205 North 400 West Salt Lake City, Utah (800) (800) TTY Facility Name

Similar documents
Common ADA Errors and Omissions in New Construction and Alterations

ADA. Checklist for Readily Achievable Barrier Removal. The Americans with Disabilities Act. Checklist for Existing Facilities version 2.1.

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Common ADA Errors and Omissions in New Construction and Alterations

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

ADA Checklist for Polling Places

American Academy of Physical Medicine and Rehabilitation Site Survey Report

Compliance Guide. For Title III of the Americans with Disabilities Act

U.S. DEPARTMENT OF HOUSING & URBAN DEVELOPMENT OFFICE OF FAIR HOUSING & EQUAL OPPORTUNITY UFAS ACCESSIBILITY CHECKLIST

ADA ACCESSIBILITY CHECKLIST FOR EXISTING FACILITIES

The emergency provisions affect the following Building Code sections:

AUSTRALIAN HUMAN RIGHTS COMMISSION NOTICE OF DECISION ON APPLICATION FOR TEMPORARY EXEMPTIONS: AUSTRALASIAN RAILWAY ASSOCIATION

Section 7: Elevators and Lifts. Main Entry Floor Outside the Elevator

ADA Design Guide Washrooms & Showers

604 Water Closets and Toilet Compartments

Expanding Your Market

COMMERCIAL ACCESSIBILITY PLAN REVIEW CHECKLIST

Walking and Working Surface Checklist:

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Welcome to the AccessibilityOnline Webinar Series. A collaborative program between the National Network of ADA Centers and the. U.S.

Accessibility Guide for Small Businesses

ADA Guide for Small Businesses

City of Los Angeles Department of Building and Safety Disabled Access Section COMMERCIAL ACCESSIBILITY PLAN REVIEW LIST JOB ADDRESS CITY ZIP

Bath Planning Guidelines With Access Standards

ACCESS AUDIT OF WESTPORT HOUSE

DUKE UNIVERSITY/DUKE UNIVERSITY HEALTH SYSTEM GUIDELINES FOR INSTALLING NEW PUBLIC TELEPHONES

Technical Bulletin: Understanding the ADA and Implications for Office Design

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

City of Auburn Americans with Disabilities Act (ADA) Transition Plan for Curb Ramps, Sidewalks, and Pedestrian Signals ADA TRANSITION PLAN

PEOPLE FIRST. How to Plan Events Everyone Can Attend. Braille Accessible Print Assistive Listening Systems

ADA POST INSPECTION CHECKLIST. Job No. Route County Location

REQUIREMENT 3. Usable Doors

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

ELECTRONIC HEALTH RECORDS AND WRITING SURFACES

COMMONLY USED RESIDENTIAL BUILDING CODES

Significant Changes to the 2013 California Building Code Chapter 11B accessibility standards

ADA Scoping: New Construction

Accessible Toilets. A unisex facility should have its own entrance. It should not be entered from a single sex facility.

accessibility standard

PUBLIC RESTROOMS, DESIGN INTENT

Universal Design Recommendations for Accessible University Settings. Mauricio A. Lizama, Ph.D., ATP


Lori Greene, AHC/CDC, CCPR, FDAI

City of Riverside Building & Safety Division Phone: (951)

Number of Sides Required to Have a Handrail

Accessibility Design Advice

Typical storey plan with two toilet clusters SANITARY PROVISION SANITARY PROVISION. Individual washroom. Standalone, unisex individual washroom

Kitchen Planning Guidelines With Access Standards

Base Cabinet with Self-storing Folding Doors and Floor

CHECKLIST C ACCESSIBLE TOILETS CHECKLIST

REQUIREMENT 5. Light Switches, Electrical Outlets, Thermostats, and Other Environmental Controls in Accessible Locations

ECONOMIC COMMISSION OF EUROPE (ECE) BRANDING

Policy Name: Accessible Customer Service Plan. Form # Position Responsible: VP Accreditation & Professional Development

Evanston Main Street Station TOD Plan and Study. Appendix A.1: Station Area Existing Conditions

Customer Access 1 Checklist for Banks, Financial and Legal Services

California Building Code Effective January 2014 HOUSING ACCESSIBILITY ACCESSIBLE WATER CLOSETS Title 24, Part A

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

ACCESSIBILITY STANDARD

Chapter Seven: REQUIREMENT 7. Usable Kitchens and Bathrooms PART A: Usable Kitchens PART B: Usable Bathrooms

Building Regulations (Northern Ireland) Department of Finance and Personnel protection from impact.

Accessibility and Universal Design. Presented by Jack D. Humburg Boley Centers, Inc.

Expanding Your Market. Accessible Information Exchange: Meeting on a Level Playing Field. Introduction. Accessible Meeting Location

OPTIONAL INFORMATION GUARDING FLOORS, STAIRS, AND OTHER OPENINGS SELF INSPECTION CHECKLIST

MEANS OF EGRESS CHAPTER 10

AUTOMATIC SWINGING DOOR

Approved Document M: Part M Access to and use of buildings Volume 1 dwellings. Consultation draft. August 2014

New York City Department of Buildings

Serving All: A Guide to Being Accessible for Your Customers and Community

Residential Deck Safety, Construction, and Repair

Residential Decks. Planning and Development Services Department

New York City Department of Buildings

Mobile Home Pre-Inspection Checklist

ELIGIBILITY APPLICATION

DRAFT PUBLIC CONSULTATION July Building Regulations Technical Guidance Document. Access and Use

`Fall Protection Guidelines in Construction

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

CHAPTER 10 MEANS OF EGRESS. User Note: See Preface page iv ("marginal markings" for Chapter 10 reorganization information.)

ACCESSIBLE SCHOOL FACILITIES A RESOURCE FOR PLANNING

Simplified Steel Stair Design for Commercial and Institutional Buildings

Accessible Public and Common Use Areas

SCOPE This guideline applies to all construction projects on Emory University properties, including renovation projects.

Education for All: The Cost of Accessibility

Access to libraries for persons with disabilities - CHECKLIST

Drew University Ladder Safety Program Policy and Inspection Procedure Draft 0412

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

Designing Pedestrian Facilities for Accessibility. ADA Compliance Training. Local Programs Engineer FHWA NJ Division

2010 ADA Standards for Accessible Design. Department of Justice

STANDARDS AUSTRALIA/STANDARDS NEW ZEALAND. Committee CE-001 Parking Facilities DRAFT. Australian/New Zealand Standard

Classroom Door Security & Locking Hardware

Page 1 of 6 COMPLIANCE CHECKLIST. > Long Term Care Facility - Nursing Unit

MEANS OF EGRESS CHAPTER 10

MEANS OF EGRESS CHAPTER 10

VERTICAL SPEED CONTROL DEVICES

Disabled Access Guide

Current as of 11/10/08 1 of 1

EXAM GUIDE. Schematic Design. Overview 2. Interior Layout Vignette 3 Sample Passing Solution 5 Sample Failing Solution 6

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

St. Michael s Hospital Accessibility Plan

Issue ID Description No. of Credits Available. Mandatory Elements Storage of Non-recyclable Waste and Recyclable Household Waste

Transcription:

ADA Checklist Facilities Fixed Facilities, Terminals and Stations 205 North 400 West Salt Lake City, Utah 84103 (800) 662 9080 (800) 550 4182 TTY www.disabilitylawcenter.org Access Facility Name Circulation Path Vertical Access (ADAAG 10.3.1) Yes No Are all elements, such as ramps, elevators or other circulation devices, placed to minimize the distance a wheelchair user must travel? Fare Areas (ADAAG 10.3.1) Yes No Are fare vending, other ticketing areas and fare collection areas placed to minimize the distance a wheelchair user must travel? Accessible Entrance and Route (ADAAG 10.3.1) Yes No Does the circulation path, including an accessible entrance and an accessible route, coincide with the circulation path for the general public? Directional Signage Where Circulation Path is Different (ADAAG 10.3.1, Yes No 4.30.7) Where the circulation path differs, does the directional signage comply with signage requirements? Mounted on wall adjacent to latch side of door, or as close as possible. Brailled text of the same information. If pictogram is used, it must be accompanied by raised characters and Braille. Signs mounted with centerline 60 inches from floor. Do the signs display the international symbol of accessibility? Entrances Accessible Route (ADAAG 10.3.1, 4.14) Is at least one entrance connected by an accessible route to public transportation stops, accessible parking, passenger loading zones and public streets or sidewalks and to all accessible spaces or elements within the facility? The accessible route should: Not require the use of stairs; Be stable, firm and slip-resistant; and Be at least 36 inches wide. Page 1 of 9

Public Entrances (ADAAG 10.3.1, 4.14) Yes No Do all accessible entrances coincide with those used by the general public, to the maximum extent practicable? Entrance Signs (ADAAG 10.3.1) Yes No Where signs are provided at station entrances, does the sign comply with signage requirements? Mounted on wall adjacent to latch side of door, or as close as possible. Brailled text of the same information. If pictogram is used, it must be accompanied by raised characters and Braille. Signs mounted with centerline 60 inches from floor. Are the signs placed in uniform locations at the entrances to the maximum extent practicable? Where the station has no defined entrance, but signage is provided, the accessible signage should be placed in a central location. Station/Platform Signs (ADAAG 10.3.1) Yes No Do stations have identification signs complying with signage requirements? Mounted on wall adjacent to latch side of door, or as close as possible. Brailled text of the same information. If pictogram is used, it must be accompanied by raised characters and Braille. Signs mounted with centerline 60 inches from floor. Are the identification signs placed at frequent intervals and clearly visible from inside the vehicle on both sides (when not obstructed by another train)? Sign Height (ADAAG 10.3.1) Yes No When station identification signs are placed close to vehicle windows, is the top of the highest letter or symbol below the top of the vehicle window and the bottom of the lowest letter or symbol above the horizontal mid-line of the vehicle window? Route Signs (ADAAG 10.3.1) Yes No Do route signs comply with signage requirements? Mounted on wall adjacent to latch side of door, or as close as possible. Brailled text of the same information. If pictogram is used, it must be accompanied by raised characters and Braille. Signs mounted with centerline 60 inches from floor. Page 2 of 9

Are all signs that list stations, routes or destinations served by the station placed in uniform locations within the transit system, to the maximum extent practicable? Automatic Fare Vending Machines (ADAAG 10.3.1, 4.27.2, 4.27.3, 4.27.4) Yes No Are automatic fare vending machines located at each accessible entrance and on an accessible route? If self-service fare collection devices are provided for the public, is there at least one accessible device for entering and exiting at each accessible point of entry or exit? Does each accessible fare collection device have a minimum clear width of 32 inches to allow passage of a wheelchair? Clear width: Is clear floor space (at least 30 inches by 48 inches) provided at coin or card slots and controls that allow either a forward or parallel approach by a person using a wheelchair? Clear floor space: If the clear floor space allows only a forward approach, then is the highest operable part no more than 48 inches from the floor? If the clear floor space allows only a parallel approach, then is the highest operable part no more than 54 inches from the floor? Are the controls operable with one hand and without tight grasping, pinching or twisting of the wrist? Fare Gates (ADAAG 10.3.1) Yes No Do gates which must be pushed open by wheelchair or mobility aid users have a smooth continuous surface extending from 2 inches above the floor to 27 inches above the floor? Surface: Accessible Fare Collection Location (ADAAG 10.3.1) Yes No Where the circulation path does not coincide with that used by the general public, is the accessible fare collection system located at or adjacent to the accessible point of entry or exit? Detectable Warnings (ADAAG 10.3.1, 4.29.2) Yes No Do platform edges bordering a drop-off not protected by platform screens or guard rails have a detectable warning? Are the detectable warnings 24 inches wide running the full length of the platform drop-off? Page 3 of 9

Does the detectable warning consist of raised truncated domes with a nominal diameter of 0.9 inches, a nominal height of 0.2 inches and a nominal center-tocenter spacing of 2.35 inches? Diameter: Spacing: Does the detectable warning contrast visually with adjoining surfaces (light-ondark or dark-on-light)? Is the material used to provide contrast an integral part of the walking surface? If the platform is in an interior location, does the detectable warning differ from the adjoining walking surface in resiliency or sound-on-cane contact? Platform Height Vertical Gap (ADAAG 10.3.1) Yes No Is the rail-to-platform height coordinated with the floor height of new vehicles so that the vertical difference (measured when the vehicle is at rest) is within plus of minus 5/8 inch under normal passenger load conditions? Existing vehicles operating in new stations may have a vertical difference with respect to the new platform within plus or minus 1 ½ inches. Vertical difference: Rail Systems Horizontal Gap (ADAAG 10.3.1) Yes No For rapid rail, light rail, commuter rail, high speed rail and intercity rail systems in new stations, is the horizontal gap (measured when the new vehicle is at rest) no greater than 3 inches? Horizontal gap: People Movers Horizontal Gap (ADAAG 10.3.1) Yes No For slow-moving automated guideway people mover transit systems, is the horizontal gap in new stations no greater than 1 inch? Horizontal gap: Boarding and Alighting (ADAAG 10.3.1) Yes No Is the station designed so that people with disabilities are able to board or alight from a vehicle at the same location as used by the general public? Illumination (ADAAG 10.3.1) Yes No Are illumination levels in the areas where signage is located uniform? Does the method of illumination minimize glare on signs? Is the lighting along circulation routes of the type and configuration to provide uniform illumination? Text Telephones (ADAAG 10.3.1, 4.31.9) Yes No Where inside public pay telephones are provided, is there a public text telephone? Page 4 of 9

If there are four or more public pay telephones located in any of the following locations, is at least one public text telephone provided in the location? Locations: main terminal outside the security areas; concourse within the security areas; or baggage claim area in a terminal. Track Crossings (ADAAG 10.3.1, 4.29.5) Yes No Where it is necessary to cross tracks to reach boarding platforms, is the surface of the route level and flush with the rail top at the outer edge and between the rails except for a maximum 2 ½-inch gap on the inner edge of each rail to permit passage of wheel flanges? OR, where gap reduction is not practicable, is there an above-grade or below-grade accessible route? Gap: Where the walkway crosses the vehicular way, is the boundary between the areas defined by a continuous detectable warning which is 36 inches wide? Public Address Systems (ADAAG 10.3.1) Yes No If there are terminal information systems that broadcast information to the general public through a public address system, is there a way to provide the same or equivalent information to people with hearing impairments, such as visual paging systems? Clocks (ADAAG 10.3.1) Yes No If clocks are provided for public use, are the clock faces uncluttered so that the elements are clearly visible? Do clock hands and numbers contrast with the background either light-on-dark or dark-on-light? Where mounted overhead, are the clock numbers 3 inches or greater in height? Are clocks placed in uniform locations throughout the facility? Escalators (ADAAG 10.3.1) Yes No Where provide in below grade stations, do escalators have a clear width of at least 32 inches? Clear width: At the top and bottom of each escalator run, are at least two contiguous treads level beyond the comb plate before the risers begin to form? Are all escalator treads marked by a strip of clearly contrasting color 2 inches wide, parallel to and on the nose of each step? (The edge of the thread must be apparent from both ascending and descending directions). Is the contrasting strip of a material that is at least as slip-resistant as the remainder of the thread? Page 5 of 9

Ticketing and Baggage Claim Areas (ADAAG 10.3.1) Yes No Are ticketing areas designed so that people with disabilities can get tickets and check baggage? Service Counters (ADAAG 7.2) Yes No At the ticketing area, is there a portion of the main counter that is no more than 36 inches high? Baggage Check-in and Retrieval (ADAAG 10.3.1) Yes No Are baggage check-in and retrieval systems on a route of travel that does not require the use of stairs? Is the route of travel stable, firm and slip-resistant? Is the route of travel at least 36 inches wide? Is there space immediately adjacent to the baggage check-in and retrieval system that is at least 30 inches wide and 48 inches long to provide a parallel or forward approach? Length: Gates (ADAAG 10.3.1) Yes No If unattended security barriers are provided, does one entrance door have at least 32 inches clear opening (for a double door, at least one 32-inch leaf)? Clear opening: Are there at least 18 inches of clear wall space on the pull side of the door, next to the handle? A person using a wheelchair or crutches needs this space to get close enough to open the door. Clear space: Is the door handle no higher than 48 inches and operable with a closed fist? The closed fist test for handles and controls: Try opening the door or operating the control using only one hand, held in a fist. Can doors be opened without too much force (exterior doors excluded; maximum is 5 lbf for interior doors)? You can use an inexpensive force meter or a fish scale to measure the force required to open a door. Attach the hook end to the doorknob or handle. Pull on the ring end until the door opens, and read off the amount of force required. If you do not have a force meter or a fish scale, you will need to judge subjectively whether the door is easy enough to open. Force: If the door is automatic, does it take at least 3 seconds to close? Seconds: Page 6 of 9

Access to Rest Rooms Getting to the Rest Rooms (ADAAG 4.1) Yes No If rest rooms are available to the public, is at least one rest room (either one for each sex or unisex) fully accessible? Are there signs at inaccessible rest rooms that give directions to accessible ones? Doorways and Passages (ADAAG 4.2, 4.13, 4.3) Yes No Is there tactile signage identifying rest rooms? Mount signs on the wall, on the latch side of the door, complying with the requirements for permanent signage. Are pictograms or symbols used to identify rest rooms, and, if used, are raised characters and Braille included below them? Is the doorway at least 32 inches clear? Clear width: Are doors equipped with accessible handles (operable with a closed fist), 48 inches high or less? Can doors be opened easily (5 lbf maximum force)? Force: Does the entry configuration provide adequate maneuvering space for a person using a wheelchair? A person in a wheelchair needs 36 inches of clear width for forward movement, and a 5-foot diameter or T-shaped clear space to make turns. A minimum distance of 48 inches clear of the door swing is needed between the two doors of an entry vestibule. Clear width: Is there a 36-inch-wide path to all fixtures? Stalls (ADAAG 4.17) Yes No Is the stall door operable with a closed fist, inside and out? Is there a wheelchair-accessible stall that has an area of at least 5 feet by 5 feet, clear of the door swing, OR is there a stall that is less accessible but that provides greater access than a typical stall (either 36 by 69 inches or 48 by 69 inches)? Length: In the accessible stall, are there grab bars behind and on the side wall nearest to the toilet? Is the toilet seat 17 to 19 inches high? Lavatories (ADAAG 4.19, 4.24) Yes No Does one lavatory have a 30-inch-wide by 48-inch-deep clear space in front? A maximum of 19 inches of the required depth may be under the lavatory. Page 7 of 9

Clear space: Is the lavatory rim no higher than 34 inches? Are there at least 29 inches from the floor to the bottom of the lavatory apron (excluding pipes)? Can the faucet be operated with one closed fist? Are soap and other dispensers and hand dryers within reach ranges and usable with one closed fist? Is the mirror mounted with the bottom edge of the reflecting surface 40 inches high or lower? Page 8 of 9

Additional Access Drinking Fountains (ADAAG 4.15) Yes No Is there at least one fountain with clear floor space of at least 30 by 48 inches in front? Clear space: Is there one fountain with its spout no higher than 36 inches from the ground and another with a standard height spout (or a single hi-lo fountain)? Are controls mounted on the front or on the side near the front edge and operable with one closed fist? Is each fountain cane-detectable (located within 27 inches of the floor or protruding in the circulation space less than 4 inches from the wall)? Protrusion: Telephones (ADAAG 4.31) Yes No If pay or public use phones are provided, is there clear floor space of at least 30 by 48 inches in front of at least one? Clear space: Is the highest operable part of the phone no higher than 48 inches (up to 54 inches if a side approach is possible)? Does the phone protrude no more than 4 inches into the route of travel? Protrusion: Does the phone have push-button controls? Is the phone hearing-aid compatible? Is the phone adapted with volume control? Is the phone with volume control identified with appropriate signage? If there are four or more public phones in the building, is one of the phones equipped with a text telephone (TT or TDD)? Is the location of the text telephone identified by accessible signage bearing the international TDD symbol? Page 9 of 9