Floor Openings in Two-Way Slabs

Similar documents
SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

Fire and Concrete Structures

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Design Of Reinforced Concrete Structures ii Two-Way Slabs

9.3 Two-way Slabs (Part I)

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Detailing of Reinforcment in Concrete Structures

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

POST AND FRAME STRUCTURES (Pole Barns)

Chapter 8. Flexural Analysis of T-Beams

Design and Construction of Cantilevered Reinforced Concrete Structures

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA

Technical Notes 3B - Brick Masonry Section Properties May 1993

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

Excerpts from the Canadian National Building Code (NBC)

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

In-situ Load Testing to Evaluate New Repair Techniques

SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED

Guidelines for the Design of Post-Tensioned Floors

Design Manual to BS8110

COMMONLY USED RESIDENTIAL BUILDING CODES

Concrete Design Manual

Requirements for the Use of PRESSS Moment-Resisting Frame Systems

FUTURE SLAB. PENETRATIONS and. DEMOLITION of POST-TENSIONED FLOORS

Technical Assignment 2 TABLE OF CONTENTS

Optimum proportions for the design of suspension bridge

Installation Instructions

A Case Study Comparing Two Approaches for Applying Area Loads: Tributary Area Loads vs Shell Pressure Loads

The Analysis of Open Web Steel Joists in Existing Buildings

Requirements for Building Application Submission

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

Chapter - 3 Design of Rectangular Beams and One-way Slabs

PANELIZED HOME INSTALLATION GUIDELINE

Residential Foundations and Basements

How To Make A House Safe

Formwork for Concrete

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

Hanson Building Products. precast basement solutions

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

Page & Turnbull imagining change in historic environments through design, research, and technology

6 RETROFITTING POST & PIER HOUSES

1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP

Section 5A: Guide to Designing with AAC

How To Build A Luxury Apartment Complex In London

The Strength of Concrete

Lighthouse Engineering, L.L.C.

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

The following sketches show the plans of the two cases of one-way slabs. The spanning direction in each case is shown by the double headed arrow.

ADVANCED SYSTEMS FOR RATIONAL SLAB REINFORCEMENT

[TECHNICAL REPORT I:]

Chapter 2 Basis of design and materials

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

What is Seismic Retrofitting?

Residential Deck Safety, Construction, and Repair

Simplifying design and construction. Alan Tovey, Director The Basement Information Centre

GEORGE J. CAMBOURAKIS, P.E., C. ENG. PRESIDENT & CHIEF STRUCTURAL ENGINEER

THE ULTRASONIC TOMOGRAPHY TESTS OF CONCRETE IN FOUNDATION SLAB

Building Construction. Lightweight construction. Conventional Construction

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Structural Analysis. EUROCODE 2 Background and Applications

APE T CFRP Aslan 500

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Measurement Standards for Structures

Pollution CO CO 2. Carbonaceo us soot H 2 S, NOX, SO2

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

DESIGN OF PRESTRESSED BARRIER CABLE SYSTEMS

The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma

Raising the Roof Creating Roofs in Revit David Cohn

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

State of Connecticut Department of Public Health RADON PROGRAM

Guidelines for Earthquake Bracing of Residential Water Heaters

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

FORM DESIGN. easy to work with, and generally available.

Construction Laborer Dies after Falling off Collapsed Precast Concrete Floor Slab

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels

St. John s University

Treatment Practice for Controlling Water Damage in the Annular Space of Shaft Freezing Hole

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

How To Design A Post Tensioned Deck For A Building

FOOTING DESIGN EXAMPLE

GRC Porticos. Lightweight entrance porticos ABBEY ARTSTONE

CONCRETE REPAIR GUIDELINES. Concrete repairs can be broken down into four basic types, plus special repairs and planing.

A transverse strip of the deck is assumed to support the truck axle loads. Shear and fatigue of the reinforcement need not be investigated.

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

Residential Accessory Buildings

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

Transcription:

Floor Openings in Two-Way Slabs By Mike Mota, P.E. - Portland Cement Association, Skokie, Illinois Mahmoud Kamara, Ph.D. Portland Cement Association, Skokie, Illinois 1. Introduction: Openings in slabs are usually required for plumbing, fire protection pipes, heat and ventilation ducts and air conditioning. Larger openings that could amount to the elimination of a large area within a slab panel are sometimes required for stairs and elevators shafts. For newly constructed slabs, the locations and sizes of the required openings are usually predetermined in the early stages of design and accommodated accordingly. The ACI 318 Building Code permits openings of any size in any new slab system, provided that an analysis is performed that demonstrates that both strength and serviceability requirements are satisfied (ACI 318-02 13.4.1). The analysis for slabs containing openings could be complex and time consuming, as an alternative the ACI 318 Code gives guidelines and limitations for opening location and size. If the designer satisfies those requirements the analysis could be waived. Modifications to an existing structure, although not frequent, occur in almost every structure. New slab openings or penetrations in an existing concrete building are easily accommodated in the majority of instances. However, the analysis required, and the remedies are typically more involved than similar openings in a new slab. The purpose of this article is to offer the structural engineer with guidance on selecting locations and sizes for openings in two-way slabs for both new and existing structures. 2. Openings in New Slabs: For the purposes of design, a two-way slab system is divided into column and middle strips in two perpendicular directions. The column strip width on each side of the column centerline is equal to one quarter the length of the shorter span in the two perpendicular directions. The middle strip is the strip bounded by two column strips. 1

As an alternative to detailed analysis for slabs with openings the ACI 318 gives the following guidelines for opening size in different locations for slabs without beams: In the area common to intersecting middle strips, openings of any size are permitted (13.4.2.1). In the area common to intersecting column strips, maximum permitted opening size is one-eighth the width of the column strip in either span (13.4.2.2). In the area common to one column strip and one middle strip, maximum permitted opening size is limited such that only a maximum of one-quarter of slab reinforcement in either strip may be interrupted (13.4.2.3). To apply this simplified approach, ACI 318 requires that the total amount of reinforcement calculated for the panel without openings, in both directions, must be maintained; thus, reinforcement interrupted by the opening must be replaced on each side of the opening. Figure 1 illustrates the provisions of 13.4.2 for slabs with l2 >l1 In addition to flexural requirements, the reduction in the slab shear strength must also be considered when the opening is located: (1) anywhere within a column strip of a flat slab system and (2) within 10 times the slab thickness from a concentrated load or reaction area. The effect of the slab opening is evaluated by reducing the perimeter of the critical section by a length equal to the projection of the opening enclosed by two-lines extending from the centroid of the column and tangent to the opening; see Fig 2. 3. Openings in Existing Slabs: Cutting openings in existing slabs should be approached with caution and avoided if possible 3. When cutting opening in existing slabs the effect on the slab structural integrity must be evaluated. For existing slabs it is advisable to analyze the slab first for excess capacity and possible moment redistribution before deciding on the sizes and locations of the openings. Small openings in existing slabs are usually cored to the required diameter. Large openings are cut with a circular saw or concrete chain saws with plunge cutting capabilities. When using

circular saw, circular cores can be made at the corners of the required opening first and connected by saw cutting to avoid cutting longer slot at the top than the bottom of the slab. Reference 3 provides some guidelines for cutting openings in existing slabs. These guidelines are summarized as follow: 3.1 Openings in Existing Flat Plates: Figure 3 shows suggested areas where openings can be made. Because punching shear capacity of the floor around the column typically governs the design of flat plates, any openings in Area 3 should be avoided as much as possible. If openings must be made in this area, for example to install a drainage pipe, the suggested size of the opening should be no larger than 12 inches. It should be noted that openings cut in this area could reduce the critical section considered for resisting punching-shear as explained in ACI 318-02 Section 11.12.5. Area 2, located at the intersection of column and middle strips is less critical than area 3. Suggested small openings having a width less than 15 percent of the span length can be made in this area. 3.2 Openings in Existing Slabs Supported on Beams: For opening locations in slabs supported on beams, the situation is reversed. Openings in zone 3, (intersection of two column strips) can be cut with dimensions up to one-quarter of the span. Openings are not recommended in zone 2 (intersection of column strip and middle strip). Openings with maximum dimensions of one-eighth of the span can be cut in zone 1 - intersection of middle strip. When removing entire panel of slab between beams, it is recommended to leave some overhang to allow development of reinforcing bars from adjacent spans. In this case the beams should be checked for torsion. The beams in this case may need to be strengthened. Additional information for strengthening beams can be found in Reference 3.

References: 1. Building Code Requirements for Structural Concrete, ACI 318-02, American Concrete Institute, Farmington Hills, MI, 2002 2. Notes on ACI 318-02, 8 th Edition, EB702, Portland Cement Association, Skokie, Illinois, 2002 3. Alexander Newman, Structural Renovation of Buildings - Methods, Details, and Design Examples, McGraw-Hill, 2001 4. Robert Park, Reinforced Concrete Slabs Second edition, Wiley, 2000

Figure 1 Suggested opening sizes and locations in flat plates 6

Figure 2 Suggested slab opening locations in vicinity of column Figure 3 Suggested openings in slab

(505 Fifth Avenue, NYC Courtesy: Rosenwasser/Grossman, NYC) Figure 4 Large opening in flat slab floor