MARKING / FCC. Test Report n FCC Rev. 00

Similar documents
FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

RAPPORTO DI PROVA / TEST REPORT

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

TEST REPORT EN (1997) +A1 (2001)

Regulatory requirements - USA

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

TEST REPORT FROM RFI GLOBAL SERVICES LTD

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

Electromagnetic Compatibility Test Report Test results of Floww equipment

Electrified Door Hardware Why Planning for FCC Certification is Key to Success in the Door Hardware Industry

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC File reference No:

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

EMC TEST REPORT For. Webcam. Model Number: CAM67U

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

Test Report #: Date: April 8, 2005

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

Radio Frequency (RF) Exposure Compliance of Radiocommunication Apparatus (All Frequency Bands)

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

Application Note AN-00125

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

Design and Certification of ASH Radio Systems for Japan

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Waveguide Access Point WGA631. Product Guide

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

ST Series POWER SUPPLIES USER INSTRUCTIONS

DATA SHEET DVI - HDCP Extension Cable

NI USB-5681 RF Power Meter Specifications

30 In Compliance October

Declaration of Conformity.

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

Current Probes. User Manual

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

Wireless Base Station Single and Multiple Headsets

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

Draft ETSI EN V1.2.1 ( )

Avaya WLAN 9100 External Antennas for use with the WAO-9122 Access Point

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

Electromagnetic Compatibility and International Regulatory Approvals

Investigation of the Calibration Procedure from CISPR 25, Annex B, for use with Vehicle Component Testing.

5.8GHz Audio/Video Sender

Radiated emission measurement of a cell phone processor module using TEM cell

FCC Part 15C Compliance Test Report

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING)

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

EMC Standards: Standards of good EMC engineering

ACRS 2.0 User Manual 1

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

Dual Chamber Temporary External Pacemaker

Dual-Cool Notebook Cooler Pad. User s Manual

R&S ZNC Vector Network Analyzer Specifications

UNDERSTANDING THE FCC REGULATIONS FOR LOW-POWER, NON-LICENSED TRANSMITTERS

8-Port PoE Network Switch

Declaration of Conformity.

MoCA Adapter MC1001 v2 Installation Guide

NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

Telephone- and leased line modem for industrial applications TD-36

PRO 5000 CPE 1D Quick Installation Guide

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

USER MANUAL. Kramer Electronics, Ltd. Models:

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

One Port Network Analyzer

FIBER OPTIC A/B/C SWITCH (Latching)

USB Port Hub with USB Power Cable. User s Manual

认 证 之 家

No. S8351. S8351 External Bluetooth module for mz series transmitter OPERATING INSTRUCTION

AN3359 Application note

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Scout 1U Rackmount Computer

TEST REPORT No Rev. 0

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Frequency selective monitoring and logging of environmental electromagnetic fields

Antenna Trainer EAN. Technical Teaching Equipment INTRODUCTION

Hear The Future...Now! SIEM-2T/SIEM-2R

Declaration of Conformity.

For the following information

Partial GSM TEST - REPORT

CMP30. User Manual.

Broadband Telecommunications Drop Amplifier

Cond-IS RF Conducted Immunity System

Declaration of Conformity.

CE Test Report. : Microchip Technology Inc West Chandler Blvd., Chandler, Arizona , USA

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

Model 70A00-1. GSM Cellular Communications Center

Laser Wireless Rechargeable Mouse. User s Manual

Transcription:

Laboratories G.S.D. S.r.l. Via Marmiceto, 8-56121 Ospedaletto (Pisa) Italy MARKING / FCC ELECTROMAGNETIC COMPATIBILITY ELECTRICAL SAFETY LASER SPECTROSCOPY ENVIRONMENTAL PHYSICS G.S.D. S.r.l. Laboratori certificati secondo UNI EN ISO 9001:2008 da TÜV Rheinland Italia S.r.l. Certificato N. 39 00 1850509 G.S.D. Srl PISA - Italy Test Report n. 13312-FCC Rev. 00 Applicant / Mailing Manufacturer UR FOG S.r.l. Via Collegno, 11 10143 Torino Italy UR FOG S.r.l. Via Collegno, 11 10143 Torino Italy Test Family Name FAST 02-03 Test Item Name FAST 02 FCC Rules IC RULES Testing Laboratory FCC listed IC Listed Rule Part 15, Subpart B - Unintentional Radiators Class A and B Limits G.S.D. S.r.l. Via Marmiceto, 8-56121 Ospedaletto Pisa (PI) Italy Id nr. 424037 Id nr. 9353A Gentlemen: Enclosed please find your copy of the Test Data Report for the referenced equipment. Please keep the original on record for submission to the FCC, but only if and when they request it. In the event the FCC ever requests this submission, please complete all the documentation requirements, (as per the LIST OF EXHIBITS) before sending. Should you have any questions, please do not hesitate to call. Location and Date of Issue Pisa, 2013 November, 27 Report n. 13312-FCC Rev. 00, page 1 / 18

Laboratories MARKING / FCC ELECTROMAGNETIC COMPATIBILITY ELECTRICAL SAFETY LASER SPECTROSCOPY ENVIRONMENTAL PHYSICS G.S.D. S.r.l. Laboratori certificati secondo UNI EN ISO 9001:2008 da TÜV Rheinland Italia S.r.l. Certificato N. 39 00 1850509 G.S.D. Srl PISA - Italy Test Report n. 13312-FCC Rev. 00 Test Family Name FAST 02-03 Test Item Name FAST 02 Product Family FAST 02, FAST 03 To FCC Rules IC Rules At the request of Attention of Testing Laboratory Federal Communications Commission Rule Part 15, Subpart B - Unintentional Radiators Class A Limits UR FOG S.r.l. Via Collegno,11 10143 Torino Italy UR FOG S.r.l. Via Collegno,11 10143 Torino Italy G.S.D. S.r.l. Via Marmiceto, 8-56121 Ospedaletto Pisa (PI) Italy Tel/Fax +39 050 984254 / +39 050 984262 e-mail: info@gsd.it Date Pisa, 2013 November, 27 Report n. 13312-FCC Rev. 00, page 2 / 18

The applicant has been cautioned as to the following: 15.21 Information to User. The users manual or instruction manual for an intentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 15.27(a) Special Accessories. Equipment marketed to a consumer must be capable of complying with the necessary regulations in the configuration in which the equipment is marketed. Where special accessories, such as shielded cables and/or special connectors are required to enable an unintentional or intentional radiator to comply with the emission limits in this part, the equipment must be marketed with, i.e. shipped and sold with, those special accessories. However, in lieu of shipping or packaging the special accessories with the unintentional or intentional radiator, the responsible party may employ other methods of ensuring that the special accessories are provided to the consumer, without additional charge. Information detailing any alternative method used to supply the special accessories for a grant of equipment authorization or retained in the verification records, as appropriate. The party responsible for the equipment, as detailed in 2.909 of this chapter, shall ensure that these special accessories are provided with the equipment. The instruction manual for such devices shall include appropriate instructions on the first page of text concerned with the installation of the device that these special accessories must be used with the device. It is the responsibility of the user to use the needed special accessories supplied with the equipment. Report n. 13312-FCC Rev. 00, page 3 / 18

Testimonial and Statement of Certification This is to certify that: 1. That the application was prepared either by, or under the direct supervision of, the undersigned. 2. That the technical data supplied with the application was taken under my direction and supervision. 3. That the data was obtained on representative units, randomly selected. 4. That, to the best of my knowledge and belief, the facts set forth in the application and accompanying technical data are true and correct. Report n. 13312-FCC Rev. 00, page 4 / 18

INDEX 1. MANUFACTURER AND EUT IDENTIFICATION...6 2. REFERENCE STANDARDS...8 3. TEST GENERALITY...9 4. CONDUCTED EMISSIONS...11 5. RADIATED EMISSIONS...14 6. PHOTO...17 Report n. 13312-FCC Rev. 00, page 5 / 18

1. MANUFACTURER AND EUT IDENTIFICATION 1 Applicant UR FOG S.r.l. Via Collegno, 11 Italy10143 Torino Mailing UR FOG S.r.l. Via Collegno, 11 Italy10143 Torino EUT Category Unintentional Radiator Test Item Name FAST 02 Manufacturer UR FOG S.r.l. Via Collegno,11 10143 Torino Italy Testing Laboratory G.S.D. S.r.l. Via Marmiceto, 8-56121 Ospedaletto Pisa (PI) Italy Tel/Fax +39 050 984254 / +39 050 984262 e-mail: info@gsd.it Date of reception 2013 November, 07 Date of test 2013 November 13 Sampling Test Item Description Nominal Input Voltage Random From production "Sistema nebbiogeno" 110 Vac 60 Hz 1 A detailed documentation is preserved in the internal fascicle. Report n. 13312-FCC Rev. 00, page 6 / 18

Fig. 1.1 Equipment under test Front view Fig. 1.2 Equipment under test Rear view Report n. 13312-FCC Rev. 00, page 7 / 18

2. REFERENCE STANDARDS Tests and measurements are performed accordingly to the reference standards given in the table below: TEST STANDARD Emissions: Radiated FCC Rules ad Regulations, Title 47 (2008) Part 15 Sub part B ANSI C63.4 American National Standard for Methods of Measuring of Radio-Noise Emissions from Low Voltage Electrical and Electronic Equipment in the Range of 9 khz 40 GHz Emissions: Conducted FCC Rules ad Regulations, Title 47 (2008) Part 15 Sub part B ANSI C63.4 American National Standard for Methods of Measuring of Radio-Noise Emissions from Low Voltage Electrical and Electronic Equipment in the Range of 9 khz 40 GHz Report n. 13312-FCC Rev. 00, page 8 / 18

3. TEST GENERALITY Sub-part 2.1033(b) Test And Measurement Data All tests and measurement data shown were performed in accordance with FCC Rules and Regulations, Volume II; Part 2 and the following individual Parts: 15.109; Unintentional Radiators. Standard Test Conditions and Engineering Practices Except as noted herein, the following conditions and procedures were observed during the testing: In accordance with ANSI C63.4-2004, and unless otherwise indicated in the specific measurement results, the ambient temperature of the actual EUT was maintained within the range of 10 to 40 C (50 to 104 F) unless the particular equipment requirements specify testing over a different temperature range. Also, unless otherwise indicated, the humidity levels were in the range of 10% to 90% relative humidity. Prior to testing, the EUT was tuned up in accordance with the manufacturer's alignment procedures. All external gain controls were maintained at the position of maximum and/or optimum gain throughout the testing. Measurement results, unless otherwise noted, are worst-case measurements. Report n. 13312-FCC Rev. 00, page 9 / 18

Summary of Test Results G.S.D. S.r.l. Via Marmiceto, 8-56121 Ospedaletto (Pisa) Italy Emissions: radiated Section 15.109 Class B Emissions: conducted Section 15.107 Class A TEST RESULT Pass Pass Measurement uncertainty TEST Conducted Emission 50W/50mH AMN (150 khz - 30 MHz) Radiated Emission Semianechoic chamber (30 MHz - 6 GHz) EXPANDED UNCERTAINTY ± 3.5 db ± 4.7 db Environmental Conditions PARAMETER VALUE Temperature (294 ± 3) K Relative humidity (45 ± 5) % Extensions The results refer only to the sampled EUT and under the specified conditions. Report n. 13312-FCC Rev. 00, page 10 / 18

4. CONDUCTED EMISSIONS. Equipment shall meet the limits below when using a CISPR16 quasi-peak and average detector receivers. FREQUENCY RANGE QUASI-PEAK LIMIT AVERAGE LIMIT [db(µv)] (MHz) [db(µv)] 0.5-0.50 79 66 0.50-30 73 60 Test Equipment EQUIPMENT MANUFACTURER MODEL NEXT CALIBRATION EMI Receiver Agilent Technologies N9038A JAN 2014 Transient Limiter HP 11947A JAN 2014 LISN GSD LSN001 JAN 2014 Test procedure: CE22R01 Test method Test method was in accordance with the reference standard. EUT modes of operations were tested in order to achieve the maximum level of emission. Results Graphics in following figures show some registrations of the frequency spectrum of the conducted emissions. Report n. 13312-FCC Rev. 00, page 11 / 18

Job Number Test Name EUT Name 13312-FCC Conducted Emissions FCC 15B UR FOG - FAST02 110V Notes: Phase 1 Report n. 13312-FCC Rev. 00, page 12 / 18

Job Number Test Name EUT Name 13312-FCC Conducted Emissions FCC 15B UR FOG - FAST02 110V Notes: Phase 2 Report n. 13312-FCC Rev. 00, page 13 / 18

5. RADIATED EMISSIONS In the following table you can find the limits established by the reference standard: FREQUENCY RANGE (MHz) Field Strength @3m QUASI-PEAK LIMITS [db (µv/m)] 30 88 40 88 216 43,5 216 960 46 Above 960 54 Test Equipment EQUIPMENT MANUFACTURER MODEL NEXT CALIBRATION EMI Receiver Agilent Technologies N9038A JAN 2014 Semianechoic Room GSD CSC01 JAN 2014 Bilog Antenna Schaffner CBL6112B JAN 2014 LISN GSD LSN01 JAN 2014 Test procedure: RE22R02 Notes Azimuth position EUT-Antenna corresponding to 0 identifies the rotating table orientation (TT) in which the instrument to be tested shows the front part turned towards the antenna. Positive grades individuate clockwise rotations of TT when this one is observed from the top. For negative degrees, TT rotation is anticlockwise. Antenna height respect to the mass plane is conventionally individuated with: MA=XXX where XXX indicates the height (always positive for e>100) expressed in cm. Antenna horizontal polarization is indicated by POL=H. Antenna vertical polarization is indicated by POL=V. Results and conclusions In all the operative conditions, equipment complied with the standard limits. Graphics in following figures show the most significant registrations of the performed measurements. Report n. 13312-FCC Rev. 00, page 14 / 18

Job Number Test Name EUT Name 13312-FCC Radiated Emissions FCC 15B UR FOG - FAST02 110V Notes: POL V MA: 100 cm TT: 0 Report n. 13312-FCC Rev. 00, page 15 / 18

Job Number Test Name EUT Name 13312-FCC Radiated Emissions FCC 15B UR FOG - FAST02 110V Notes: POL H MA: 100 cm TT: 0 Report n. 13312-FCC Rev. 00, page 16 / 18

6. PHOTO Fig. 6.1 Equipment Under Test: Radiated Emissions Test Set-up Report n. 13312-FCC Rev. 00, page 17 / 18

Fig. 6.2 Equipment in conducted emissions test setup Report n. 13312-FCC Rev. 00, page 18 / 18