SEPAR FILTER SEPAR 2000 SEPAR 2000



Similar documents
2004 Technical Manual

Diesel Fuel Filtration

2011 Separ UK Catalogue Rev 1103

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

Jobson THE RIGHT CONTACT

How To Make A Fuel Manager Filter/Separator

CSD WATER REMOVAL FILTERS FOR DIESEL

DIESEL FUEL CONDITIONING

Pre-Filtration for Ultimate Cleanliness and Efficiency: HYDAC Diesel PreCare. Dual function: Diesel filtration + Water removal

Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives

Waste Oil Handling, Spill Containment & Lighting

REMOVAL AND INSTALLATION

Zenith Solar thermal 4.5m pump station Installation manual

Signature and ISX CM870 Fuel System

Oil and Coolant Circulating Heating System. Model - OCSM

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

6.7L Diesel Fuel System Contamination Diagnosis and Service Procedure Job Aid (Revised March, 2012)

4" SUBMERSIBLE PUMPS

The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants

Backflush filter R8-30W

Fixed displacement vane pumps

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

David O. Ahrens, Commercial Marine Manager Caterpillar Engine Products Division

DIESEL FUEL FILTER/WATER SEPARATORS & Recycler Systems

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Rexroth Hydraulic Pump A10VO Series User Manual

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

VOYAGER 570G. 744A Sprayer Control

100 SERIES. Diesel Fuel/Water Separators. Installation. Operation. Parts. Service Information


Technical Guide 08/15/14

In-Line Filters and Coalescers with Automatic Drains

Diesel Fuel Additive Heavy Duty Applications. December 2011

Vertical selfpriming Side-Channel Pumps Type WPV

Master Catalogue I August 2011

Automatic filters for fuel and lubricating oil. Technical information for oil filtration

Model 1210C Battery Powered Pump Shown. Description

Hydraulic Control Solutions

Condensate water pump with neutralisation system

swimming pool accessories

Oil Filtration Systems. Filtakleen By-Pass Oil Filter INSTALLATION INSTALLATION & & SERVICE MANUAL MANUAL

M A N U A L

Select Radiators Installation Guide

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Carburetion Troubleshooting Quick Reference Guide

Flex separation systems, S-separators

Change the Way You Spray to Minimize Clogging

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Automatic Back-Flushing Filter AutoFilt RF9.

300 Series PA Pump and Cooler Assemblies

Product catalogue, pipe and sewer cleaning systems

FLASH TANK ECONOMIZER PRODUCT GUIDE

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Pressure Vessels (Air Compressors) and LPG Tanks

Assembly and instructions

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Pressure regulating valve with modulating kit, type DRV

CHEMICAL CLEANING UNIT Product number:

Troubleshoot resources for homeowner

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Mechanical Seal Piping Plans

UNITOR ULTRASONIC cleaning

Kompressoren. Adsorption Dryer AD

Kompressoren. Oil Water Separators OWS

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

Fuel Injection Systems. dedicated to high-precision

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Marine after-treatment from STT Emtec AB

Electric Instantaneous. Water Heaters. Service manual

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Dewatering containers

Solar Hot Water Heaters

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

In-Line Air Separators

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

AIR AND DIRT SEPARATORS. Flamco FLEXVENT. Air and dirt separators FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S.

UNITOR VACUUM cleaners

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Filter Housing SG Standard

Removing Solids with Automatic Self-Cleaning Filters

Midwest Industrial Tanks

Copyright 2012 Mayekawa Mfg. Co.,Ltd. All Rights Reserved.

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

Overflow valve with thread connection

Rotary screw compressors kw 5,5 7, , bar MODULO

BROADFIELD SECURITY SERVICES WATER FILTRATION AND PURIFICATION SOLUTIONS

Bedienungsanleitung Diesel-Set 1 (Niederdruck)

Transcription:

2000 The 2000 is a water separator and fuel filter for light diesel fuel. An entirely new multistage centrifugal system ensures a 100% solution to the problem of water and particulate in fuel. 2000 offers: Most compact design High effiency Low flow restriction Long life filter element Easy installation Simple maintenance

FLOW SCHEME 2000 Bleed Screw out C D out in A B in Drain Valve (push in and turn yellow knob)

WATER ATOR AND FUEL In 1992 Willibrord Lösing Filter-Technik designed the next generation of Filters called the 2000 Series of fuel filters, as an effective system for the separation of water and particulate from fuel. Both water and particulate matter can result in high wear and tear of fuel pumps and injectors, resulting in reduced reliability and expensive engine repairs. FUNCTION OF THE 2000 The separation and filtration process takes place according to a new, unique and patented concept, which is applied throughout all of the range. The 2000 series is outstanding due its small physical size in relation to the effective flow rate. The 2000 should be installed on the suction side of the fuel system, between the fuel feed tank and the engine mounted fuel lift pump. Fuel enters the filter through either port A or B depending which is more convenient for installation, and using the plug provided to seal off the unused port. From the inlet port, fuel flows through the interior vane system which imparts a circular motion to the fuel. Still in the circular motion fuel reaches the bowl section, where, due to this centrifugal motion water droplets and heavier particles (down to 30 microns in size) are forced to the wall of the bowl, eventually settling in the bottom of the bowl. In this stage the fuel has to pass the vane system positioned on the outside of the central housing. Due to the differing length of the vanes and the twofold rapid change of fuel flow direction, smaller water droplets and finer particles will settle on the vanes. These settlements will agglomerate and when heavy enough fall to the bottom of the bowl. Already at this point the major portion of any contaminates in the fuel have been separated. Just below the filter element the flow area of the filter is increased significantly thus reducing the fuel flow rate. This calming effect allows even smaller water droplets and particulate to fall out settling on the inner surfaces of the housing, forming larger droplets which eventually fall into the bottom of the bowl by gravity. Due to the before described pre-separation process, the major portion of water and particulate present in the fuel will be in the bowl or on the inner surfaces of the filter, thus greatly extending the filter element life. The final filtration of the remaining water and particulate still contained in the fuel will be effected by a replaceable filter element. These filter elements are produced from a special filter media and are available in diffrent pore sizes. The clean fuel leaves the filter via outlet ports C or D (the outlet port not required should be sealed with the plug provided).

BACKFLUSHING PROCESS Switch off the engine.open the bleed valve on top of the filter lid (note: If fuel tank is above the top of the filter close the fuel feed valve if fitted) then open the drain valve fitted to the bowl.the clean fuel between the filter lid and the clean side of the element will flush back through the filter element and wash off the collected waterdroplets and particles from the filter media. At the same time fuel that is draining from the bowl is carrying contaminates out with it. Close the drain valve open the fuel feed valve and prime the fuel system. Close the bleed valve. Now the engine can be re-started. If the engine is not able to reach maximum revolutions then the element requires to be replaced. INSTALLATION OF THE The 2000 can be easily installed. The 2000 should be installed on the suction side of the fuel system, between the fuel feed tank and the engine mounted fuel lift pump. Install the 2000 filter in an accessible position. (Any other primary filter has to be removed from the suction line.) The 2000 housing has two inlet and two outlet ports to give options on installation postion. The ideal position for the filter is at the same height as the lift pump. However if the top of the fuel tank is above this position a full flow ball valve should be fitted, before the filter so that the fuel flow can be shut off to allow filter maintenance. In application where the fuel level is below the filter it is still advisible to install a full flow ball valve to prevent fuel draining back into the fuel tank. After filter installation on system without a positive head of fuel, remove the filter lid and fill with fuel to assist in priming the system. Please use only fittings with o-ring seals (contained in our program of accessories). Do not use hollow bored screws with copper rings as they are difficult to seal and result in a high pressure drop. Please consider a clear space of 60 mm above the housing/filter lid to replace the filter element. Important: Only clean diesel fuel should be used to clean the clear plastic bowls, certain cleaning materials can attack the plastic material and have a detrimental effect. The 2000 filters are available in special biodiesel (Cannola) resistant versions on request. Avoid sharp 90-degree bends on the fuel system piping as these increase system pressure drop, as does any reduction in the internal diameter of fuel piping.

MAIN FEATURES Available with various flow rates from 1 to 260 l/min. Thereby offering fuel filters for an engine performance range of 5 to 10,000 kw. Compact size, various ports, simple installation High separation efficiency of water which is contained in the fuel. (No water could be proven acc. to RTÜV testing.) Due to the backflushing extended service time of the filter elements. The 2000 Filter protects the injection pump and injection nozzles. Easy maintenance of the 2000 filter. APPICATION OF THE Automotive industry - trucks, busses, mobile cranes, municipality vehicles etc. Construction equipment, compressor sets, agricultural equipment, fork lift trucks etc. Marine propulsion Stationary engines - generators, welding and pumping installations etc. Mining applications Special versions for certain applications are available. MARINE APPLICATIONS TEST AND CERTIFICATES For this purpose switchable filters are available. A water level indication can be supplied optionally. GAS/PETROL APPLICATIONS For gas/petrol engines special versions are available. Rheinisch-Westfälischer TÜV Kraftfahrt-Bundesamt Flensburg German Technical Department for Army Ship and Marine Weapons Germanischer Lloyd Type Approval Certificate Lloyd Type Approval Certificate Bureau Veritas Type Approval Certificate EXTREME TEMPERATURES RINA For cold ambient temperatures 2000 filters are available with an effective heating system.

DELIVERY PROGRAM FLOW RATES 2000/5 = 5 l/min or 300 l/h 2000/5/50 = 5 l/min or 300 l/h 2000/10 = 10 l/min or 600 l/h 2000/18 = 18 l/min or 1080 l/h 2000/40 = 40 l/min or 2400 l/h 2000/130 = 130 l/min or 7800 l/h 2000 AVAILABLE VERSIONS DIESEL 2000 OPTIONS = Clear bowl U = Switchable filter D = Clear bowl with heat shield (RINA-version) K = Clear bowl with contacts for water level indication KD = Clear bowl, heat shield, contacts for water level M = Metal bowl MK= Metal bowl with contacts B = Gas/Petrol version clear bowl BM = Gas/Petrol version with metal bowl S = Potentialfree probe for water level indication H = Heated filter 12V or 24 SINGLE UNITS SWITCH. UNITS SINGLE UNITS SWITCHABLE UNITS DESCRIPTION L/MIN Thread Thread In- and Outlet In- and Outlet SWK-2000/5 SWK-2000/5/U Clear bowl 5 M 16 x 1,5 12 mm Pipe Ø SWK-2000/5/50 SWK-2000/5/50/U Clear bowl 5 M 16 x 1,5 12 mm Pipe Ø SWK-2000/5/50/K SWK-2000/5/50/UK Clear bowl, contacts 5 M 16 x 1,5 12 mm Pipe Ø SWK-2000/5/50/D SWK-2000/5/50/UD Clear bowl, heat shield 5 M 16 x 1,5 12 mm Pipe Ø SWK-2000/5/50/KD SWK-2000/5/50/UKD Clear bowl, contacts, heat shield 5 M 16 x 1,5 12 mm Pipe Ø SWK-2000/5/50/M SWK-2000/5/50/UM Metal bowl 5 M 16 x 1,5 12 mm Pipe Ø SWK-2000/5/50/MK SWK-2000/5/50/UMK Metal bowl, contacts 5 M 16 x 1,5 12 mm Pipe Ø SWK-2000/5/50/H Clear bowl, heated filter 5 M 16 x 1,5 SWK-2000/10 SWK-2000/10/U Clear bowl 10 M 22 x 1,5 15 mm Pipe Ø SWK-2000/10/K SWK-2000/10/UK Clear bowl, contacts 10 M 22 x 1,5 15 mm Pipe Ø SWK-2000/10/D SWK-2000/10/UD Clear bowl, heat shield 10 M 22 x 1,5 15 mm Pipe Ø SWK-2000/10/KD SWK-2000/10/UKD Clear bowl, contacts, heat shield 10 M 22 x 1,5 15 mm Pipe Ø SWK-2000/10/M SWK-2000/10/UM Metal bowl 10 M 22 x 1,5 15 mm Pipe Ø SWK-2000/10/MK SWK-2000/10/UMK Metal bowl, contacts 10 M 22 x 1,5 15 mm Pipe Ø SWK-2000/10/H Clear bowl, heated filter 10 M 22 x 1,5 SWK-2000/18 SWK-2000/18/U Clear bowl 18 M 26 x 1,5 22 mm Pipe Ø SWK-2000/18/K SWK-2000/18/UK Clear bowl, contacts 18 M 26 x 1,5 22 mm Pipe Ø SWK-2000/18/D SWK-2000/18/UD Clear bowl, heat shield 18 M 26 x 1,5 22 mm Pipe Ø SWK-2000/18/KD SWK-2000/18/UKD Clear bowl, contacts, heat shield 18 M 26 x 1,5 22 mm Pipe Ø SWK-2000/18/M SWK-2000/18/UM Metal bowl 18 M 26 x 1,5 22 mm Pipe Ø SWK-2000/18/MK SWK-2000/18/UMK Metal bowl, contacts 18 M 26 x 1,5 22 mm Pipe Ø SWK-2000/40/M SWK-2000/40/UM Metal bowl 40 M 33 x 2,0 35 mm Pipe Ø SWK-2000/40/MK SWK-2000/40/UMK Metal bowl, contacts 40 M 33 x 2,0 35 mm Pipe Ø SWK-2000/40/MS SWK-2000/40/UMS Metal bowl, probe 40 M 33 x 2,0 35 mm Pipe Ø SWK-2000/40/2/MK Metal bowl, contacts 80 42 mm Pipe Ø SWK-2000/130/MK SWK-2000/130/UMK Metal bowl, contacts 130 2 Pipe 2 Pipe SWK-2000/130/MS SWK-2000/130/UMS Metal bowl, pot.-free probe 130 2 Pipe 2 Pipe SWK-2000/130/2/MK Metal bowl, contacts 260 3 Pipe AVAILABLE VERSIONS GAS/PETROL SWK-2000/5/50/B Clear bowl 5 M 16 x 1,5 SWK-2000/5/50/BM Metal bowl 5 M 16 x 1,5 SWK-2000/10/BM Metal bowl 10 M 22 x 1,5 Other versions could be supplied on request The 2000 filter is available with diffrent pore sizes of the filter media Sizing of the 2000 filter: The flow rate l/min of the filter has to be higher than the maximum capacity of engine mounted fuel lift pump. F.i. Maximum flow rate of the fuel lift pump 8 l/min - corresponding filter SWK 2000/10 with a maximum flow rate of 10 l/min It is advisable to use switchable filters for marine applications, especially when a vessel is fitted with only one propulsion engine. Willibrord Lösing Filter-Technik Postfach 866009 45517 Hattingen Essener Straße 108 45529 Hattingen Telefon 02324/94600 Telefax 02324/40842