Powers TM Controls SW 141 Differential Static Airflow Switches

Similar documents
Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

POWERS CONTROL RC 195 Single Input Receiver-Controller

RC 195 Multiple Input Receiver-Controller

POWERS Controls No. 4 Pneumatic Damper Actuator

Powers Controls TH 192 S Single Temperature Room Thermostat

General Information... 2

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

PIEZOMETER AIRFLOW MEASURING RING

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Pressure Switch for gas and air

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

! WARNING. Before using product, read and understand instructions.

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

DUCT SMOKE DETECTOR D4120

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Cooling Capacity CFM in. w.c. (125 Pa)

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

P70, P72, and P170 Series Controls for Dual Pressure Applications

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Electronic, Digital and Mechanical Vibration Switches

Part I - Installation

B-Series Switches Pressure, Differential Pressure & Hydraulic

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

, User s Manual

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

SLIM LINE FUME HOOD MONITOR

Model 43AP Pneumatic Controller, Style B

How To Drive A Compact Serie 1

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

SQUARE D INDUSTRIAL CONTROL PRODUCTS

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Radiant Temperature Sensor TY7321

Assisted lift operated 2/2-way solenoid valves Type EV250B

167D Series Switching Valves

HERZ-Thermal Actuators

300 Series PA Pump and Cooler Assemblies

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Pressure controls, type KP

T7560A,B,C Digital Wall Module

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

PRODUCT PROFILE FEATURES

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

Fisher 377 Trip Valve

Installation Manual. TITUS I, II, and IIA Pneumatic Controls Installation, Operation, and Maintenance Manual. (See Figure 3) (Label, See Figure 3)

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

HEAVY DUTY STORAGE GAS

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

AMD-33 Air Measuring Station with VCD-33 Control Damper

Your safety and the safety of others are very important.

T7079A,B Solid State Remote Temperature Controllers

Electronic Control Devices The European Product Catalogue 2007

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

T 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ

Self Purging Liquid Trap (SPLT ) User s Manual

Commercial Gas Cooking Thermostats

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

E2 Series Electric Furnaces

3/2-way Solenoid Valve, direct-acting, NC or NO

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Electronic Control Devices The European Product Catalogue 2007

Application Engineering

Fire Pump Controllers Remote Alarm Panels

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

B-Series Temperature Switches

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Advantium 2 Plus Alarm

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

G234X-55 Conventional Gas Boiler

Digital inductive conductivity transmitter

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ABC-1000 Automatic Boiler Level Controller Operation and Installation Manual

Proportional pressure regulators VPPE

PNEUMATIC CONTROLS Selection and Description

P66 Series Electronic Fan Speed Controls

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

HMI display Installation Guide

Centro-Matic Automatic Lubrication Systems System Controls

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

F9MXE. Product Specifications

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Solid State Timers Type F

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Transcription:

Powers TM Controls SW 141 Differential Static Airflow Switches Document No. 155-052P25 SW 1 0518 Description Application The SW 141 Airflow Switch senses static differential pressure and the diaphragm operated snap switches actuate electrical circuits. Auto reset and manual reset models are available. Auto reset switches (0518 and 0574) should be used for applications requiring positive proof of airflow (or fan operation) or to detect high differential pressures associated with dirty air filters or similar maintenance alarms not requiring safety lock-out (shut down) of the fan. The manual reset switch (0575) should be used for applications requiring safety lock out (shut down) of the fan. The switch can be used on the fan discharge (positive pressure), fan inlet (negative pressure), or across the fan (differential pressure) to detect excessively high positive pressures or low negative pressures, and turn off the fan before damage occurs to ducts or dampers. Product Numbers Table 1. Product Number Setpoint Range (Field Adjustable) Setpoint * Accuracy Switching * Differential Switching Action 0518 1 to 12 WC (250 Pa to 3000 Pa) @ 12 ± 1.5 WC (3000 Pa ± 375 Pa) Approx. 0.6 to 1.5 WC (150 Pa to 375 Pa) SPDT/ Auto Reset 0575 1 to 12 WC (250 Pa to 3000 Pa) @ 12 ± 1.5 WC (3000 Pa ± 375 Pa) Not Applicable SPST/ Manual Reset 0574 0.05 to 1.0 WC (12.5 Pa to 250 Pa) @ 1 ±0.2 WC (250 Pa ± 50 Pa) Approx. 0.06" to 0.6 WC (15 Pa to 150 Pa) SPDT/ Auto Reset * Setpoint accuracy tolerance and switching differential decrease proportional to setpoint decrease.

SW 141 Differential Static Airflow Switches Specifications Measured media Air Operating Switch action Auto reset See Table 1 Manual reset Switch is Normally Closed (N.C.) and only opens on increasing pressure signal. Switch must be manually reset by operator Ambient temperature range 40 F to 180 F ( 40 C to 82 C) Maximum overpressure 0.5 psi (3.4 kpa) Mounting position Diaphragm in any vertical plane Physical Electrical ratings Non inductive - 15 amps @ 120-277 Vac Pilot Duty - 300 VA @ 120-277 Vac Conduit opening One, conduit size 1/2-inch Sample line connectors Two connectors, complete with nuts and ferrules, which accept 1/4-inch OD (6.4 mm) copper or poly tubing Material Aluminized steel Agency certification U.L. MFHX File MH9888 CSA 1811M25 Weight 1 lb (0.45 kg) Dimensions See Figure 9 Accessories High accuracy static pressure sensor 269-062 Static pressure sensing kit 189-142 Operation The diaphragm operates a spring lever to actuate the snap switch. The manual reset switch keeps the electrical contact open until pushed to reset. Turning the adjustment knob clockwise increases the setpoint. Installation Mount the unit with the diaphragm in any vertical plane. Connect the static pressure line(s) as shown in Figure 1. Switch Nut & Integral Ferrule Tubing SW0097R1 Figure 1. Connecting the Static Pressure Line. Page 2

SW 141 Differential Static Airflow Switches Installation, Continued For use as a negative pressure switch: Connect the static pressure line to the low inlet (marked on the case and Figure 2) and leave the high inlet open to the atmosphere. For use as a positive pressure switch: Connect the static pressure line to the high inlet (marked on the case and Figure 2) and leave the low inlet open to the atmosphere. For use as a differential pressure switch: Connect the highest static pressure line to the high inlet and the lowest static pressure line to the low inlet (marked on the case and Figure 2.) 0518 0574 0575 Figure 2. Switches with Covers Removed. Setpoint Adjustment Each switch is factory set at the minimum setpoint. See Table 1. 1. To increase the setpoint, turn the adjustment screw clockwise as shown in Figure 2 and Figure 3. From the lowest setpoint, several turns are necessary to engage the adjusting mechanism. 2. Adjust the setpoint until switching occurs at the required point. 3. Check the setpoint for accuracy with a magnahelic gauge. SW0096R1 The Red Band Is The Setpoint Location On The Scale " WC 3.0 9.0.05 6.0 12.0 Figure 3. Adjusting the Setpoint. Page 3

SW 141 Differential Static Airflow Switches Pressure Sensors Pressure sensor selection is based on the medium to be measured, the measurement type (static or velocity), and the required range and accuracy. Pressure sensors measure the difference between two sensing ports usually labeled high and low. This provides a pressure measurement against a reference. Measuring the pressure inside a pipe or duct and comparing it to the air outside (ambient) the pipe or duct is an example of static pressure measurement. A sensor measuring the pressure differential across a pump or chiller measures velocity pressure. Figure 4. Pitot Tube (Part Number 269-062). Wiring Diagrams Before setpoint pressure is applied to the diaphragm, the switch contact is in a normally closed position as shown in Figures 5 and 6.. Figure 5. Manual Reset Switch 0575. Figure 6. Auto Reset Switches 0518 and 0574. SPDT terminals are marked Common (C), Normally Open (NO), and Normally Closed (NC). Figure 7. Auto Reset Switches to Prove Excessive Airflow or Pressure. Page 4

SW 141 Differential Static Airflow Switches Wiring Diagrams, Continued Figure 8. Auto Reset Switches to Prove Insufficient Airflow or Pressure. Dimensions 3.25 (82) 1.63 (41) 0.44 (11) 3.25 (82) 1.38 (35) 2.81 (71) 6.13 (156) 0.19 (5) dia hole High Pressure Inlet Low Pressure Inlet SW000098R1 3.88 (98) 1.94 (49) 0.78 (20) 0.71 (18) Figure 9. Dimensions in Inches (Millimeters). Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Powers is a registered trademark of Other product or company names mentioned herein may be the trademarks of their respective owners. 2010 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 U.S.A. Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com Document No. 155-052P25 Printed in the U.S.A. Page 5