W1/B, O, W2/E, Y1, Y2, G. Gas or electric. Wireless, 915MHz, proprietary protocol. Up to 100 feet 24VAC, 2.4VA. Molded plastic

Similar documents
USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Operation Guide 3M-22

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Mode Switch. Fan Switch Menu button Program button

Drayton Digistat +2RF/+3RF

EK908FHL - Thermostat for floor heating

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Install Guide 3M-50. Caution. Caution

HEAT PUMP PROGRAMMABLE THERMOSTAT

Installation Guide. Programmable Thermostat TH6220D

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

HEAT HEAT COOL HEAT PUMP COOL

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.

Install Guide CT101. Caution. Caution

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

Installation Guide for Hive Active Heating

T-100-R Installation Guide

TC-9102 Series Surface Mount Temperature Controllers

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Operation 8022C. Customer Support: or Visit our webiste Made In China OFF FAN HEAT COOL AUTO ON

QUICK INSTALLATION GUIDE

Installation Instructions

INSTALLATION AND OPERATION MANUAL

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Installer Guide smart connect

INSTALLATION INSTRUCTIONS

Single Zone LCD Thermostat Operating Instructions

1. Overview. WPT Wireless Range Tester Kit User Manual Doc No Rev Components Prerequisites for Site Survey

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Commercial Refrigeration Temperature and Defrost Controls

1 For All Non-Programmable Digital Thermostat

INSTALLER S & OWNER S MANUAL

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

WIRELESS MULTI-ZONE DIGITAL WEATHER CENTER. Model No User s Manual

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

WPR400 Wireless Portable Reader

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Wireless Thermostats 230v and Battery Operated Instruction Manual

Thermostat with display

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Application Engineering

Powers Controls TH 192 S Single Temperature Room Thermostat

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

REMOTE CONTROL MANUAL

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY.

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

SC Installation, Operation & Application Guide

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Installation Instructions

AC-115 Compact Networked Single Door Controller. Installation and User Manual

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Duct Humidity Transmitter

GENERAL SUPPLEMENT 410. Radiantec CONTROLS FOR RADIANT HEATING CONTROLS PURPOSE OF RADIANTEC CONTROLS

RF 1. Contents: Connecting diagram. Detailed information:

Emergency Heat slide switch on the panel or an external switch. Do not use the panel switch or the external switch if Dip switch #4 is set to HP.

Inwall Room Temperature Unit

K9 Heat Alarm Owners Manual HA-1520

User Guide. Temperature and Humidity Datalogger. Model 42280

Walk-in Monitoring System 200

HMI display Installation Guide

IN-OUT Thermometer with Cable Free Sensor and Clock

Wireless Indoor/ Outdoor Thermometer

Communicating Wall Control Installation Manual TSTAT0101SC

WiFi Setup Guide for Windows7 or Vista

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

Home Security Alarm System

Simon XT/XTi CDMA Module V4 Installation Instructions

Digistat RF Troubleshooting Procedure

Installation Guide. Prestige IAQ with Equipment Interface Module. RedLINK to Equipment Interface Module. RedLINK to TrueZONE Wireless Adapter

Wireless Home Security Alarm System AM 500

G-100/200 Operation & Installation

ADEMCO 4500 Thermostat

Quick Guide. for Canon MHz, US FCC/IC MHz, CE

Installer guide. Release 2.2

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

Transcription:

Wireless COMF TTM Made in the USA Application Installation Manual Model WCT-32 The WCT-32 is a 7-day programmable, battery powered thermostat that communicates via an F wireless data link to a relay control module located near the HVAC equipment. SYSTEM FAN The WCT-32 can control single stage, multistage and heat pumps with up to 3 stages of heating and 2 stages of cooling. Features Manual or programmable selection with up to four schedules per day. Exclusive Memory Backup insures reliable performance in the event of a communications interruption. Wireless 915MHz proprietary protocol with up to 100 transmission range. Specifications Compatible Equipment Output Terminals Fan Operation LED Indicator Communications ange Control Module Power Control Module Housing Control Module Dimensions Thermostat Dimensions Easy access, front-loading battery compartment. 2 AA batteries included. Single stage, multi-stage and heat pumps (3 heat / 2 cool) W1/B, O, W2/E,,, as or electric Multi-color indicates heating, cooling and fan calls Wireless, 915MHz, proprietary protocol Up to 100 feet 24VAC, 2.4VA Molded plastic 5.09 x 2.65 x 1.10 inches (WHD) 5.00 x 4.50 x 1.00 inches (WHD)

HVAC Module 1 Installation The HVAC module should be installed close to the equipment being controlled. Do not install it within a metal enclosure that might interfere with wireless communications. Only standard 18 gauge thermostat wire is required to wire the module to the equipment. Two #6 sheet metal mounting screws are included or the module can be installed with double-backed adhesive tape. 2.65 W1/B O W2/E C.187 dia. 2 plcs 5.09 4.57 2 Wiring The HVAC module is powered by the 24VAC from HVAC system The diagrams below show wiring when configured for as / Electric and Heat Pump systems. 1.10 as / Electric (up to 2 heat / 2 cool) as / Electric HVAC System C W2/E O W1/B COM W2 W1 Heat Pump (up to 3 heat / 2 cool) Heat Pump System C W2/E O W1/B COM W2/E O B 2

Thermostat 3 Location The thermostat should be located in an area that represents the ambient space temperature and within 100 feet of the HVAC Control Module. Do not install the thermostat in an area where drafts are present, near the floor, behind doors or on an external wall. Avoid placing the thermsotat in areas where the air movement is limited, affected by direct sunlight or other areas not typical of the temperature in the space. 5 Installing the Sub-Base The thermostat should be installed approximately 5 feet above the floor. Level the sub-base for appearance and use the wall anchors and screws provided. 4 emoving the Sub-Base Hold the sub-base with one hand, press the case as shown below and pull the bottom of the thermostat from the sub-base. 6 Installing the Batteries Slide the battery cover off and install two AA batteries included with the thermostat. Install the batteries with the positive terminals to the right as shown. eplace the battery cover. Press here to release case from sub-base. The LCD will display the time of day, the setpoint temperature and the room temperature. 3

7 Thermostat Installer s The installer options can be accessed by pressing and holding the key for seven seconds. The LCD displays 01 for setting the Zone number. (See Installer s Chart) Press or hold the key to advance to the next option. The LCD will advance through to 16 and then return to 01. Press the key to save all options in nonvolatile flash ram. If only one wireless thermostat and HVAC Control Module are used in an application, the thermostat can be left with the factory default setting of Zone = 01 and Home = 01. If multiple wireless thermostats and HVAC Control Modules are used that are less than 500 feet away from one another, each thermostat must be set to a different Home number. For convenience, set the Installer s with the thermostat off the subbase and in easy access of its HVAC Control Module. 8 Setting the Zone Number Use the Up and Down keys to set the Zone number for the each thermostat. The Zone number can be set from 01 to 08. Zone Zone Numbers can be used to identify individual thermostats. Press the key to advance to the next option. Press the key if no more options are to be changed. Installer s Chart 9 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 Description Zone number ange 01 to 08 Default 01 Home number ange 01 to 32 Default 01 Program HVAC module with Zone and Home address - Default 01 Equipment type ange 00- /E 01- Heat Pump Default 00- /E Indoor Fan Operation ange 00- as 01- Electric Default 00- as Minimum Off Time ange 01 to 09 minutes Default 00 minutes Minimum un Time ange 01 to 09 minutes Default 00 minutes Maximum allowable heating setpoint ange 60 to 85F Default 85F Minimum allowable cooling setpoint ange 55 to 80F Default 65F Heat/Cool Setpoint Differential ange 02 to 06F Default 02F Stage 1 Temperature Differential ange 01 to 04F Default 01F Stage 2 Temperature Differential ange 01 to 10F Default 03F Stage 3 Temperature Differential ange 01 to 12F Default 05F Staging Time ange 0=OFF 1=ON Default 0 Staging Time When 14 = 1 (ON) ange 15-30 (1 Minute Increments) Default 15 Automatic Backup ange 00- Off 01- On Default 01- On Setting the Home number Press the key to select 02. The Home number is used to distinguish between thermostats and HVAC Control Modules that are less than 500 feet away from one another. This could be a home with two HVAC systems or a multi-family residence. 4

Use the Up and Down keys to set the Home number for the thermostat. The Home number can be set from 01 to 32. Skip this option if no other thermostats and modules are nearby. Home The LCD display for 03 is shown below. Press the key to send the new address to the HVAC module after pressing the module program key and the LED starts to blink red and green. When the module LED begins to flash yellow, it will now only respond to the thermostat with the same address. You will need to re-enter the Installer s menu to finish configuring the thermostat. Zone 10 Programming the HVAC Module After selecting the Zone and Home numbers for the thermostat, the same address must be programmed into the HVAC Module. Power up the module and press the program button. The module will accept a new address for thirty seconds. The LED on the module will alternately blink red and green while it is waiting for a new address after which the LED will display whatever state the thermostat is in. Press Program Button 11 Selecting Equipment Type The HVAC Control Module can be set for either gas/electric or heat pump operation. Press the key to select 04 and press the Up or Down key to select 00 = as/electric or 01 = Heat Pump operation. LED INDICATION Flashing reen - No calls Solid Yellow - First stage cooling Flashing Yellow - Second stage cooling Solid ed - First stage heating Flashing ed - Second stage heating Solid reen - Fan 12 Fan Operation Press the key to select 05. The fan can be set to 00 = as operation where the equipment activates the HVAC system fan during heating calls or to 01 = Electric operation where the module activates the fan during heating calls. In heat pumps and all cooling calls, the module activates the fan () terminal. 5

13 Minimum Off Time The minimum Off time prevents the compressor from restarting too quickly. Large HVAC systems should use a longer Off time. The minimum Off time and the minimum un time also influence the cycling rate. Press the key to select 06 and press the Up or Down key to set the Minimum Off Time. 14 Minimum un Time The Minimum un Time influences the cycling rate and helps to evaporate condensation in heat ex-changers. Press the key to select 07 and press the Up or Down key to set the Minimum un Time. 15 Heating Setpoint Limit The maximum heating setpoint the user can set is 60 to 85F. Press the key to select 08 and press the Up or Down key to set maximum allowable heating setpoint. 16 Cooling Setpoint Limit The minimum cooling setpoint the user can set is 55 to 80F. Press the key to select 09 and press the Up or Down key to set the minimum allowable cooling setpoint. 17 Heat / Cool Setpoint Differential The Heat/Cool temperature differential prevents the heating setpoint from being set above or too close to the cooling setpoint, resulting in inadvertent cycling between heating and cooling. 6

Press the key to select 11 and press the Up or Down key to set the setpoint differential. Press the key to select 12 and the Up or Down key to set the second stage temperature differential. If the first stage temperature differential is greater than third stage temperature differential, first stage differential will automatically be incremented. 18 First Stage Differential First stage temperature differential determines the sensitivity of the thermostat. A lower differential will cause the thermostat to cycle more often with smaller temperature swings. If the temperature differential between indoor temperature and setpoint temperature is greater than the first stage temperature differential, first stage heating or cooling will be activated. Press the key to select 11 and press the Up or Down key to set the first stage differential. 20 Third Stage Differential Third stage temperature differential determines when the equipment advances from second to third stage. Setting the differential temperatures the same for second stage and third stage turns second and third stage on at the same time. Press the key to select 13 and the Up or Down key to set the third stage temperature differential. The third stage temperature differential cannot be set below the second stage differential. 19 Second Stage Differential Second stage temperature differential determines when the equipment advances from first to second stage. If the temperature differential between indoor temperature and setpoint exceeds the second stage temperature differential, the equipment activates second stage heating or cooling. 21 Stage Timing The Staging Override Time will turn on the next stage even though the temperature differential has not been reached. Press the key to select 14 and the Up or Down key to set the stage timing. 7

comparing the temperature readings. Press and hold the MENU key until the calibration screen appears as shown. Use the Up and Down keys to adjust the temperature calibration offset. Press the key to save the setting and return to normal thermostat operation. 22 Automatic Backup The HVAC Control Module saves the previous 24- hour pattern of heating, cooling and fan calls in memory. Should the module lose communications with the thermostat because of a low battery or other reason, the module automatically repeats the call pattern of the previous 24 hours. Press the key to select 16 and the Up or Down key to set the Backup On (01) or Off (00). It is highly recommended that this option be left on. MENU Inside esetting Factory Defaults To reset the factory defaults, remove the batteries and re-install them while holding down the SYSTEM key. All prior changes will default to the factory settings. This will require resetting the time of day and programming schedules if necessary. efer to the Installer s Chart default settings to make any additional changes. This installation manual should not be left with unauthorized users as it contains installer setup functions which, if not correctly set, may cause damage to the HVAC equipment or seriously affect performance. This manual is to be used in conjunction with the supplied User Manual. 23 Calibrating the Temperature Sensor Offset Typically, it is not necessary to adjust the temperature calibration offset from the factory setting. If calibration is necessary, a high quality electronic digital thermometer must be used. Place the thermometer sensor probe next to the thermostat sensor and allow five minutes before Although great care has been taken in preparation of this manual, Jackson Systems takes no responsibility for errors or omissions contained herein. It is the responsibility of the installer to ensure that this thermostat and the equipment connected to it operate in a safe and efficient manner. Due to ongoing product improvements, Jackson Systems reserves the right to change the specifications of the WCT-32 thermostat or its components without notice. All rights reserved. Jackson Systems, LLC 2010 Intellectual rights apply. 5418 Elmwood Avenue, Indianapolis, IN 46203-6025 Toll Free: 888.652.9663 Fax: 317.227.1034 www.jacksonsystems.com 8 06-1055-030211