WAVEFRONT SENSING AND ADAPTIVE OPTICS IN VISIBLE RANGE

Similar documents
Optical modeling of finite element surface displacements using commercial software

Optical laser beam scanner lens relay system

High-resolution imaging of the human retina with a Fourier deconvolution technique

Diffraction of a Circular Aperture

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

Imaging techniques with refractive beam shaping optics

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

Microlenses immersed in nematic liquid crystal with electrically. controllable focal length

Subjective Image Quality Metrics from The Wave Aberration

Optical Standards. John Nichol BSc MSc

MICROFOCUSING OF THE FEL BEAM WITH A K-B ACTIVE OPTICS SYSTEM: SPOT SIZE PREDICTIONS. Lorenzo Raimondi

Accuracy of SpotOptics wavefront sensors. June 2010 Version 4.0

Application Note #503 Comparing 3D Optical Microscopy Techniques for Metrology Applications

ID Objective Requirements Description of Test Date & Examiner 15 Verify that the optics?? OMC

Opto-Mechanical I/F for ANSYS

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Customized corneal ablation and super vision. Customized Corneal Ablation and Super Vision

Analyzing LASIK Optical Data Using Zernike Functions

Optical Systems Design with Zemax OpticStudio. Lecture 1

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

PHYS 39a Lab 3: Microscope Optics

Lecture 12: Cameras and Geometry. CAP 5415 Fall 2010

ABrand New Refraction Meas urement Instrument

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS RAYLEIGH-SOMMERFELD DIFFRACTION INTEGRAL OF THE FIRST KIND

Endoscope Optics. Chapter Introduction

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Adaptive Optics Phoropters

Given ZEMAX's user-interface and available tools, the singlet can be modeled and optimized easily!

Achromatic three-wave (or more) lateral shearing interferometer

Beam shaping to generate uniform Laser Light Sheet and Linear Laser Spots

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Application Report: Running µshape TM on a VF-20 Interferometer

Anamorphic imaging with three mirrors: a survey

Using light scattering method to find The surface tension of water

REPORT DOCUMENTATION PAGE

Laser expander design of highly efficient Blu-ray disc pickup head

The Wide Field Cassegrain: Exploring Solution Space

Plastic Film Texture Measurement With 3D Profilometry

Experimental and modeling studies of imaging with curvilinear electronic eye cameras

Wavefront higher order aberrations in Dohlman/Boston keratoprosthesis and normal eyes

Grazing incidence wavefront sensing and verification of X-ray optics performance

Realization of a UV fisheye hyperspectral camera

A Guide to Acousto-Optic Modulators

Introduction to reflective aberration corrected holographic diffraction gratings

Looking through the fish-eye the Electron Ronchigram. Duncan T.L. Alexander CIME seminar May 24, 2012

Fraunhofer Diffraction

Optical System Design

Automatisierte, hochpräzise Optikmontage Lösungen für die Industrie

Holography 1 HOLOGRAPHY

Introduction to Optics

Understanding astigmatism Spring 2003

Manufacture of 8.4 m off-axis segments: a 1/5 scale demonstration

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Adaptive Optics Testbed for the Visible High Resolution Imaging

HRK-7000 / HRK-7000A Auto Ref-Keratometer

Understanding Laser Beam Parameters Leads to Better System Performance and Can Save Money

Reflection and Refraction

Effect of sampling on real ocular aberration measurements

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

IMPROVING MEASUREMENTS BASED ON THE CAT S EYE RETRO- REFLECTION. Katherine Mary Medicus

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

Diffraction of Laser Light

Helium-Neon Laser. Figure 1: Diagram of optical and electrical components used in the HeNe laser experiment.

YOUR FIRST OSLO SESSION

Since wavefront-sensing techniques were developed

Wir schaffen Wissen heute für morgen

Recommended alignment procedure for Shaper 6_6 / Focal- Shaper 9

Lens refractive index measurement based on fiber point-diffraction longitudinal interferometry

Development of MEMS micromirrors for intracavity laser control

Advances in the measurement of the eye's

Lenses and Apertures of A TEM

Journal of Modern Optics Publication details, including instructions for authors and subscription information:

A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.

Warning : HαT telescope must NOT be used for solar observation without additional filters. This is the user responsibility to check that his filter

Rodenstock Photo Optics

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

View of ΣIGMA TM (Ref. 1)

Physics 441/2: Transmission Electron Microscope

Spatial location in 360 of reference points over an object by using stereo vision

digital quality control fail pass at your fingertips Smart Metrology Solutions.

MEMS mirror for low cost laser scanners. Ulrich Hofmann

Theremino System Theremino Spectrometer Technology

Synthetic Sensing: Proximity / Distance Sensors

Alignement of a ring cavity laser

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

C) D) As object AB is moved from its present position toward the left, the size of the image produced A) decreases B) increases C) remains the same

Refractors Give the Best Planetary Images

Master Anamorphic T1.9/35 mm

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

Color holographic 3D display unit with aperture field division

Zoom Lens Design of Mobilephone Camera with Global-Explorer Optimization

ESRF OPTICAL METROLOGY APPLIED TO BENDABLE OPTICAL SURFACES

Shape Measurement of a Sewer Pipe. Using a Mobile Robot with Computer Vision

Module 13 : Measurements on Fiber Optic Systems

Wavefront technology has been used in our

Customized corneal ablation can be designed. Slit Skiascopic-guided Ablation Using the Nidek Laser. Scott MacRae, MD; Masanao Fujieda

Application-Specific Optical Design

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Transcription:

WAVEFRONT SENSING AND ADAPTIVE OPTICS IN VISIBLE RANGE Pascal Mercère (2,3), Thomas.A. Planchon (1), Gilles Chériaux (1), Jean-Paul Chambaret (1), Philippe Zeitoun (1,2), Xavier Levecq (3), Guillaume Dovillaire (3) (1) - Laboratoire d Optique appliquée, ENSTA - Ecole Polytechnique, Chemin de la Hunière, 91761 Palaiseau Cedex - France (2) - Laboratoire de, Bât. 350, Université Paris-Sud, 91405 Orsay - France (3) - Imagine Optic, 18 rue Charles De Gaulle 91400 Orsay - France Abstract : This paper relates experiences we have recently realised at the. Our aim was firstly to correct a strongly phase-distorded laser beam, secondly estimate the limits of our instruments. The analyses were performed with the Shack-Hartmann wavefront sensor (SHWS) developped by Imagine Optic company. The advantage of using such a sensor leads in the simultaneaous measurement of both intensity distribution and phase distortion of the optical field. Comparison between real focal spot and the one deduced from SHWS measurement shows a good agreement. I - Introduction Currently, SHWS is one of the most well-known and widely used wavefront sensor. It gives in real time highly accurate measurements of both intensity distribution and phase distortion of optical fields. Essential parameters for wavefront analysis, such as Peak-to-Valley (PV), root-mean square (rms), Zernike coefficients and Strehl ratio, can be easily calculated from experimental data. Also its compactness and versatility make this type of sensor readily usable in lots of various optical systems. II - Principle of the Shack-Hartmann wavefront sensor SHWS estimates the wavefront local slopes by sampling many sub-apertures of an incoming beam. This sampling is obtained by using a microlenslet array, which focuses the beamlet onto the sensitive part of a CCD camera (Figure 1). Thus, each sub-aperture of the lenslet array provides its own spot on the CCD camera and the sensor output is a set of {x,y} spot centroid positions (Hartmann pattern). A localy plane - 1 -

wavefront will be focused on the optical axis of the microlens, while a localy tilted one will be focused outside (above or under the axis depending on the tilt angle). So, the local derivative of the wavefront is given by tan(α) = x/f, where α is the tilt angle, x (or y in the other dimension) the distance between the spot centroid position and the optical axis, and f the focal lengh of the microlenses. The whole wavefront is obtained by simple integration of the local slopes. Figure 1: Principle of the Shack-Hartmann wavefront sensor Reconstruction quality depends on the number of microlenses the incident wavefront is decomposed by. Higher this number, more accurate results will be obtained. Of course, the numerical method used for integration is also essential in the experimental data treatment. The wavefront reconstruction is called either zonal or modal, depending on whether the phase is presented like a number of local slopes or in terms of coefficients of a modal function (Zernike polynomials for circular pupils or Legendre polynomials for square pupils). The modal reconstruction is very useful because the coefficients we access to, have a real physical sense and represent the optical aberrations commonly known as tilt, focus, astigmatism or coma. However restrictions subsist. The use of modal reconstruction algorithms implies to work on a particular pupil geometry (the software determines the largest circular or square pupil on the incident wavefront) and the projection onto a finite number of polynomials generates a spatial filtering. III Experimental set-up The experiment was performed with a cw Ti:Sa laser (λ 800nm) pumped by a tunable Argon laser used at λ 500nm. Working parameters were as followed: - Argon pump laser 5.7 W - Ti:Sa laser 1.3 W exit power after optimisation - 2 -

In the first part of the assembly, a spatial filter pinhole (Φ=10µm), placed at focal distance of a focusing lens, generates an incident plane wave with a relatively good wavefront. This plane wave is sent onto the deformable mirror by several plane mirrors, all placed at 45 of the optical axis to infer minimum aberrations. The second part of the setup consists then to realize, by an appropriated lenses conjugation, an image of the deformable mirror plane onto the wavefront sensor pupil (this relay image is essential for keeping the deformable mirror linear characteristic onto the closed loop). The beam is focused by a spherical mirror of 400mm curvature radius, working in an off-axis configuration. A set {half wave plate Glan-Taylor polariser} placed upstream the SHWS enables us to recover a part of the incident beam to focuse it on a CCD camera. The focal spot image made by the CCD camera presents two major interests for our closed loop validation. First, it enables us to follow in real time the correction of the wavefront. Secondly it gives us a reference image of the focal point, to which we can compare the reconstructed image given by the SHWS. The whole experimental setup is represented on Figure 2, and some pictures are given Figure 3. Figure 2 : The experimental setup - 3 -

IV - Results 1 Measurement of the aberrated wavefront After having verified the relay image between the deformable mirror and the sensor pupil, a first measurement of the aberrated wavefront was performed. Figure 4 shows the intensity and phase distribution of the wavefront. We can notice the uniformity of the intensity diagram and the strong aberrations generated by the spherical mirror. Figure 4 : 3D representations of the aberrated wavefront intensity distribution (left) and phase distortion (right) On Figure 5, are given the different values of Zernike coefficients. As we could expected, astigmatism and coma aberrations are dominant. Peak-to-valley and root-mean square are: PV = 6.396 µm rms = 1.162 µm Figure 5 : Zernike coefficients before wavefront correction - 4 -

On the following figure are represented the intensity and phase distributions of the measured wavefront, the corresponding Point Spread Function (PSF), as well as the Strehl ratio calculated in relation to a reference wavefront of same intensity distribution but free of phase distorsions. Strehl ratio, which corresponds to the measured and reference wavefront PSF max ratio, represents the quality of our optical system. It is here 0.03 before correction; so we have got, as wanted, an initially very aberrated wavefront. Figure 6 : Strehl ratio before wavefront correction 2 Wavefront correction The deformable mirror, which the closed loop was realised with, is a BIM31 CILAS bimorph mirror, composed of 31 actuators. The applied tensions can reach +/- 400V. The maximum infered displacement is 20µm peak to valley for defocus mode, which corresponds to a mirror curvature radius of 35m. Its flatness can reach 10nm rms, its rugosity is less than 1nm rms and its reflectivity more than 96% for 0.6µm<λ<15µm. The wavefront obtained after correction is represented below: Figure 7 : 3D representations of the corrected wavefront intensity (left) and phase (right) distributions - 5 -

As we can see on figure 7 and also figure 8, the aberrations of astigmatism and coma infered by the spherical mirror are almost corrected. Only a small amount of higher order aberrations remain. PV and rms are both divided by a factor 20 after correction. PV = 0.297 µm rms = 0.052 µm Figure 8 : Zernike coefficients after wavefront correction Strehl ratio is now 0.85, instead of 0.03 before wavefront correction. (Figure 9) Figure 9 : Strehl ratio after wavefront correction Note : The tensions applied on the deformable mirror different actuators have never exceeded +/- 200V, while the closed loop was working. Tensions up to +/- 400V can be applied. 3 Focal point imaging and Point Spread Function The focal spot image is obtained by using an 8 bits linear CCD camera and a well-adapted microscope objective ( 20 and 40 magnifications were used). - 6 -

Before correction After one iteration Focal point imaging ( 40) Point Spread Function calculated by the SHWS Strehl ratio = 0.03 Strehl ratio = 0.85 Figure 10 : Focal point before and after correction seen by the CCD camera and calculated by the SHWS We can note a very good agreement between the results obtained by the two diagnostics. The dimensions of the focal point after correction are 14,736 µm at 1/e 2 and 7,625 µm at FWHM. Diffraction limit is 7,098 µm. The corresponding 3D representations are given below. Note : Since the CCD image before correction, shown precedently and obtained with a ( 40) microscope objective, is strongly saturated; we prefered to replace it by a non-saturated one obtained with a ( 20) microscope objective. That have to be taken into account for comparative studies of the results! BEFORE CORRECTION AFTER ONE ITERATION CCD image - objective ( 20) CCD image - objective ( 40) - 7 -

V- Conclusion To correct a strongly phase-distorded cw Ti:Sa laser beam, we realised a closed loop with a Shack-Hartmann wavefront sensor and a deformable bimorph mirror. A CCD camera was used to compare the real focal spot with the one deduced from SHWS measurement. The wavefront correction enables us to reduce the PV and rms values by a factor 20 and to increase the Strehl ratio from 0.03 before correction, up to 0.85 after correction. We could also observe a very good agreement between the focal spot images given by the SHWS and the CCD camera. Finaly, we have measured a spot diameter extremely close to the diffraction limit. - 8 -