Zander Dryer Memory Control. for heat regenerated adsorption dryer. Applikationsbild

Similar documents
Find more information on this product on our homepage. NEW! Now with improved ZDMC2. Adsorption Dryer Concept WVM

Concept WVM Brief description. Effi cient compressed-air adsorption dryer with vacuum regeneration. NEW! Now with improved ZDMC2

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

1 Application Description Objective Goals... 3

Programming Logic controllers

PCS0100en Persy Control Services B.V. Netherlands

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Application/Connection Examples

Permissible ambient temperature Operation Storage, transport

Controlers. Controler

PRODUCT LIST Facility DDC Access WebXL DDC

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Sigma Control PC INSIDE. 97 psi 187 F R on load

MI4 - Operator Panel : Engineering

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

SMS GSM Alarm Messenger

RS - SPM. Serial parallel translator module

BUSINESS SYSTEMS MONITORING

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

PLC training panel (Twido version)

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Controllers. The integrated standard software guarantees highest quality standards! Simple and safe operation. Specific and clear indication

CANtrol EC Modular Control System Powerful and versatile

Temperature & Humidity SMS Alert Controller

NEW. EVEN MORE data acquisition and test stand automation

1 Technical Description Lokal-200PC

UniOP epad33 and epad33t

... Electronic Softstarter...

Product Information Sheet UH28CS-12kV Hi Pot Tester

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Smart relays Zelio Logic Step into an intuitive world!

Data sheet SLIO CPU 015 (015-CEFPR00)

40.3. Control Relays and Timers

Produktnr. Navn Salgspris ekskl. moms

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

1.44 kw Programmable DC Power Supplies XLN Series

NC-12 Modbus Application

USB-500 Series Stand-Alone, Low-Cost Data Loggers

T Zone Weekly Timer

HMI. Operating and monitoring.

Quick Connect. quick - simple - efficient.

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

User manual LCD 240-2xx

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

Repeaters and Mimics Data Sheet

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

A project to optimise quality and energy efficiency must include metering

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

Final Design Report 19 April Project Name: utouch

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Concierge. Outdoor panels

OZW30. Central Unit SYNERGYR

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Electronic Control Devices The European Product Catalogue 2007

M2M The measure of efficiency

External temperature sensors for FSC Ultrasonic Flow Meter (thermal flow measurement function)

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

SYSTEM 45. C R H Electronics Design

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

HyperAccess Access Control System

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

REGTRONIC OPERATING INSTRUCTIONS

DVI KVM Switches DP-MUX 7.4

Pop. Parker operator panels. Pop CANopen. Compax3 I21T11 CANopen. with integrated axis. standalone SMH/MH. CANopen. digital inputs & outputs

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Controller board and power supply for vivimat III systems

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Terminal and Dimension

Terminal and Dimension

V350-R34 V350J-R34. npn inputs pnp inputs

TYPE APPROVAL CERTIFICATE

1 Application Description System Topology Hardware and Software Requirements... 3

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Optimize your simple machines... Modicon M218 Selection Guide

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Concentrating on the essentials: the new Basic Panels SIMATIC HMI. Answers for industry.

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Inwall 4 Input / 4 Output Module

Fingerprint Based Biometric Attendance System

Transcription:

for heat regenerated adsorption dryer Applikationsbild

Why the new ZDMC control? High operational safety with permanent monitoring of all measurements, available by Ethernet, RS232 (Optional Profibus or Modbus), voltage free contacts and analog output signals Optimised operation By using the 4 week trend recording of all measured values it is possible to optimise the dryer and identify aged desiccant. That saves energy costs! That saves money! Easy operated! Personnel are able to operate the controls easily, also without a manual, via a menu and touch screen Excellent overview! on a colour LCD screen with illustrated flow diagram. Easy upgrade by SD card! That saves time and money!

From January 2009 all Zander heat regenerated air dryers will be supplied as standard with a ZDMC programmable logic controller with colour LCD touch screen and a 4-week trend record of all data. Excellent operational overview on a colour LCD screen Permanent clear indication of all data at a glance : - Vessel pressures - Heating temperature - Regeneration temperature - Pressure Dewpoint - 3x Spare fields ( 2x PT100 and 1x 4-20 ma) Easy operation via touch screen Clearly function illustration from coloured flow diagram.

Simple to operate using menu navigation Multiple Language selection of language by touch of the globe symbol A big number of monitoring functions all measured data are permanently used for safety control and are recorded in a operating register. Large data register all measured values over the last 4 weeks are permanently recorded. Operating and application parameters can be analyzed and optimized from this data. These records supply important information about the possible cause of any malfunction.

Very easy adjustment of dewpoint switching Accessed via main menu or by touching the dewpoint box in the operating screen. Set by touching the key pad. One touch change of cycle (touch the green button) Recording of all operating and fault signals All procedures and malfunctions are stored in registers.

for für adsorption Adsorptionstrockner dryer High security and monitoring 2 volt free contacts operating signal & common alarm 2 selectable analogue output signals (4-20mA) 2 parameters can be selected for retransmission. Ethernet connection allows operating parameters transmission to a control room or PC, or a data transfer to Zander. ( Connection and communication software is not supplied ) Further interfaces - RS 232 (here is a Modbus connection (RS485) possible, if special version was ordered - Profibus connection optional ( additional circuit board required ) Programming language STEP7 (= Siemens S7) Simple editing and examination by SIEMENS- SIMATIC-S7-Manager. Software-Updates readily available Software and operating updates by SD card. Trend recording SD card and storage on SD card. 1GB With the SD card facility, data can be downloaded to a PC stored, and submit to Zander.

Technical data : Power supply 24 VDC Protection class IP65 Operating temperature 0 till +50 C Storage temperature -20 till +70 C LCD Touch screen (320 x 240 Pixel) Size (W x H x D): 177 x 134 x 60 mm 2 MB internal memory and 1 GB SD card for storage of last 4 weeks recordings. back up battery life time 10 years Ethernet connector RJ45 und Traffic-LED s for data transfer and remote control (RFC1006, send, receive, fetch, write) Profibus communication module optional (DP-Master or Slave ) Input signals : 16 digital inputs 24V voltage bounded, time delay (0->1, 1->0) 0,24ms Input voltage for signal 0 (type) <5V, Input voltage for signal 1 (type) >15V 4 analog inputs 4-20mA voltage bounded, resolution 10 Bit, 3 wire measurement 24V 4 analog inputs PT100 voltage bounded, resolution 10 Bit, 2 wire measurement, common ground Temperature range -5...+310 C Output signals : 12 digital transistor outputs 24V (max. 0,5 A) voltage bounded, max. 0,5A/output, external power supply 24V 8 digital Relay outputs 230V (max. 4A) 6x common connected L by common fuse (12A) (LIN, L1, L2, L3). 2x Voltage free contacts operating and common alarm 2 analog outputs 4...20mA voltage bounded, resolution 10 Bit

2008 Parker Hannifin Corporation Parker Hannifin Corporation ZANDER Aufbereitungstechnik GmbH Im Teelbruch 118 45219 Essen Telefon +49 (0) 20 54 934 0 Telefax +49 (0) 20 54 934 164 www.parker.com