Slimline multi-point for safety and security

Similar documents
Technical Information

ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand

EXIT HARDWARE. Uniclass L CI/SfB (31.59) Xt7 VERSION: AUGUST-11. An ASSA ABLOY Group brand

ABLOY EL460, EL461, EL560, EL561 Europrofile handle controlled locks

ABLOY EL420, EL520 Europrofile motor locks

Security Screen Door Hardware

PHA 2000 PHB 3000 EXIT PAD

Mechanical Digital DX Locks

ABLOY EXIT MECHANICAL LOCK CASES Technical descriptions

Standard Door Specification

KEY CYLINDER PLATFORMS

Approved Document Q: Security

WE ARE UNION. replace with new shot. Mortice Lock Range. ASSA ABLOY, the global leader in door opening solutions

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

RADAR

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Mortice Lock. ASSA ABLOY, the global leader in door opening solutions

ATM SECURITY ATM CASSETTE GUARD KEY FEATURES. High security Rapid installation Simple operation Time locks & delays Proven track record

Narrow stile lock 1314


Code of Practice for fire resisting metal doorsets

Key in Knob & Key in Lever

PROOF ONLY. Police and Fire Service Home Security & Fire Safety Checklist. Student Accommodation Security Checklist

MagTek A. Aluminium Manual Attack Resistant Doors

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

What locks do I have Timber Doors

Simplex 1000 Series. All Simplex Controls are less I.C. core Series packed with both ASA and T strike.

Digital Keypad Use s Manual

Mechanical Entry Locksets

Modular mortice locks

Relevant British, European and International standards

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

Euro Profile Mortice Locks

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Rose Door Handles. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Combi B Alarm box. Mounting instructions

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

Sliding Door Hardware

SECTION 6. Glass Storefront Doors:

Lockwood Home Security Solutions

ASSA HIGH SECURITY LOCKS ASSA Twin ASSA Twin 6000, Twin Exclusive & V10. ASSA cylinders can be supplied in the following keying forms:

TS93 EMR T/PT/TDE. Surface applied door closer

a practical guide to home security.

FIRE/LIFE SAFETY CLOSERS/HOLDERS SERIES

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

NEWSTAR BROCHURE. December 2007

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Protect your home with

Electromagnetic Locking

EMF/EMR. Holder/Release Devices with Integral Door Closers

Tyco PremiAir Pneumatic Actuators

Window Locks. Window Locks

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

7200 series Electromechanical Closer/Holder

INSTALLATION INSTRUCTIONS FOR MODEL 1560 AND 1570 ELECTRIC TRIM CONTROL FOR USE WITH CORBIN 955 AND YALE 626F HEAVY DUTY TRIM

Emergency voice communications Product Name

An overview of mechanical lock and security related standards and why they re important to the Insurance Industry

Multi Function, User Configurable Remote Vehicle Security System with 4 Button Replaceable Membrane Remote Transmitter

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Patented technology ASSA P600. Reliable master key system. ASSA ABLOY, the global leader in door opening solutions

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

9300BC SERIES Light Commercial Door Closer

Slides and Drawers. The right collection

Planet Frameless Glazing. Planet 20 frameless glass swing door

INSTRUCTIONS: LocknCharge Laptop Carts

Exit Devices TABLE OF CONTENTS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

1000 Series Knob Pushbutton Locks

FIREDEX Conventional Fire Panels

NoteLocker 8 NoteLocker 8 as a Floor-standing Solution

UniSas BA. Physical single-person detection. Models: UniSas BA9, UniSas BA12. Energy savings. Eco-design. Recyclable product. Manual Attack Resistance

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

MB Architectural. Lloyd Worrall. Yannedis. London. GB nationwide. Belfast

Automatic Door Selection Guide

RIM MOUNTED AND DUAL ACCESS LOCKS

THE IDEAL SOLUTION SHELVING. Sales Telephone: Sales Fax:

NOT PROTECTIVELY MARKED

Cabinet Locks. Benefits:

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Lock Function Chart Page 1 of 7

ISSUE 2. Installation Guide

Security Shutters, Retractable Security Gates, SeceuroBar & Aluminium Folding Shutter

ABLOY DC 240 DOOR CLOSER Heavy duty door closer

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

Guide to Safety Edge Systems

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

CITADEL. & AX-S Steel Covers. it s about time.

Secure Keypads for access control

DX Mechanical Digital Door Locks Service Manual. ASSA ABLOY, the global leader in door opening solutions

CLEAR-DIVISIONS CENTERFOLD

CERTIFICATE OF APPROVAL No CF 388 ALLEGION (UK) LIMITED

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

ABLOY VEGA CABINET LOCKS

Safety detection solutions

GLOSSARY OF LOCK TERMINOLOGY

Transcription:

Slimline 01.17 High performance, multi-functional systems Surelock Slimline systems enable you to choose a multi-point system tailored to your requirement. The systems: Provide the level of security that you require - from burglary to terrorist attack. Ensures the Duty of Care conformance that you need for security, fire, blast, ballistic, panic or emergency exit. Can enforce an entry/exit procedure and observe your final door status requirement. Slimline Systems are Non-handed. You do not have to specify whether the system is for a right- or left-hand door, unless the enhancement(s) you choose require it. Suitable for both inward- and outward-opening doors. Tested to over one million cycles. Suitable for door heights of up to 2200 mm (extension kits available). Easy to specify (refer to the ordering information at the end of the section). Performance Security Successfully tested on a wide range of LPS 1175 Security Rating 2, 3, 4 and 5 doorsets. Fire Successfully tested on BS 476 part 22:1987 and EN 1634 part 1 doorsets (Certifire accredited) and UL10C doorsets (UL certified). Blast Successfully blast tested on doors in accordance with the methodology set out within ISO 16933 EXV15 & EXV25, utilising the hazard rating as defined for Walls and Doors. Ballistics Successfully tested on doorsets to BS EN 1522:1999 FB1-FB7 inclusive and FSG. Panic Exit Independently type tested to BS EN 1125: 2008 and UL305, CE marked and UL certified. Emergency Exit Independently type tested to BS EN 179: 2008, CE marked. In accordance with our policy of continued development and improvement we reserve the right to make changes in design and specifications without notice. Slimline Slimline multi-point for safety and security page 7

Slimline Safe Exits 01.17 page 8 Slimline: Panic and Emergency exits High performance, safe exit devices Slimline bolting devices are: Strong Simple to specify Non-handed* and bi-directional Tested to over one million cycles Attractively finished Slimline bolting only devices have: Automatic bolting upon door closure Proven rack and pinion mechanism Hardened steel bolts Choice of exit methods Available in stainless steel 316 for hostile environments * Some enhancements require handing to be specified, refer to Enhancement Guide.

91.5 289 15 Slimline Safe Exits 01.17 page 9 Modular system The Slimline range has been designed with a common fixing footprint, enabling alternative modules to be retrofitted to meet changes of customer requirements. Performance Security successfully tested on a wide range of LPS 1175 Security Rating 2, 3, 4 and 5 doorsets Blast successfully blast tested on doorsets to meet the protection of the bomb blast standard for Protected Spaces ; ratings C15 and 'C25 Ballistics successfully tested on doorsets to BS EN 1522:1999 Fire Panic Exit Emergency Exit successfully tested on BS 476 part 22:1987 and EN 1634 doorsets independently type tested to BS EN 1125: 2008, CE marked independently type tested to BS EN 179: 2008, CE marked Operation Slimline safe exits provide auto-bolting upon door closure, with a choice of lever handle or push pad emergency exit, or panic bar when required to comply with buildings used by general public (refer to the Self-coding system guide to select the correct operation). 93.5 46.75 66 Fitting Slimline devises are supplied as standard for surface fitting, ensuring the fabric strength of the door is maintained. Concealed fixing packs are available for mortice fitting to steel, timber and composite doors. 145 76.5 Slimline Features 15mm bolts each with 25mm throw Positive engagement Easily adjusted Slimline SL305 emergency exit centre module dimensions (mm), shown with push pad option H 3 Steel template provides accurate installation and acts as a drilling template for fixings, handle and cylinder positions Suitable for door heights up to 2200 mm, extensions available for higher doors Slimline Benefits High performance Modular design Reliable, offering long trouble free life Choice of entry and exit methods Upgrade solution for existing doors Steel template

Slimline Safe Exits 01.17 page 10 Self-coding system Slimline (SL) modular devices have a simple ordering code that covers the number of securing bolts, the chosen methods of entry and exit, followed by additional enhancements to further customise the device. Slimline devices are suitable for fitting to almost any door; left or right-hand hung, inward- or outward-opening. The device is easy to specify: Step 1. Choose the number of bolts securing (2 or 3) Step 2. Apply entry code 0 (safe exit door)* Step 3. Choose the required exit code 4 (panic) or 5 (emergency) Step 4. Select any enhancements to customise and suit specific requirements That s it! The device is specified. * Panic and emergency exit devices have a 0 entry code. These can be supplied with an external lockable handle, see enhancement code L'. Four steps to Slimline Step 1 Step 2 Step 3 Step 4 Number of bolts Entry Exit Enhancements 2 2-point securing 0 No entry provision 4 Panic exit Enhancement example 3 3-point securing 5 Emergency exit handle L 1 External key entry (recessed LEO) 6 Push pad M Electric monitoring of bolt status W Steel core fixing Note: If key entry is required on bolting-only devices refer to Enhancements code L Example system code: SL 3 0 4-05 - L 1 M W In the above example, SL304 specifies a Slimline 3-point bolting device with panic bar exit method. The code -05- indicates a left hand device.the enhancement codes specify external key entry LEO (L 1 ), electric monitoring of bolt status (M) and steel core fixing (W). Slimline enhancements Devices are normally supplied for surface mounting, with auto-bolting to resecure upon door closure. The Slimline range is supported with a full range of enhancements enabling a device to be tailored to meet the most demanding requirements. Refer to the Slimline Enhancement Guide for full information on available enhancements, together with any handing variants. A selection of frame and floor keeps is available to suit most applications, refer to Slimline Keeps and Strikes for full details.

Slimline Safe Exits 01.17 page 11 Bi-directional restraint UK patent application number 0504198.3 Unique restraint suitable for both inward- and outward-opening doors Non-handed, suitable for both right- and left-hand hung doors Easy adjustment for positive engagement Slimline Handing Slimline is generally not handed but certain enhancements are. The Slimline enhancements list and the handing chart (on the right) provides handing information where required. Outward opening Inward opening Popular Enhancements The following is a summary of the more popular enhancements chosen for Slimline safe exit devices; refer to the full enhancement chart for the wider choice and full details. CODE E n H H 3 L n M O n S T n U n W n DESCRIPTION Height increment above 2200mm; (n) = number of 1000mm increments Free access, non-lockable external handle addition, when security is not an issue (i.e. a fire door) Push pad; in place of inside handle External key and lever handle entry (LEO - Lock with Emergency Override), for appropriate levels of attack resistance Electric monitoring of bolt status Choice of alternative cylinder make (Union 5 pin fitted as standard), including registered and customers own supply Stainless Steel 316 - finish polished Slave unit, provides 90 rotation of a vertical bolt Slave unit, provides 90 rotation and continuation of a vertical bolt Choice of fixings to suit a range of door constructions and level of attack resistance Slimline Operational Specific brochures and Wallcharts are available upon request. Quality statement Our continued commitment to product excellence and accreditation to ISO 9001: 2008 throughout the group ensures unequalled customer satisfaction and is our Seal of Excellence. Intellectual Property Rights All Surelock products are the subject of intellectual property rights. These rights include patent and design rights, in particular UK patents 2289084, 2307270, 2321277, 2323272, 2330375, 2346927, 2351542, 2355282, 2359111, 2361959, 2364740, 2413822, 2423787, 2425325, 2462229 & 2462387, plus UK patent applications 2445948 & 2458893 together with overseas patents and applications. In accordance with our policy of continual development and improvement we reserve the right to make changes in design and specifications without notice.

Slimline Safe Exits 01.17 page 12 Slimline 3-Point Bolting Devices - Enhancements available Entry/Exit Codes CODE 04 05 Description * A 0 Manual bolting * A 3 Auto-bolting sliding door B(n) Packing; (n) = number of 1mm increments E(n) Height increment above 2,200mm; (n) = number of 1,000mm increments H External stainless steel lever handle addition (non lockable) * H 0 Handle(s) not included H 3 Push pad; in place of inside handle H 8 External pad-lockable handle with emergency override (padlock not supplied) H 11 1m long panic bar H 12 Red flat lever inside handle H 14 St/St lever handle inside in lieu of green handle K Key retained in unlocked position K 8 Automatic ratchet locking upon bolt retraction - internal key re-set facility K 14 Manual lock-back facility, bolting only (internal Euro-profile cylinder) L LEO - external key-entry lock with internal emergency override - surface mounted L 1 Recessed LEO (flush fitting) - tested to LPS 1175 rating 3 protection L 2 Recessed LEO (flush fitting) with cylinder guard - tested to LPS 1175 rating 4 protection L 3 LEO with Euro-profile cylinder - external key-entry lock with internal emergency override - surface mounted L 4 Recessed LEO (flush fitting) with Euro-profile cylinder - tested to LPS 1175 rating 3 protection L 5 Recessed LEO (flush fitting) with Euro-profile cylinder and cylinder guard - tested to LPS 1175 rating 4 protection M Electric monitoring of bolt status M 7 Motorised bolt release N Electric monitoring of lock status O 0 Cylinder - supplied free-issue (approved types and factory fitted only) O 1 Cylinder - Kaba-20 (registered) O 2 Cylinder - Assa Twin Combi 5800 (registered) O 3 Cylinder - Yale O 4 Cylinder - Bramah (registered) O 5 Cylinder - Medeco m 3 -ARX (registered) O 9 Cylinder - Abloy Disklock Pro cylinder (registered, gold level) O 10 Cylinder - Kaba quattro plus (registered) O 22 Cylinder - Assa Ruko Flexcore (choice for registration) O 91 Cylinder - Abloy Protec (registered, diamond level) S Stainless steel 316 - finish polished T Slave unit, 90 below handle T 1 Slave unit, 90 above handle U Slave unit, 90 and continue, below handle U 1 Slave unit, 90 and continue, above handle V VIP (Visual Indicator Panel) V 1 VIP (Visual Indicator Panel) with electric monitoring of indicator and isolation keyswitch V 2 VIP (Visual Indicator Panel) with electric monitoring of indicator W Machine screws with steel dowels W 2 Surface fixing by coach screws W 3 Surface fixing by machine screws W 8 Mortice fixing pack with guides - timber doors W 9 Mortice fixing pack with guides - steel doors * Y 0 Single leaf - non BS EN type device Z Double doorset active leaf - BS EN type device * Z 0 Double doorset active leaf and passive leaves - BS EN type device Available enhancements Dependant on other enhancement(s) * Options non-conformant with BS EN 179 and BS EN 1125 certification Indicates handed item

Slimline Safe Exits 01.17 page 13 Slimline 4-Point Bolting Device - Enhancements available Entry/Exit Codes CODE SL405 Description H 3 Push pad; in place of inside handle K Key retained in unlocked position L LEO - external key-entry lock with internal emergency override - surface mounted L 1 Recessed LEO (flush fitting) - tested to LPS 1175 rating 3 protection L 2 Recessed LEO (flush fitting) with cylinder guard - tested to LPS 1175 rating 4 protection L 3 LEO with Euro-profile cylinder - external key-entry lock with internal emergency override - surface mounted L 4 Recessed LEO (flush fitting) with Euro-profile cylinder - tested to LPS 1175 rating 3 protection L 5 Recessed LEO (flush fitting) with Euro-profile cylinder and cylinder guard - tested to LPS 1175 rating 4 protection M Electric monitoring of bolt status N Electric monitoring of lock status O 0 Cylinder - supplied free-issue (approved types and factory fitted only) O 1 Cylinder - Kaba-20 (registered) O 2 Cylinder - Assa Twin Combi 5800 (registered) O 3 Cylinder - Yale O 4 Cylinder - Bramah (registered) O 5 Cylinder - Medeco m 3 -ARX (registered) O 9 Cylinder - Abloy Disklock Pro cylinder (registered, gold level) O 10 Cylinder - Kaba quattro plus (registered) O 22 Cylinder - Assa Ruko Flexcore (choice for registration) O 91 Cylinder - Abloy Protec (registered, diamond level) W Machine screws with steel dowels W 2 Surface fixing by coach screws W 3 Surface fixing by machine screws Available enhancements Dependant on other enhancement(s) Indicates handed item

Slimline Key Release 01.17 page 14 Slimline: Key Release High performance, key entry devices Slimline locking devices are: Strong Simple to specify Non-handed 1 and bi-directional Tested to over one million cycles Attractively finished Slimline key-driven deadlocks have: Automatic re-securing upon door closure Proven rack and pinion mechanism Hardened steel bolts Choice of exit methods Choice of cylinders from leading manufacturers Available in stainless steel 316 for hostile environments * * * When fitted with 'option K' FD240 1 Some enhancements require handing to be specified, refer to Enhancement Guide.

289 91.5 15 Slimline Key Release 01.17 page 15 Modular system Slimline has been designed with a common fixing footprint and key cylinder position, enabling alternative modules to be retrofitted to meet changes of customer requirements. Choice of cylinders* Key cylinders can be selected from most leading manufacturers, or customers own supply, enabling existing suiting requirements to be maintained. * 'Union' cylinders fitted as standard. Key cylinders from most leading manufacturers Performance Slimline provides the renowned Surelock strength and stability required for high performance doors, including: Security Blast successfully tested on a wide range of LPS 1175 Security Rating 2, 3, 4 and 5 doorsets successfully blast tested on doorsets to meet the protection of the bomb blast standard for Protected Spaces ; ratings C15 and 'C25 Ballistics successfully tested on doorsets to BS EN 1522:1999 Fire successfully tested on BS 476 part 22:1987 and EN 1634 doorsets and UL10C doorsets Panic Exit Emergency Exit independently type tested to BS EN 1125: 2008 and UL305, CE marked and UL certified independently type tested to BS EN 179: 2008, CE marked Operation Key release devices, provide automatic re-securement upon door closure with a wide choice of exit solutions including key or turnknob lock release, panic or emergency exit (refer to the Self-coding system guide to select the correct operation). Fitting 93.5 46.75 66 Supplied as standard for surface fitting, ensuring the fabric strength of the door is maintained. Concealed fixing packs are available for mortice fitting to steel, timber and composite doors. Slimline Features 76.5 15mm bolts each with 25mm throw Positive engagement Easily adjusted Steel template provides accurate installation and acts as a drilling template for fixings, handle and cylinder positions Suitable for door heights up to 2200 mm, extensions available for higher doors Slimline Benefits Slimline SL313 Key release centre module dimensions (mm) High performance Modular design Reliable, offering long trouble free life Choice of entry and exit methods Upgrade solution for existing doors Steel template

Slimline Key Release 01.17 page 16 Self-coding system Slimline (SL) modular devices have a simple ordering code that covers the number of securing bolts, the chosen methods of entry and exit, followed by additional enhancements to further customise the device. Slimline devices are suitable for fitting to almost any door; left or right-hand hung, inward- or outward-opening. The device is easy to specify: Step 1. Choose the number of bolts securing (2 or 3) Step 2. Apply entry code 1 (key release) Step 3. Choose required exit code 0, 1, 3, 4 or 5 Step 4. Select any enhancements to customise to suit any specific requirements That s it! The device is specified. Four steps to Slimline Step 1 Step 2 Step 3 Step 4 Number of bolts Entry Exit Enhancements 2 2-point securing 3 3-point securing 1 Key and handle entry 0 No exit provision 1 Key and handle exit 2 Electric release and handle exit 3 Turnknob release and handle exit 4 Panic exit 5 Emergency exit handle Enhancement example N Electric monitoring of lock status O 5 P W Medeco m 3 -ARX (registered cylinder) Cylinder guard Steel core fixing 6 Push pad Indicates handed item Example system code: SL 3 1 3-00 - N O 5 P W In the above example, SL313 specifies a Slimline 3-point device with external key entry, turnknob exit release with lever handle both sides. The enhancement codes specify electric monitoring of lock status (N), Medeco m 3 -ARX cylinder (O 5 ), cylinder guard (P) and steel core fixing (W). Note: The code 00 specifies no particular handing. A handing code is required for certain enhancements (refer to Slimline Enhancements ). Surelock Slimline enhancements Slimline is supported with a full range of enhancements to tailor a device to meet the most demanding requirements. Devices are normally supplied for surface mounting, with auto-bolting and auto-deadlocking. Union 5-pin (non-registered) cylinders are supplied as standard on key-driven locks. Refer to the Slimline Enhancement Guide for further information, together with any handing variants. A wide range of frame and floor keeps are available, refer to Keeps and Strikes for full details.

Slimline Key Release 01.17 page 17 Bi-directional restraint UK patent application number 0504198.3 Unique restraint suitable for both inward- and outward-opening doors Non-handed, suitable for both right- and left-hand hung doors Easy adjustment for positive engagement Popular Enhancements Outward opening Inward opening The following is a summary of the more popular enhancements chosen for Slimline safe exit devices; refer to the full enhancement chart for the wider choice and full details. CODE A 0 E n H 3 K 0 K 7 M N O n P n S T n U n W n DESCRIPTION Manual bolting Height increment above 2200mm; (n) = number of 1000mm increments Push pad; in place of inside handle Manual locking Lock back facility, bolts secured in thrown and retracted position Electric monitoring of bolt status Electric monitoring of lock status Choice of alternative cylinder make (Union 5 pin fitted as standard), including registered and customers own supply Cylinder guard selection for appropriate levels of attack resistance Stainless Steel 316 - finish polished Slave unit, provides 90 rotation of a vertical bolt Slave unit, provides 90 rotation and continuation of a vertical bolt Choice of fixings to suit a range of door constructions and level of attack resistance Slimline Operational Specific brochures and Wallcharts are available upon request. Quality statement Our continued commitment to product excellence and accreditation to ISO 9001: 2008 throughout the group ensures unequalled customer satisfaction and is our Seal of Excellence. Intellectual Property Rights All Surelock products are the subject of intellectual property rights. These rights include patent and design rights, in particular UK patents 2289084, 2307270, 2321277, 2323272, 2330375, 2346927, 2351542, 2355282, 2359111, 2361959, 2364740, 2413822, 2423787, 2425325, 2462229 & 2462387, plus UK patent applications 2445948 & 2458893 together with overseas patents and applications. In accordance with our policy of continual development and improvement we reserve the right to make changes in design and specifications without notice.

Slimline Key Release 01.17 page 18 Slimline Key Release Deadlocks - Enhancements available Entry/Exit Codes CODE 01 10 11 13 14* 15* Description = A 0 Manual bolting = A 3 Auto-bolting sliding doors B(n) Packing; (n) = number of 1mm increments E(n) Height increment above 2200mm; (n) = number of 1000mm increments = H 0 Handle(s) not included H 3 Push pad; in place of inside handle H 9 Handles not included; with 8mm follower H 11 1m long panic bar H 14 St/St lever handle inside in lieu of green handle K Key retained in unlocked position K 0 Manual locking K 4 K 6 Break-dome over turnknob Lockable in the retracted position only (function according to system type) K 7 Lockable in thrown and retracted position (function according to system type) K 12 Euro-profile cylinder in place of rim-latch style cylinder K 15 Shrouded turnknob M Electric monitoring of bolt status M 7 Motorised bolt release (only available with option A 0 ) N Electric monitoring of lock status O 0 Cylinder - supplied free-issue (approved types and factory fitted only) O 1 Cylinder - Kaba-20 (registered) O 2 Cylinder - Assa Twin Combi 5800 (registered) O 3 Cylinder - Yale O 4 Cylinder - Bramah (registered) O 5 Cylinder - Medeco m 3 -ARX (registered) O 9 Cylinder - Abloy Disklock Pro cylinder (registered, gold level) O 10 Cylinder - Kaba quattro plus (registered) O 22 Cylinder - Assa Ruko Flexcore (choice for registration) O 91 Cylinder - Abloy Protec (registered, diamond level) P Cylinder guard for door thickness 44-60mm - tested to LPS1175 Rating 3 protection P 4 P 5 Cylinder guard to take Euro-profile cylinder - tested to LPS1175 Rating 3 protection Cylinder guard for door thickness 44-60mm - tested to LPS1175 Rating 4 protection P 6 Cylinder guard for door thickness 44-60mm - tested to LPS1175 Rating 5 protection S Stainless steel 316 - finish polished T Slave unit, 90 below handle T 1 Slave unit, 90 above handle U Slave unit, 90 and continue, below handle U 1 Slave unit, 90 and continue, above handle W Machine screws with steel dowels W 2 Surface fixing by coach screws W 3 Surface fixing by machine screws W 8 Mortice fixing pack with guides - timber doors W 9 Mortice fixing pack with guides - steel doors = Y 0 Single leaf - non BS EN type device = Z Z 0 Double doorset active leaf - BS EN type device Double doorset active leaf and passive leaves - non BS EN type device Available enhancements Dependant on other enhancement(s) =Options non-conformant with BS EN 179 and BS EN 1125 certification * Indicates handed item

Slimline Electric Release 01.17 page 19 Slimline: Electric Release High performance, access control entry devices Slimline locking devices are: Strong Simple to specify Non-handed 1 and bi-directional Tested to over one million cycles Attractively finished Slimline electric release deadlocks have: Automatic re-securing upon door closure Proven rack and pinion mechanism Hardened steel bolts Choice of exit methods Available in stainless steel 316 for hostile environments * * * When fitted with 'option K' FD240 1 Some enhancements require handing to be specified, refer to Enhancement Guide.

289 91.5 15 Slimline Electric Release 01.17 page 20 Modular system Slimline has been designed with a common fixing footprint and key cylinder position, enabling alternative modules to be retrofitted to meet changes of customer requirements. External key override in case of power failure An external key override can be provided to cover for the possibility of power failure, with cylinders from most leading manufacturers, or customers own supply, enabling existing suiting requirements to be maintained. Performance Slimline provides the renowned Surelock strength and stability required for high performance doors, including: Security Blast successfully tested on a wide range of LPS 1175 Security Rating 2, 3, 4 and 5 doorsets successfully blast tested on doorsets to meet the protection of the bomb blast standard for Protected Spaces ; ratings C15 and 'C25 Ballistics successfully tested on doorsets to BS EN 1522:1999 Fire Panic Exit Emergency Exit successfully tested on BS 476 part 22:1987 and EN 1634 doorsets and UL10C doorsets independently type tested to BS EN 1125: 2008 and UL305, CE marked and UL certified independently type tested to BS EN 179: 2008, CE marked Operation Electric release devices, provide automatic re-securement upon door closure with a wide choice of exit solutions including access control or turnknob lock release, panic or emergency exit (refer to the Self-coding system guide to select the correct operation). Fitting Supplied as standard for surface fitting, ensuring the fabric strength of the door is maintained. Concealed fixing packs are available for mortice fitting to steel, timber and composite doors. 93.5 46.75 66 Slimline Features 15mm bolts each with 25mm throw Positive engagement Easily adjusted Steel template provides accurate installation and acts as a drilling template for fixings, handle and cylinder positions Suitable for door heights up to 2200 mm, extensions available for higher doors Slimline Benefits High performance Modular design Reliable, offering long trouble free life Choice of entry and exit methods Upgrade solution for existing doors 76.5 Slimline SL322 electric release centre module dimensions (mm) Steel template

Slimline Electric Release 01.17 page 21 Self-coding system Slimline (SL) modular devices have a simple ordering code that covers the number of securing bolts, the chosen methods of entry and exit, followed by additional enhancements to further customise the device. Slimline devices are suitable for fitting to almost any door; left or right-hand hung, inward- or outward-opening. The device is easy to specify: Step 1. Choose the number of bolts securing (2 or 3) Step 2. Apply entry code 2 (electric release) Step 3. Choose required exit code 0, 2, 3, 4 or 5 Step 4. Select any enhancements to customise to suit any specific requirements That s it! The device is specified. Four steps to Slimline Step 1 Step 2 Step 3 Step 4 Number of bolts Entry Exit Enhancements 2 2-point securing 3 3-point securing 2 Electric release and handle entry 0 No exit provision 1 Key and handle exit 2 Electric release and handle exit 3 Turnknob release and handle exit Enhancement example K 2 External key release in case of power failure O 5 Medeco m 3 -ARX registered cylinder 4 Panic exit P 5 Cylinder guard 5 Emergency exit handle W Steel core fixing 6 Push pad Indicates handed item Example system code: SL 3 2 5-04 - K 2 O 5 P 5 W In the above example, SL325 specifies a Slimline 3-point device external electric lock release with lever handle and a lever handle emergency exit from the inside. The enhancement codes specify external key release in case of power failure (K 2 ), Medeco m 3 -ARX cylinder (O 5 ), cylinder guard (P 5 ) and steel core fixing (W). Note: The handing code 04 specifies right hand as the ergonomically designed emergency handle, exit code 5 is a handed item. Power consumption Slimline standard solenoids are 12V energise to unlock (fail secure) with alternative 24V and 50V, plus energise to lock (fail safe), all available. Refer to the Slimline Enhancement Guide for full information. Surelock Slimline enhancements Voltage (dc) Power consumption Current draw V W A 12 6.3 0.53 24 6.3 0.26 50 6.3 0.13 Slimline is supported with a full range of enhancements to tailor a device to meet the most demanding requirements. Devices are normally supplied for surface mounting, with auto-bolting and auto-deadlocking. Refer to the Slimline Enhancement Guide for further information, together with any handing variants. A wide range of frame and floor keeps are available, refer to Keeps and Strikes for full details.

Slimline Electric Release 01.17 page 22 Bi-directional restraint UK patent application number 0504198.3 Unique restraint suitable for both inward- and outward-opening doors Non-handed, suitable for both right- and left-hand hung doors Easy adjustment for positive engagement Outward opening Inward opening Popular Enhancements The following is a summary of the more popular enhancements chosen for Slimline electric release devices; refer to the full enhancement chart for the wider choice and full details. CODE E n A 0 H 3 K 0 K 7 M N O n P n R n S T n U n W n DESCRIPTION Height increment above 2200mm; (n) = number of 1000mm increments Manual bolting Push pad; in place of inside handle Manual locking Lock back facility, bolts secured in thrown and retracted position Electric monitoring of bolt status Electric monitoring of locking status Choice of alternative cylinder make (Union 5 pin fitted as standard), including registered and customers own supply Cylinder guard selection for appropriate levels of attack resistance Alternative 24V and 50V solenoids (12V as standard), plus fail safe/secure options Stainless Steel 316 - finish polished Slave unit, provides 90 rotation of a vertical bolt Slave unit, provides 90 rotation and continuation of a vertical bolt Choice of fixings to suit a range of door constructions and level of attack resistance Slimline Operational Specific brochures and Wallcharts are available upon request. Quality statement Our continued commitment to product excellence and accreditation to ISO 9001: 2008 throughout the group ensures unequalled customer satisfaction and is our Seal of Excellence. Intellectual Property Rights All Surelock products are the subject of intellectual property rights. These rights include patent and design rights, in particular UK patents 2289084, 2307270, 2321277, 2323272, 2330375, 2346927, 2351542, 2355282, 2359111, 2361959, 2364740, 2413822, 2423787, 2425325, 2462229 & 2462387, plus UK patent applications 2445948 & 2458893 together with overseas patents and applications. In accordance with our policy of continual development and improvement we reserve the right to make changes in design and specifications without notice.

Slimline Electric Release 01.17 page 23 Slimline Electric Release Deadlocks - Enhancements available Entry/Exit Codes CODE 20 21 22 23 24* 25* Description = = = = A 3 Auto-bolting sliding doors B(n) Packing; (n) = number of 1mm increments E(n) Height increment above 2200mm; (n) = number of 1000mm increments H 0 Handle(s) not included H 3 Push pad; in place of inside handle H 9 Handles not included; with 8mm follower H 11 1m long panic bar H 12 Red flat lever inside handle H 14 St/St lever handle inside in lieu of green handle K 2 External key release in case of power failure K 4 K 12 Break-dome over turnknob Euro-profile cylinder in place of rim-latch style cylinder K 15 Shrouded turnknob M Electric monitoring of bolt status M 7 N O 0 Motorised bolt release Electric monitoring of lock status Cylinder - supplied free-issue (approved types and factory fitted only) O 1 Cylinder - Kaba-20 (registered) O 2 Cylinder - Assa Twin Combi 5800 (registered) O 3 Cylinder - Yale O 4 Cylinder - Bramah (registered) O 5 Cylinder - Medeco m 3 -ARX (registered) O 9 Cylinder - Abloy Disklock Pro cylinder (registered, gold level) O 10 Cylinder - Kaba quattro plus (registered) O 22 Cylinder - Assa Ruko Flexcore (choice for registration) O 91 Cylinder - Abloy Protec (registered, diamond level) P Cylinder guard for door thickness 44-60mm - tested to LPS1175 Rating 3 protection P 4 Cylinder guard to take Euro-profile cylinder - tested to LPS1175 Rating 3 protection P 5 Cylinder guard for door thickness 44-60mm - tested to LPS1175 Rating 4 protection R 1 Access control (energise to unlock) 24V solenoid R 2 Access control (energise to lock)12v solenoid R 3 Access control (energise to lock) 24V solenoid R 4 Access control (energise to unlock) 50V solenoid R 7 Access control (energise to lock) 50V solenoid S Stainless steel 316 - finish polished T Slave unit, 90 below handle T 1 Slave unit, 90 above handle U Slave unit, 90 and continue, below handle U 1 Slave unit, 90 and continue, above handle W Machine screws with steel dowels W 2 Surface fixing by coach screws W 3 Surface fixing by machine screws W 8 Mortice fixing pack with guides - timber doors W 9 Mortice fixing pack with guides - steel doors Y 0 Single leaf - non BS EN type device Z Double doorset active leaf - BS EN type device Z 0 Double doorset active leaf and passive leaves - non BS EN type device Available enhancements Dependant on other enhancement(s) = Options non-conformant with BS EN 179 and BS EN 1125 certification * Indicates handed item www.surelock.co.uk

Slimline Combination Lock Entry 01.17 page 24 Slimline: Combination Lock Entry High performance, controlled entry Slimline combination lock devices are: Strong Simple to specify Bi-directional Tested to over one million cycles Attractively finished Slimline combination release deadlocks have: Proven rack and pinion mechanism Hardened steel bolts Choice of combination locks from leading manufacturers

289 91.25 15 Slimline Combination Lock Entry 01.17 page 25 Modular System Slimline has been designed with a common fixing footprint and lock position, enabling alternative modules to be retrofitted to meet changes of customer requirements. Performance Slimline provides the renowned Surelock strength and stability required for high performance doors, including: Security Blast successfully tested on a wide range of LPS 1175 Security Rating 2, 3, 4 and 5 doorsets successfully blast tested on doorsets to meet the protection of the bomb blast standard for Protected Spaces ; ratings C15 and 'C25 Ballistics successfully tested on doorsets to BS EN 1522:1999 Fire Panic Exit Emergency Exit Operation successfully tested on BS 476 part 22:1987 and EN 1634 doorsets independently type tested to BS EN 1125: 2008, CE marked independently type tested to BS EN 179: 2008, CE marked Combination lock release devices provide a choice from leading manufacturers of mechanical and electronic combination lock entry, with automatic bolting upon door closure (refer to the Self-coding system guide to select the correct operation). Fitting Supplied as standard for surface fitting, ensuring the fabric strength of the door is maintained for fitting to steel, timber and composite doors. Slimline Features 15mm bolts each with 25mm throw Positive engagement Easily adjusted Steel template provides accurate installation and acts as a drilling template for fixings, handle and cylinder positions Suitable for door heights up to 2200 mm, extensions available for higher doors Slimline Benefits High performance Modular design Reliable, offering long trouble free life Choice of entry locks from leading manufacturers Upgrade solution for existing doors 66 76.5 222.25 Slimline SL335 combination lock release centre module dimensions (mm) L/H shown.

Slimline Combination Lock Entry 01.17 page 26 Self-coding system Slimline (SL) modular devices have a simple ordering code that covers the number of securing bolts, the chosen methods of entry and exit, followed by additional enhancements to further customise the device. Slimline devices are suitable for fitting to almost any door; inward- or outward-opening. The device is easy to specify: Step 1. Choose the number of bolts securing (2 or 3) Step 2. Apply entry code 3 (combination lock release) Step 3. Choose required exit code Step 4. Select any enhancements to customise to suit any specific requirements That s it! The device is specified. Four steps to Slimline Step 1 Step 2 Step 3 Step 4 Number of bolts Entry Exit Enhancements 2 2-point securing 3 3-point securing 3 Combination lock release and handle entry 4 Panic exit 5 Emergency exit handle Enhancement example W Steel core fixing 6 Push pad Indicates handed item Example system code: SL 3 3 5-04 - W In the above example, SL335 specifies a Slimline 3-point device, external combination lock release with lever handle and a lever handle emergency exit from the inside. The enhancement code W specifies steel core fixing. Note: The handing code 04 specifies right hand as the combination lock release are handed devices. Surelock Slimline enhancements Slimline is supported with a full range of enhancements to tailor a device to meet the most demanding requirements: Devices are normally supplied for surface mounting. Refer to the Slimline Enhancement Guide for further information. A wide range of frame and floor keeps are available, refer to Keeps and Strikes for full details. Bi-directional restraint UK patent application number 0504198.3 Unique restraint suitable for both inward and outward opening doors Easy adjustment for positive engagement Outward opening Inward opening

Slimline Combination Lock Entry 01.17 page 27 Slimline handing Combination lock entry devices are handed. Our handing chart (on the right) shows the codes we use to indicate door handing and opening direction. Popular enhancements The following is a summary of the more popular enhancements chosen for Slimline combination lock release devices; refer to the full enhancement chart for the wider choice and full details. CODE E n H 3 K n K 2 K 7 K 9 M T n U n W n DESCRIPTION Height increment above 2200mm; (n) = number of 1000mm increments Push pad; in place of inside handle Choice of alternative mechanical and electronic combination lock (S&G 8550 combination lock as standard) External key override of lock-in facility (safe access) Lock back facility addition, bolts secured in thrown and retracted position Internal lock-in facility; turnknob activated Electric monitoring of bolt status Slave unit, provides 90 rotation of a vertical bolt Slave unit, provides 90 rotation and continuation of a vertical bolt Choice of fixings to suit a range of door constructions and level of attack resistance Slimline Operational Specific brochures and Wallcharts are available upon request. Quality statement Our continued commitment to product excellence and accreditation to ISO 9001: 2008 throughout the group ensures unequalled customer satisfaction and is our Seal of Excellence. Intellectual Property Rights All Surelock products are the subject of intellectual property rights. These rights include patent and design rights, in particular UK patents 2289084, 2307270, 2321277, 2323272, 2330375, 2346927, 2351542, 2355282, 2359111, 2361959, 2364740, 2413822, 2423787, 2425325, 2439327, 2445948, 2462229, 2462387 & 2458893 together with overseas patents and further applications. In accordance with our policy of continual development and improvement we reserve the right to make changes in design and specifications without notice.

Slimline Combination Lock Entry 01.17 page 28 Slimline Combination Deadlocks - Enhancements available Entry/Exit Codes CODE 30* 35* Description B(n) Packing; (n) = number of 1mm increments E(n) Height increment above 2,200mm; (n) = number of 1,000mm increments H 3 Push pad; in place of inside handle K 17 Kaba Mas Auditcon 552 electronic lock K 22 S&G 2740 electro-mechanical lock M Electric monitoring of bolt status S Stainless steel 316 - finish polished T Slave unit, 90 below handle T 1 Slave unit, 90 above handle U Slave unit, 90 and continue, below handle U 1 Slave unit, 90 and continue, above handle W Machine screws with steel dowels W 2 Surface fixing by coach screws = W 3 Y 0 Surface fixing by machine screws Single leaf - non BS EN type device = Z Z 0 Double doorset active leaf - BS EN type device Double doorset active and passive leaves - non BS EN type device Available enhancements = Options non-conformant with BS EN 179 and BS EN 1125 certification * Indicates handed item

Slimline Enhancements 01.17 page 29 Slimline: Enhancements Enhancements have been designed and tested to enable a basic Slimline device to be closely tailored to meet customer s individual requirements, to ensure the performance of a building and those who use the building. Correct selection will ensure that a door will return to a specific status upon closure and if required linked to other doors to create an Air-lock application. Each type of enhancement has been allocated an alpha code with numeric variants for each as applicable. The following section describes each in as much detail as possible and where necessary technical information has been included to assist in making the correct choice. A wall chart is available listing all enhancements available for each device. CODE DESCRIPTION PAGE A Manual/Auto-bolting 2 B Packing 2 E Height increments 2 H Handle variants 3 K Operational variants 4-5 L External key/handle entry lock (LEO) for Safe exit bolting devices 6-8 M Electric monitoring of bolt status 9 N Electric monitoring of lock status 10 O Key cylinder variants from most leading manufacturers, including customer s own supply 11-12 P Cylinder protection, various levels of testing included 13-14 R Solenoid voltage and power to lock/unlock (fail safe/secure status) 15 S Stainless steel 316 - finish polished 15 T Slave unit, 90 turn of the bolt 16 U Slave unit, 90 turn of the bolt and continue 16 V Visual indicator panel 17 W Various fixing screw packs to suit door construction 18-19 Y Non BS EN device reference 20 Z Double door leaf - BS EN device reference 20-21

Slimline Enhancements 01.17 page 30 Option A (n) Option A 0 Manual/Auto-bolting Standard Slimline devices provide automatic bolting upon door closure together with a patented bi-directional restraint mechanism, suitable for both inward-and outward-opening hinged doors. Enhancement A(n) provides alternatives to this. Manual bolting Auto-bolting not provided. Manual operation required both to throw and retract bolts. Note: Non compliant for CE marked panic and emergency exits Option A 3 Auto-bolting for sliding doors Top guide and restraint supplied to suit a sliding door application. Top guide, restraint and keep for sliding doors - Option A 3 Option B (n) Packing Additional packing under the device, (n) represents the thickness of packing (mm). Bolts are already 5mm from the face of the door. Option E (n) Height Extensions For doors above 2200mm tall; (n) represents the number of 1000mm increments, each increment includes an additional guide bracket. Example: E 1 is suitable for doors up to 3200mm high

282 228 Slimline Enhancements 01.17 page 31 Option H (n) Handle Varients Various handle combinations can be selected from those normally supplied for each device. Option H Option H 0 External lever handle Stainless steel external handle added to Exit only devices; provides free access where security is not an issue (i.e. a fire wall partition door). Handle(s) not included, with standard 9.5mm follower Enables architectural designed handles with 9.5mm square shaft to be selected, non-compliant to BS EN 179: 2008 emergency exit accreditation and no CE marking. NB: Check with technical department regarding suitable handle requirements. Option H 3 Push pad in place of inside handle Alternative exit operator retains the BS EN 179: 2008 accreditation and CE marking. 5 83 121 Option H 9 Handle(s) not included, with standard 8mm follower Enables architectural designed handles with 8mm square shaft to be selected, non-compliant to BS EN 179: 2008 emergency exit accreditation and no CE marking. NB: Check with technical department regarding suitable handle requirements. Option H 11 1m bar For wider doors when a 1000mm panic bar is preferred to the standard 800mm length bar. Note: Doors wider than 1300mm are outside the scope of BS EN 1125: 2008.

Slimline Enhancements 01.17 page 32 Option K (n) Operational Varients Various locking combinations can be selected from those normally supplied for each device. Option K Option K 0 Option K 2 Key retained in unlocked position The key is held retained after unlocking until it is re-secured, ensuring the device is always locked following key withdrawal. This provides a forced securing function when the key is attached to the user. Manual locking Removes the auto-deadlocking feature (supplied as standard), for applications when a door is needed to remain unlocked, i.e. to provide free access in a day-time mode. External key release in case of power failure Provides a key entry facility for electric release devices in the event of power failure. Option K 4 Break-dome over turnknob Provides a manual lock release facility with visual awareness of an event, i.e. for use on controlled exits, or in the case of power failure for electric release devices. 52.5 Break-dome over turnknob - Option K 4 Option K 6 Lockable in the retracted position only Enables the bolts to be secured in the retracted position. Option K 7 Option K 8 Lockable in the thrown and retracted position Enables the bolts to be secured in the thrown and retracted position. Automatic ratchet locking upon bolt retraction, with breach awareness A ratchet mechanism secures the bolts when retracted. A key re-set facility is provided.

125 Slimline Enhancements 01.17 page 33 Option K 12 Euro-profile cylinder in place of rim-latch style cylinder To be selected when device is to be fitted in a concealed mortice application.. Note: Euro-profile cylinders are standard with options W8 and W9 (mortice fitting devices), where applicable. Euro-profile cylinder - Option K 12 Option K 14 Manual lock-back facility, bolting only (internal Euro-profile cylinder) Enables the bolts of a bolting only device to be secured in their retracted position by internal key operation only, i.e. day-time non auto-bolting application. Option K 15 Shrouded turnknob A shield over the turnknob to help prevent external manipulation. 20.5 74.5 Shrouded turnknob - Option K 15 161 258 62 Option K 17 Kaba Mas Auditcon 552 electronic lock Combination lock alternative - an electronic combination lock in place of the standard Manifoil combination lock.

Slimline Enhancements 01.17 page 34 Option L (n) LEO - Lock with Emergency Override A choice of external key lockable lever handles provides entry for Safe Exit devices. Almost all key cylinder manufacturers can be accommodated to suit a customer s preference and/or special suiting requirement (Union fitted as standard). Cylinder guards have been tested to meet the demanding security requirements of LPS 1175 Security Ratings 2, 3 & 4. Option L LEO - surface fitting 65 Face fitted to the external face of the door with fixing bolts passing right through the core of the door in a sandwich construction. 26.5 123 180 Fitted with a screw-in type cylinder. Option L 1 LEO - recess fitting 65 The body of the LEO is recessed into the external face of the door with fixing bolts passing right through the core of the door in a sandwich construction. 32 54 22.5 6 Fitted with a screw-in type cylinder. 168 123 190 28 Ø28 M8 FIXING SCREWS Option L 2 LEO - recess fitting LPS 1175 65 SR 4 As L 1 but armoured with a manganese cylinder guard and anti-drilling disk. 32 54 22.5 6 Fitted with a screw-in type cylinder. 28 Ø28 168 123 190 35 9.4 32 M8 FIXING SCREWS LEO - Options L LEO - Option L 1 LEO - Option L 2 Indicates handed item

Slimline Enhancements 01.17 page 35 Option L 3 LEO - surface fitting 65 Face fitted to the external face of the door with fixing bolts passing right through the core of the door in a sandwich construction. 123 180 Fitted with a Euro-profile cylinder permitting on-site cylinder changing. 26.5 35 32 Option L 4 LEO - recess fitting The body of the LEO is recessed into the external face of the door with fixing bolts passing right through the core of the door in a sandwich construction. Fitted with a Euro-profile cylinder permitting on-site cylinder changing. 65 32 54 22.5 6 28 Ø28 168 123 190 M8 FIXING SCREWS Option L 5 LEO - recess fitting 65 As L 4 but armoured with a manganese cylinder guard and anti-drilling disk. Fitted with a Euro-profile cylinder permitting on-site cylinder changing. 32 54 22.5 6 28 Ø28 168 123 190 M8 FIXING SCREWS LEO - LEO - LEO - Option L 3 Option L 4 Option L 5

Slimline Enhancements 01.17 page 36 Option M Electric Monitoring of the Bolt Status A double pole microswitch provides a signal when the bolt is thrown. Option 'M' wiring diagram N/C BLUE 1 N/O GREEN 2 C RED 3 Note: Cable core colours may change if other electrical enhancements are fitted. Option M 7 Motorised bolt release Enables remote activation to drive the multiple bolts to their retracted position, the bolts are initially held in their retracted position by a timer whilst door opening is being initiated, the bolts are then held retracted by the top restraint mechanism whilst the door is open and the motor returning to its parked position. The bolts automatically resecuring upon door closure. Supplied complete with a controller, with outputs for bolt and lock status monitoring and a door actuator. The controller requires mains electrical input. Typical applications: Disabled access Remote building activation Sterile entry areas Technical Information: Voltage 24V DC M 7 Motorised bolt release, left hand shown Indicates handed item

Slimline Enhancements 01.17 page 37 Option N Electric Monitoring of the Lock Status A double pole microswitch provides a signal when the lock is secure. Option 'N' wiring diagram N/C BLUE 1 N/O GREEN 2 C RED 3 Note: Cable core colours may change if other electrical enhancements are fitted.

Slimline Enhancements 01.17 page 38 Option O (n) Cylinder Variants The Slimline range of devices are fitted with Union (5 pin) cylinders as standard but almost any make of cylinder can be specified. This usually enables preferred cylinders and current key suiting to be maintained. Registered cylinders are available to provide a higher level of key control. The following cylinder variants indicate the manufacturer, model, registering information and security level of cylinder to the European BS EN 1303 and UL standards. Option O 0 Customers own supply Where a customer chooses to issue cylinders to Surelock McGill, this must be supported with a key for quality control inspection before despatch. The make of cylinder must be advised when ordering to ensure correct configuration of the device. Do this by following the option code O 0 with the code for the cylinder that you will provide. For example, code O 0 O 5 indicates that you are going to supply a Medeco m 3 -ARX cylinder. Option O 1 Kaba 20 Registered BS EN 1303 UL yes 6-2 Option O 2 Assa Twin-Combi Registered BS EN 1303 UL yes 6-2 437 Option O 3 Yale (5 pin) Registered BS EN 1303 UL no Option O 4 Bramah Registered BS EN 1303 UL yes Option O 5 Medeco m 3 -ARX Registered BS EN 1303 UL yes 6-2 437

Slimline Enhancements 01.17 page 39 Option O 6 Ingersoll Registered BS EN 1303 UL yes Option O 9 Abloy Disklock Pro Registered BS EN 1303 UL yes 6-2 Option O 10 Kaba quattro plus Registered BS EN 1303 UL yes 6-2 Option O 22 Assa Ruko Flexcore Registered BS EN 1303 UL yes 3-0 Option O 91 Abloy Protech Registered BS EN 1303 UL yes 6-2

Slimline Enhancements 01.17 page 40 Option P (n) Cylinder Guards A range of cylinder guards are available to suit various makes and cylinder profiles, including rim-latch, profile and screw-in cylinders. Cylinder guards have been tested to meet the demanding security requirements of LPS 1175 Security Ratings 2, 3, 4 & 5. Option P Rim cylinder guard LPS 1175 Ø56 SR 3 Stainless steel cylinder guard for conventional shape rim style cylinders, complete with manganese anti-drill protection, for door thickness 44-60mm. 5 9 58 48 38 30 72 Option P 4 Euro-profile cylinder guard Stainless steel cylinder guard for Euro-profile cylinder style cylinders, complete with manganese anti-drill projections. Ø50 3 34 Ø53 Cylinder guards - Option P Cylinder guard - Option P 4

Slimline Enhancements 01.17 page 41 Option P 5 Rim cylinder guard LPS 1175 n56 SR 4 Manganese steel cylinder guard for conventional shape rim latch style cylinders, complete with manganese anti-drill protection, for door thickness 44-60mm. 5 58 9 30 72 Option P 6 Rim cylinder guard LPS 1175 SR 5 Manganese steel cylinder guard for conventional shape rim latch style cylinders, complete with cobalt anti-drill protection, for door thickness 52-60mm. 5 Ø56 48 9 42 38 58 36.5 Ø12 72 30 Cylinder guard - Option P 5 Cylinder guard - Option P 6

Slimline Enhancements 01.17 page 42 Option R (n) Solenoid Variants A selection of continuous rated dc. solenoids with various voltages and operational features. The default standard is 12V, energise to lock (fail secure in the case of power failure) with 6.3W power consumption and 0.53A current draw. Voltage Energise to: Power consumption Current draw Option R 1 Option R 2 Option R 3 Option R 4 Option R 7 24V Unlock - fail secure 6.3W 0.26A 12V Lock - fail safe 6.3W 0.53A 24V Lock - fail safe 6.3W 0.26A 50V Unlock - fail secure 6.3W 0.13A 50V Lock - fail safe 6.3W 0.13A Option S Stainless Steel Corrosion resistant stainless steel 316 with a polished finish. Ideal for offshore, saline and other hostile situations as well as medical clean rooms. Example of stainless steel - Option S

Slimline Enhancements 01.17 page 43 Option T 90 change of bolt direction below handle A slave unit that provides a 90 change in direction to secure the lower bolt into the door frame. Typically used where the floor is not suitable for a bottom vertical bolt. Option T 1 90 change of bolt direction above handle A slave unit that provides a 90 change in direction to secure the lower bolt into the door frame. Typically used where the head is not suitable for a top vertical bolt. Option U 90 change of bolt direction and continue below handle A slave unit that provides an additional 90 lower horizontal bolt securing into the door frame. It is typically used to provide additional strength on inward opening doors where the frame rebate does not aid resistance to attack. Option U 1 90 change of bolt direction and continue above handle A slave unit which provides an additional 90 upper horizontal bolt securing into the door frame. It is typically used on overheight doors, or to provide additional strength on inward opening doors where the frame rebate does not aid resistance to attack. 111.6 104 150 23 38.4 23 104 150 Additional directions and drives available with slave units 93.5 93.5 90 o Slave - 90 o Slave & continue - Option T & T 1 Option U & U 1

Slimline Enhancements 01.17 page 44 Option V (n) VIP (Visual Indicator Panels) A selection of visual indicator panels with a choice of electric monitoring and isolation features. Each device re-secures automatically upon door closure. Option V Option V 1 Option V 2 VIP (Visual Indicator Panel) A red indicator flag is driven out when retracting the bolts. This provides a high visibility indication of a door breach. The device re-secures automatically upon door closure. The indicator is reset with a key. VIP (Visual Indicator Panel) with status monitoring & isolation As V but with a microswitch monitoring the bolt retraction and an isolation keyswitch to provide de-activation of the alarm for authorised use. Both key cylinders are keyed alike. VIP (Visual Indicator Panel) with status monitoring As V but with a microswitch monitoring the bolt retraction. 138 102 34 35 66 198 405.5 78 206 VIP examples of - Option V & V 2 99 93.5 24.8

Slimline Enhancements 01.17 page 45 Option W (n) Fixing Packs A selection of fixing packs is available to suit mortice and surface fitting devices to both timber and steel doors. Option W Steel core - surface fixing to timber doors The most secure way of fixing a surface fitted device to a timber door. Steel dowels with threaded nuts inserted into the core of the door, machine screws pass through the device securing into the threaded nuts, ensuring a strong secure fitting. Option W 2 Coach screw - surface fixing to timber doors A fast and simple way of fixing a surface fitted device to a timber door. Option W 3 Machine screw - surface fixing to steel doors A fast and simple way of fixing a surface fitted device to a steel door. Option W 5 Security screw - surface fixing to timber doors Pin-Torx screws supplied to provide a tamper resistant method of fixing a surface fitted device to a timber door. Option W 6 Security screw - surface fixing to steel doors Pin-Torx screws supplied to provide a tamper resistant method of fixing a surface fitted device to a steel door.

Slimline Enhancements 01.17 page 46 Option W 8 Mortice fixing pack for timber doors Comprising of a set of door edge guides for fitting to a prepared timber door to support the bolts as they pass out of the door. The centre module is mounted on the forend plate fitted to the leading edge of the door and guiding the horizontal bolt. Note: Euro-profile cylinders are supplied on concealed mortice devices where applicable. Option W 9 Mortice fixing pack for steel doors Comprising of a set of door edge guides for fitting to a prepared steel door to support the bolts as they pass out of the door. The centre module is mounted on the forend plate fitted to the leading edge of the door and guiding the horizontal bolt. Note: Euro-profile cylinders are supplied on concealed mortice devices where applicable. Concealed mortice fixing packs - Option W 8 & W 9

Slimline Enhancements 01.17 page 47 Option Y 0 Single leaf - non BS EN type device Where the sprung bottom bolt of a bolting-only device is not required. Option Y 0 Option Z Double doorset active leaf - BS EN1125 type device Identifier for a device that is for the active leaf of a BS EN1125 accredited double doorset. Such a device is supplied with three horizontal bolts that secure against the passive leaf. Strike plates are included for the passive leaf. Double doorset BS EN1125 active leaf device - Option Z

Slimline Enhancements 01.17 page 48 Option Z 0 Double doorset active and passive leaves - non BS EN type device Identifier for both the active and passive leaf of a non BS EN accredited double doorset. Comprises interlinked panic bars for both active and passive leaves. Sprung bottom bolt not included. Double doorset interlinks non BS EN device - Option Z 0

Slimline Enhancements 01.17 page 49 Slimline: Frame keeps and base plates for surface-mounted systems A wide selection of keeps and strike plates are available to suit almost every application. These need to be ordered separately. Available in heavy-section steel with a grey-white RAL 9002 leatherette powder coating finish, or from polished stainless steel (add suffix -S to your ordering code). For steel core (dowel) fixing add suffix -W to your ordering code. SA Frame keep and base plate Designed to receive the horizontal bolt on an inward- or outward-opening door hung in a steel frame. 73 25 M6 CLEAR 3 5 20 SA1 Extended frame keep and base plate Designed to receive the horizontal bolt on outward-opening double-leaf timber or steel doors. The extended base plate ensures that the fixing screws enter into the solid section of the door and not the narrow section formed by the rebate. SA1 may also be used in place of the standard SA where a secure fixing near the edge of the frame is not possible. 73 M6 CLEAR 3 16 25 5 20 SA2 Frame keep and base plate with striker 73 Used in conjunction with the Slimline autobolting feature, the frame keep and base plate with striker is designed for use on narrow-section metal frames with an outward-opening door. The striker releases the restraint mechanism within the Slimline system, allowing the bolts to fire automatically into their respective keeps, thus giving a slam-shut facility. 20 5 16 25 3mm BASE PLATE 25 M6 CLEAR

Slimline Enhancements 01.17 page 50 Keep plates for morticed and surface-mounted systems Available in heavy-section steel with a zinc-plated finish, or from polished stainless steel (add suffix - 'S' to your ordering code). This range of keeps is primarily designed for use with morticed systems. On timber frames the keeps can be recessed flush with the frame. On metal frames they can be fixed to reinforce a thin section prior to frame installation. SB Keep plate with snib Designed to be recessed into timber frames with doors which have been fitted with a morticed system. The snib protects the frame from any accidental damage or undue wear by the bolt. No 10 screw 25 75 30 8.5 5 SB1 Keep plate without snib Designed to reinforce metal frames with doors which have been fitted with a morticed system or with outward-opening doors fitted with a surface mounted system. No 10 screw 30 575 SB2 Off-centre keep plate without snib Designed to reinforce steel frames with outward-opening doors that have been fitted with a surface-mounted system. This reduces the amount of packing which may otherwise be necessary under a system. No 10 screw 4 30 575 SB4 Keep plate with snib and strike button Designed for the top vertical bolt of a mortice fitted device hung in a timber frame. Door thickness up to 50mm. No 10 screw 25 90 30 10 5 SB6 Keep plate with snib and strike button Designed for the top vertical bolt of a mortice fitted device hung in a timber frame. Door thickness up to 60mm. No 10 screw 25 90 30 13.6 5

Slimline Enhancements 01.17 page 51 Outward-opening frame keeps for surface-mounted systems Made from heavy-section steel with a grey-white RAL 9002 leatherette powder coating finish as standard, or from polished stainless steel (add suffix -'S' to your ordering code). SC Outward-opening timber frame keep Designed for use on timber frames with an outward-opening door. No 12 SCREWS 110 22 3 50 SC1 Outward-opening timber frame keep and strike Designed for use with the auto-bolting feature on an outward-opening door hung in a timber frame. The striker releases the restraint mechanism allowing the bolts to fire into their keeps, thus providing a slam-shut facility. No 12 SCREWS 18 25 50 110 3 SC2 Outward-opening steel frame keep and strike Designed for use with the auto-bolting feature on an outward-opening door hung in a steel frame. The striker releases the restraint mechanism allowing the bolts to fire into their keeps, thus providing a slam-shut facility. Can also be used as an alternative on a timber frame in place of SC1. No 12 SCREWS 110 5 51 25 SC8 Outward-opening timber/steel frame keep Designed for use on both timber and steel frames with an outward opening door.

Slimline Enhancements 01.17 page 52 Inward-opening frame keeps for surface mounted systems Made from heavy-section steel with a grey-white RAL 9002 leatherette powder coating finish or from polished stainless steel (add suffix -S to your ordering code), these keeps are suitable for surface-mounted systems on inward-opening doors with timber frames. SA Frame keep and base plate Designed to receive the horizontal bolt on an inward- or outward-opening door hung in a steel frame. 73 M6 CLEAR 25 SD Inward opening timber frame keep Designed for use with an inward-opening door hung in a timber frame. No 10 SCREWS 63 3 26 19 110 3 5 20 Floor keeps Made from heavy-section stainless steel, this keep is suitable for morticed or surface-mounted systems and inward- or outward-opening doors. SF Dust excluding floor socket This keep is fitted with a sprung plunger which returns to a flush-floor position, reducing the amount of dust and grit often associated with normal floor sockets. 6 n50 49 n28 SE Easy cleaning floor socket 110 This keep enables dust and grit to be easily swept clean. 21 30 Alternative receiving keeps are available for the lower vertical bolt, to suit various site conditions, and are illustrated below. SA SB SB1 SB2 SC SD

Slimline Popular Enhancements 01.17 page 53 Slimline self creating coding system: Popular Enhancement Chart Four steps to Slimline Step 1 Step 2 Step 3 Step 4 Example system code: SL 3 1 5-04 - N P W Number of bolts 2 2-point securing 3 3-point securing 4 4-point securing On double doors specify each leaf separately. Entry 0 No entry provision 1 Key and handle entry 2 Electric release and handle entry 3 Combination lock release and handle entry Exit 0 No exit provision 1 Key and handle exit 2 Electric release and handle exit 3 Turnknob release and handle exit 4 Panic exit 5 Emergency exit handle Enhancements Customise to suit specific requirements. Codes A to Z. The above code SL315-04-NPW specifies a Slimline 3-point device, with external key entry, emergency exit release and lever handle both sides. The enhancement codes specify electric monitoring of lock status (N), a cylinder guard (P) and steel core fixing (W). Note: The code 04 specifies right hand outward opening (refer to the handing chart below for the various differs). DEVICE CODINGS 6 Push pad POPULAR ENHANCEMENTS - if required (for detailed information see descriptions below) FIXINGS BOLTING ENTRY ENTRY DESCRIPTION 0 4 Bolting - Panic Exit; BS EN 1125: 2008; panic bar 0 5 Bolting - Emergency Exit; BS EN 179: 2008; internal lever handle 0 6 Bolting - Emergency Exit; BS EN 179: 2008; internal push pad A 0 E(n) H 3 K K 0 K 2 K 17 L L 1 L 2 M M 7 N O 0 O 1 O 2 O 5 O 9 O 10 O 91 P P 5 S W W 2 W 3 DEADLOCKING 0 1 Deadlocking; internal key and handle release 1 0 Deadlocking; external cylinder; stainless steel lever handle outside only; no exit facilities 1 1 Deadlocking; external cylinder; internal cylinder keyed-alike; stainless steel lever handle both sides 1 3 Deadlocking; external cylinder; internal turnknob release; stainless steel lever handle both sides 1 4 Deadlocking; external cylinder; internal panic bar exit (option X facility built-in); BS EN 1125: 2008 1 5 Deadlocking; external cylinder; internal lever handle emergency exit (option X facility built-in); BS EN 179: 2008 1 6 Deadlocking; external cylinder; internal push pad emergency exit (option X facility built-in); BS EN 179: 2008 2 0 2 1 Deadlocking electric lock; 12V solenoid - energise to unlock (fail secure); stainless steel lever handle outside only; no exit facilities Deadlocking; electric lock; 12V solenoid - energise to unlock (fail secure); stainless steel lever handle both sides; internal key release 2 2 Deadlocking; electric lock; 12V solenoid - energise to unlock (fail secure); stainless steel lever handles both sides 2 3 2 4 2 5 2 6 Deadlocking; electric lock; 12V solenoid - energise to unlock (fail secure); internal turnknob release; stainless steel lever handles both sides Deadlocking; electric lock; 12V solenoid - energise to unlock (fail secure); external stainless steel lever handle; internal panic bar exit (option X facility built-in); BS EN 1125: 2008 Deadlocking; electric lock; 12V solenoid - energise to unlock (fail secure); external stainless steel lever handle; internal lever handle emergency exit (option X facility built-in); BS EN 179: 2008 Deadlocking; electric lock; 12V solenoid - energise to unlock (fail secure); external stainless steel lever handle; internal push pad emergency exit (option X facility built-in); BS EN 179: 2008 3 0 Deadlocking; S&G 8550 combination lock; stainless steel lever handle outside only; no exit facilities 3 5 Deadlocking; S&G 8550 combination lock; stainless steel lever handle entry; internal green lever handle emergency exit (option X facility built-in); BS EN 179: 2008 Enhancement code descriptions: A 0 Manual bolting E(n) Height increment above 2200mm; (n) = number of 1000mm increments H 3 Push pad; in lieu of standard internal operation K Key retained in unlocked position K 0 Manual locking External key release in case of power failure K 2 K 4 K 17 Break-dome over turnknob Kaba Mas Auditcon 552 electric lock L LEO - external key-entry lock with internal emergency override - surface mounted L 1 Recessed LEO (flush fitting) with cylinder guard - tested to LPS 1175 rating 4 protection M Electronic monitoring of bolt status Motorised bolt release M 7 N O 0 O 1 O 2 O 5 O 9 O 10 O 91 Electronic monitoring of lock status Customers own cylinder supply (free issue) Kaba-20 cylinder (registered) Assa Twin Combi 5800 cylinder (registered) Medeco m 3 -ARX (registered) Abloy Disklock Pro cylinder (registered) Kaba quattro plus cylinder (registered) Abloy Protec (registered) P Cylinder guard for thickness 44-60mm - tested to LPS 1175 rating P 5 Cylinder guard for thickness 44-60mm - tested to LPS 1175 rating S Stainless Steel 316 W Steelcore fixing with machine screws W 2 Surface fixing by coach screws Surface fixing by machine screws W 3 Popular enhancements Available enhancements Dependant on other enhancement(s) - refer to Slimline catalogue Other dependant enhancements

Slimline - Full list of Enhancements available Slimline Full List - Enhancements Slimline 01.17 page Full 54 List - Enhan Slimline Entry/Exit Codes Slimline Entry/Exit Codes Enhancements 2-304 2-305 2-306 2-301 2-310 2-311 2-313 2-314* 2-315* 2-316* 2-320 2-321 2-322 2-323 2-324* 2-325* 2-326* 2-330* 2-335* 405 Code Description A 0 Manual bolting A 3 Auto-bolting sliding doors B(n) Packing; (n) = number of 1mm increments E(n) Height increment above 2,200mm; (n) = number of 1,000mm increments H External stainless steel lever handle addition (non lockable) handle addition (non lockable) H 0 Handle(s) not included H 3 Push pad; in place of inside handle H 9 Handles not included; with 8mm follower H 11 1M long panic bar K Key retained in unlocked position K 0 Manual locking K 2 External key release in case of power failure K 4 Break-dome over turnknob K 6 Lockable in the retracted position only (function according to system type) K 7 Lockable in thrown and retracted position (function according to system type) K 8 Automatic ratchet locking upon bolt retraction - internal key re-set facility K 12 Euro-profile cylinder in place of rim-latch style cylinder K 14 Manual lock-back facility, bolting only (internal Euro-profile cylinder) K 15 Shrouded turnknob K 17 Kaba Mas Auditcon 552 electronic lock K 22 S&G 2740 electro-mechanical lock L LEO - external key-entry lock with internal emergency override - surface mounted L 1 Recessed LEO (flush fitting) - tested to LPS 1175 rating 3 protection L 2 Recessed LEO (flush fitting) with cylinder guard - tested to LPS 1175 rating 4 protection L 3 LEO with Euro-profile cylinder - external key-entry lock with internal emergency override - surface mounted L 4 Recessed LEO (flush fitting) with Euro-profile cylinder - tested to LPS 1175 rating 3 protection L 5 Recessed LEO (flush fitting) with Euro-profile cylinder and cylinder guard - tested to LPS 1175 rating 4 protection tested to LPS 1175 rating 4 protection M M 7 N O 0 O 1 O 2 O 3 O 4 O 5 O 6 O 9 O 10 O 22 O 91 P Electric monitoring of bolt status Motorised bolt release Electric monitoring of lock status Cylinder - supplied free-issue (approved types and factory fitted only) Cylinder - Kaba-20 (registered) Cylinder - Assa Twin Combi 5800 (registered) Cylinder - Yale Cylinder - Bramah (registered) Cylinder - Medeco m 3 -ARX (registered) Cylinder - Ingersoll (registered) Cylinder - Abloy Disklock Pro cylinder (registered, gold level) Cylinder - Kaba quattro plus (registered) Cylinder - Assa Ruko Flexcore (choice for registration) Cylinder - Abloy Protec (registered, diamond level) Cylinder guard for door thickness 44-60mm - tested to LPS 1175 rating 3 protection P 2 Cylinder guard S-8374 for door thickness of 50 to 56mm only suitable for Ingersoll cylinder option 0 6 P 3 Cylinder guard S-8374 for door thickness of 44 to 49mm only suitable for Ingersoll cylinder option 0 6 P 4 P 5 P 6 Q 4 R 1 R 2 R 3 R 4 R 7 S T T 1 U U 1 V V 1 V 2 W W 2 W 3 W 8 W 9 Y 0 Z Z 0 Cylinder guard to take Euro profile cylinder - tested to LPS 1175 rating 3 protection Cylinder guard for door thickness 44-60mm - tested to LPS 1175 rating 4 protection Cylinder guard for door thickness 44-60mm - tested to LPS 1175 rating 5 protection Resistance to end load Access control (energise to unlock) 24 volt solenoid Access control (energise to lock) 12 volt solenoid Access control (energise to lock) 24 volt solenoid Access control (energise to unlock) 50 volt solenoid Access control (energise to lock) 50 volt solenoid Stainless steel 316 - finish polished Slave unit, 90 deg. below handle Slave unit, 90 deg. above handle Slave unit, 90 deg. & continue, below handle Slave unit, 90 deg. & continue, above handle VIP (Visual Indicator Panel) VIP (Visual Indicator Panel) with electric monitoring of indicator & isolation keyswitch VIP (Visual Indicator Panel) with electric monitoring of indicator Machine screws with steel dowels Surface fixing by coach screws Surface fixing by machine screws Mortice fixing pack with guides - timber doors Mortice fixing pack with guides - steel doors Single leaf - non BSEN type device Double doorset active leaf - BSEN type device Double doorset active and passive leaves - non BSEN type device Dependant on other enhancement(s) Options non-conformant with BSEN 179 and BS EN 1125 certification * Handing required

ments P1 10.13 Slimline Standard Packages 01.17 Fast track delivery, ready to fit Slimline multi-point Standard Packages are delivered ready to install. The packages are commonly selected configurations from the Slimline range. Fixings and keeps are included for an outward opening steel or timber core door, hung in a steel or timber frame and a concrete floor. Note: Separate keeps are available for inward opening doors (see Additional Items ). Slimline Standard Packages include for Safe exits Key release entry Electric release entry Slimline Standard Packages are Easy to order Suitable for steel and timber doorsets Suitable for door heights of up to 2200mm High Performance Robust, offering long trouble free life Independently tested to 200,000 cycles In-house testing to over one million cycles 96hrs-240hrs salt spray testing Slimline devices have been successfully tested to LPS 1175 Security Rated 2, 3, 4, & 5 doorsets Successfully blast tested on doors in accordance with the methodology set out within ISO 16933 EXV15 & EXV25, utilising the hazard rating as defined for Walls and Doors Simply a Lock-in-a-box, the complete package Safe exits conforming to the 2008 revision of European standards BS EN 1125: 2008 and BS EN 179: 2008, CE marked. A Lock-in-a-box Slimline Standard Packages Slimline Standard Packages page 55

Slimline Standard Packages 01.17 page 56 Slimline Standard Packages The security of buildings and assets, combined with the safety of people at work, is a necessity in todays world of crime and terrorism. Standards have been developed to measure the ability of doors and devices to meet many of the perceived threats. Surelock products have been successfully tested against the extremes of physical attack, providing the strength and resilience needed for high performance fire, blast and ballistic protection doors, combining performance with the choice of operational functionality to suit most applications. The modular design of Slimline provides a common fixing footprint and key cylinder position, enabling alternative modules to be retrofitted to meet changes of a customer s operational requirement. Slimline Features 15mm hardened steel bolts each with 25mm throw Positive engagement Easily adjusted Steel drilling template provides for accurate installation Suitable for door heights up to 2200mm Bolts Securing 2-point - Two vertical bolts securing into the head and floor, typically for a single leaf or double leaf doors with plain meeting stiles. 3-point - Two vertical bolts securing into the head and floor, plus a single horizontal bolt securing into the leading frame jamb. 4-point - Two vertical bolts securing into the head and floor, plus two horizontal bolts securing into each of the frame jambs. 5-point - Three horizontal bolts form the active leaf and securing across to the passive leaf, whilst the passive leaf is secured top and bottom by two vertical bolts. This enables either of the panic bars to be operated to gain a safe exit. Meeting Your Duty of Care with Confidence The safety of people within a building is paramount today - safety requirements have to be met in public buildings, places of work, secure institutions etc. Standards have evolved to measure the ability of doors and devices to meet safety requirements. Slimline standard packages ensure that emergency and panic exits can also meet your security requirements.these offer wide ranging high security certification including conformance to blast, ballistics and other hostility standards. The latest European standards for panic and emergency exits have been updated to the 2008 revision, to ensure maximum safety. Slimline products provide you with the best products, together with full certification and CE marking to BS EN 1125: 2008 for panic exits and BS EN 179: 2008 for emergency exits. Total confidence and conformance to the latest safety requirements is assured. A 'Lock - in a Box'

Slimline Standard Packages 01.17 page 57 Safe Exits The choice of Slimline safe exit devices cater for both single and double leaf doors, with 2-, 3-, 4- and 5-point bolt securing. The choice of exit operation includes panic bar, lever handle or push pad, all independently type tested to the latest European certification and CE marked. SLP204 SLP304 SLP305 SLP405 SLP504 Extracts from the standards: BS EN 1125: 2008 (panic exit) for use on escape routes in public areas, public buildings, places of public entertainment, shops etc., or those that have to be operated in a panic situation. BS EN 179: 2008 (emergency exit) For use on escape routes where people are familiar with the exit and its hardware and therefore a panic situation is most unlikely to develop. Package code Door leaves Bolts securing Exit operator Exit certification CE marked SLP204 Single* 2 Panic bar BS EN 1125: 2008 SLP304 Single 3 Panic bar BS EN 1125: 2008 SLP305 Single 3 Lever handle BS EN 179: 2008 SLP405 Single 4 Lever handle BS EN 179: 2008 SLP504 Double 5 Panic bars (2) BS EN 1125: 2008 *2 No SLP204 are suitable for use on a pair of non-rebated double doors, securing each door leaf at the top and bottom.

Slimline Standard Packages 01.17 page 58 Key Release Slimline key release packages provide external key entry, with a lever handle to retract the multiple bolts, permitting the door to be opened. Automatic re-securing upon door closure ensures maximum security at all times. Key release packages include a Union 5 pin cylinder complete with two keys. The choice of exit methods include: SLP313 SLP314 SLP315 Indicates handing item, refer to handing chart below * * * When fitted with 'option K' Product Codes: Package code Door leaves Bolts securing SLP313 Single 3 SLP314 Single 3 SLP315 Single 3 Entry operator Exit operator Exit certification Key and lever handle Key and lever handle Key and lever handle Turnknob and lever handle Panic bar BS EN 1125: 2008 UL305 CE marked Lever handle BS EN 179: 2008

Slimline Standard Packages 01.17 page 59 Electric Release Slimline electric release packages provide for external access control entry, with a lever handle to retract the multiple bolts. permitting the door to be opened. Automatic re-securing upon door closure ensures maximum security at all times. Electric release packages include a solenoid, energised to unlock (fail secure), rated at 12 V, 6.3 W (0.53 A). The choice of exit methods include: SLP322 SLP324 SLP325 Indicates handing item, refer to handing chart below * * * When fitted with 'option K' Product Codes: Package code Door leaves Bolts securing SLP322 Single 3 SLP324 Single 3 SLP325 Single 3 Entry operator Exit operator Exit certification Access control and lever handle Access control and lever handle Access control and lever handle Access control and lever handle Panic bar BS EN 1125: 2008 UL305 CE marked Lever handle BS EN 179: 2008

Slimline Standard Packages 01.17 page 60 Slimline Standard Packages Keeps and Fixings - Slimline standard packages are supplied with fixings and keeps suited for an outward opening steel or timber core door, hung in a steel or timber frame and a concrete floor. SC8 Outward opening frame keep SC2 Outward opening frame keep and strike SF Dust excluding floor keep Coach screw fixing for timber doors Machine screw fixing for steel doors Additional Items (to be ordered separately, if required) Inward opening keeps - alternative keeps are available within the Slimline range to suit inward opening doors, these need to be selected to suit the frame detail and ordered separately. SA-W3 Inward opening steel frame keep SD Inward opening timber frame keep LEO (Lock with Emergency Override) - surface mounted lockable handle providing key entry on a Safe Exit door. A Union 5 pin Euro-profile cylinder enables on-site cylinder change-over to a customer s specific cylinder make or suiting, complete with two keys. S-11330-05 Surface mounted LEO (Lock with Emergency Override), left hand shown Ordering codes: S-11330-04 (right hand) S-11330-05 (left hand) Rim cylinder - Union 5 pin rim cylinder to provide key entry in case of power failure on electric release devices, complete with two keys. S-11303 Rim cylinder, complete with two keys Ordering code: S-11303

Slimline Standard Packages 01.17 page 61 Slimline Standard Packages Ordering codes explained Slimline multi-point Standard Packages are delivered ready to install. The packages are commonly selected configurations from the Slimline range. Fixings and keeps are included for an outward opening steel or timber core door, hung in a steel or timber frame and a concrete floor. SLP Slimline Package Step 1 Step 2 Step 3 Choose the number of bolts securing (2, 3 or 4) Choose how you wish to enter Choose how you wish to exit Note: Panic and emergency exit deadlocking devices are handed, refer to the handing chart and ordering example below for ordering clarification. Entry Exit No entry Key driven Electric release Combination lock Code 0 1 2 3 No exit Key driven Electric release Turnknob release Code 0 1 2 3 Emergency exit 5 Example system code: SLP 3 2 5-04 The above code SLP325-04 refers to a Slimline 3-point securing electric release entry device, with a single handed emergency exit operation, conforming to BS EN 179: 2008, CE marked. 04 refers to a right hand device. Surelock s aspirations to provide customers with the correct solution to meet an ever expanding complexity of operational requirements have once again proven to be successful. If you have a specific operational requirement, no matter how complex, we are pleased to provide a solution. Intellectual Property Rights All Surelock products are the subject of intellectual property rights. These rights include patent and design rights, in particular UK patents 2289084, 2307270, 2321277, 2323272, 2330375, 2346927, 2351542, 2355282, 2359111, 2361959, 2364740, 2413822, 2423787, 2425325, 2462229 & 2462387, plus UK patent applications 2445948 & 2458893 together with overseas patents and applications. In accordance with our policy of continual development and improvement we reserve the right to make changes in design and specifications without notice.