M9208-xxx-x Series Electric Spring Return Actuators

Similar documents
M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

Electric Rotary Actuator - On/Off or programmable control actuator

Installation Instructions

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

Duct Humidity Transmitter

P70, P72, and P170 Series Controls for Dual Pressure Applications

HERZ-Thermal Actuators

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

MP8000 Series Pneumatic Valve Actuators

Air damper actuators

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

System 350 A350E Electronic Cooling Control

Telefon (+45) Telefax (+45) Installation and operating manual

Electronic Control Devices The European Product Catalogue 2007

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

FX07 Field Controller

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

TorqPlus TM Electric Valve Actuators and Controls

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Digital input modules

P66 Series Electronic Fan Speed Controls

T5000 T000 LCD Digital Fan Coil Thermostat

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Input/Output Module (IOM) Series Controllers Catalog Page Code No. LIT Issued April 17, 2015

How To Drive A Compact Serie 1

POWERS Controls No. 4 Pneumatic Damper Actuator

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Advantium 2 Plus Alarm

Power Supplies 3. SDN-P DIN Rail Series

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

A99B Series Temperature Sensors

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

This chart is intended for selection purposes only. For complete product application information, refer to individual product specification sheets.

Know-how makes the difference. Electrical Actuators

SPEED CONTROL SYSTEM

IO-RM3 3-Stage Relay Module

Series 71, 72, and 76 Modutrol IV Motors

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

38 Series - Relay interface modules A

Electronic Control Devices The European Product Catalogue 2007

System 350 A350R Electronic Temperature Reset Control (with Relay)

38 Series - Relay interface modules A

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

DUCT SMOKE DETECTOR D4120

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

English plain text messages with constant backlight that brightens during user interaction. On/Off, Floating, or Proportional 0 to 10 VDC Control

Absolute Rotary Encoder E6CP

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Borstlösa DC-motorer. Promoco Scandinavia AB

Protects against unwanted thermostat controller tampering. Increases occupancy comfort by providing dehumidification.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

MDC Series

CQM1-SF200/CS1W-SF200

Power consuption Motor (Motion) Power consuption Standby (end position) 1,0 W. Position feedback - Switching point

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Fire Pump Controllers Remote Alarm Panels

T7560A,B,C Digital Wall Module

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

MCR1900 Media Converter 19-Slot Chassis

Quick running actuator

Electronic, Digital and Mechanical Vibration Switches

FIRERAY 2000 Installation Guide

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

Model: DC-A2IO Advanced HVAC Controller

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

VG7000 Series Bronze Control Valves

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Description. Dimensions. Features. precision works better

RM4TG20 three-phase network control relay RM4-T - range V

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

RY2 miniature industrial relays

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

48 SERIES Relay interface modules 10 A

Digi-Motor Installation Guide

T7079A,B Solid State Remote Temperature Controllers

Product and functional description

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Transcription:

M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin M9208-GGx-x, M9208-AGx-x, M9208-Bxx-3 Code No. LIT-12011480 Issued May 2016 The M9208-xxx-x Series Electric Spring Return Actuators provide control of dampers in Heating, Ventilating, and Air Conditioning (HVAC) systems. All actuators in this series provide 70 lb in (8 N m) rated torque. A mechanical spring return system provides rated torque with and without power applied to the actuator. The series includes the following control options: On/Off, 24 V, 120 VAC, 230 VAC power On/Off and Floating Point, 24 V power Proportional, 24 V power, for 0(2) to 10 VDC or 0(4) to 20 ma Control Signal These actuators are configured for direct mounting and do not require a damper linkage. Actuators can be mounted directly to a damper shaft from 5/16 to 5/8 in. (8 to 16 mm) diameter with a universal clamp. For shafts up to 3/4 in. (19 mm) diameter use the accessory Large Shaft Coupler Kit M9208-600. An accessory crankarm and remote mounting kit are available for applications where the actuator cannot be direct-coupled to the damper shaft. Optional line voltage auxiliary switches indicate an end-stop position or perform switching functions within the selected rotation range. Refer to the QuickLIT Web site for the most up-to-date version of this document. Figure 1: M9208-xxx-x Series Electric Spring Return Actuator Table 1: Features and Benefits (Part 1 of 2) Features Benefits 70 lb in (8 N m) Rated Torque Provides high torque in a compact package size to expand the range of damper applications in HVAC systems. Direct-Coupled Design Requires no crankarm or linkage and is capable of direct mounting to a shaft up to 3/4 in. (19 mm) diameter and centered on a 1/2 in. (13 mm) shaft. Reversible Mounting Provides either clockwise or counterclockwise operation. Electronic Stall Detection Protects from overload at all angles of rotation. Power consumption is reduced in holding mode. The actuator may be stalled anywhere in its rotation range without the need for mechanical end switches. Double-Insulated Construction Allows that electrical ground connection is not necessary for regulatory agency compliance. Microprocessor-controlled Provides constant runtime independent of torque. Brushless DC Motor (-AGx and -GGx types) External Mode Selection Switch (-AGx and -GGx types) Permits control logic reversal for Floating Control (-AGx types). Permits calibration, input signal range selection, and control logic reversal for Proportional Control (-GGx types). M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin 1

Table 1: Features and Benefits (Part 2 of 2) Benefits Features Locking Manual Override with Auto Release and Crank Storage Override Control (Proportional Model Only) Integral Cables with Colored and Numbered Conductors Integral Connectors for 3/8 in. (10 mm) Flexible Metal Conduit (FMC) Optional Integrated Auxiliary Switches UL, CE, and C-Tick Compliance Manufactured under International Standards Organization (ISO) 9001 Quality Control Standards 5-Year Warranty Allows manual positioning of the actuator hub with automatic return to normal operation when power and control signal are restored. Supports control system override applications through field wiring. Simplify installation and field wiring. Simplify installation and field wiring. Provide two integrated, line-voltage-capable Single-Pole, Double-Throw (SPDT) switches with one fixed and one adjustable switch point. Facilitates safety interfacing or signaling. Provides internationally recognized regulatory agency approvals. Ensures quality. Protects consumer investment. Application IMPORTANT: Use these M9208-xxx-x Series Electric Spring Return Actuators only to control equipment under normal operating conditions. Where failure or malfunction of the electric actuator could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the electric actuator. IMPORTANT: Before specifying M9208-xxx-x Series Electric Spring Return Actuators for plenum applications, verify acceptance of exposed plastic materials in plenum areas with the local building authority. Building codes for plenum requirements vary by location. Some local building authorities accept compliance to UL 1995, Heating and Cooling Equipment, while others use different acceptance criteria. M9208-GGx-x Series Proportional Actuators For proportional modulation of dampers requiring up to 70 lb in. (8 N m) in HVAC systems that are controlled by an electronic controller or positioner. The actuator responds to 0 to 10 VDC, or 2 to 10 VDC control signals. With the addition of a 500 ohm resistor, the actuator responds to a 0 to 20 ma, or 4 to 20 ma signal. A 0 to 10 VDC, or 2 to 10 VDC feedback signal indicates position and provides support for master-slave applications. The M9208-GGA-2 actuators include plenum-rated cables and are specially configured for installation in spaces used for environmental air-handling purposes, other than ducts and plenums, as specified in National Fire Protection Association (NFPA) 70: National Electrical Code section 300.22(C), Other Space Used for Environmental Air. The space over a hung ceiling, when used for environmental air handling purposes, is an example of the type of space for which these actuators are configured. M9208-AGx-x Series On/Off and Floating Point Actuators For on/off control or modulation of dampers requiring up to 70 lb in. (8 N m) in HVAC systems. Floating point control can be provided from a triac or relay. On/off control can be provided from a manual switch, controller, auxiliary switch from a fan motor contactor, or similar device. The M9208-AGA-2 actuators include plenum-rated cables and are specially configured for installation in spaces used for environmental air-handling purposes other than ducts and plenums as specified in National Fire Protection Association (NFPA) 70: National Electrical Code section 300.22(C), Other Space Used for Environmental Air. The space over a hung ceiling, when used for environmental air handling purposes, is an example of the type of space for which these actuators are configured. 2 M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin

M9208-Bxx-3 Series On/Off Actuators For on/off control of dampers requiring up to 70 lb in. (8 N m) in HVAC systems. On/off control can be provided from a manual switch, controller, auxiliary switch from a fan motor contactor, or similar device. Operation M9208-xxx-x Series actuators provide 95º of rotation. A graduated scale from -5º to 90º and a position indicator provide visual indication of stroke. A manual override allows manual positioning and temporary locking of the actuator output hub. Restoring power and control signal to the actuator automatically releases the manual override the first time the actuator is commanded to advance past the locked position. During installation, the installer can advance the spring and mount the actuator to provide positive close-off on air-tight damper applications. When power fails during service, the mechanical spring return system provides rated torque to the connected equipment, returning it to the home position. M9208-GGx-x Series Proportional Actuators The M9208-GGx-x Series uses a brushless DC motor controlled by a microprocessor. The microprocessor drives the motor at constant speed, independent of torque. The microprocessor also monitors the brushless DC motor s rotation to prevent damage to the actuator in a stall condition. The actuator can be stalled anywhere within its rotation range without the need for mechanical end switches. Power consumption is reduced in the holding mode. The M9208-GGC-3 version is provided with two integrated, line-voltage-capable auxiliary SPDT switches. The Switch S1 switch point is fixed at 11º closing, while the Switch S2 switch point is independently and continuously adjustable from 25º to 90º. Auxiliary switches are double-insulated so an electrical ground is not required. M9208-AGx-x Series On/Off and Floating Point Actuators The M9208-AGx-x Series uses a brushless DC motor controlled by a microprocessor. The microprocessor drives the motor at constant speed, independent of torque. The microprocessor also monitors the brushless DC motor's rotation to prevent damage to the actuator in a stall condition. The actuator can be stalled anywhere within its rotation range without the need for mechanical end switches. Power consumption is reduced in the holding mode. The M9208-AGC-3 version is provided with two integrated, line-voltage-capable auxiliary SPDT switches. The Switch S1 switch point is fixed at 11º closing, while the Switch S2 switch point is independently and continuously adjustable from 25º to 90º. Auxiliary switches are double-insulated so an electrical ground is not required. M9208-Bxx-3 Series On/Off Actuators The M9208-Bxx-3 Series uses a DC brush motor controlled by analog electronics. The actuator can be stalled anywhere within its rotation range without the need for mechanical end switches. Power consumption is reduced in the holding mode. Three different voltage ratings are available for On/Off Actuators. M9208-BGx-3: AC 24 V 50/60 Hz or DC 24 V power M9208-BAx-3: AC 120 V 50/60 Hz power M9208-BDx-3: AC 230 V 50/60 Hz power The M9208-BAx-3 and M9208-BDx-3 actuators are double-insulated so an electrical ground is not required. The M9208-BxC-3 versions are provided with two integrated, line-voltage-capable auxiliary SPDT switches. The Switch S1 switch point is fixed at 11º closing, while the Switch S2 switch point is independently and continuously adjustable from 25º to 90º. Auxiliary switches are double-insulated so an electrical ground is not required. M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin 3

Wiring Diagrams M9208-GGx-x Series Proportional Actuators DC 0(2)...10 V Control BLK RED GRY ORN 0(4)...20 ma Control with External Resistor Override to MIN position Override to MAX position AC/DC 24 V ~() DC 0(2)...10 V Y DC 0(2)...10 V COM BLK U RED GRY ORN COM AC/DC 24 V ~() 0(4)...20 ma 500 / 0.25 W Master-Slave Application Y DC 0(2)...10 V U AC 24 V ~ A DC 0(2)...10 V COM A Open = MIN Position A Closed = Normal Operation Y DC 0(2)...10 V U COM B AC C 24 V ~ DC 0(2)...10 V Y DC 0(2)...10 V U B Closed = MAX Position C Closed = Normal Operation COM AC/DC 24 v ~() DC 0(2)...10 V Y DC 0(2)...10 V Figure 2: M9208-GGx-x Control Wiring Diagrams U FIG:M9xxx-GGx_cntrlwir_PB Override to MIN, MID, MAX positions 0(4)...20 ma Control with External Resistor Override to MIN, MID, MAX positions 0(2)...10 V Control BLK RED GRY ORN M9208-GGx-x Control Wiring Diagrams IMPORTANT: Do not install multiple M9208-GGx-x Series Actuators connected to the same mechanical load. Master-slave application of M9208-GGx-x Series Actuators requires that each actuator be connected to independent loads. Note: In master-slave applications, the slave actuator lags the master actuator position by a few seconds. COM AC 24 V ~ A B 0(4)...20 ma C 500 Ω / 0.25 W Y U COM AC 24 V ~ DC 0(2)...10 V A B C Y U FUNCTION A B C FUNCTION A B C 0% ( MIN ) 50% ( MID ) 100% ( MAX ) NORMAL 0% ( MIN ) 50% ( MID ) 100% ( MAX ) NORMAL FIG:M9203GGx2(Z)_wir Figure 3: M9208-GGx-x Control Wiring Diagram (Overrides) 4 M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin

FIG:M92xx-Bxx-2S_wiring M9208-Bxx-3 Series On/Off Actuators BLK RED 1 2 M9208-xxx-x Auxiliary Switches S1 S2 21 22 24 25 23 26 21 24 BLK/ BLK/ BLK/ WHT/ WHT/ WHT/ RED BLU GRY RED BLU GRY 21 22 23 24 25 26 - ~ AC 24 V 50/60 DC 24 V WHT BLK 1 2 BLU 1 BRN 2 COM NC NO COM NC NO FIG:xxC_Switch_Wiring Figure 6: M9208-xxx-x Auxiliary Switch Wiring Diagram N L1 AC 120 V 60 Hz N L1 AC 230 V 50/60 Hz Figure 4: M9208-Bxx-3 Control Wiring Diagrams M9208-AGx-x Series On/Off and Floating Point Actuators Floating Control, Four Wire RA RA DA DA Open/Close, Single Wire Control RA RA DA DA FIG:M92xx-AGx_cntrlwir_PB Repair Information A number of replacement parts are available; see Table 3 for more details. If an M9208-xxx-x Series Electric Spring Return Actuator fails to operate within its specifications, replace the unit. For a replacement electric actuator, contact the nearest Johnson Controls representative. - ~ 24 VAC 24 VDC - ~ 24 VAC 24 VDC On/Off Control, Two Wire Floating Control, Multiple Actuators with One Transformer RA RA DA DA RA RA DA DA RA RA DA DA - ~ 24 VAC 24 VDC - ~ 24 VAC 24 VDC Figure 5: M9208-AGx-x Control Wiring Diagrams M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin 5

Ordering Information Table 2: M9208-xxx-x Series Electric Spring Return Actuator Models Code Number Rotation Time For 90 Power Requirements Power Consumption Input Signal Position Feedback Auxiliary Switches Electrical Connection (Spring Return) 24 VAC /- 25%, VDC 20%/-10% 24 VAC /- 20%, VDC 20%/-10% 120 VAC /- 10% 230 VAC /- 10% VA Rating, Transformer Sizing VA: Running (Holding) Amperage: Running (Holding) On/Off Floating Point 0(2) to 10 VDC 0(4) to 20 ma (with 500 ohm Resistor) 0(2) to 10 VDC 2 SPDT, 5.0 A (2.9 A Inductive) at 240 V 48 in. (1.2 m) 18 AWG Appliance Cable 120 in. (3.05 m) 19 AWG Plenum Cable Integral 3/8 in. (10 mm) FMC Connectors M9208-AGA-2 150 17 to 25 1 x 8 7.9 (5.5) - x x x x M9208-AGA-3 150 17 to 25 1 x 8 7.9 - x x x x (5.5) M9208-AGC-3 150 17 to 25 1 x 8 7.9 (5.5) - x x x x x M9208-BGA-3 55 to 71 13 to 26 2 x 7 6.1 - x x x (1.2) M9208-BGC-3 55 to 71 13 to 26 2 x 7 6.1 (1.2) - x x x x M9208-BAA-3 55 to 71 13 to 26 2 x - -.05 x x x (.03) M9208-BAC-3 55 to 71 13 to 26 2 x - -.05 (.03) x x x x M9208-BDA-3 55 to 71 13 to 26 2 x - -.04 x x x (.03) M9208-BDC-3 55 to 71 13 to 26 2 x - -.04 (.03) x x x x M9208-GGA-2 150 17 to 25 1 x 8 7.9 (5.5) - x x x x M9208-GGA-3 150 17 to 25 1 x 8 7.9 - x x x x (5.5) M9208-GGC-3 150 17 to 25 1 x 8 7.9 (5.5) - x x x x x 1. 22 seconds nominal at room temperature and rated load, 94 seconds maximum at rated load and -40ºF (-40ºC) 2. 21 seconds nominal at room temperature and rated load, 39 seconds maximum at rated load and -4ºF (-20ºC), 108 seconds maximum at 53 lb in. (6 N m) and -40ºF (-40ºC) 6 M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin

Table 3: Accessories and Replacement Parts (Order Separately) Code Number Description DMPR-KC003 1 7 in. (178 mm) Blade Pin Extension (without bracket) for Johnson Controls Direct-Mount Damper Applications (quantity 1) M9000-200 Commissioning Tool that provides a control signal to drive 24 V On/Off, Floating, Proportional, and/or Resistive Electric Actuators (quantity 1) M9000-321 Weathershield Kit for Damper Application of M9203 and M9208 Series Electric Spring Return Actuators (quantity 1) M9000-400 Jackshaft Linkage Kit. Open-ended design enables clamping onto a jackshaft without requiring access to the ends of the jackshaft (quantity 1) M9000-560 Ball Valve Linkage Kit for applying M9203 and M9208 Series Electric Spring Return Actuators to VG1000 Series Valves (quantity 1) M9000-604 Replacement Anti-Rotation Bracket Kit for M9208, M9210, and M9220 Series Electric Spring Return Actuators (quantity 1) M9000-606 Position Indicator for Damper Applications of M9203 and M9208 Series Actuators (quantity 5) M9200-100 Threaded Conduit Adapter, 1/2 NPSM, for M9210(20) and M(VA)9208 Series Actuators (quantity 5) M9208-100 Remote Mounting Kit, including Mounting Bracket, M9208-150 Crankarm, Ball Joint, and mounting fasteners (quantity 1) M9208-150 Crankarm Adapter Kit (quantity 1) M9208-600 Large Shaft Coupler Kit (with Locking Clip) for Mounting M9208 Series Electric Spring Return Actuators on dampers with round shafts from 1/2 to 3/4 in. (12 to 19 mm) or square shafts from 3/8to9/16in.(10to14mm) (quantity 1) M9208-601 Replacement Standard Coupler Kit (with Locking Clip) for mounting M9208 Series Electric Spring Return Actuators on dampers with round shafts from 5/16 to 5/8 in. (8 to 16 mm) or square shafts from 1/4 to 1/2 in. (6 to 12 mm) (quantity 1) M9208-602 Replacement Locking Clips for M9208 Series Electric Spring Return Actuators (quantity 5) M9208-603 Adjustable Stop Kit for M9208 Series Electric Spring Return Actuators (quantity 1) M9220-604 Replacement Manual Override Cranks for M9208 Series Electric Spring Return Actuators with long crank radius: 2.83 in. (72 mm) (quantity 5) M9208-605 Replacement Manual Override Cranks for M9208 Series Electric Spring Return Actuators with short crank radius: 1.83 in. (46.5 mm) (quantity 5) 1. Furnished with the damper and may be ordered separately. M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin 7

Dimensions 3-29/32 (99) 2-1/4 (57.5) 1/8 (3.2) 2-9/16 (64.5) 1-1/8 (28.5) 3/4 (19) 1/4 (6.4) 4-3/4 (120.7) 4-29/32 (124.8) 6-5/16 (160.7) 4 Mounting Holes 4-7/32 (5.45) Diameter 1/4 (6.5) Slot Width 21/32 (16.7) 1-19/32 (40.7) 1-3/8 (34.5) FIG:M9208-Dims Figure 7: M9208-xxx-x Series Electric Spring Return Actuator Dimensions, in. (mm) Technical Specifications M9208-GGx-x Series Proportional Electric Spring Return Actuator (Part 1 of 3) Power Requirements Input Signal / Adjustments Control Input Impedance -GGx Models -GGx Models -GGx Models AC 24 V (AC 19.2 V to 28.8 V) at 50/60 Hz: Class 2 (North America) or Safety Extra-Low Voltage (SELV) (Europe), 7.9 VA Running, 5.5 VA Holding Position DC 24 V (DC 21.6 V to 28.8 V): Class 2 (North America) or SELV (Europe), 3.5 W Running, 1.9 W Holding Position Minimum Transformer Size: 8 VA per Actuator Factory Set at DC 0 to 10 V, CW Rotation with Signal Increase; Selectable DC 0 (2) to 10 V or 0 (4) to 20 ma with Field-Furnished 500 ohm 0.25 W Minimum Resistor; Switch Selectable Direct or Reverse Action with Signal Increase Voltage Input: 100,000 ohm Current Input: 500 ohm with Field Furnished 500 ohm Resistor Feedback Signal -GGx Models DC 0 (2) to 10 V for Desired Rotation Range up to 95 Corresponds to Rotation Limits, 0.5 ma at 10 V Maximum Auxiliary Switch Rating Spring Return -xxc Models Two Single-Pole, Double-Throw (SPDT), Double-Insulated Switches with Gold over Silver Contacts: AC 24 V, 50 VA Pilot Duty AC 120 V, 5.8 A Resistive, 1/4 hp, 275 VA Pilot Duty AC 240 V, 5.0 A Resistive, 1/4 hp, 275 VA Pilot Duty Direction Is Selectable with Mounting Position of Actuator: Actuator Face Labeled A Is Away from Damper or Valve: CCW Spring Return Actuator Face Labeled B Is Away from Damper or Valve: CW Spring Return 8 M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin

M9208-GGx-x Series Proportional Electric Spring Return Actuator (Part 2 of 3) Rated Torque 70 lb in. (8 N m) All Operating Temperatures 70 lb in. (8 N m) All Operating Temperatures Rotation Range Maximum Full Stroke: 95 Adjustable Stop: 35 to 95 Maximum Position Rotation Time for 90 Degrees of Travel Life Cycles Audible Noise Rating Electrical Connections (Holding) Models: GGx-3 Models: GGA-2 Auxiliary Switches (-xxc Models) Conduit Connections Mechanical Round Shafts Connections Square Shafts Enclosure Rating 150 Seconds Constant for 0 to 70 lb in (8 N m) Load, at all Operating Conditions 90 Seconds for 0 to 70 lb in (8 N m) Load in Calibration Mode or Override Mode 17 to 25 Seconds for 0 to 70 lb in. (8 N m) Load, at Room Temperature 22 Seconds Nominal at Full Rated Load 94 Seconds Maximum with 70 lb in. (8 N m) Load, at -40 F (-40 C) 60,000 Full Stroke Cycles with 70 lb in. (8 N m) Load 1,500,000 Repositions with 70 lb in. (8 N m) Load <35 dba at 70 lb in. (8 N m) Load, at a Distance of 39-13/32 in. (1 m) <20 dba at a Distance of 39-13/32 in. (1 m) <52 dba at 70 lb in. (8 N m) Load, at a Distance of 39-13/32 in. (1 m) 48 in. (1.2 m) UL 758 Type AWM Halogen Free Cable with 18 AWG (0.85 mm²) Conductors and 0.25 in. (6 mm) Ferrule Ends 120 in. (3.05 m) UL 444 Type CMP Plenum Rated Cable with 19 AWG (0.75 mm²) Conductors and 0.25 in. (6 mm) Ferrule Ends 48 in. (1.2 m) UL 758 Type AWM Halogen Free Cable with 18 AWG (0.85 mm²) Conductors and 0.25 in. (6 mm) Ferrule Ends Integral Connectors for 3/8 in. (10 mm) Flexible Metal Conduit Range of Sizes: 5/16 to 5/8 in. (8 to 16 mm) Range of Sizes: 1/4 to 1/2 in. (6 to 12 mm) NEMA 2 (IP54) for all Mounting Directions Ambient Conditions Dimensions Standard Operating Storage -40 to 140 F (-40 to 60 C); 90% RH Maximum, Noncondensing -40 to 185ºF (-40 to 85ºC); 95% RH Maximum, Noncondensing 6.33 x 3.90 x 2.26 in. (160.7 x 99 x 57.5 mm) M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin 9

M9208-GGx-x Series Proportional Electric Spring Return Actuator (Part 3 of 3) Compliance United States UL Listed, CCN XAPX, File E27734; to UL 60730-1A: 2003-08, Ed. 3.1, Automatic Electrical Controls for Household and Similar Use; and UL 60730-2-14: 2002-02, Ed. 1, Part 2, Particular Requirements for Electric Actuators. (Models: All) Shipping Weight Canada Europe Australia and New Zealand UL Listed, CCN XAPX7, File E27734; to UL 60730-1:02-CAN/CSA: July 2002, 3rd Ed., Automatic Electrical Controls for Household and Similar Use; and CSA C22.2 No. 24-93 Temperature Indicating and Regulating Equipment (Models: All). CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive and Low Voltage Directive. RCM Mark, Australia/NZ Emissions Compliant (Models: All) Models: -GGA: 3.43 lb (1.6 kg) Models: -GGC: 3.8 lb (1.7 kg) 10 M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin

M9208-AGx-x Series On/Off and Floating Point Control Electric Spring Return Actuator (Part 1 of 2) Power Requirements -AGx Models AC 24 V (AC 19.2 V to 28.8 V) at 50/60 Hz: Class 2 (North America) or Safety Extra-Low Voltage (SELV) (Europe), 7.9 VA Running, 5.5 VA Holding Position DC 24 V (DC 21.6 V to 28.8 V): Class 2 (North America) or SELV (Europe), 3.5 W Running, 1.9 W Holding Position Minimum Transformer Size: 8 VA per Actuator Input Signal -AGx Models AC 19.2 to 28.8 V at 50/60 Hz or DC 24 V 20%/-10% Class 2 (North America) or SELV (Europe) Minimum Pulse Width: 500 ms Control Input Impedance -AGx Models 3,000 ohm Control Inputs Auxiliary Switch Rating -xxc Models Two Single-Pole, Double-Throw (SPDT), Double-Insulated Switches with Gold over Silver Contacts: AC 24 V, 50 VA Pilot Duty AC 120 V, 5.8 A Resistive, 1/4 hp, 275 VA Pilot Duty AC 240 V, 5.0 A Resistive, 1/4 hp, 275 VA Pilot Duty Spring Return Direction Is Selectable with Mounting Position of Actuator: Actuator Face Labeled A Is Away from Damper or Valve: CCW Spring Return Actuator Face Labeled B Is Away from Damper or Valve: CW Spring Return Rated Torque 70 lb in. (8 N m) All Operating Temperatures 70 lb in. (8 N m) All Operating Temperatures Rotation Range Maximum Full Stroke: 95 Adjustable Stop: 35 to 95 Maximum Position Rotation Time for 90 Degrees of Travel Life Cycles Audible Noise Rating Electrical Connections (Holding) Models: AGx-3 Models: AGA-2 Auxiliary Switches (-xxc Models) Conduit Connections Mechanical Round Shafts Connections Square Shafts Enclosure Rating 150 Seconds Constant for 0 to 70 lb in. (8 N m) Load, at all Operating Conditions 17 to 25 Seconds for 0 to 70 lb in. (8 N m) Load, at Room Temperature 22 Seconds Nominal at Full Rated Load 94 Seconds Maximum with 70 lb in. (8 N m) Load, at -40 F (-40 C) 60,000 Full Stroke Cycles with 70 lb in. (8 N m) Load 1,500,000 Repositions with 70 lb in. (8 N m) Load <35 dba at 70 lb in. (8 N m) Load, at a Distance of 39-13/32 in. (1 m) <20 dba at a Distance of 39-13/32 in. (1 m) <52 dba at 70 lb in. (8 N m) Load, at a Distance of 39-13/32 in. (1 m) 48 in. (1.2 m) UL 758 Type AWM Halogen Free Cable with 18 AWG (0.85 mm²) Conductors and 0.25 in. (6 mm) Ferrule Ends 120 in. (3.05 m) UL 444 Type CMP Plenum Rated Cable with 19 AWG (0.75 mm²) Conductors and 0.25 in. (6 mm) Ferrule Ends 48 in. (1.2 m) UL 758 Type AWM Halogen Free Cable with 18 AWG (0.85 mm²) Conductors and 0.25 in. (6 mm) Ferrule Ends Integral Connectors for 3/8 in. (10 mm) Flexible Metal Conduit Range of Sizes: 5/16 to 5/8 in. (8 to 16 mm) Range of Sizes: 1/4 to 1/2 in. (6 to 12 mm) NEMA 2 (IP54) for all Mounting Directions M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin 11

M9208-AGx-x Series On/Off and Floating Point Control Electric Spring Return Actuator (Part 2 of 2) Ambient Standard Operating -40 to 140 F (-40 to 60 C); 90% RH Maximum, Noncondensing Conditions Storage -40 to 185ºF (-40 to 85ºC); 95% RH Maximum, Noncondensing Dimensions 6.33 x 3.90 x 2.26 in. (160.7 x 99 x 57.5 mm) Compliance United States UL Listed, CCN XAPX, File E27734; to UL 60730-1A: 2003-08, Ed. 3.1, Automatic Electrical Controls for Household and Similar Use; and UL 60730-2-14: 2002-02, Ed. 1, Part 2, Particular Requirements for Electric Actuators. (Models: All) Canada UL Listed, CCN XAPX7, File E27734; to UL 60730-1:02-CAN/CSA: July 2002, 3rd Ed., Automatic Electrical Controls for Household and Similar Use; and CSA C22.2 No. 24-93 Temperature Indicating and Regulating Equipment (Models: All). Europe CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive and Low Voltage Directive. Australia and RCM Mark, Australia/NZ Emissions Compliant (Models: All) New Zealand Shipping Weight Models: -AGA: 3.43 lb (1.6 kg) Models: -AGC: 3.8 lb (1.7 kg) M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin 12

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators (Part 1 of 2) Power Requirements Auxiliary Switch Rating Spring Return -BGx Models -BAx Models -BDx Models -xxc Models AC 24 V (AC 18 V to 30 V) at 50/60 Hz: Class 2 (North America) or Safety Extra-Low Voltage (SELV) (Europe), 6.1 VA Running, 1.2 VA Holding Position DC 24 V (DC 21.6 V to 28.8 V): Class 2 (North America) or SELV (Europe), 3.5 W Running, 0.5 W Holding Position Minimum Transformer Size: 7 VA per Actuator AC 120 V (AC 102 V to 132 V) at 60 Hz: 0.05 A Running, 0.03 A Holding Position AC 230 V (AC 198 V to 264 V) at 50/60 Hz: 0.04 A Running, 0.03 A Holding Position Two Single-Pole, Double-Throw (SPDT), Double-Insulated Switches with Gold over Silver Contacts: AC 24 V, 50 VA Pilot Duty AC 120 V, 5.8 A Resistive, 1/4 hp, 275 VA Pilot Duty AC 240 V, 5.0 A Resistive, 1/4 hp, 275 VA Pilot Duty Direction Is Selectable with Mounting Position of Actuator: Actuator Side A Is Away from Damper or Valve: CCW Spring Return Actuator Side B Is Away from Damper or Valve: CW Spring Return Rated Torque 70 lb in. (8 N m) All Operating Temperatures 70 lb in. (8 N m) at Standard Operating Temperatures 53 lb in. (6 N m) at Extended Operating Temperatures Rotation Range Maximum Full Stroke: 95 Adjustable Stop: 35 to 95, Maximum Position Rotation Time for 90 Degrees of Travel Life Cycles Audible Noise Rating Electrical Connections (Holding) Actuator (All Models) Auxiliary Switches (-xxc Models) Conduit Connections Mechanical Round Shafts Connections Square Shafts Enclosure Rating Ambient Standard Operating Conditions Extended Operating Storage Dimensions 55 to 71 Seconds for 0 to 70 lb in. (8 N m) Load, at All Operating Conditions 60 Seconds Nominal at Full Rated Load (0.25 rpm) 13 to 26 Seconds for 0 to 70 lb in. (8 N m) Load, at Room Temperature 21 Seconds Nominal at Full Rated Load 39 Seconds Maximum with 70 lb in. (8 N m) Load at -4 F (-20 C) 108 Seconds Maximum with 53 lb in. (6 N m) Load at -40 F (-40 C) 60,000 Full-Stroke Cycles with 70 lb in. (8 N m) Load <47 dba at 70 lb in. (8 N m) Load, at a Distance of 39-13/32 in. (1 m) <20 dba at a Distance of 39-13/32 in. (1 m) <52 dba at 70 lb in. (8 N m) Load, at a Distance of 39-13/32 in. (1 m) 48 in. (1.2 m) UL 758 Type AWM Halogen-Free Cable with 18 AWG (0.85 mm²) Conductors and 0.25 in. (6 mm) Ferrule Ends 48 in. (1.2 m) UL 758 Type AWM Halogen-Free Cable with 18 AWG (0.85 mm²) Conductors and 0.25 in. (6 mm) Ferrule Ends Integral Connectors for 3/8 in. (10 mm) Flexible Metal Conduit Range of Sizes: 5/16 to 5/8 in. (8 to 16 mm) Range of Sizes: 1/4 to 1/2 in. (6 to 12 mm) NEMA 2 (IP54) for All Mounting Orientations -4 to 140 F (-20 to 60 C); 90% RH Maximum, Noncondensing -40 to -4 F (-40 to -20 C); 90% RH Maximum, Noncondensing -40 to 185 F (-40 to 85 C); 95% RH Maximum, Noncondensing 6.33 x 3.90 x 2.26 in. (160.7 x 99 x 57.5 mm) M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin 13

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators (Part 2 of 2) Compliance United States UL Listed, CCN XAPX, File E27734; to UL 60730-1A: 2003-08, Ed. 3.1, Automatic Electrical Controls for Household and Similar Use; and UL 60730-2-14: 2002-02, Ed. 1, Part 2, Particular Requirements for Electric Actuators. (Models: All) Shipping Weight Canada Europe Australia and New Zealand UL Listed, CCN XAPX7, File E27734; to UL 60730-1:02-CAN/CSA: July 2002, 3rd Ed., Automatic Electrical Controls for Household and Similar Use; and CSA C22.2 No. 24-93 Temperature Indicating and Regulating Equipment (Models: All). CE Mark Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the EMC Directive and Low Voltage Directive. RCM Mark, Australia/NZ Emissions Compliant (Models: All) Models: -BGC:3.75lb(1.7kg) Models: -BAC and -BDC: 4.15 lb (1.9 kg) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact: JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA JOHNSON CONTROLS C/O CONTROLS PRODUCT MANAGEMENT NO. 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2016 Johnson Controls, Inc. 14 M9208-xxx-x Series Electric Spring Return Actuators Product Bulletin Published in U.S.A. www.johnsoncontrols.com