CONTINUOUS OR INTERMITTENT GLUCOSE MONITORING IN INTERSTITIAL FLUID

Similar documents
Corporate Medical Policy

Medical Benefit Effective Date: 04/01/11 Next Review Date: 01/13 Preauthorization* Yes Review Dates: 07/07, 07/08, 07/09, 01/10, 01/11, 01/12

Medical Coverage Policy Glucose Monitoring Systems sad

Imagine a world... Believe in better control. MiniMed Veo Paradigm System

MEDICAL COVERAGE POLICY. SERVICE: Insulin Pump and Continuous Glucose Monitoring. PRIOR AUTHORIZATION: Required. POLICY:

Basal and Bolus Insulin 7/16/2014. Jackie Aday RN, BSN, CDE Jeni Neighbors RN, BSN, CDE. BASAL: Small amount of insulin infused every few minutes

Medical Policy Insulin Pumps

Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid

The Department of Vermont Health Access Medical Policy

Glucose Monitoring in Interstitial Fluid Diabetes

Insulin Infusion Pumps

Insulin Pump Management and Continuous Glucose Monitoring Systems (CGMS)

Criteria: CWQI HCS-123 (This criteria is consistent with CMS guidelines for External Infusion Insulin Pumps)

Numerous studies have demonstrated that utilization

Alternative method for delivering insulin using continuous subcutaneous insulin infusion (CSII) open loop system

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

FDA Perspective on Closed-Loop Studies

External Insulin Pumps Corporate Medical Policy

Imagine a world... Believe in better control. MiniMed Veo Paradigm System Questions and Answers About Insulin Pumping

CONTINUOUS GLUCOSE MONITORING AND INSULIN DELIVERY FOR MANAGING DIABETES

Insulin Pump Therapy and Continuous Glucose Sensor Use in the Management of Diabetes Mellitus

CONTINUOUS GLUCOSE MONITORING AND INSULIN DELIVERY FOR MANAGING DIABETES

The Quantified Self on Steroids: Innovation in Devices, Pumps and Monitors

Blood Glucose Monitoring Basics

The MiniMed Paradigm Veo System

QUESTION 3. HOW SHOULD THE DATA AND REPORTING BE INTERPRETED?

SEMI-IMPLANTABLE AND FULLY IMPLANTABLE MIDDLE EAR HEARING AIDS

AACE Consensus Statement

Clinical Policy Title: Disposable Continuous Subcutaneous Insulin Infusion Pumps

Insulin Pump Therapy in Australia. The Case for Action

Objectives PERINATAL INSULIN PUMPS: BASICS FOR NURSES. Historical Perspective. Insulin Pumps in Pregnancy. Insulin Pumps in the US

Smart Pumping with Insulin Pumps

Blue Cross Blue Shield of Michigan

Diabetes Self Management Training Insulin Pump Follow Up

EVALUATION OF AUTOMATIC CLASS III DESIGNATION FOR STUDIO on the Cloud Data Management Software DECISION SUMMARY

Get Primed on Pumps: A beginners guide to Insulin Pump Therapy

BRACHYTHERAPY FOR TREATMENT OF BREAST CANCER

4/7/2015 CONFLICT OF INTEREST DISCLOSURE OBJECTIVES. Conflicts of Interest None Heather Rush. Heather M. Rush, APRN, CDE Louisville, KY

Clinical Policy Title: Disposable Continuous Subcutaneous Insulin Infusion Pumps

Challenges in Glycemic Control in Adult and Geriatric Patients. Denyse Gallagher, APRN-BC, CDE Endocrinology Nurse Practitioner

Issues in Emerging Health Technologies

Policy #: 046 Latest Review Date: January 2015 Category: Durable Medical Equipment

Get to know the Animas Vibe insulin pump and CGM * system.

Report of the Automated Control of Insulin Levels Committee

Starting patients on the V-Go Disposable Insulin Delivery Device

Continuous Glucose Monitoring Sensor:

I HAVE JUST BEEN DIAGNOSED WITH TYPE 1 DIABETES

CONVENTIONAL AND DIGITAL HEARING AIDS

Why is Insulin so Important?

MEDICAL POLICY POLICY TITLE DIABETIC SELF-MANAGEMENT TRAINING PROGRAM POLICY NUMBER MP

Blood Sugar Monitoring

Insulin Pump Therapy in children & Adolescents. Dr. Abdulmoein Al-Agha, MBBS,DCH, FRCP(UK) Pediatric Endocrinologist

MiniMed 640G System Intelligent for Better Control

Chapter. CPT only copyright 2009 American Medical Association. All rights reserved. 15Diabetic Equipment and Supplies

The table below logs the history of the steps in development of the document.

CONTINUOUS GLUCOSE MONITORING SYSTEM. Receiver with Share TM USER S GUIDE

The OmniPod Insulin Management System

JDRF Type One Nation Research Summit Diabetes Technology: A Bridge to a Cure

Contacts and Important Information

How to get the most of your blood glucose readings

Causes, incidence, and risk factors

AUTISM SPECTRUM DISORDER TREATMENTS

The Economic Benefit of Public Funding of Insulin Pumps in. New Brunswick

MEDICAL ASSISTANCE HANDBOOK PRIOR AUTHORIZATION OF PHARMACEUTICAL SERVICES

When services are covered 1 2 We cover insulin pumps and insulin pump supplies, in accordance with the Massachusetts Mandate, Chapter 175.

Contractor Information. LCD Information. Local Coverage Determination (LCD): HbA1c (L32939) Contract Number 11202

Algorithms for Glycemic Management of Type 2 Diabetes

CONTINUOUS GLUCOSE MONITORING SYSTEM USER S GUIDE

WHAT CAN I DO TO REDUCE MY RISK OF DEVELOPING THE COMPLICATIONS OF TYPE 1 DIABETES?

Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES

Insulin Pens & Improving Patient Adherence

Insulin Delivery Options: Inhale, Inject, and Infuse. Traci Evans, A.N.P., B.C.-A.D.M. Nurse Practitioner The Diabetes Center Ocean Springs, MS

Supplementary appendix

[ ] POCT glucose Routine, As needed, If long acting insulin is given and patient NPO, do POCT glucose every 2 hours until patient eats.

HEALTH SERVICES POLICY & PROCEDURE MANUAL

Diabetes and Technology. Disclosures Certified Insulin Pump Trainer for: Animas Medtronic Diabetes Omnipod. Rebecca Ray, MSN, APRN, FNP-C

Clinical Policy Title: Insulin Infusion Therapy (Insulin Pumps)

Clinical and cost-effectiveness of continuous subcutaneous insulin infusion therapy in diabetes.

BOLUS INSULIN DOSAGES H. Peter Chase, MD and Erin Cobry, BS

OmniPod. Extension. for the CoPilot Health Management System. Version 1.1. For use with PDM model UST200

Taking Insulin Pumps to School. Rachel Calendo, MS, RN, CPNP, CDE, Martha Cuevas, RN, BSN, CPT

tips Insulin Pump Users 1 Early detection of insulin deprivation in continuous subcutaneous 2 Population Study of Pediatric Ketoacidosis in Sweden:

Real-Time Improvement of Continuous Glucose Monitoring Accuracy

NUVIGIL (armodafinil) oral tablet

SCHOOL DISTRICT #22 VERNON DIABETES POLICY

Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES

1 of 44 07/06/ :29 AM

Insulin Delivery and Glucose Monitoring Methods: Future Research Needs

A Reference Guide for School Nurses. with the Medtronic MiniMed Insulin Pump

Insulin therapy in various type 1 diabetes patients workshop

The Economic Benefit of Public Funding of Insulin Pumps in Prince Edward Island

For people with diabetes. A blood sugar diary

Insulin Pump Therapy

The Basics of Insulin Pump Therapy

FORWARDHEALTH PRIOR AUTHORIZATION / PREFERRED DRUG LIST (PA/PDL) FOR HYPOGLYCEMICS, INSULIN LONG-ACTING

Diabetes in the Long Term Care Setting: Advantages of Basal Insulin Therapy and Insulin Pen Devices

reviewed to determine patients who actually started on this therapy.

Diabetes mellitus 1 عبد هللا الزعبي. pharmacology. Shatha Khalil Shahwan. 1 P a g e

Prior Authorization Guideline

Use of Continuous Subcutaneous Insulin Infusion (CSII) Pumps in Hospitalized Patients Policy and Procedure

Transcription:

FLUID Coverage for services, procedures, medical devices and drugs are dependent upon benefit eligibility as outlined in the member's specific benefit plan. This Medical Coverage Guideline must be read in its entirety to determine coverage eligibility, if any. The section identified as Description defines or describes a service, procedure, medical device or drug and is in no way intended as a statement of medical necessity and/or coverage. The section identified as Criteria defines criteria to determine whether a service, procedure, medical device or drug is considered medically necessary or experimental or investigational. State or federal mandates, e.g., FEP program, may dictate that any drug, device or biological product approved by the U.S. Food and Drug Administration (FDA) may not be considered experimental or investigational and thus the drug, device or biological product may be assessed only on the basis of medical necessity. Medical Coverage Guidelines are subject to change as new information becomes available. For purposes of this Medical Coverage Guideline, the terms "experimental" and "investigational" are considered to be interchangeable. BLUE CROSS, BLUE SHIELD and the Cross and Shield Symbols are registered service marks of the Blue Cross and Blue Shield Association, an association of independent Blue Cross and Blue Shield Plans. All other trademarks and service marks contained in this guideline are the property of their respective owners, which are not affiliated with BCBSAZ. Description: Glucose monitoring of the interstitial fluid is a technique of automatically measuring glucose levels throughout the day to provide trends in glucose measurements, in contrast to traditional isolated blood glucose levels. Information on trends in glucose levels may benefit individuals with type I diabetes that have inadequate control, including episodes of hypoglycemia, despite compliance with best practices. O388.19.docx Page 1 of 11

Description: (cont.) Best Practices: 4 or more fingersticks per day and use of an insulin pump During pregnancy, 3 or more insulin injections per day for individuals not on an insulin pump prior to the pregnancy Prior use of an intermittent (72-hour) glucose monitor for individuals considering use of a continuous glucose monitor FDA Approved Devices Include: CGMS ipro Continuous Glucose Recorder System: The CGMS ipro digital recorder is attached to a tiny glucose sensor inserted just under the skin to continuously record interstitial glucose levels over three days. After the recording period is complete, the device is removed and the information collected is downloaded, using the comlink ipro, the solutions software and a personal computer to generate a detailed glucose report. This information may help the health care provider identify patterns of glucose level excursions above or below the desired range to facilitate therapy adjustments. The information is intended to supplement, not replace, blood glucose information obtained using a standard home glucose-monitoring device. Dexcom STS Continuous Glucose Monitoring System: A temporary sensor is implanted in the subcutaneous tissue which measures glucose levels continuously and transmits them wirelessly to the receiver. The receiver can display results in real time or show trends over a period of time as well as alerting the user to high or low readings. The sensor is replaced every three days. Dexcom STS-7 Continuous Glucose Monitoring System: A temporary sensor is implanted in the subcutaneous tissue which measures glucose levels continuously and transmits them wirelessly to the receiver. The receiver can display results in real time or show trends over a period of time as well as alerting the user to high or low readings. The sensor is replaced every seven days. The STS-7 Continuous Glucose Monitoring System is a glucose sensor which reports glucose values every 5 minutes for up to 7 days before a new sensor must be inserted. DexCom G4 Platinum Continuous Glucose Monitoring System: The system includes three components: a sensor, transmitter and receiver. The glucose sensor is a small wire that is inserted under the skin of the abdomen and measures glucose values in the fluid between the body s cells (interstitial fluid). The glucose values are sent through the transmitter to the hand-held receiver, where they are displayed for the user. GlucoWatch G2 Biographer: GlucoWatch is worn like a wristwatch. It measures glucose in the interstitial fluid that is extracted through the skin with an electric current (referred to as reverse iontophoresis). Measurements are made every 5 to 10 minutes. O388.19.docx Page 2 of 11

Description: (cont.) Guardian Continuous Glucose Monitoring System: The Guardian System is an upgraded version of the MiniMed CGMS. It is implanted in the subcutaneous tissue and utilizes a glucose sensor to continuously record interstitial glucose readings for up to three days. These glucose readings are transmitted to the monitor, which is designed to sound an alarm when glucose levels reach high or low limits preset by the individual or his/her healthcare provider. Information from the monitor is downloaded to a computer for additional trend analysis to further improve diabetes care. The system requires calibration a minimum of twice a day using a discrete blood glucose meter. Guardian-RT Continuous Glucose Monitoring System: Continuously or periodically monitors glucose levels in fluid under the skin and provides real-time glucose values. System alerts if glucose level falls outside preset values. Stores data for trending and analysis. MiniMed Continuous Glucose Monitoring System (CGMS): A temporary sensor is implanted in the subcutaneous tissues of the abdomen. The sensor converts glucose from the interstitial fluid into an electric signal. Measurements are made every 5 minutes. The upgrade version is called the Guardian CGMS. MiniMed Paradigm REAL-Time Insulin Pump and Continuous Glucose Monitoring System: System that integrates the MiniMed Paradigm 522 or 722 insulin pump with continuous glucose monitoring in one device. The REAL-Time continuous glucose monitoring component, an optional separate purchase from the insulin pump, displays REAL-Time glucose readings every five minutes, 3 and 24-hour glucose trend graphs; and alarms when blood sugar levels fluctuate too high or too low. The integrated calculator Bolus Wizard computes a recommended insulin dosage. OmniPod Insulin Management System: OmniPod is a small disposable external insulin pod that is filled with insulin and infused through a cannula based on instructions programmed into its wireless companion, the Personal Diabetes Manager (PDM). The PDM integrates blood glucose results into bolus calculations, eliminating the need to carry a separate blood glucose meter. The pod is replaced approximately every three days. The unit is considered an alternative to a standard insulin infusion pump. Artificial Pancreas or Artificial Pancreas Device Systems (APDS): The proposed artificial pancreas is a series of devices e.g., a CGM, blood glucose device and an insulin pump, plus a computer algorithm that communicates with all of the devices. The goal of the APDS is to automatically monitor glucose levels and adjust insulin levels. These systems are also referred to as closed-loop systems or autonomous systems for glucose control. One technology associated with artificial pancreas development is a low glucose suspend (LGS) feature included with an insulin pump. The LGS feature is designed to suspend insulin delivery when plasma glucose levels fall below a pre-specified threshold. O388.19.docx Page 3 of 11

Description: (cont.) MiniMed 530G System: Integrates an insulin pump and glucose meter, and including a threshold suspend feature, was cleared for marketing in September 2013. The threshold suspend tool temporarily suspends insulin delivery when the sensor glucose level is equal to or lower than a pre-set threshold within the 60 mg/dl to 90 mg/dl range. When the glucose value reaches this threshold, an alarm sounds. If individuals respond to the alarm, they can choose to continue or cancel the insulin suspend feature. If individuals fail to respond to the alarm, the pump automatically suspends action for 2 hours, and then insulin therapy resumes. The device is approved only for use in individuals 16 years and older. Criteria: Intermittent Glucose Monitoring (up to 72 hours): If medical necessity criteria are met, any FDA-approved CGM device is eligible for coverage. Intermittent monitoring of glucose levels in the interstitial fluid is considered medically necessary for an individual with type I diabetes to determine baseline insulin levels prior to insulin pump initiation. Intermittent monitoring of glucose levels in the interstitial fluid is considered medically necessary for an individual with type I diabetes that is poorly controlled despite use of best practices (see Description section) with documentation of ANY of the following: 1. Diabetic ketoacidosis, recurrent 2. Hypoglycemic unawareness 3. Suspected postprandial hyperglycemia 4. Unexplained hypoglycemic episodes O388.19.docx Page 4 of 11

Criteria: (cont.) Continuous Glucose Monitoring: If medical necessity criteria are met, any FDA-approved CGM device is eligible for coverage. Continuous monitoring of glucose levels in the interstitial fluid is considered medically necessary with documentation of ANY of the following despite use of best practices (see Description section): 1. Individual with type I diabetes who has recurrent unexplained severe hypoglycemia (blood glucose levels less than 50mg/dl) for whom the hypoglycemia puts the individual or others at risk 2. Pregnant individual with type I diabetes that is poorly controlled with documentation of ANY of the following: 1. Diabetic ketoacidosis, recurrent 2. Hypoglycemic unawareness 3. Suspected postprandial hyperglycemia 4. Unexplained hypoglycemic episodes If medical necessity criteria are met, any FDA-approved CGM device is eligible for coverage. Continuous monitoring of glucose levels in the interstitial fluid in combination with an external insulin infusion pump in an individual 7 years of age or older with type I diabetes is considered medically necessary with documentation of recurrent unexplained severe hypoglycemia and ALL of the following: 1. Hemoglobin A1c (HbA1c) > 8 2. Hypoglycemia puts the individual or others at risk 3. Use of best practices (see Description section) does not resolve the recurrent hypoglycemia Continuous monitoring of glucose levels in the interstitial fluid alone or in combination with an external insulin infusion pump for all other indications not previously listed is considered experimental or investigational based upon: 1. Insufficient scientific evidence to permit conclusions concerning the effect on health outcomes, and 2. Insufficient evidence to support improvement of the net health outcome, and 3. Insufficient evidence to support improvement of the net health outcome as much as, or more than, established alternatives. O388.19.docx Page 5 of 11

Criteria: (cont.) Continuous Glucose Monitoring: (cont.) Arizona statutory coverage mandates do not require coverage of continuous glucose monitoring devices unless medically necessary. 4 Although rental of the device is not eligible for coverage, the professional services for consultation and review of data are eligible for coverage as evaluation and management (E/M) services with appropriate documentation. Artificial Pancreas or Artificial Pancreas Device Systems (APDS): Use of an artificial pancreas system, including but not limited to closed-loop monitoring devices with low-glucose suspend (LGS) features, is considered experimental or investigational based upon: 1. Insufficient scientific evidence to permit conclusions concerning the effect on health outcomes, and 2. Insufficient evidence to support improvement of the net health outcome, and 3. Insufficient evidence to support improvement of the net health outcome as much as, or more than, established alternatives, and 4. Insufficient evidence to support improvement outside the investigational setting. Resources: 1. 1.01.20 BCBS Association Medical Policy Reference Manual. Continuous or Intermittent Monitoring of Glucose in the Interstitial Fluid. Re-issue date 03/13/2014, issue date 08/18/2000. 2. American Association of Clinical Endocrinologists (AACE). Statement by the American Association of Clinical Endocrinologists Consensus Panel on Continuous Glucose Monitoring. Endocrine Practice. 2010;16(5). 3. American Diabetes Association. Executive Summary: Standards of Medical Care in Diabetes 2010. Diabetes Care. January 2010;33(Supplement I):S4-S10. O388.19.docx Page 6 of 11

Resources: 4. Arizona Revised Statutes. Annotated sections 20-828, 20-1057, and 20-2325. 5. BCBS Association Technology Assessment Program. Use of Intermittent or Continuous Interstitial Fluid Glucose Monitoring in Patients With Diabetes Mellitus. December 2003;18(16). 6. Bergenstal RM, Tamborlane WV, Ahmann A, et al. Effectiveness of sensor-augmented insulinpump therapy in type 1 diabetes. N Engl J Med. 2010 Jul 22;363(4):311-320. 7. California Technology Assessment Forum. Continuous Glucose Monitoring in Patients with Diabetes Mellitus on Insulin. Blue Shield of California Foundation. 03/11/2009. 8. Centers for Medicare & Medicaid Services. Continuous Glucose Monitoring (A28892). 2007. 9. Centers for Medicare & Medicaid Services (CMS) Public Agenda Payment and Coding Determinations for Durable Medical Equipment (DME). HCPCS Request #06.102. April 25, 2006. 10. Davis SN, Horton ES, Battelino T, Rubin RR, Schulman KA, Tamborlane WV. STAR 3 randomized controlled trial to compare sensor-augmented insulin pump therapy with multiple daily injections in the treatment of type 1 diabetes: research design, methods, and baseline characteristics of enrolled subjects. Diabetes Technol Ther. Apr 2010;12(4):249-255. 11. Deiss D, Bolinder J, Riveline JP, et al. Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring. Diabetes Care. 2006 Dec;29(12):2730-2732. 12. Hermanides J, Norgaard K, Bruttomesso D, et al. Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial. Diabet Med. Oct 2011;28(10):1158-1167. 13. Meade LT. The use of continuous glucose monitoring in patients with type 2 diabetes. Diabetes Technol Ther. Feb 2012;14(2):190-195. 14. Slover RH, Welsh JB, Criego A, et al. Effectiveness of sensor-augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study. Pediatr Diabetes. Feb 2012;13(1):6-11. O388.19.docx Page 7 of 11

Resources: (cont. 15. TEC-Medical Policy Clearinghouse News. Continuous Glucose Monitoring System. May 15, 2006. FDA Premarket Approval Database for Continuous Glucose Monitoring System (MiniMed): - FDA-approved indication: To continuously record interstitial glucose levels in persons with diabetes mellitus. To supplement, not replace blood glucose information obtained using standard home glucose monitoring devices. FDA Premarket Approval Database for Guardian Continuous Glucose Monitoring System: - FDA-approved indication: For continuous or periodic monitoring of interstitial glucose values in persons with diabetes mellitus. Glucose values calculated by the device will be used to trigger hypo- and hyperglycemia alerts but glucose values will not be displayed. Up to 21 days of stored data can be downloaded to a personal computer to identify patterns and optimize diabetes management. FDA Premarket Approval Database for Guardian-RT Continuous Glucose Monitoring System: - FDA-approved indication: For continuous or periodic monitoring of glucose levels in the fluid under the skin in adults (ages 18 and older) with diabetes mellitus for the purpose of improving diabetes management. It alerts if a glucose level falls below or rises above preset values. Values are not intended to be used directly for making therapy adjustments, but rather to provide an indication of when a finger stick may be required. All therapy adjustments would be based on measurements obtained using a home glucose monitor and not on guardian values. Guardian RT provides real-time glucose values that allow users to track patterns in glucose concentrations and to possibly identify episodes of low and high blood glucose episodes. It also stores the data so that it can be analyzed to track patterns. Glucose data can be further downloaded to pc software for analysis of historical glucose. O388.19.docx Page 8 of 11

Resources: (cont.) FDA Premarket Approval Database for GlucoWatch G2 Biographer: - FDA-approved indication: For detecting trends and tracking patterns in glucose levels in adults (age 18 and older) and children/adolescents (age 7 to 17) with diabetes. For use at home and in health care facilities. The device is for prescription use only. For use as an adjunctive device to supplement, not replace, information obtained from standard home glucose monitoring devices. For use in the detection and assessment of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments, which may minimize these excursions. Interpretation of Biographer results should be based on the trends and patterns seen with several sequential readings over time. FDA Premarket Approval Database for Dexcom STS Continuous Glucose Monitoring System: - FDA-approved indication: 1) For detecting trends and tracking patterns in adults (18 and older) with diabetes and is intended for use by patients at home and in health care facilities. The device is for prescription use. 2) For use as an adjunctive device to complement, not replace, information obtained from standard home glucose monitoring devices. 3) Aids in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments, which may minimize these excursions. Interpretation of the STS system results should be based on the trends and patterns seen with several sequential sensor readings over time. FDA Premarket Approval Database for Dexcom STS-7 Continuous Glucose Monitoring System: - FDA-approved indication: For detecting trends and tracking patterns in adults (age 18 and older) with diabetes. The sts-7 system is intended for use by patients at home and in health care facilities. The device is for prescription use only. The sts-7 continuous glucose monitoring system is indicated for use as an adjunctive device to complement, not replace, information obtained from standard home glucose monitoring devices. The sts-7 continuous glucose monitoring system aids in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments, which may minimize these excursions. Interpretation of the sts-7 system results should be based on the trends and patterns seen with several sequential readings over time. O388.19.docx Page 9 of 11

Resources: (cont.) FDA Premarket Approval Database for Paradigm REAL-Time Insulin Pump and Continuous Glucose Monitoring System: - FDA-approved indication: Approval for modifications to the 515/715 external insulin pump and to the guardian sensor to enable the pump to accept data from the sensor and to enable the sensor to communicate directly to the pump. FDA Premarket Approval Database for CGMS ipro System: - FDA-approved indication: The device is intended to continuously record interstitial glucose levels in persons with diabetes mellitus. The information is intended to supplement, not replace, blood glucose information obtained using a standard home glucose-monitoring device. FDA Premarket Approval Database for FreeStyle Navigator CGM System: - FDA-approved indication: For continually recording interstitial fluid glucose levels in people (ages 18 and older) with diabetes mellitus for the purpose of improving diabetes management. Readings and alarms about glucose levels from the freestyle navigator continuous glucose monitoring system are not intended to replace traditional blood glucose monitoring. Before adjusting therapy for diabetes management based on the results and alarms from the freestyle navigator continuous glucose monitoring system, traditional blood glucose tests must be performed. The freestyle navigator continuous glucose monitoring system provides a built-in blood glucose meter to confirm the continuous glucose result. The freestyle navigator continuous glucose monitoring system provides real-time readings, graphs, trends and glucose alarms directly to the user. The freestyle navigator continuous glucose monitoring system is intended to be used in home settings to aid people with diabetes in predicting and detecting episodes of hypoglycemia and hyperglycemia and in clinical settings to aid healthcare professionals in evaluating glucose control. The freestyle navigator continuous glucose monitoring system is available only by prescription O388.19.docx Page 10 of 11

Resources: (cont.) FDA Premarket Approval Database for Guardian Real-Time and Paradigm Real-Time Systems: - FDA-approved indication: The guardian real-time system is indicated for continuous or periodic monitoring of glucose levels in the fluid under the skin, in adults, age 18 and over, and in children and adolescents, age 7 to 17, with diabetes mellitus, for the purpose of improving diabetes management. It alerts if a glucose level falls below, or rises above, preset values. Values are not intended to be used directly for making therapy adjustments, but rather to provide an indication of when a fingerstick may be required. All therapy adjustments should be based on measurements obtained using a home glucose monitor. The system provides real-time glucose values that allow users to track patterns in glucose concentrations and to possibly identify episodes of low and high blood glucose. It also stores the data so that it can be analyzed to track patterns. Glucose data can be further downloaded to pc software for analysis of historical glucose values. The paradigm real-time system is indicated for continuous or periodic monitoring of glucose levels in the fluid under the skin, and possible low and high blood glucose episodes in adults, age 18 and over, and in children and adolescents, age 7 through 17. The system provides an alert if glucose levels fall below or rise above preset values. Glucose values provided by the system are not intended to be used directly for making therapy adjustments, but rather to provide an indication of when a fingerstick may be required. All therapy adjustments should be based on measurements obtained using a home glucose monitor and not on sensor glucose readings provided by the paradigm real-time system. O388.19.docx Page 11 of 11