FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications



Similar documents
FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Orion2+ SHDSL.bis Solution with 11Mbit/s and 15Mbit/s per Copper Pair

SHDSL LAN EXTENDER H301A. User Manual

Long Range Ethernet Extender

S-Access Etherlink II Repeater TDM Based SHDSL.bis

Extending E1 and Ethernet using the same Copper Pairs

FlexGain Platform. Universal Access Platform. SHDSL.bis and Fiber Access Platform Ddd & Management. Features

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

FlexCON VoIP. Industrial VoIP GW and Serial Converter. FXO, FXS, VF, Serial Industrial VoIP Ddd. Ethernet. Features

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Loop-IP6702 TDMoEthernet

N560 series H/W Installation Guide

Fiber Optic Connectivity SECURITY SURVEILLANCE SOLUTIONS. ComNet Managed Ethernet Switches

HARTING mcon 1000 Introduction and features

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

T3 Mux M13 Multiplexer

Moxa EtherDevice Switch

Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet

Cisco G.SHDSL High Speed WAN interface Card with IEEE 802.3ah EFM Support for Cisco Integrated Services Routers

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

Business Access. Universal Line Access Family

HARTING econ 3000 Introduction and features

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

LBNP RS-232/485/422 serial device server. User manual

CHRONOS. Ethernet Demarcation. Smart Access Network Device. Features. Introduction

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

Provides one channel for Ethernet over existing

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

4 Ports + 3 SFP Gigabit Smart Switch Use Manual. Ver.A0

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7

Flexible Converged Services System Type 1 Encryption Hub (FCSS-T1E Hub)

TX2123 RS485 TO ETHERNET ADAPTOR

PCS0100en Persy Control Services B.V. Netherlands

SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series

10/100/1000 Base-T to Gigabit Fiber Media Converter

Industrial Ethernet Switches

c o m m u n i c a t i o n n e t w o r k s

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

SHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

EGS7228P. Business Class EGS7228P. 24-port Gigabit AT PoE + 4SFP Smart Switch PRODUCT OVERVIEW

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

784 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES. (REV ) (FA ) (7-12)

16x10/100/1000Base-T(X) ports and 8x100/1000Base-X, SFP socket

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

One Port Serial Server Users Manual Model ESP901, ESP901E

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

Ha-VIS FTS 3000 Introduction and features

RGPS-7084GP-P. Industrial 12-port rack-mount managed Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E. ports and 4x1000Base-X, SFP socket

Octal T1-10/100 RIOP Installation Guide

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

SOHOware Long Reach Ethernet (LRE) Solution

1.3. The network element must have the ability to be configured in a point to point, point to multi point, and daisy chain configuration.

1Industrial Ethernet Switch

8x10/100/1000Base-T(X) ports and 12x100/1000Base-X, SFP socket

Ethernet Link SGI-4844F

Loop-IP6700 TDMoEthernet

GEU Port Gigabit Switch

How To Manage An Ethernet Switch On An Industrial Network

ORION TELECOM NETWORKS INC. T1

IGS-9812GP. Industrial 20-port managed Gigabit Ethernet switch with 8x10/100/1000Base-T(X) ports and 12x100/1000Base-X, SFP socket.

Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet

TDMoEthernet. Description

Telephone- and leased line modem for industrial applications TD-36

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

CREATING YOUR OWN RF SWITCHING SYSTEM

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

3500/22M Transient Data Interface

Loop-IP6510 Multiple WAN Router/Bridge

HARTING econ 4000 Introduction and features

IES-P3073GC Series. Industrial IEC port managed Ethernet switch with 7x10/100Base-T(X) and 3xGigabit combo ports, SFP socket.

Speed-DSL 9.2 Ethernet connection over 8-wires up to 9.2 Mbit/s. Manual * * * *

IntesisBox KNX Modbus TCP master

Gigabit Switching Ethernet Media Converters - Product User Guide

VAC 50/60Hz Power Adapter

NetScanner System. Toronto: , Montreal: , Toll Free: ,

This is a product of VCCI Class B Compliance

Perle 10/100 Ethernet Media Converters

Provides one channel for Ethernet over existing

USB to RS-422/485 Serial Adapter

Product Specifications

Media Converters & Chassis

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

NetPlug200 Nano.

8-Port PoE Network Switch

1 Serial RS232 to Ethernet Adapter Installation Guide

Configuring the Switch with the CLI Setup Program

IKS PoE Series. 24+4G-port Gigabit modular managed PoE+ Ethernet switches. Introduction. Industrial Ethernet Solutions. Features and Benefits

Loop Telecom. Total Access Solutions for Enterprise Network, Cellular & Gateway Operator.

Ethernet Link SGI-2424

Cable Pinouts. SRP I/O Module

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s. Manual

Transcription:

SHDSL.bis Up to 30Mbps Ddd Ethernet FlexDSL MiniFlex Features Up to 15Mbps Data Transmission per Copper Pair SHDSL and SHDSL.bis, TC-PAM16/32 Additional TC-PAM4/8/64/128 Available 1 or 2 Copper Pairs Support 2 Port Ethernet Switch (10/100BaseT) QoS, VLAN and RSTP Support Point-to-Point and Point-to-Multipoint Operation Fiber Optic Converter Version Available with 1 Ethernet Port and SFP Console Port, Telnet, Web, SNMP Management 24/48VDC or 110/230VAC Powered, Low Power Consumption Included Primary Protection Robust DIN-Rail Metal Enclosure Smallest Size Industrial Temperature Range Available The FlexDSL Orion3 and MiniFlex SHDSL.bis product family offers a broad range of products, which are based on the latest SHDSL.bis standards (ITU-T G.991.2 & ETS TS 101524), while also being fully interoperable with all our existing SHDSL equipment (Orion1, Orion2). The FlexDSL MiniFlex supports beside of the standardized TC-PAM16/32 also the new extended TC-PAM4/8/64/128 line coding. The support of these extended line codes ensures compatibility with existing SHDSL equipment, that is already installed, in order to protect customer investments, while at the same time providing an upgrade path to the newest DSL technologies. The MiniFlex product family supports beside of SHDSL.bis copper transmisson a dinrail Fiber Converter unit. It has equal dimensions and supports datarates up to 100Mbps over fiber. SHDSL.bis allows symmetrical data and voice transmission at speeds up to 15Mbps over a single pair of copper. In addition, the FlexDSL MiniFlex SHDSL.bis modem range also supports DSL channel bonding for up to 2 copper pairs in order to achieve speeds to 30.4Mbps!!. An integrated 2 port Ethernet layer 2 managed switch with VLAN, QoS and RSTP support (10/100BaseT) ensures connectivity to IP services. The FlexDSL MiniFlex SHDSL.bis modems is a perfect solution for a wide range of applications in which IP services need to be transmitted over copper wires. The MiniFlex product is a small-sized Orion3 unit with all the functionality included. Like all FlexDSL Orion products the FlexDSL MiniFlex SHDSL.bis modems are based on industrial components and manufactured according to highest quality standards providing additional value due to the extended temperature ranges and higher reliability. The combination of comprehensive functions providing maximum flexibility together with the higher quality of the FlexDSL MiniFlex SHDSL.bis product family make it the perfect choice for all your DSL needs. Possible Applications a) b) c) a) Ethernet Transmission Point-to-Point b) Ethernet Transmission Point-to-Multipoint c) Ethernet Add/Drop over a Long Copper Line Switzerland Page 1/5

Quick Installation Guide Enter a MiniFlex Device You can use the Monitor (Local Craft Terminal, USB) interface with Hyper Terminal (or any equal program) or you can address the device with Telnet through the Ethernet interface. Monitor (LCT, USB) Interface: Configure the COM port: Bits per second:9600, Data bits: 8, Parity: None, Stop bits: 1, Flow control: None Press <ENTER>. Telnet through Ethernet Interface: Type in command line <Telnet 192.168.0.235> and press <ENTER>. This is the default Ethernet Address for MiniFlex devices. After a successful entering the main menu of the device will be displayed. Configure a MiniFlex Device A first installation example with the most important commands and points to care about is shown below. We just like to have an Ethernet transmission between the two devices over 2 SHDSL copper pairs with a speed of 11.4Mbit/s. The pairs should aggregate (bundle) the data traffic and in case of any SHDSL pair failure, the remaining pairs should continue to work. Computer Device 1 Device 2 Enter in device 1 with the Monitor (LCT, USB) or Telnet interface. Type following commands Description 3 < > Go to Configuration Management (CM) <DEFAULT EVERYTHING> < > Set everything to default configuration <MASTER ON 1> < > Configure SHDSL 1 as MASTER <MASTER ON 2> < > Configure SHDSL 2 as MASTER <PAYLOAD WAN 1> < > Configure Ethernet over SHDSL 1 <PAYLOAD WAN 2> < > Configure Ethernet over SHDSL 2 <NET> < > Go to NET menu <SETIP 10.0.2.200> < > Set the IP-address of the device <NETMASK 255.0.0.0> < > Set the subnet mask <GATEWAY 10.0.0.101> < > Set the default gateway Go to Configuration Management (CM) Go to Main Menu <APPLY ALL> < > Apply all configurations (written in the running config.) <CONFIRM> < > Confirm all configurations (written in the startup config.) In Menu Configuration Management (CM) you can type <CONFIG> to see the following picture: CO_CM>CONFIG Running Line Configuration xdsl DSL1 DSL2 Mode : Master(HTU-C) Master(HTU-C) Extended rates: OFF OFF Line coding : PAM32 PAM32 Baserate : 89 89 Annex : B B Payload : WAN WAN Clock source : Int Int GS compatible : OFF NM threshold : OFF LA threshold : OFF CO_CM> Switzerland Page 2/5

Enter in device 2 with the Monitor (LCT, USB) or Telnet interface. Type following commands Description 3 < > Go to Configuration Management (CM) <DEFAULT EVERYTHING> < > Set everything to default configuration <MASTER OFF 1> < > Configure SHDSL 1 as SLAVE <MASTER OFF 2> < > Configure SHDSL 2 as SLAVE <PAYLOAD WAN 1> < > Configure Ethernet over SHDSL 1 <PAYLOAD WAN 2> < > Configure Ethernet over SHDSL 2 <NET> < > Go to NET menu <SETIP 10.0.2.201> < > Set the IP-address of the device <NETMASK 255.0.0.0> < > Set the subnet mask <GATEWAY 10.0.0.101> < > Set the default gateway Go to Configuration Management (CM) Go to Main Menu <APPLY ALL> < > Apply all configurations (written in the running config.) <CONFIRM> < > Confirm all configurations (written in the startup config.) In Menu Configuration Management (CM) you can type <CONFIG> to see the following picture: CP_CM>CONFIG Running Line Configuration xdsl DSL1 DSL2 Mode : Slave(HTU-R) Slave(HTU-R) Extended rates: OFF OFF Line coding : PAM32 PAM32 Baserate : 89 89 Annex : B B Payload : WAN WAN Clock source : Int Int GS compatible : OFF NM threshold : OFF LA threshold : OFF CP_CM> The idea is the following: the default settings help any device to be in an initial state, then the MASTER/SLAVE mode is enabled on the modem, then the transmit data is configured, then the network settings are configured (IP address, default subnet mask and default gateway) and finally, these settings are applied and then are written in the EEPROM. ATTENTION DON T FORGET TO WRITE THE CONFIGURATION IN THE STARTUP CONFIGURATION WITH THE FOLLOWING COMMANDS: <APPLY ALL> < > Apply all configurations (written in the running config.) <CONFIRM> < > Confirm all configurations (written in the startup config.) Switzerland Page 3/5

Connector Description SHDSL Technical Specification SHDSL Connector Specification Specification ITU-T G.991.2 G.shdsl and G.shdsl.bis Pin No Description Line Code TC-PAM16/32, Extended: TC-PAM4/8/64/128 1 SHDSL interface A Impedance 135Ω 2 SHDSL interface A Transmit Power 13.5 (Annex A) or 14.5 (Annex B) dbm @ 135Ω 3 SHDSL interface B Number of Pairs 2 4 SHDSL interface B Bit Rate Overvoltage Protection 192 to 5704kbit/s, Extended: 128 to 15232kbit/s ITU-T Rec. K.20/K.21 Phoenix Mini Combicom MC 1,5/4-GF-3,5 (female), 4 pins. Matching Type for the cable FK-MCP 1,5/ 4-STF-3,5 For AWG 16-26, Area 0.14 1.5 mm 2 or Diameter 0.4-1.4 mm Fiber Optic Technical Specification (100Base-FX) Standard Number of Interfaces 1 IEEE-802.3, VLAN/QoS IEEE-802.1q/p Data Rate 100BaseT, Full/Half Duplex, Ethernet Type SFP Tyco 1658391-1 Recommended 155Mbps SFP Transceiver (Fast Ethernet, OC-3, STM-1): LS38-A3S-TC-N XGSF-03-1503-80 SFP Connector Ethernet Technical Specification Ethernet Connector Specification Standard IEEE-802.3, VLAN/QoS IEEE-802.1q/p Pin No Description Number of Interfaces 2 or 1 1 Tx+ (transmit data) Data Rate 10/100BaseT, Full/Half Duplex 2 Tx- (transmit data) Protocols Data, Telnet, SNMP, WEB 3 Rx+ (receive data) Signal Level Ethernet 4 NC (not used) MDI/MDI-X auto crossover Supported 5 NC (not used) Auto Negotiation Supported 6 Rx- (receive data) RJ45 Female, 8 pin 7 NC (not used) Monitor/Local Craft Terminal Technical Specification 8 NC (not used) Monitor/LCT Connector Specification Specification USB V2.0 full and low speed Pin No Description Data Rate 12Mbit/s 1 +5V Protocol Master/Slave, Uses the USB communication 2 Data - Power Supply Technical Specification device class (CDC) drivers to take advantage of 3 Data + the installed PC RS-232 software to talk over the 4 NC (not used) USB 5 SGND USB Type Mini-B female connector Power Supply Connector Specification Specification ETSI ETS 300 132-2 Pin No Description Voltage (-24V models) 18-72VDC local power 1 Negative power terminal or N (Neutral power terminal) Voltage (-230V models) 85-264VAC, 120-370VDC local power 2 Protection ground Phoenix Combicom Positive power terminal or 3 MSTB 2,5/ 3-GF-5,08(male), 3 pins. L (Life power terminal) Matching Type for the cable FKCT 2,5/ 3-STF-5.08 For AWG 12-24, Area 0.2 2.5 mm 2 or Diameter 0.5-1.75 mm Power Consumption Typically 4 Watts Switzerland Page 4/5

Panel Description MiniFlex SHDSL Connector LED RED GREEN AMBER OFF xdsl 1 (DSL No 1) 1 DSL not working DSL normal operation xdsl 2 (DSL No 2) 2 DSL not working DSL normal operation Ethernet 1 and 2 Left Blinking = Data Connection not active Ethernet 1 and 2 Right 100 Mbit/s data rate 10 Mbit/s data rate Panel Description MiniFlex FOM Connector LED RED GREEN AMBER OFF SFP 2 No SFP module SFP active 100 Mbit/s data rate No Power Ethernet 1 1 System Error Ethernet active Blinking = Data Connection not active Ethernet 1 Left Blinking = Data Connection not active Ethernet 1 Right 100 Mbit/s data rate 10 Mbit/s data rate Environment, EMC and Safety Storage: ETS 300 019-1-1 Class 1.2 (-25 C +55 C) Transportation: ETS 300 019-1-2 Class 2.3 (-40 C +70 C) Operation: ETS 300 019-1-3 Class 3.2 (-25 C +70 C) ETS 300 019-1-3 Class 3.4 When inside an outdoor rack Higher Operation Temperature range available on request (-25 C +80 C) Dimension: 143(W)x87(D)x37(H) mm, 153(W)x87(D)x37(H) mm with Clip Weight < 0.5kg in Metal DIN-Rail Enclosure Standards: EN 300386 V1.4.1:2008 EN 55024/A2:2003 EN 61000-4-5:2006 EN 50121-4:2006 EN 61000-4-2/A2:2001 EN 61000-4-6:2007 EN 60950-1:2006 EN 61000-4-3:2006 EN 61000-4-6/A1:2001 EN 55022:2006, Class B EN 61000-4-4:2004 Available Models Ordering Code Interfaces Power Supply Attention! MF-PAM-RAIL2N-2Eth-24V, V1 2xDSL 2xETH 18-72VDC MF-PAM-RAIL2N-2Eth-230V, V1 2xDSL 2xETH 110/230VAC MF-FOM-RAILN-Eth-24V, V1 1xFOM (SFP Cage) 1xETH 18-72VDC MF-FOM-RAILN-Eth-230V, V1 1xFOM (SFP Cage) 1xETH 110/230VAC Switzerland Page 5/5