1204 Reflected Wave Reduction Device with Common Mode Choke (Catalog Number 1204-RWC-17-A)

Similar documents
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

MCR1900 Media Converter 19-Slot Chassis

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Power Supplies 3. SDN-P DIN Rail Series

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

CompactLogix Power Supplies Specifications

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Single Phase Soft Starter

LIEBERT VNSA Installation Sheet

AC and DC Drive System Installation Information

Bulletin 1489 Circuit Breakers. Selection Guide

Owner s Manual. For Automatic Transfer Switch Amp, Service Entrance/Non-Service Entrance

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Power Management Module 2. Installation

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

INSTALLATION INSTRUCTIONS

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Radiant Temperature Sensor TY7321

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Buck - Boost Transformers

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

1 Temperature Derating Guide

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Explosion-Proof Electric Unit Heaters

T7079A,B Solid State Remote Temperature Controllers

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

8146/5 Series Breaker Panelboards

Explosion proof enclosures

Absolute Rotary Encoder E6CP

Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

1321 Power Conditioning Products

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

Rotary Disconnect Switch Specifications

G670 Intermittent Pilot Ignition Controls

GRX-PWM Pulse Width Modulation Interface

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

E2 Series Electric Furnaces

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Bimetallic Overload Relay Specifications

Redundancy Module QUINT-DIODE/40

Conext Grid Tie Solar Inverter Conext TX 2800 NA Conext TX 3300 NA Conext TX 3800 NA Conext TX 5000 NA

Digi-Motor Installation Guide

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

AC-DC Converter Application Guidelines

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

ST Series POWER SUPPLIES USER INSTRUCTIONS

Addendum to the Operating Instructions

GEU Port Gigabit Switch

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

PowerFlex Dynamic Braking Resistor Calculator

Model 1210C Battery Powered Pump Shown. Description

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

LOXONE 12 Channel Amplifier

PSR The compact range Description

VSD Series Drives. November 2009 Supersedes September Powered by Eaton Technology. User Manual

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

Contractors Guide Central Inverter System Installation

HP UPS R1500 Generation 3

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

SURGE PROTECTIVE DEVICES

! WARNING. Before using product, read and understand instructions.

Parallel Redundant Uninterruptible Power Supply

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

Allen-Bradley HP AC Line Filter Kit

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

WE-350 Series ¼ Turn Electric Actuator

Specifying a Variable Frequency Drive s

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

HVAC DRIVE H300 HVAC Drive for Building Automation

Advantium 2 Plus Alarm

Data Bulletin Variable Frequency Drives and Short-Circuit Current Ratings

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

9000X AF Drives. User Manual. May 2011 Supersedes June 2009

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

A1000 Cheat Sheet (Open Loop Vector)

1756 ControlLogix Chassis Specifications

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

A99B Series Temperature Sensors

User Guide. AC Variable Speed Drives kW / 1HP - 250HP V Single and 3 Phase Input. Installation and Operating Instructions

Transcription:

Installation Instructions 1204 Reflected Wave Reduction Device with Common Mode Choke (Catalog Number 1204-RWC-17-A) This publication will guide you through installation (including mounting, wiring and grounding procedures) of the 1204 Reflected Wave Reduction Device with Common Mode Choke (1204-RWC). Contents Where this Option is Used.....................................1 Catalog Number Explanation...................................1 Specifications...............................................2 Nameplate Information.......................................3 Dimensions.................................................3 Determining the Maximum Cable Length for your System............4 Installation.................................................5 Where this Option is Used The 1204 Reflected Wave Reduction Device with Common Mode Choke (RWC) is designed to be used with Allen-Bradley 1336 family of AC drives with compatible current ratings. Call factory for advice on using the 1204-RWC with drives other than the 1336 family of AC drive. When installed near the drive, the device can reduce potentially destructive reflected wave spikes that can occur with long motor leads and reduces the effect of Common Mode noise. Catalog Number Explanation 1204 RWC 17 (1) A First Position Second Position Third Position Fourth Position Type Current Rating Mounting Config. Description Letter Description Code Rating Letter Mounting RWC A Book Style (2) Bulletin Number Reflected Wave Reduction Device IP20 (NEMA Type 1) 17 17.5 Amps at 380-480V, 12 Amps at 575-600V (1) Consult factory for 240V applications. (2) Chassis is rated IP20 (NEMA Type 1) for Book Style mounting.

2 1204 Reflected Wave Reduction Device with Common Mode Choke Specifications Input Power 380-600VAC, Three-Phase Carrier Frequency 2 khz Recommended (used for most applications) Important: 6kHz Absolute Maximum Refer to Chart below and page 4 for application restrictions. Ambient Temperature 0-50 Degrees C (32-122 Degrees F) Humidity 5-95% Non-Condensing Atmosphere Atmosphere should not contain hazardous (volatile) dust, vapor, gas or liquid. IP20 (NEMA Type 1) = Book Style Mount IP00 (Open Chassis) = Horizontal Mount Current Rating 17.5 Amperes at 480 Volts (12.0 Amperes at 600 Volts) Vibration 1.0 G Operational Agency Certification IND LISTED 966X CONT EQ Altitude Derating Above 1000 meters (3300 feet) derate at 6% of RWC rated amperes per 1000 meters (3300 feet) elevation to 4000 meters (13200 feet) maximum. Heat Dissipation Use the cable length and drive carrier frequency to find the approximate RWC losses for your system. Vertical movement inside the loss band will be dependent on exact cable type and motor load. Total Watts Loss Total RWC Losses (Watts) Total RWC Losses (Watts) Total RWC Losses (Watts) 240 210 180 150 120 90 60 30 0 240 210 180 150 120 90 60 30 0 240 210 180 150 120 90 60 30 0 0 61.0 (200) 0 61.0 (200) 0 61.0 (200) 121.9 (400) 4 khz 600V +10% 121.9 (400) 6 khz 600V +10% 6 khz 600V +10% 6 khz 480V +10% 121.9 (400) 182.9 (600) 182.9 (600) 182.9 (600) (1) Do not run unit above Rated Power. 2 khz Carrier Frequency 243.8 (800) 304.8 (1000) 365.8 (1200) Cable Length meters (feet) 4 khz Carrier Frequency 4 khz 480V +10% 243.8 (800) 6 khz Carrier Frequency 243.8 (800) 304.8 (1000) 304.8 (1000) 2 khz 600V +10% 365.8 (1200) Cable Length meters (feet) 365.8 (1200) Cable Length meters (feet) 396.2 (1300) 396.2 (1300) 396.2 (1300) 426.7 (1400) 426.7 (1400) 426.7 (1400) 2 khz 480V +10% 457.2 (1500) 457.2 (1500) 457.2 (1500) 487.7 (1600) 487.7 (1600) 487.7 (1600) Rated Power (1) Rated Power (1) Rated Power (1)

1204 Reflected Wave Reduction Device with Common Mode Choke 3 Nameplate Information The nameplate is located on the front of the unit. In addition, a manufacturing date is stamped on the bottom of the unit. Reflected Wave Reduction Device CAT 1204-RWC-17-A SER A Maximum Rating VOLTS AMPS 480V 3 17.5A 600V 3 12A Refer to manual for maximum cable length and drive carrier frequency. LISTED 966X WATTS 180W 180W IND CONT EQ Assembled in Mexico DANGER DISCONNECT AND LOCKOUT ALL POWER SOURCES BEFORE SERVICING SURFACES MAY BE HOT ALLOW TO COOL BEFORE SERVICING Dimensions Dimensions are in millimeters and (inches). Shipping weight = 4.1 kg (9.0 lb) 114.8 (4.52) 82.6 (3.25) 99.6 (3.92) 201.7 (7.94) 327.4 (12.89) 272.0 (10.71) 81.0 (3.19) 81.0 (3.19) 81.0 (3.19) 234.0 (9.21) 341.9 (13.46) 81.0 (3.19) 304.8 (12.00) 20.3 (0.80) 54.1 (2.13) 74.4 (2.93) 174.5 (6.87) 154.2 (6.07)

4 1204 Reflected Wave Reduction Device with Common Mode Choke Determining the Maximum Cable Length for your System The following tables will help you determine the maximum cable length for your system. 1336 Plus/Plus II/Impact/1336T 3.7-7.5 kw (5-10 HP) and 3.7-7.5 kw (5-10 HP) Motors Table A: 380-400V s Maximum Cable Length in meters (feet) Shielded (2) Unshielded Volts at Motor Carrier Nominal Line High Line Nominal Line High Line Motor Insulation (1) Frequency Voltage Voltage (3) Voltage Voltage (3) 1000 Type A 2 khz 488 (1600) 488 (1600) 488 (1600) 425 (1400) 1200 Type B 2 khz 488 (1600) 488 (1600) 488 (1600) 488 (1600) 1600 1329 R/L 2 khz 488 (1600) 488 (1600) 488 (1600) 488 (1600) Table B: 480V s Maximum Cable Length in meters (feet) Shielded (2) Unshielded Volts at Motor Carrier Nominal Line High Line Nominal Line High Line Motor Insulation (1) Frequency Voltage Voltage (3) Voltage Voltage (3) 1000 Type A 2 khz 488 (1600) 305 (1000) 182 (600) 60 (200) 4 khz 244 (800) 244 (800) 182 (600) 60 (200) 6 khz 76 (250) 75 (250) 76 (250) 45 (150) 1200 Type B 2 khz 488 (1600) 488 (1600) 488 (1600) 488 (1600) 1600 1329 R/L 2 khz 488 (1600) 488 (1600) 488 (1600) 488 (1600) Table C: 600V s Maximum Cable Length in meters (feet) Shielded (2) Unshielded Volts at Motor Carrier Nominal Line High Line Nominal Line High Line Motor Insulation (1) Frequency Voltage Voltage (3) Voltage Voltage (3) 1000 Type A 2 khz 90 (300) (6) (6) (6) 4 khz 90 (300) (6) (6) (6) 6 khz 60 (200) (6) (6) (6) 1200 Type B 2 khz 365 (1200) 305 (1000) 182 (600) 60 (200) 4 khz 120 (400) 120 (400) 120 (400) 60 (200) 6 khz 60 (200) 60 (200) 60 (200) 60 (200) 1600 (5) 1329 R/L 2 khz 365 (1200) 365 (1200) 365 (1200) 365 (1200) 4 khz 120 (400) 120 (400) 120 (400) 120 (400) 6 khz 60 (200) 60 (200) 60 (200) 60 (200) 1204-RWC Maximum Cable Length (4) 488 (1600) 244 (800) 75 (250) 1204-RWC Maximum Cable Length (4) 488 (1600) 244 (800) 75 (250) 1204-RWC Maximum Cable Length (4) 365 (1200) 120 (400) 60 (200) (1) Type A = No phase paper or misplaced phase paper, lower quality insulation systems, corona inception voltages between 850 and 1000 volts. Type B = Properly placed phase paper, medium quality insulation systems, corona inception voltages between 1000 and 1200 volts. 1329 R/L = Control Matched motors for use with Allen-Bradley drives, premium grade insulation system, typical corona inception voltage is 1600 volts. (2) Includes wire run in conduit. (3) High line condition is defined at rated input system voltage +10% with a fully rated motor condition. (4) Maximum cable length is restricted by power dissipation within the 1204-RWC package at 40 C (104 F) ambient under rated load. (5) When used on 600V systems, 1329 R/L motors have a corona inception voltage rating of approximately 1850V. (6) Not recommended with 1204-RWC. Call factory for advice on using the 1204-RWC with drives other than the 1336 family of AC drive.

1204 Reflected Wave Reduction Device with Common Mode Choke 5 Installation The following steps will guide you through mounting the Reflected Wave Reduction Device.!! ATTENTION: To avoid a shock hazard, ensure that all power to the drive has been removed before proceeding. In addition, wait 3 minutes for the DC bus to discharge. ATTENTION: Enclosure surfaces may be hot and can cause sever burns. Install in a location that minimizes accidental contact. Mounting 1. Assure that all power has been removed from the drive. 2. Attach the mounting brackets to the back of the chassis using the eight screws provided. The brackets can be positioned either flush or extended as shown below. 3.6 N-m 32 lb.-in. Brackets Extended Brackets Flush

6 1204 Reflected Wave Reduction Device with Common Mode Choke 3. Mount the device on a vertical metal surface and oriented so the wiring knockouts are on the bottom the device must be mounted within 3.0 meters (10 feet) of the drive. Important: To assure proper heat dissipation, minimum clearances must be maintained as shown below. 76.2 mm (3.0 in.) 25.4 mm (1.0 in.) 25.4 mm (1.0 in.) 38.1 mm (1.5 in.) 76.2 mm (3.0 in.)

1204 Reflected Wave Reduction Device with Common Mode Choke 7 Wiring 4. Wire the device as indicated below. The maximum and minimum wire size accepted by the RWC terminal block is 4.0 and 0.75 mm 2 (10 and 18 AWG). Use copper wire only with a minimum temperature rating of 75 degrees C. Maximum torque is 1.81 N-m (16 lb.-in.). AC 3.1 m (10 ft.) - Maximum Length from Terminal U from Terminal V from Terminal W from Ground Motor Ground Motor Phase U Motor Phase V Motor Phase W RWC Terminal Block U V W PE PE U1 V1 W1

8 1204 Reflected Wave Reduction Device with Common Mode Choke Grounding 5. Follow the recommended grounding practices provided in your drive User Manual. The following diagram shows an example of system grounding practices.! ATTENTION: National Codes and standards (NEC, VDE, BSI, etc.) and local codes outline provisions for safely installing electrical equipment. Installation must comply with specifications regarding wire types, conductor sizes, branch circuit protection and disconnect devices. Failure to do so may result in personal injury and/or equipment damage. Conduit/4-Wire Cable R (L1) U (T1) S (L2) V (T2) W (T3) T (L3) PE/GRD PE/GRD Motor Frame Ground Rod/Grid or Building Structure Steel RWC Ground per Local Codes Programming 6. The recommended drive carrier frequency for optimal RWC performance is 2 khz. The maximum carrier frequency allowed is 6 khz. If the drive default is higher than this maximum, the drive must be reprogrammed. Refer also to the Maximum Cable Length tables on page 4 for further information. 7. Carefully check that motor rotation is in the desired direction. Publication 1204-IN001A-EN-P February 2002 P/N 195686 Copyright 2002 Rockwell Automation. All rights reserved. Printed in USA.