InsightPower Client. Shutdown Management Software for Windows 2000/XP/2003. User s Manual



Similar documents
SNMP-NET Client Shutdown Management Software for Windows 2000/XP/2003 User s Manual

SentryPlus. Shutdown Management Software for Windows. User s Manual

Bulletin 1609 UPS Management Software

Belkin Bulldog Plus. Shutdown Management Software for Windows. User s Manual

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

Belkin Bulldog Plus Shutdown Management Software for Windows

Using the UPSMON-Plus Monitoring Software

Sentry Bulldog Shutdown Management Software (For UNIX Series)

User s Manual. Management Software for ATS

Netwatch Installation For Windows

Installation and Configuration User's Guide

User Manual WatchPower

Belkin. Automatic Power Management Software. User s Manual

UPS Monitoring Software. User manual Borri Power Guardian

How To Set Up Power Supply On Windows (Windows) With Powerup (Windows 8) On Windows 7.1) On A Pc Or Windows 8 (Windows 7) On An Ipad Or Ipad (Windows Xp

ECView Pro Network Management System. Installation Guide.

Network Management Card. User Manual

Motorola Phone Tools. Quick Start

User s Manual. Management Software for Inverter

Keystone 600N5 SERVER and STAND-ALONE INSTALLATION INSTRUCTIONS

CANON FAX L360 SOFTWARE MANUAL

User s Manual. Management Software for Uninterruptible Power Supply Systems

ViewPower User Manual

Driver Upgrade Instructions

Citrix Client Install Instructions

User's Reference Guide for PowerAlert UPS Management Software Version 10.2 for Windows

ViewPower Pro. User s Manual. Management Software for Uninterruptible Power Supply Systems

SharePoint Wiki Redirect Installation Instruction

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.

ViewPower Pro. User s Manual. Management Software for Uninterruptible Power Supply Systems

Table of Contents MONITORING SOFTWARE USER MANUAL

Control Software for UPS with LAN-Ethernet Interface

Liebert MultiLink. User Manual - Fundamental & Advanced

Winpower. User Manual.

Software Repair Assistant Manual for DuraXV

UPS Monitoring and Management Software

Installing the Microsoft Network Driver Interface

Monitor TemPageR 4E With PageR Enterprise

KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7

Virtual Office Remote Installation Guide

SNMP Manager User s Manual

Moxa Device Manager 2.0 User s Guide

SOS Suite Installation Guide

UPS MONITORING SOFTWARE USER MANUAL

Shutting down / Rebooting Small Business Server 2003 Version 1.00

UPS Monitoring Software User Manual. Emily2

ACTIVE DIRECTORY DEPLOYMENT

Richmond Systems. SupportDesk Quick Start Guide

Standard Client Configuration Requirements

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

owncloud Configuration and Usage Guide

CODESOFT Installation Scenarios

USB Edition TM-STD30 User Guide

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

UPSentry Smart 2000 Shutdown Management Software for Windows

Network Setup Guide. Introduction. Setting up for use over LAN

Using Virtual PC 7.0 for Mac with GalleryPro

Browser Client 2.0 Admin Guide

Winpower. User Manual. To find user manual in other languages and software updates, please visit for more information

UPSentry Smart User s Manual. Shutdown Management Software. for Mac OS X 10.2

Configuring NXT Hardware with Mercury Inside into Doors.NET TM Application Note

Set Up Setup with Microsoft Outlook 2007 using POP3

Client Program Installation Guide

WhatsUp Event Alarm v10.x Listener Console User Guide

Remote Access for Cisco Unity 8.x

KANTECH SCHEDULED EVENTS INSTALLATION MANUAL

Tufts VPN Client User Guide for Windows

Antivirus. Quick Start Guide. Antivirus

Wireless Remote Control of the TT24

AXIS 1440 Print Server For EPSON Printers: Product Update. Important Information for Windows

User and Installation Manual

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

Symantec Backup Exec TM 11d for Windows Servers. Quick Installation Guide

Installation Notes for Outpost Network Security (ONS) version 3.2

DataTraveler Secure - Privacy Edition

Option nv, Gaston Geenslaan 14, B-3001 Leuven Tel Fax Page 1 of 14

Tripp Lite PowerAlert

Deploying Windows Streaming Media Servers NLB Cluster and metasan

SITRANS RD500 Configuring the RD500 with PSTN or GSM modems and Windows-based servers and clients for communication Objective:

User Manual V1.0. Remote Software

Network FAX Driver. Operation Guide

Spector 360 Deployment Guide. Version 7

CentreWare Internet Services Setup and User Guide. Version 2.0

Rev 7 06-OCT Site Manager Installation Guide

Chapter 2 Dispatch Server

How To Backup Your Computer With A Remote Drive Client On A Pc Or Macbook Or Macintosh (For Macintosh) On A Macbook (For Pc Or Ipa) On An Uniden (For Ipa Or Mac Macbook) On

Microsoft SQL 2008 / R2 Configuration Guide

DOE VPN Client Installation and Setup Guide March 2011

Phone Network Gateway Android Application. User Guide

PowerPanel Business Edition Installation Guide

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

PowerPanel Personal Edition User Manual. User Manual. PowerPanel Personal Edition. Rev /02/24

Software Upgrade Assistant Manual for DuraXV

ilaw Installation Procedure

1. System Requirements

Setting up a VPN connection Windows XP

Hi-Speed USB 2.0 Flash Disk. User s Manual

FAQ. How does the new Big Bend Backup (powered by Keepit) work?

Big Kev s Little Services Monitor

Transcription:

InsightPower Client Management Software for Windows 2000/XP/2003 User s Manual

Table of Contents INTRODUCTION... 3 InsightPower Client features:...3 INSIGHTPOWER CLIENT INSTALLATION... 4 InsightPower Client Setup:...4 Configure InsightPower SNMP Card:...4 INSIGHTPOWER SERVICE... 7 INSIGHTPOWER MONITOR... 8 INSIGHTPOWER SERVICE - PROPERTY... 9 General:...9 Run Time:...9 Reaction:...9 Schedule:...10 2

Introduction InsightPower Client is designed to provide end users the ability to take proactive steps to protect their equipment from power related damages. InsightPower Client allows for automatic shutdowns, scheduled shutdowns and a variety of other features that help you manage your system and its peripheral components. InsightPower Client provides detailed information about the UPS and its protected equipment. It is easy to install and program, yet has the necessary features to handle all of one s power requirements. InsightPower Client runs in the background as a Windows service, and communicates with the UPS through SNMP in order to ensure that your computer and attached components are protected from any power problems. InsightPower Client features: 1. Graceful operating system shutdown 2. Scheduled tests, shutdown/restarts of the UPS 3. Notification: e-mail, audible alarm, network broadcasting and SMS 4. Real-time values of voltage, current, frequency and loading... 5. Historical data & graph 6. Network monitoring 7. Multi-computer shutdown/restart 8. Support Simple Network Management Protocol (SNMP) 3

InsightPower Client Installation InsightPower Client Setup: 1. Place the InsightPower CD in your CD-ROM device and execute the InsightPower Client Setup.exe to run the setup program. 2. Check the SNMP configuration of your UPS. 3. After finishing the installation, the setup process will create an InsightPower Client association. Help: InsightPower Client on-line help. Uninstall: To remove InsightPower Client from your hard disk. InsightPower Monitor: A user friendly interface, users can review event log and used to monitor your UPS. InsightPower Status: Reflect the status of InsightPower service program, the service program is used to communicate with your UPS. 4. Now the InsightPower Service should have run in your system, move your mouse over the system tray and click on the right button in the InsghtPower Status icon to pop up a menu. Select Property item and fill the IP or Host filed for the SNMP card and assign the community string. This community string should be the same as it is in the SNMP card SNMP Access Control page. Configure InsightPower SNMP Card: Before configuring the SNMP device you have to login as an administrator. Open the SNMP Access Control page and add your IP address and community string. Please note that the community string must be equal to the InsightPower Client s. If you would like to turn off the UPS after the operating system shutdown then select the read/write access level, otherwise, select the read only access level. An ideal plan for multiple server shutdown is select one or two servers which have the read/write access level which should be the latest shutdown server(s) and assign read only access level for the others. The scenario is as the following: Configuration: There are 3 servers which are powered by the UPS, all of them retrieve the UPS information through InsightPower SNMP card. In this case only one server is assigned the read/write permission to shutdown the UPS, the others are assigned read only access level to shutdown the operating systems. 4

SNMP Card HUB Network Line Power Line Read/write 10 min UPS: 2 min Read Only 5 min Read Only 5 min InsightPower Client Power Fail: Once power fail occurs, all of the servers begin to countdown for graceful shutdown. HUB SNMP Card Network Line Power Line Read/write 10 min UPS: 2 min 9:59 Read Only 4:59 Read Only 4:59 5 min 5 min Power Fail Continuously 5 Minutes: When the countdown timer reaches 0, InsightPower Client shuts down the operating system normally. HUB InsightPower Client SNMP Card Network Line Power Line Read/write 10 min UPS: 2 min 4:59 InsightPower Client Power Fail Continuously 10 Minutes: Before to shutdown the read/write permission server, InsightPower Client sends delay shutdown UPS command to the InsightPower SNMP card then shutdown the operating system. HUB SNMP Card Network Line 5 UPS: 2 min

Power Fail Continuously 12 Minutes: UPS shutdown to prevent from over discharged. HUB SNMP Card Network Line UPS: Power Line InsightPower Client 6

InsightPower Service InsightPower Service runs in the background as a Windows Service when the system initiates. You can also stop or start InsightPower Service manually by selecting the Start Menu- Control Panel Administrative Tools - Service. Once InsightPower Service starts the InsightPower Status icon will reflect its status in the system tray. Moving your mouse over the InsightPower Status icon in the system tray and click the right button to pop up the menu Console Monitor: Run the InsightPower Monitor, the user interface. Service Panel: Pop up the InsightPower Service panel, a brief panel for current UPS status. Property: Displays the property window, allow you to change the InsightPower Client parameters. Show Panel: Shows InsightPower Service panel when the system initiates. Topmost Panel: Always keep on the top most windows. Stop UPS Service: If this item marked InsightPower Client Service stop to communicate with InsightPower SNMP card. Unmark it and the program will resume. 7

InsightPower Monitor InsightPower Monitor enables you to monitor the UPS through the Main Screen. It is not necessary for InsightPower Monitor to reside in your computer s memory; the execution depends on the user's requirement. This can save precious system resources. Note: Only Windows administrator s accounts can have the right to use InsightPower Client. After finishing the InsightPower Client installation, InsightPower Service automatically loads into memory and runs once the Windows operating system starts up. There is an InsightPower Service icon that lies in the system tray to indicate current UPS status. To run the InsightPower Monitor, moves the mouse cursor over the InsightPower Service icon and double-click to launch InsightPower Monitor, or click the right button to pop up the menu then select Console Monitor to run the program. You can also launch InsightPower Monitor by select InsightPower Monitor from Program Files InsightPower Client menu. 8

InsightPower Service - Property General: Display the InsightPower Client version and UPS rating values here. IP or Host: This fields need to be assigned a correct IP address or host name of the InsightPower SNMP card. Community: The community is part of an identification of SNMP protocol; please make sure it is the same as it is in the InsighPower SNMP card SNMP Access Control page. The default value is public which has the read only access level. To upgrade the access level to read/write level you have to modify the SNMP Access Control web page from the SNMP device. Please assign the IP address where the InsightPower Client is installed, type the same community string as it has been assigned in the InsightPower Client, select the read/write access level then press the submit button. With the read/write access level, the InsightPower Client can send the control commands (shutdown/restart UPS and battery test commands) to the UPS. Time Server: Enable this option to run a network time service to provide time and date to the InsightPower SNMP card; meanwhile, the InsightPower SNMP card needs to be assigned the host IP address in the Time Server page. Cancel : This button is used to cancel current countdown timer. Pause Reaction: This button is used to pause current reactions but if another power event occurs the reactions will be resumed. Run Time: Users can plan the unattended shutdown timer here, if you would like to shutdown UPS after the OS shutdown you need to get a read/write access level from InsightPower SNMP card. To do that, please refer to the InsightPower Client Installation chapter. Reaction: There are 5 reactions for power events, including audible alarm, network 9

broadcast, e-mail, SMS and customer command. Please make sure the Messenger service is running if you want to broadcast message in the network. To send a short message to mobile phone, you need to prepare a GSM modem or mobile phone and connect it to the computer. InsightPower Client communicates with this local mobile phone through enhanced AT commands to send power message to another mobile phone. Schedule: InsightPower Client supports two kinds of shutdown schedule (1) Weekly Schedule; (2) Special Day Schedule. Set both of these options to plan your system schedule shutdown and restart time. To send the control commands of battery test and shutdown/restart UPS, please make sure the InsightPower Client has the read/write access level in the SNMP card. Users can check the access level from General page. 10