ellk/m 92 LED 400/800

Similar documents
2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Brochure. Light fittings, floodlights and beacons New LED range for hazardous areas

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Linear Luminaire with LED Series EXLUX 6402/2

A good connection. International approvals.

DuroSite TM High Bay Lighting

Floodlight Range Installation Guide

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Plug and Socket Devices CES 63 A Series 8579

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

Series 8146/5-V37 and Series 8150/5-V37

Terminal Boxes Series 8146

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

Flameproof Audible Signal 115 db (A) Series YA90

Abtech Custom Solutions

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Plug and Socket Devices SolConeX 16 A Series 8570

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Why Philips LEDtube? LED Lamps EMEA February February 2015_BG LS & E LEDlamps

Technical Specifications

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Operating Instructions

Compact pressure switch Flameproof enclosure Ex d Model PCA

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

9W T8 LED TUBE 2FT GENERAL INFORMATION

Emergency Light Fittings

Redundancy Module QUINT-DIODE/40

Digital inductive conductivity transmitter

7 Lighting Technology

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

5YR. Advanced LED lighting. High performance industrial lighting. 50% energy against traditional fittings Up to 75% energy saving with sensing

Electric Rotary Actuator - On/Off or programmable control actuator

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

Led lighting products

SkyBay LED Low & High Bay 1

Explosion proof enclosures

Features. High Brightness LED Light source

LED High Bay Light 100W

Control and Distribution Boxes made of Stainless Steel Series 8150

The purpose of industrial lighting is to enable quick and accurate work, safely, and in a good visual environment. Points of note are:

LED Retro Fit the next generation in energy efficiency. Converting existing 12v systems to LED

Infrarot-Bewegungsmelder IP44

Why Philips LEDtube? Leander Bloot Product marketing LEDtubes LED Lamps EMEA January January 2014_BG LS & E LEDlamps

REVO-LB. REVO LB (Low Bay Industrial Luminaires)

Technical data sheet TDS0070

Instructions for Safe Use

Inductive sensor NI10-M18-Y1X-H1141

CompactLogix Power Supplies Specifications

T5 LongLast. GE Lighting DATA SHEET

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

LIGHTING and LIGHTING SYSTEMS

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

Light First Social innovation through lighting

KATO. LED Lighting High Bay und Low Bay

Vigilant LED High Bay for Indoor and Outdoor Industrial Applications

SITRANS F flowmeters SITRANS F M

PPL Electric Utilities Energy Efficiency and Conservation Program

4/2-Way Pneumatic Solenoid Valve

Superlight Compact Nano

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

MiLed Fixed Compact recessed luminaire

120W High Bay II Datasheet

T8 1200mm LED Tube 18 W FICHA TÉCNICA (1/5)

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

Rittal TopTherm fan-and-filter unit

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).

Terminal Box. Specifications TNCN

Innovative. Lum. Flux** [lm]

DMX LED Street Lights - LU1 Page 1 of 5

Pluggable interface relays CR-P Pcb relays

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

LED Tubular Lamp / Kit Guide

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

induction lighting toll free: tel: fax:

Universal Fibre Optics L E D L I G H T S O U R C E S

3DLevelScanner II TECHNICAL DATA SHEET

DuroSite TM. Series LED High Bay Brochure. for Industrial & Commercial Applications.

AOK i Series LED High Bay / Flood / Tunnel Light

GE Lighting. Lighting the future. Your guide to changing to energy efficient lamps

Emergency lighting units EM powerled

Worcester DS/DM Series UltraSwitch Switch box

RM4TG20 three-phase network control relay RM4-T - range V

Evolve LED Roadway Lighting

LightingEurope EU Compliant Requirements Products Sheets for LIGHTING COMPONENTS

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Control- and feedback head for integrated mounting on Robolux valves Type 2036

The most sustainable lighting solution. QL 85W Induction Lighting System

T5 Watt-Miser Linear Fluorescent lamps

Operating instructions IV / 2007

Metal Halide Pulse Start vs. Probe Start. By Dick Erdmann GE Specification Engineer

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Session 15 Lighting Fundamentals

Transcription:

ellk/m 92 LED 4/8 Explosion-protected Linear LED Light Fitting for Zone 1 and 21

LINEAR LED LIGHT FITTING NEW - linear LED Module for ellk/m 92 Series Cooper Crouse-Hinds has designed a revolutionary module with LED light source to fit into existing ellk/m 9218/18 and ellk/m 9236/36. This converts a traditional fluorescent light fitting into an LED light. The LED module allows also a retrofit of already installed ellk/m 92 with the latest generation electronic ballast (EVG 9). A special designed reflector system prevents disability glare at low mounting heights. This also directs the light output of the high power LED chips to the working area respective measuring plane avoiding multi shadowing and light pollution. The LED system design and certification allows the use in the well proven Ex e technology of ellk/m 92. With the use of our electronic ballast EVG 9 as the driver we can refer to 2 years successful operation in harsh and hazardous environments. The advantages of the LED Module: Environmental friendly, no mercury Shock and vibration resistant, no filament or glass to break Immediate start, instant full illumination No life time reduction due to switching cycles Reduced disposal costs Energy and cost savings 2% energy savings compared to fluorescent lamps Additional energy savings by operating on demand (Night-/day and presence-mode) Reduced maintenance costs compared to standard fluorescent lamps Lower overall cost of ownership Operating life Expected operating life of a Cooper Crouse-Hinds LED module is 6, hours. This is a significant upgrade over traditional light sources. Heat sinks are specifically engineered to remove heat from the LEDs to ensure longer life, better lumen output and accurate colour temperature. Fully operational with CG-S modules for connection to CEAG central battery emergency lighting systems. Can be retrofit into existing light fitting type ellk/m 92 18/18 or ellk/m 9236/36 (latest version) Energy savings 2 % compared to fluorescent versions Special reflector design with indirect light output to avoid disability glare and multi shadowing Well-proven driver technology of the used EVG 9 for more than 2 years Selected LED chips with perfect binning, low power dissipation and long life span Ex-e technoloy for easy maintenance For environmental temperatures from -25 C up to + C 2 Cooper Crouse-Hinds GmbH

ellk/m 92 LED 4/8 LED 4 module ellk 92 LED 4 Technical Data ellk/m 92 LED 4 / ellk/m 92 LED 8 Marking to 94/9/EC II 2 G Ex d e mb IIC T4 Gb II 2 D Ex tb IIIC T8 C Db IP66 EC-Type Examination Certificate BVS 9 ATEX E 34 IECEx-Certification of conformity IECEx BVS 9.33 Marking to IECEx Ex d e mb IIC T4 Gb/ Ex tb IIIC T8 C Db Rated voltage 11-254 V AC, 11-25 V DC Frequency 5/6 Hz Permissable ambient temperature 25 C up to + C Lifetime L 7 = 6, h at ta = 25 C Power factor cos >.95 Driver EVG 9 Connecting terminals L1, L2, L3, N, PE; max. 2 x 6 mm² per terminal Insulation class I Light colour 4 K CRI > Iluminance at measurement plane equivalent to related fluorescent tubes Degree of protection accd. EN 6529 IP 66 Cable glands/gland plates/enclosure drilling Ex-e cable glands M25 x 1.5 (plastic) for cables Ø 8-17 mm Option: M2 x 1.5 metal thread Enclosure material Glass fibre reinforced polyester Protective cover/protective bowl Polycarbonate ellk/m 92 LED 4 ellk/m 92 LED 8 Rated current. A.25 A Lamp/Illuminant LED module 2 x 13 W LED module 2 x 26 W Dimensions (L x W x H) 76 x 188 x 13 mm 136 x 188 x 13 mm Weight 6.9 kg 1.7 kg LED Module LED 4 LED 8 Marking to 94/9/EC II 2 G Ex e mb IIC Gb II 2 G Ex e mb IIC Gb EC-Type Examination Certificate BVS 13 ATEX E 18 U BVS 13 ATEX E 18 U Marking to IECEx Ex e mb IIC Gb Ex e mb IIC Gb IECEx-Certification of conformity IECEx BVS 13.3 U IECEx BVS 13.3 U Dimensions to fit into ellk/m 92 18/18 to fit into ellk/m 92 36/36 Weight 1.7 kg 3.3 kg Cooper Crouse-Hinds GmbH 3

LINEAR LED LIGHT FITTING LED 4 module ellk 92 LED 4 ellk 92 LED 8 ellm 92 LED 8 ellm 92 LED 4 Ordering details Type Terminals Through-wiring Cable glands 2 ) Plugs Order No ellk 92 LED 4 single-ended double-ended 1/6-1 1 x 6 x - 2 x M25 x 1.5 1 x blanking 1 2265 5 11 2/6-2 2 x 6 - x 2 x M25 x 1.5 2 x threated 1 2265 5 13 1/6-1 M 1 ) 1 x 6 x - 2 x M2 x 1.5 1 x threated 1 2265 5 19 2/6-2 M 1 ) 2 x 6 - x 4 x M2 x 1.5 2 x threated 1 2265 5 111 ellm 92 LED 4 1/6-1 1 x 3 - - 1 x M25 x 1.5 1 2268 5 11 ellk 92 LED 8 1/6-1 1 x 6 x - 2 x M25 x 1.5 1 x blanking 1 2266 5 11 2/6-2 2 x 6 - x 2 x M25 x 1.5 2 x threated 1 2266 5 13 1/6-1 M 1 ) 1 x 6 x - 2 x M2 x 1.5 1 x threated 1 2266 5 19 2/6-2 M 1 ) 2 x 6 - x 4 x M2 x 1.5 2 x threated 1 2266 5 111 ellm 92 LED 8 1/6-1 1 x 3 - - 1 x M25 x 1.5 1 2269 5 11 LED Module LED-Module 4 for ellk/m 92 18/18, packed 1 2255 213 51 LED-Module 8 for ellk/m 92 36/36, packed 1 2256 226 51 1) M: with metal thread, without cable gland 2) With dustcover if entry/thread is not closed Scope of delivery without fixing accessories. Dimension drawing 3.5 13 W = 732 26 W = 1332 M25 x 1.5 13 W = 4 26 W = 7 hexagon A/F 13 M8, 14 deep 188 46 65 13 ellk 92 LED 4/8 13 W = 76 26 W = 136 Hexagon A/F 13 ellm 92 LED 8 736 = 13 W 1336 = 26 W 16 = 13 W 166 = 26 W Hexagon A/F 13 ellm 92 LED 4 188 44 76 13 33 33 2 ellm 92 LED 4/8 33 4 Cooper Crouse-Hinds GmbH

ellk/m 92 LED 4/8 LED 4 module ellk 92 LED 4 ellk 92 LED 8 ellm 92 LED 8 ellm 92 LED 4 Polar curve Polar curve ellk/m 92 LED 4 Polar curve ellk/m 92 LED 8 9 9 9 9 125 25 25 5 6 3 6 6 6 C C9 3 5 625 3 l/cd C C9 3 1 125 3 l/cd 1,,5 2, 6 m 2, 1, 6 m,5 4 4 5, ISO-Lux diagram ellk 92 LED 4 mounting height: 6 m maintenance factor:.8 5, 2 2 2, 1 2,,5 1 1, 1,,5-2 5, -2 1 5, -4-4 5, -6 2, 2, 1,,5-6 -1 m,5 1, 2, -8-6 -4-2 2 4 6 8 1 m Cooper Crouse-Hinds GmbH 5

OVERVIEW LED LIGHTING High power LED technology from Cooper Crouse-Hinds Leading the way in LED technology for hazardous area lighting Cooper Crouse-Hinds offers a broad portfolio of LED luminaires for any hazardous or industrial applications Robust construction ensures highest safety and reliability suitable for application indoors/outdoors for the harshest environments Perfectly combining safety, reliability and energy efficiency Refinery Heavy Industry Chemical plants Designed for hazardous applications Offshore Optimal LED quality Shock- and vibration- resistant solid-state devices have no filaments or glass components that could break, greatly reducing the risk of premature failure No UV or IR radiation: Immediate start, provides instant and full illumination Variance of colour temperature to meet the various applications of our customers No negative influence on lifetime from switching cycles Disposal LEDs contain no mercury or other hazardous substances, thereby reducing disposal costs and limiting future liability. 6 Cooper Crouse-Hinds GmbH

Environmentally friendly LEDs do not contain mercury or other hazardous substances, thereby reducing disposal costs and being environmental friendly Meets rising environmental standards Helps to save energy costs and to reduce CO2 footprint Low weight Comparison Conventional Lamps vers. LED-Light Sources Energy Consumption and Savings Energy and cost savings 4W 137 5 Metal Halide 7% 25W 98 295 High Pressure Sodium 67% 98 295 Metal Halide 67% 2W 25 2 Incandescent = LED 88% 1W 98 188 High Pressure Sodium 48% W 98 21 Metal Halide 53% 1W 7W 63 47 93 13 High Pressure Sodium High Pressure Sodium 52% 49% 63 47 84 12 Metal Halide Metal Halide 48% 44% 1 2 3 4 5 Average Energy Reduction with LED LED luminaires on average consume 5% less energy than HID luminaires and 85% less energy than incandescent luminaires. LED luminaires provide higher lumens per watt compared to many traditional lighting technologies (incandescent, compact fluorescent, HID). LED reduces the high maintenance costs associated with traditional lamps and frequent lamp changes Cut overall cost of ownership Energy Consumption (Watts) Cooper Crouse-Hinds LED luminaires provide the same or better light output at a fraction of the energy. 6 Operating life Lumen Output (lumens) 5 4 3 2 1 HPS = 24, hours MH =, hours LED = 6, hours Expected operating life of a Cooper Crouse-Hinds LED luminaire is 6, hours. This is a significant upgrade over traditional light sources, such as incandescent and HID. Heat sinks are specifically engineered to remove heat from the LEDs and driver to ensure longer life, better lumen output and accurate colour temperature. Shock and vibration resistant light source 2, 4, 6, 8, 1, Lamp Life (hours) LED maintains 7% of initial lumen output at end of rated life HID has ~5% failure rate at end of rated life Minimal early failures Cooper Crouse-Hinds GmbH 7