+ and Rapid PVST+, VLAN 1 was configured on the Cisco switches, while the Aruba S3500 was configured with multiple VLANs. For each variation, engineers set up redundant connections between all switches, and configured spanning tree so that the Cisco Catalyst 6506 would act as the root bridge. Engineers then offered traffic to each switch using Spirent TestCenter. The results verified spanning tree interoperability by demonstrating that that traffic was received from, and only from, the intended ports in forwarding state. Ports placed in blocking state by spanning tree did not forward traffic. For each combination of spanning tree variants, engineers then configured the Aruba S3500 Mobility Access Switch to act as the root bridge. This forced the network to converge around new spanning trees (one per VLAN). By examining the command-line interface (CLI) output on each device, engineers

Page5 verified that all switches agreed that the S3500 now acted as root. In all spanning tree test cases, all switches ensured loop-free operation and seamless convergence following configuration changes. Hot Standby Link Aruba s Hot Standby Link (HSL) technology offers an alternative to spanning tree without the latter protocol s configuration complexity. With HSL, network managers simply define primary and secondary physical ports between switches. If the primary link fails, the switches then redirect traffic onto the secondary port (the hot standby link). Aruba asked Network Test to verify that HSL would work between Aruba and Cisco switches with no additional configuration needed on the Cisco devices. As shown in Figure 2 below, engineers set up HSL by redundantly connecting the Aruba S3500 Mobility Access Switch to the Catalyst 6506 and Catalyst 4506. The S3500-Catalyst 6506 connection served as the primary link. Figure 2: Hot Standby Link Test Bed

Page6 Network Test then offered traffic between Aruba and Cisco switches, and observed traffic being forwarded only on primary links. Next, engineers physically disconnected the primary link on the Aruba switch, and Network Test verified that the switches continued to forward traffic on the secondary links. No extra configuration was needed on the Cisco switches. HSL correctly forwarded traffic both before and after a link failure. Network Test then repeated this exercise with a primary link to a Catalyst 3750 switch. Again, HSL failed over from primary to secondary links, allowing traffic to continue to flow IGMP Snooping With enterprises making ever-greater use of IP multicast for everything from videoconferencing to routing protocol updates, IGMP snooping has become a critical feature in enterprise switching. Network Test validated the ability of Aruba and Cisco switches to share information about multicast topology in a hybrid switched/routed multicast environment. In this scenario, engineers configured the Aruba S3500 Mobility Access Switch in layer-2 switching mode, with IGMP snooping enabled. Engineers then configured the three Cisco switches in layer-3 routing mode, running the Protocol Independent Multicast-Sparse Mode (PIM-SM) routing protocol. This setup represents a common design in enterprise networks: One access switch (the Aruba device) receives multicast traffic from multiple routers (the Cisco devices), and then uses IGMP snooping to determine where the multicast traffic should be forwarded. A Spirent TestCenter port attached to each Cisco device offered traffic destined to 10 multicast groups, while other test ports emulated multicast subscribers on the Aruba S3500 Mobility Access Switch. Engineers also attached an additional monitor port to the Aruba switch to verify it did not flood multicast frames to non-subscriber ports. The Aruba and Cisco devices correctly delivered multicast traffic to subscribers in all groups, and did not flood traffic to non-subscriber ports. Diff-Serv Codepoint Remarking Voice, video, and other delay-sensitive applications make heavy use of quality-of-service mechanisms such as the diff-serv codepoint (DSCP) to ensure timely traffic delivery. Switches can change the DSCP field in the IP header of incoming packets, ensuring these packets will receive special treatment as they pass through upstream devices 1. For example, a switch might change the DSCP value for incoming voice packets to ensure high-priority forwarding, which in turn keeps latency low. To verify the ability of the Aruba S3500 Mobility Access Switch to remark DSCP values, engineers set up separate VLANs for voice and data, and also configured the Aruba switch to mark all voice traffic with a 1 RFCs 2474 and 2475 define DSCP. RFC 3246 defines Expedited Forwarding.

Page7 DSCP value of 46 (which represents Expedited Forwarding, a common high-priority treatment). The Spirent TestCenter test instrument then offered traffic to both VLANs, in both cases with a DSCP value of 0. Engineers then captured traffic on the destination ports to determine if the Aruba switch had remarked the DSCP field in voice packets using a value of 46. The Aruba switch correctly remarked voice traffic with the expected DSCP value. As expected, the Aruba switch did not remark traffic in the data VLAN. Link Aggregation Network Test evaluated the ability of Aruba and Cisco devices to bundle multiple physical ports into one logical port using the IEEE 802.3ad link aggregation protocol, both on gigabit and 10-gigabit links. As shown in Figure 3 below, engineers configured the Aruba and Cisco switches to set up link aggregation groups (LAGs) across multiple physical ports. The Aruba S3500 Mobility Access switch used two 10-gigabit Ethernet links to form a single link aggregation group (LAG) with the Cisco Catalyst 6506. The Aruba switch also established LAGs using two gigabit Ethernet links apiece with each of the three Cisco switches. Spirent TestCenter offered bidirectional traffic across each LAG. In all cases, the Aruba and Cisco switches correctly forwarded traffic using link aggregation.

Page8 Figure 3: Link Aggregation Test Bed VoIP Using LLDP-MED The Media Endpoint Discovery extensions to the logical-link discovery protocol (LLDP-MED) offer a means by which end-stations can automatically learn configuration and policy settings. A common use case for LLDP-MED in enterprise settings is voice over IP: When IP phones attach to a network, they can use LLDP-MED to learn VLAN IDs and other networking parameters. Network Test validated the ability of an Aruba switch and Cisco phones to exchange LLDP-MED messages using Cisco IP phones and a Cisco PBX, as shown in Figure 4 below. In each test, engineers attached two Cisco 7942G IP phones to an Aruba S3500 Mobility Access Switch. The Cisco phones obtained network policy such as voice VLAN information via LLDP-MED exchanges with the Aruba switch, which in turn allowed the phones to register with a Cisco Unified Communication Manager

Page9 Express (CUCME) feature running on a Cisco 2901 Integrated Services Router. After the phones had registered with the PBX, engineers verified correct operation of LLDP-MED by using the port-mirroring functionality of the Aruba S3500 switch, and also by placing a call between phones. Figure 4: VoIP Interoperability Using LLDP-MED Engineers repeated the test three times, swapping in the Catalyst 6506, Catalyst 4506, and Catalyst 3750 as the device linking the Aruba switch and the Cisco 2901 equipped with CUCME. In all test cases, the Aruba switch and Cisco IP phones successfully used LLDP-MED to establish connectivity. 802.1X Authentication (S3500 as Authenticator) Network access control (NAC) introduces a new concept in enterprise network security: With NAC, the identity of a user, and not that of a machine or switch port, governs what resources the user can reach. NAC greatly enhances mobility within the enterprise by allowing users to attach anywhere within the network and still enjoy the same access rights. A fundamental building block of NAC is the IEEE 802.1X protocol, in which supplicants (clients) supply login credentials to an authenticator (such as an access switch), which in turn relays these credentials to an authentication server (typically a RADIUS server, which may be tied to a user database such as Microsoft Active Directory). As shown in Figure 5 below, Network Test validated 802.1X interoperability using a configuration commonly found in enterprise networks running Microsoft Windows. A Windows 2003 Server acted as Active Directory (AD) domain controller and also ran Internet Authentication Services (IAS) to tie AD credentials to RADIUS requests. On the client side, a PC running Windows 7 Ultimate Edition sent an 802.1X authentication request to gain access to the network. The client attached to an 802.1X-enabled

Page10 Aruba S3500 Mobility Access switch, which linked to a Cisco switch, which in turn connected to the Windows Server. (Engineers reran this test with Cisco Catalyst 6506, Catalyst 4506, and Catalyst 3750 switches between the Aruba switch and the Windows server). Figure 5: The 802.1X Test Bed In all test cases, the Aruba S3500 Mobility Access Controller and Cisco switches worked together to process a valid 802.1X request from a user. The user was then able to reach network resources as defined by the Windows Server s Group Policy. Network Test also conducted negative tests with invalid user password credentials; here, the Aruba switch correctly relayed RADIUS rejection messages. Tunneled Node With Role-Based Authentication One possible drawback of NAC is that it requires 802.1X support on the authenticator, requiring configuration of every access switch (or even replacement of access switches if they lack 802.1X capability). Aruba Networks offers an alternative: tunneled node with role-based authentication. As shown in Figure 6 below, a single Aruba 3600 Mobility Controller can act as authenticator for an entire enterprise. The Aruba 3600 sets up tunneled node using generic routing encapsulation (GRE) between itself and the Aruba S3500, with no requirement for 802.1X awareness on the S3500. With tunneled node in place, devices along the path between authenticator (the controller) and supplicant (the client) do not require any 802.1X awareness or support. Tunneled node with role-based authentication enhances the ability to scale up 802.1X authentication without the requirement to support 802.1X on every access switch.

Page11 Figure 6: Tunneled-Node Authentication To validate tunnel-node authentication, engineers set up a tunneled node between an Aruba 3600 controller and S3500 switch with a Cisco switch inline between the Aruba devices. Network Test repeated this exercise three times, swapping in the Catalyst 6506, Catalyst 4506, and Catalyst 3750 between the Aruba devices. In all test cases, tunneled node with role-based authentication correctly granted access via 802.1X authentication across a network made up of Aruba and Cisco switches. No 802.1X or GRE configuration was required on any of the Cisco switches. Because NAC is based on user identity, different classes of users may reach different resources. Network Test validated support for this capability during tests of tunneled node with role-based authentication. Engineers defined authenticated and guest user roles, with different VLANs and access rights for each. In particular, engineers configured guest access requests to be redirected to a captive-portal Web page running on the Aruba 3600 controller. Engineers then attempted to authenticate authorized and guest users via the same switch port. The system correctly granted full access to authenticated users, and redirected guest users to a captiveaccess portal running on the Aruba controller. The system correctly placed authenticated and guest users in different VLANs. MAC Authentication Just as tunneled node with role-based authentication removes the requirement for 802.1X support on every access switch, MAC authentication provides a way for supplicants (clients) to reach enterprise network resources based on source MAC address. This allows networked printers, web cameras, and legacy devices that may lack 802.1X authentication capabilities to take part in a NAC-enabled network.

Page12 To validate MAC authentication, engineers disabled 802.1X support on the client PC running Windows 7, and then reconfigured the RADIUS server to use the PC s MAC address for authentication. MAC authentication correctly granted access to a client with no 802.1X support. In a negative test case, MAC authentication did not grant access to a client supplying the wrong MAC address. Power Over Ethernet/PoE+ The IEEE power over Ethernet (PoE) and PoE+ standards describe a method for supplying power as well as data via Ethernet ports. The standards, which supply up to 15.4 and 30 watts per port respectively 2, offer an ideal method for connecting Wi-Fi access points, IP phones, and other devices that might otherwise require separate power infrastructure. Aruba asked Network Test to verify this functionality by attaching multiple PoE and PoE+ devices to an Aruba S3500 Mobility Access Switch. These devices included an Aruba AP-105 access point and two Cisco 7942G IP phones, both PoE-capable; and an Aruba AP-135 access point, which supports both PoE and the newer PoE+ specification. (The AP-135 requires PoE+ mode only when it uses both gigabit Ethernet interfaces.) In all test cases, the Aruba switch correctly supplied power to attached access points and IP phones. Conclusion These tests achieved interoperability in every case where both Aruba and Cisco devices supported a given protocol. Some test cases, such as those involving two spanning tree variants, also demonstrated interoperability between standards-based and proprietary protocols. Successful interoperability testing provides assurance to network professionals considering design or deployment of networks comprised of a mix of Aruba and Cisco devices. 2 IEEE specifications 802.3af-2003 and 802.3at-2009 describe PoE and PoE+ respectively. The 15.4- and 30-watt limits describe power at the source (in this case, the access switch); the maximum power supplied to devices is 12.95 and 25.5 watts for PoE and PoE+ devices, respectively, to account for power attenuation in the cable plant.

Page13 Appendix A: About Network Test Network Test is an independent third-party test lab and engineering services consultancy. Our core competencies are performance, security, and conformance assessment of networking equipment and live networks. Our clients include equipment manufacturers, large enterprises, service providers, industry consortia, and trade publications. Appendix B: Software Releases Tested This appendix describes the software versions used on the test bed. All tests were conducted in August and September 2011 at Network Test s facility in Westlake Village, CA, USA. Aruba Networks supplied all Aruba and Cisco devices used in testing. Component Version Aruba S3500 Mobility Access Switch ArubaOS 7.0.2.0 build 29560 Aruba 3600 Mobility Controller ArubaOS 6.1.2.2 build 29487 Aruba AP-105 ArubaOS 6.1.2.2 build 29487 Aruba AP-135 ArubaOS 6.1.2.2 build 29487 Cisco Catalyst 6506 12.2(33)SXJ Cisco Catalyst 4506 12.2(54)SG Cisco Catalyst 3750 12.2(55)SE1 Cisco 2901 Integrated Services Router 15.0(1)M5 Cisco 7942G 8.3(3)SR2S Spirent TestCenter 3.62.0686.0000 Appendix C: Disclaimer Network Test Inc. has made every attempt to ensure that all test procedures were conducted with the utmost precision and accuracy, but acknowledges that errors do occur. Network Test Inc. shall not be held liable for damages, which may result for the use of information contained in this document. All trademarks mentioned in this document are property of their respective owners. Version 2011092600. Copyright 2011 Network Test Inc. All rights reserved. Network Test Inc. 31324 Via Colinas, Suite 113 Westlake Village, CA 91362-6761 USA +1-818-889-0011 http://networktest.com info@networktest.com