Sterile E Online NetworkTutorials



Similar documents
Biological Indicators and

or

Steam Sterilization and the 2007 Revision of PDA Technical Report 1

STATIM G4 Cassette Autoclaves From start to dry in the blink of an eye.

Penetration tests according to the ISO 11140

Sterilization of narrow channels: how to ensure effectiveness in daily routine? Dr.ir. Josephus Paulus Clemens Maria Van Doornmalen Gomez Hoyos

AUTOCLAVE STEAM STERILIZERS

Chemical Indicators & Accessories from Albert Browne International Ltd. Assurance through Technology

Steam Sterilization Cycles for Lab Applications

Papers. Papers. Abstract. Introduction

COMPANY P R O F I L E

STERILIZATION AND DISINFECTION

The Supplier Perspective: Sterilization. Presented by: Thad Wroblewski STERIS Isomedix Services

STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:

solarplus solar systems general features

Air Removal from the Sterilization Chamber

Medical Market Laboratory EMEA

EH&S. Sheet. Fact. Safe and Effective Use of Autoclaves. What are autoclaves? Factors for effective sterilization. Dry heat cycle - when to use

JEDEC SOLID STATE TECHNOLOGY ASSOCIATION

3 Attest Biological Monitoring System

Top 10 considerations when validating an autoclave

Med-Info. Council Directive 93/42/EEC on Medical Devices. TÜV SÜD Product Service GmbH

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Pharmatec GmbH. Packaging Technology. Pharmatec GmbH

Core Fittings C-Core and CD-Core Fittings

Updates on CFPP and Standards

Safety data sheet according to 1907/2006/EC, Article 31

Laboratory- and sterilisation equipment HMC EUROPE

Guidance on safe use of Autoclaves

Medical Market Laboratory EMEA

FVA/A1 saturated-steam sterilizer

Medical Waste Autoclaves. Medical Waste Autoclaves

Basic Properties and Application of Auto Enamels

Material data sheet. EOS MaragingSteel MS1. Description

Safety Data Sheet UN-GHS (Rev.4) (2011) Update: Version: 1.3

DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported

Safety Data Sheet UN-GHS (Rev.4) (2011) Update: Version: 1.2

ETC -SV. Class 0 oil-free compressed air through catalysis

A terminology model approach for defining and managing statistical metadata

OVERVIEW. Toolbox for Thermodynamic Modeling and Simulation with MATLAB /Simulink. Key Features:

Novell SUSE Linux Enterprise Virtual Machine Driver Pack

MATERIAL SAFETY DATA SHEET Version : -

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

Steam Sterilization Principles

Sterilization A REVIEW OF THE BASICS. By Gayla Tilton and Myrna Kauffman 66 MANAGING INFECTION CONTROL

NEW SMART STEAM DISTILLATION VAPODEST 200 VOLATILES SO 2 ALCOHOL PHENOLS KJELDAHL-N UNRIVALED EASE OF USE EFFICIENCY FUNCTIONS SAFETY

Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application

Monitoring the autoclaving process in the pharmaceutical industry

Hydrogen Leak Detection XRS system. The complete system for leak detection using hydrogen gas

Sterilizers with extra class

SUPERHEATED STEAM/VACUUM DRYING TIMES FOR THICK LUMBER

CENTRAL SERVICE REGULATIONS FOR AMBULATORY SURGERY CENTERS

THE BASICS OF STERILIZATION

Cree XLamp XR-E LED. Table of Contents. CLD-DS05 Rev 16B. Product family data sheet

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

LABOKLAV. Autoclaves Made in Germany.

PARALOID KM-1 Acrylic Impact Modifier

Jet Press 720. B2 sheet-fed inkjet digital press

How To Manage Medical Waste In Turkistan

2. Laboratory equipment

Polyimide labels for Printed Circuit Boards

How To Fit A T.V Door Closer

Best Practices for Loaner Surgical Instruments

CHARACTERIZATION OF HIGH PRESSURE RTM PROCESSES FOR MANUFACTURING OF HIGH PERFORMANCE COMPOSITES

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

Effective Heat Sterilization in CO 2 Incubators

PRODUCT / APPLICATION INFORMATION

Clinic Washer-Disinfectors. Washer-Disinfector Line

Assembly and Installation Procedures

Sterilization methods and equipment Lab 1-2

Safety Data Sheet in accordance with regulation (EC) 1907/2006 Update: Version: 1.2 Kresto kwik-wipes [ KRESTO KWIK-WIPES ] Page 1 of 6

The effect of cold chain on mushroom quality. Dr John Collier Monaghan Mushrooms

Single-Use Flow-Through Cell ph FTC-SU-HP8

Compliance Bulletin Solid Waste Medical Waste Treatment reviewed/revised February 2012

MATERIAL SAFETY DATA SHEET Version : -

Hazard Analysis and Critical Control Points (HACCP) 1 Overview

German engineering under high pressure

Onboard Quality Controls for the CoaguChek XS System

Vibration Exposure Assessment for Industrial Power Tools

EU Safety Data Sheet. Vival NF. Vival NF

PETITION FOR EVALUATION AND APPROVAL OF REGULATED MEDICAL WASTE TREATMENT TECHNOLOGY PART A: GENERAL INFORMATION

Technology Solutions. Man a g e th e ch a n g i n g Rec o r d s Ma n a g e m e n t. More than 90% of records created today are electronic

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2

Sterile Cleanroom Management

Material data sheet. EOS Aluminium AlSi10Mg_200C. Description

The Safety of Personal Hygiene and Beauty Therapy Equipment Used in Commercial Settings

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Hard disk drive mounting bracket Instruction Manual

SpeedLight 2D. for efficient production of printed circuit boards

Analyzing Weather Data

W&H Sterilizers. Made-to-measure precision and perfection. Totally type B

TECHNICAL BRIEF Critical Point Drying

Soil Moisture Estimation Using Active DTS at MOISST Site

MHI s Energy Efficient Flue Gas CO 2 Capture Technology and Large Scale CCS Demonstration Test at Coal-fired Power Plants in USA

Safety Storage Cabinets

Decontamination and Waste Management

Requisite Skills and Abilities for Becoming a Registered Nurse in Alberta

RENEWABLE ENERGY IN EGYPT

Comparison Study of the Growth Promotion Capabilities of Self Contained Biological Indicator Culture Medium in Extended Steam Sterilization Cycles

Handling Freescale Pressure Sensors

Transcription:

3M Sterilization Assurance Products EO Blue bar must enter area Sterile E Online NetworkTutorials EO Blue bar must enter area Understanding the Differences Between Class 5 s and Class 6 Emulating Indicators Version 1.0 EO Blue bar must enter area

Background In December, 2005 the International Organization for Standardization (ISO) published a new document, ISO 11140-1: 2005 Sterilization of healthcare products Indicators Part 1: general requirements. There are two key changes you should be aware of: 1. Class 5 Integrating Indicator requirements were upgraded. 2. Class 6 Emulating Indicators, which were already part of an earlier ISO standard. The remainder of this tutorial will discuss the differences between Class 5 Integrating Indicators and Class 6 Emulating Indicators. By understanding these differences, Sterile Processing professionals can make informed decisions about which Indicator (CI) monitoring devices will provide the most accurate information regarding the sterilization conditions achieved inside a particular pack or load. Key Definitions Understanding the key Indicator terms is critical in understanding the differences in Class 5 Integrating Indicators and Class 6 Emulating Indicators. Definitions are copied out of the ISO 11140 1, in some cases complimented with additional information printed italic. TM Figure 1: Illustration of endpoints moving-front style chemical indicators. Source: 3M internal data TM EO TM TM Resistometer: a specialized test vessel capable of reproducible cycles and used by Manufacturers to characterize the performance of chemical indicators. Blue bar must enter area Stated value (SV): value or values of a critical variable at which the indicator is designed to reach its endpoint as defined by the manufacturer. For example, a Class 5 Integrating Indicator with a stated value of 3.5 minutes at 134 C should reach its endpoint when tested at 134 C for 3.5 minutes in a resistometer (standardized test vessel). Come-Up Time: The time it takes for the sterilizer to achieve the selected exposure temperature. Critical variable: parameters identified as being essential to the sterilization process (and requiring monitoring). Endpoint: point of the observed change as defined by the manufacturer occurring after the indicator has been exposed to specified stated values. For example, the endpoint for a successful cycle for a moving-front style chemical indicator would be the colour bar moving into the accept area (see Figure 1).

Frequently Asked Questions 1. Does the Class number have any significance? For example, is a Class 5 CI better than a Class 4, and is a Class 6 CI better than a Class 5? Today, there are six classes of Indicators. The current ISO document classifies chemical indicators by their intended use and these classifications have no hierarchical significance. For example the Bowie Dick Test is a Class 2 Indicator and probably provides more information about the steam sterilizer performance than any other class of chemical indicators. ISO provides performance requirements for each classification. 2. Are Class 5 and Class 6 CIs designed differently and how do those differences affect my monitoring processes? This design differences are outlined in table 1: Integrading Indicator Time (Min.) 50 20 10 5 2 1 0.5 Integrating Indicator Needs 3 Stated Values ( C, 135 C, and 1 in between) G. stearothermophilus Thermal Death Time 134 Emulating Indicator Time (Min.) 50 20 10 5 2 1 0.5 Emulating Indicators Only Require One Stated Value for Time and Temperature Note: Class 6 response at lower temps can fall below BI thermal death curve G. stearothermophilus Thermal Death Time 134 Design of Class 5 s s. Class 5 Integrating indicators are designed to react to all critical variables (time, temperature, and the presence of steam) and have Stated Values that correlate to a biological indicator (BI) at three time/temperature relationships. Class 5 Integrating indicators must have three Stated Values at C, 135 C, and at one temperature in between that correlate to a BI, e.g. 127 C. Additionally, the Stated Value at C must not be less than 16.5 minutes. This guarantees the time/temperature response for a Class 5 Integrating Indicator will respond like the BI when exposed to ideal, saturated steam (see Figure 2). Therefore, if the exposure temperature was not achieved where the Class 5 CI is located and the BI result was positive (a sterilization failure), the Class 5 CI will respond like the BI performance (thermal death rate curve of G. stearothermophilus) and also indicate that a failure had occurred. Table 1: Class 5 and Class 6 CIs designed differences Design of Class 6 Emulating Indicators Class 6 Emulating indicators are designed to react to all critical variables (time, temperature, and the presence of steam) for a specified sterilization cycle. You may hear Class 6 indicators referred to as cycle specific indicators. Class 6 Emulating indicators have one Stated Value for time and temperature for the specific cycle it is designed for. There is no requirement for three Stated Values for time and temperature and therefore the response may not correlate to a BI. (see Figure 3) Note that at lower temperatures the Class 6 response can fall below that of the BI performance (thermal death rate curve of G. stearothermophilus). (see Figure 3) How does this affect my monitoring processes? If your Sterile Processing Department runs multiple exposure times (e.g. 3, and 18 minutes at 134 C), a distinct Class 6 emulating indicator would be required to monitor each cycle. Because the Class 5 Integrating Indicator response at lower temperatures parallels the biological response, Class 5 CIs are able to detect the failure condition where the desired exposure temperature is not achieved. This condition is likely to occur when there is: incorrect packaging incorrect loading air/steam mixtures an incorrect cycle for load contents. Because the Class 6 response at lower temperatures can fall below the thermal death curve of G. stearothermophilus, the Class 6 Emulating Indicator can reveal a pass when the BI would indicate a failure. Figure 2: Time/Temperature Response for Class 5 Integrating Indicator Compared to Biological Indicator Response. Source: 3M internal test result Figure 3: Time/Temperature Response for Class 6 Emulating Indicator Compared to Biological Indicator Response. Source: 3M internal test result

3. Has 3M completed performance testing of Class 5 CIs and Class 6 CIs in failure conditions? Yes. 3M has tested its Class 5 Integrating indicator and two different Class 6 Emulating Indicators in several different steam sterilization conditions. The data from these studies was used to generate the graphs in Figures 2 and 3 above. The tests were done in a steam resistometer, the special test vessel that generates ideal saturated steam and is the vessel required for ISO Compliance Testing. What this testing revealed is that the 3M Class 5 Integrating Indicators do, in fact, correlate to the biological response or thermal death rate curve of G. stearothermophilus. Even though the Stated Values of the Class 6 Emulating Indicators were 3.5 minutes at 134 C, their time/temperature response compared to the biological response was faster at lower temperatures. 4. Why are resistometers used for testing chemical and biological indicators? 6. What does 3M recommend regarding the use of Class 5 and Class 6 CIs? 3M recommends the use of a Class 5 Integrating Indicator: for internal pack monitoring for process monitoring a Class 6 Emulating Indicator could be used as an internal indicator at the pack/tray level in cycles for which it is labeled This recommendation is based on the following: A Class 5 Integrating Indicator reacts to all critical variables and has three Stated Values that correlate to a BI at three time/temperature relationships (see Figure 1). This means a Class 5 integrating indicator will detect failure conditions where the selected exposure temperature is not achieved. Resistometers are specialized vessels that can create reproducible test cycles. They were chosen by the Standard Committees so manufacturers utilize common reproducible cycles to verify CI and BI performance. There are hundreds of possible hospital cycles where the depth of vacuum, the number of steam/vacuum pulses, the sterilizer come-up time, and the steam quality differ. The cycle specific data for Class 6 Emulating Indicators is generated in a resistometer as well, not in a hospital sterilizer. Therefore, in a hospital sterilizer, Class 6 Emulating Indicators could have significant progression toward their endpoint during the come-up time and reach their endpoint much sooner than their Stated Value time and temperature. Profile of Resistometer Cycle 132 Come-up time (less than 10 sec.) One Vacuum Pulse (Less than 2 minutes) Time Figure 4: Resistometer Cycle Profile Source:3M Internal data These differences would make it impossible to provide consistent CI performance results for hospitals. resistometers must reach the desired temperature in < 10 seconds (see Figure 4). Hospital sterilizers, however, may have up to 10 minutes of pre-conditioning or come-up time (see Figure 6). BI inactivation and CI progression toward endpoint begins to occur during this pre-conditioning or come-up time in hospital sterilizers. The Class 5 Integrating Indicator Stated Value at C must not be less than16.5 minutes. A CI with a Stated Value at C of less than 16.5 minutes can reach its endpoint too quickly at lower temperatures and miss a sterilization process failure. If a load is being released on the results of a Class 5 Integrating Indicator, it is critical the CI be able to show correct results at lower temperatures that is similar with BI performance (see Figure 1). Figure 2 shows how an Emulating Indicator might compare to BI performance in a Resistometer test vessel. Because Emulating Indicators only require one stated value for time and temperature, at lower temperatures the response of a Class 6 Emulating Indicator can fall below the BI thermal death curve.(see Figure 2)

For more Information please call: +49 (0)21 31/14-3000 3M Sterilization Assurance Products Europe c/o 3M Deutschland GmbH Hammfelddamm 11 41453 Neuss, Germany Phone: +49 (0)21 31/14-3000 Fax: +49 (0)21 31/14-4443 www.3m.com 3M is a trademark of the 3M Company 3M 2009. All rights reserved. 1422-101-EU 07/09