Precast Wall Connection Wire Rope Boxes

Similar documents
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

Formwork Direct International Ltd Phone No +44 (0151) Fax no +44 (0151)

INSTRUCTIONS FOR USE

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

Connection Solutions

Armanet BEKAERT. Armanet THE CONSTRUCTIVE IDEA. Render & plaster @@@

Detailing of Reinforcment in Concrete Structures

Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

FORM DESIGN. easy to work with, and generally available.

TARIFF CODE and updates standard

Technical handbook Panel Anchoring System

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Hanson Building Products. precast basement solutions

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

39HQ Airovision Air Handling Units

GK Packing System Welding Instructions

ANCHOR BOLTS FOR NUCLEAR POWER PLANT APPLICATIONS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Page 1 of Sven Alexander Last revised SB-Produksjon STATICAL CALCULATIONS FOR BCC 250

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

INSULATION SYSTEMS FOR CODUCTORS

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

EUROPEAN ORGANISATION FOR TECHNICAL APPROVALS

The following sketches show the plans of the two cases of one-way slabs. The spanning direction in each case is shown by the double headed arrow.

19 DYNAmax Free Standing Server C A B I N E T s

Hamilton Form Company, Ltd Custom Designs, Flexible Solutions

Introduction. Eurocodes. Specification. Cost

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

ADVANCED SYSTEMS FOR RATIONAL SLAB REINFORCEMENT

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

Design Manual to BS8110

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

Wisconsin Building Products Evaluation

Hilti, Inc South 122 nd East Avenue Tulsa, OK

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

MultiPost-AP anchorage device

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Design MEMO 60 Reinforcement design for TSS 102

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

Design MEMO 54a Reinforcement design for RVK 41

19 DYNAmax Free Standing Server C A B I N E T s

DE Frame with C Series Sidelight

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

FUTURE SLAB. PENETRATIONS and. DEMOLITION of POST-TENSIONED FLOORS

HPM Rebar Anchor Bolt. For bolted connections. Technical Manual. European Technical Approval ETA-02/0006. Version: Peikko Group 01/2015

HYLINER AKS HDPE LINING

HVU with HAS/HAS-E rod adhesive anchor

Technical Application Document. Hilti HIT-RE 500-SD

EVALUATION OF SEISMIC RESPONSE - FACULTY OF LAND RECLAMATION AND ENVIRONMENTAL ENGINEERING -BUCHAREST

ENGINEERING SCIENCE H1 OUTCOME 1 - TUTORIAL 3 BENDING MOMENTS EDEXCEL HNC/D ENGINEERING SCIENCE LEVEL 4 H1 FORMERLY UNIT 21718P

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

METHOD OF STATEMENT FOR STATIC LOADING TEST

WI LEY Blackwell. Multi-storey Precast Concrete Framed Structures. Colin K. Jolly MSc, PhD, CEng, MICE, FIStructE

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Design and Construction of Cantilevered Reinforced Concrete Structures

HSL-3 Heavy duty anchor carbon steel. Anchor Fastening Technology Manual HSL-3. Heavy duty anchor. Version /

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

PPM High-Strength Anchor Bolt

Guidelines for Earthquake Bracing of Residential Water Heaters

Integrated Manhole Ladder System

valid as of 1 April 2014 Fradiflex metal water stop

BUILD A TABLETOP LOOM

MECHANICS OF SOLIDS - BEAMS TUTORIAL 2 SHEAR FORCE AND BENDING MOMENTS IN BEAMS

ENGLISH FORK GUIDE 2013

Composite Construction with KÖCO- Stud Welding Technology IMPRESSIVE TECHNOLOGY 6/

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Chapter 3 Pre-Installation, Foundations and Piers

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

Welded Fabric. The CARES Guide to Reinforcing Steels Part 5. Installation of welded fabric on a major contract. 1.0 Introduction

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

SikaProof A Technology

Hilti HIT-HY 150 MAX with rebar

FORMWORK INTRODUCTION

Technical Notes 3B - Brick Masonry Section Properties May 1993

Europeiskt Tekniskt Godkännande European Technical Approval

SINTEF Building and Infrastructure. Contents

Fire Barrier Duct Wrap 15A

Mechanical arms, belts and sheets

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

Window Installation Instructions

Owner's Manual & Assembly Instructions

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Basics of Reinforced Concrete Design

SECTION PRECAST CONCRETE STRUCTURES

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

lindab duct suspension & support system Duct suspensions & Support systems

HUS-HR Stainless steel Concrete Screw A CE conformity. Corrosion resistance. European Technical Approval

POST AND FRAME STRUCTURES (Pole Barns)

Strengthening of Large Storage Tank Foundation Walls in an Aggressive Environment by External Post-tensioning. May 7th 2013: Dominique Deschamps

Transcription:

Precast Wall Connection Wire Rope Boxes 12-1 www.cfsfixings.com

Contents Wire Boxes for Precast Panels 12-3 Selection 12-4 Capacities 12-5 Installation 12-7 Reinforcement of Concrete Elements 12-8 Supervision of Installation 12-9 R-Steel Loops 12-10 Dimensions 12-11 Installation 12-12 PRECAST WALL CONNECTION WIRE ROPE BOXES 10 www.cfsfixings.com 12-2

Wire Boxes for Precast Panels Wire Rope Boxes are designed to be used as a structural connection for pre-cast units with recesses, or between precast units and in-situ concrete components. The casing of the box eliminates the need for additional formwork. The rope boxes are very easy to use on site, with proven no-tool tear-off tape that releases the flexible loops. The loops are stitched into the adjoining element with rods and insitu concrete. We can provide boxes either containing a single loop or a double loop, depending on the load capacities that are required. 12-3 www.cfsfixings.com

Selection Our range includes Standard wire boxes, a Maxi wire box and Double wire rope boxes. The four types of Standard wire boxes have the same load capacity, selection should be made based on the thickness of the joint. For greater loads, use the Maxi box or Doube wire rope boxes. 4 Dimensions 2 DIMENSIONS AND MATERIALS 2.1 Dimensions and tolerances Standard and Maxi Wire Loop Boxes Table 1. Dimensions and tolerances of the RWL wire rope loop SL L L1 h b t Ø D Wire rope loop [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] Box Type Part No SL L L1 h b ±10 ±20 t ±10 ±2 ø(mm) ±2 ±2 D 1) (mm) ± 10 (mm) ± 20 (mm) ± 10 (mm) RWL-THIN ± RWL-WIDE 2 (mm) 80 ± 2100 306 (mm) 220 331 ± 225 2 180 220 Note 50 1 80 20 25 (mm) 6 6 60 60 Standard CFS-RVL-60 60 336 270 160 50 1) according to SFS-EN 12385. 20 6 55 CFS-RVL-80 80 250 60 CFS-RVL-100 100 230 Thickness of the steel plate of the box is 0,7mm. 65 CFS-RVL-120 120 210 70 Maxi CFS-RVL-140 140 528 370 200 50 20 8 100 Double CFS-RWL- 80 306 220 180 50 20 6 60 THIN CFS-RWL- WIDE 100 331 225 220 80 25 6 60 Thickness of steel plate of the box is 0,7mm. Note 1 according to SFS-EN 12385 Figure 1. Dimensions of the RWL wire rope loop Double Wire Loop Boxes R-Group Finland Oy Olavinkatu 1 57130 Savonlinna, Finland VAT: FI20250445 Tel. +358 20 722 9420 www.repo.fi www.rsteel.fi PRECAST WALL CONNECTION WIRE ROPE BOXES Materials Part Material Standard Steel box 1.0330 SFS-EN 10130 Wire rope high strength steel wire rope SE-Zn SFS-EN 12385 Compression sleeve 1.0046 SFS-EN 10025 The steel box and the wire rope are zinc coated. Zinced products are passivated with min. 1 month of storage. www.cfsfixings.com 12-4

Capacities The Standard boxes (RVL-60, -80, -100 and -120) all have equal capacities. For greater loads, use the Maxi box (RVL- 140) or the Double boxes (RWL-THIN and WIDE). Design Principles The capacities presented in the tables below are calculated for static loads. Our wire rope loops are not designed to be used for dynamic loading or for lifting. For the capacities to be achieved, there should be no cracks or deformations in the joints. The capacities of the wire rope loops are calculated for a joint as presented in the diagram with seam thickness and reinforcement as outlined in the following sections. The steel boxes and the seam must be fully filled with concrete. The capacities given are the resistances in ultimate limit state, so please compare to design loads. Longitudinal Force Capacity Boxes Centre Design Value of Longitudinal Shear Resistance, VRd (kn/m) to Centre Standard Maxi Double Thin Double Wide CFS-RVL-60, -80, -100, -120 CFS-RVL-140 CFS-RWL-THIN CFS-RWL-WIDE C25/30 C40/50 C25/30 C40/50 C25/30 C40/50 C25/30 C40/50 250 125 159 112 116 300 117 148 94 98 141 154 350 101 128 182 230 81 84 120 132 400 89 112 163 207 70 74 106 118 450 79 100 146 184 63 66 95 106 500 72 91 131 166 56 59 85 96 550 66 83 120 152 51 54 77 87 600 60 76 110 139 46 49 70 80 650 56 71 102 129 43 45 64 73 700 52 66 95 120 40 43 60 69 750 49 62 37 40 55 63 The resistance is defined by the weakest concrete in the system, either to fill the joint or the concrete used to make the precast element. 12-5 www.cfsfixings.com

Tensile Capacity Capacities are shown here per box, thus for Standard and Maxi boxes the capacities are for a single wire rope pair, and for the double boxes are for two wire rope pairs. Box Type Part No Design Value of Tensile Resistance, FRd (kn) C25/30 C40/50 CFS-RVL-60 Standard CFS-RVL-80 CFS-RVL-100 CFS-RVL-120 12.9 12.9 Maxi CFS-RVL-140 23.1 23.1 CFS-RWL-THIN Double CFS-RWL-WIDE 17 25.8 The resistance is defined by the weakest concrete in the system, either to fill the joint or the concrete used to make the precast element. The distance between wire loop boxes must be as defined later in this section. Horizontal Shear Force Capacities are shown here per box, thus for Standard and Maxi boxes the capacities are for a single wire rope pair, and for the double boxes are for two wire rope pairs. Box Type Part No Design Value of Horizontal Shear Resistance, NRd (kn) C25/30 C40/50 CFS-RVL-60 Standard CFS-RVL-80 CFS-RVL-100 CFS-RVL-120 4.6 5.8 Maxi CFS-RVL-140 8.2 10.3 CFS-RWL-THIN Double CFS-RWL-WIDE 10.8 13.6 The resistance is defined by the weakest concrete in the system, either to fill the joint or the concrete used to make the precast element. The distance between wire loop boxes must be as defined later in this section. PRECAST WALL CONNECTION WIRE ROPE BOXES Combined Forces For circumstances where there is a combination of forces on the wire loop joints, the following must apply: V Applied + F Applied + N Applied 1 V Rd F Rd N Rd www.cfsfixings.com 12-6

Installation Seam Thickness The size of the wire rope loops must be chosen according to the thickness of the joint to enable the vertical ribbed steel bar in the joint to pass through the wire rope loops on both side of the joint. Box Type Part No Recommended thickness of rope loop seam (mm) CFS-RVL-60 70-90 Standard CFS-RVL-80 90-110 CFS-RVL-100 110-140 CFS-RVL-120 140-190 Maxi CFS-RVL-140 160-220 Double CFS-RWL-THIN 90-130 CFS-RWL-WIDE 110-160 Minimum Edge Distance and Spacing Centre to centre Emin = minimum distance between wire rope loops at the same side of the joint. Edge distance Dmin = the minimum distance of the wire rope loop to the upper and lower edge of the concrete element (see diagram for double boxes). Centre to centre Cmax = minimum distance between wire rope loops at opposite sides of the joint. Minimum width Bmin = minimum total wall width. Dimensions for Standard and Maxi Boxes Dimensions for Double Boxes Box Type Part No Centre to Centre E min Edge Distance D min Centre to Centre C max Minimum Width B min mm CFS-RVL-60 Standard CFS-RVL-80 CFS-RVL-100 CFS-RVL-120 250 100 20 120 Maxi CFS-RVL-140 350 200 25 150 Double CFS-RWL-THIN 250 250 20 80 CFS-RWL-WIDE 300 300 25 100 12-7 www.cfsfixings.com

Reinforcement of the joint When using wire rope loops, a vertical ribbed steel bar must always be installed through the wire loops as shown here. Box Type Part No Diameter of the ribbed steel bar Øs Standard CFS-RVL-60 12 CFS-RVL-80 CFS-RVL-100 CFS-RVL-120 Maxi CFS-RVL-140 16 Double CFS-RWL-THIN 12 CFS-RWL-WIDE Reinforcement of Concrete Elements Reinforcing steel A500HW or similar Case Study 1 Diagrams The wall elements must be reinforced according to the wall element design. Case 1 Where wire loops are used to transfer forces When RVL wire rope loops are used to transfer forces in the joint, anchorage of the wire rope loop must be secured by overlapping the wire rope loop sufficiently with the reinforcement of the concrete element. This should be done to the engineer s design depending on your precise arrangement. Where the wire loop is used in a corner joint a reinforcing bar should be installed into the inner edge of the fold of the RVL wire rope loop, the diameter of this bar should be the same as the reinforcement installed in the joint. Case 2 Where RVL wire loops are not used to transfer forces When wire rope loops are used to limit cracking of the seam or to tie elements together without defining the required force, additional reinforcement in the wall is recommended as shown here, including 2 No 10mm diameter additional bars in each piece. Attachment to the formwork The wire rope loop box must be attached securely so it cannot move during casting of the concrete. At the wire rope loop, the concrete must be compacted carefully as the loop cannot be vibrated. The wire rope loops Loop boxes may be fastened to formwork with nails or by magnets. The part of the wire rope which enters the concrete element is installed amidst the reinforcement and does not need to be tied to the reinforcement. Case Study 2 Diagrams PRECAST WALL CONNECTION WIRE ROPE BOXES www.cfsfixings.com 12-8

Supervision of Installation Check list before casting: Wire rope loop is in good condition Wire rope loop is according to designs and in the right place Wire rope loop is attached firmly The required additional reinforcement is installed. During the casting: Wire rope loop stays in the right place The concrete is thoroughly vibrated around the RVL wire rope loop. After the casting: The tape covering the steel box is removed at the factory after the concrete is cured. Manufacturing Our RVL wire rope loops are manufactured by R-Group Finland Oy. Manufacturing markings The product packaging includes a R-Steel sticker, containing the following information: product type, product name, quantity, ISO9001 and ISO14001 quality and environmental system markings, FI marking and product picture. Products are delivered in cardboard boxes marked with FI and BY (Concrete Association of Finland) logo and the number of certified product declaration, numbers of the ISO-certificates and the product type and name. Quality control Quality control of the wire rope loops is done according to the requirements of the Finish Code of Building Regulation and the instructions according to the quality and environment system of R-Group Finland Oy (ISO 9001 and ISO 14001). 12-9 www.cfsfixings.com

R-Steel Loops R-Steel Loops are used to tie precast concrete elements to the building frame using a reinforcement bar through the loops and casting some concrete insitu. They are similar to the RVL Wire Loop in application. The wire boxes have the advantage of ease of casting and protection of the loop, however the R-Steel loops can be used in thinner panels and can also be used for lifting. PRECAST WALL CONNECTION WIRE ROPE BOXES www.cfsfixings.com 12-10

Dimensions Materials Part Material Standard Wire rope high strength steel wire SFS-EN 12385 SE-Zn Compression sleeve 1.0046 SFS-EN 10025 Capacities Design principles: The capacities presented in the tables below are calculated for ultimate limit states according to the following codes and regulations: SFS-EN1992-1-1 SFS-EN1993-1-1 R Steel loops cannot be welded. Capacity for element tying Ultimate limit capacity for horizontal force, NRd = 4.8kN Concrete strength C25/30. This design is for a static load, for dynamic load please seek advice from CFS technical help. Capacity for element lifting The R-Steel Loop can be used for lifting concrete elements, according to the diagram below as long as the following are met: Lifting angle must be between 0 and 45 R-Steel Loop resistance for lifting FRd = 1.9kN (concrete C15/20) Lifting device diameter must be 40mm 12-11 www.cfsfixings.com

Installation Minimum Edge Distance and Spacing Minimum edge distance from sleeve, e = 15mm A reinforcing bar needs to be provided in the element as shown above to prevent the loop bursting out of the wall. Reinforcement Anchoring reinforcement must be installed through the R-Steel Loop and it must be anchored to cast in situ concrete. Reinforcement to be A500HW or similar. Supervision of Installation Check before casting: R-Steel loop is in good condition R-Steel loop I according to design and in the right place R-Steel loop is attached firmly The additional reinforcement is installed During casting: R-Steel loop stays in the right place The concrete is thoroughly vibrated around the R-Steel loop After casting: The situation of the R-Steel loop is according to the design Attachment to the formwork The R-Steel Loop and anchoring reinforcement must be securely attached and must not move during casting. The R-Steel Loop may not be vibrated during casting. Manufacturing R-Steel loops are manufactured by R-Group Finland Oy. Manufacturing markings The product packaging includes a R-Steel sticker, containing the following information: product type, product name, quantity, ISO9001 and ISO14001 quality and environmental system markings, FI marking and product picture. Products are delivered in cardboard boxes marked with FI and BY (Concrete Association of Finland) logo and the number of certified product declaration, numbers of the ISO-certificates and the product type and name. Quality control Quality control of the wire rope loops is done according to the requirements of the Finish Code of Building Regulation and the instructions according to the quality and environment system of R-Group Finland Oy (ISO 9001 and ISO 14001). PRECAST WALL CONNECTION WIRE ROPE BOXES www.cfsfixings.com 12-12