/MCK BuyLine 6566 FIRE, SMOKE, SECURITY & EMERGENCY EGRESS DOOR SYSTEMS. McKEON DOOR COMPANY.

Similar documents
/CHI BUYLINE Rolling Steel. Buyer s Guide THE DOOR TO QUALITY.

STANDARD FOR NON-FIRE RATED ROLLING DOORS

Automatic Door Selection Guide

Learn how all this can be achieved. architecture AND save money. exceptional. with the SALT LAKE CITY, UT PERMIT # US POSTAGE PAID FIRST CLASS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

MODEL HSR-007 Direct Drive Rolling Steel

Safety. Fire Resistant. Gas Cylinder

SECURITY GRILLE SYSTEMS

SECTION MediaStation Model 125 Electric Lateral Files (ELF)

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

BUILDING PERMIT SPECIFICATIONS

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

SECTION FireGard ROLLING FIRE DOORS / SMOKESHIELD FIRE DOORS

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

Impact-Resistant Windows and Sliding Glass Doors

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

VERTICAL DESIGN OPTImAL ACOUSTICS

DESIGN CLARIFICATION (DC)

Single Package Vertical Air Conditioners. Vert-I-Pak

Enjoy the comfort and security of rolling shutters.

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

Building Code Clarifications - 7. Fire Resistance

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

garage door operators

Fire Resisting Rolling Shutters & Doors

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Morrison Bros. Co. General Product Specifications

Security Shutters, Retractable Security Gates, SeceuroBar & Aluminium Folding Shutter

Classroom Door Security & Locking Hardware

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

THIRD LAGUNA HILLS MUTUAL

Report Index PROPERTY DESCRIPTION 1 ELECTRICAL SYSTEM 2 COMMON INTERIOR AREAS 3 INTERIOR ROOMS 6 KITCHEN 8 BATHROOMS 10

Basic Fire Door Requirements

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

PAINT BOOTH LIGHTING

PART 1 GENERAL 1.1 SECTION INCLUDES

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM


Quality Building Products for over 50 Years

Floor-Concealed Door Closers with Electromagnetic Hydraulic Hold Open DORMA BTS80 EMB

Name Of Occupancy Date. Yes No Describe

Fire Resistant Systems

WHOLESALE DIRECT INC WEST 65TH STREET

AUTOMATIC OPENER SYSTEM FOR OUTSWING RESIDENTIAL GARAGE DOORS. Exclusively by:

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Steel Spill Containment Pallets

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

Coldrooms designed for your application

A Complete Solution CREATING WALLS THAT DEFINE SPACE

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

COMMONLY USED RESIDENTIAL BUILDING CODES

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Table of Contents. Inductive Loop Vehicle Detector Applications

220.5" Basic Features. Electrical Features

BLADE S-MAX Cabinet for Blade Server

Spray Booth Guideline

NetXtend Flex Series Integrated Outdoor Enclosure Solution. Outside Plant for Business-Critical Continuity

Protecting Your Home from Wind Damage

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Element D Services Heating, Ventilating, and Air Conditioning

IBC Tote Containment Sumps

How To Make A House Safe

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Relevant British, European and International standards

RS Security Co., Ltd. RS Security Co., Ltd is specialized in physical access control turnstiles;

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

JELCO EZ-LIFT & RotoLift Lift Cases

AirBlock Data Center Doors

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Secondary Unit Substations

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

AirBlock Data Center Doors

The replacement or modification of existing windows shall comply with the following requirements:

Range Equipment HVAC Design & Supply Modular Ranges

9300BC SERIES Light Commercial Door Closer

Fire Alarm System Plans Review Checklist Property location Date of Review

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

Art Basel Miami Beach Dec Booth Design Regulations

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

metal Duil~ing manufacturers Association

Magnum Mobile Generator MMG55 Specifications

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

Claridge Condominium Association, Inc Pelican Bay Blvd. Naples, FL 34108

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

2D & 3D TelePresence

Many Styles and Custom Options

The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options.

General Fire Code Requirements Within Commercial Tenant Spaces

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Transcription:

08 33 00/MCK BuyLine 6566 FIRE, SMOKE, SECURITY & DOOR SYSTEMS McKEON DOOR COMPANY 800-266-9392

PRODUCT GUIDE FIRE, SMOKE, SECURITY and DOOR SYSTEMS Fire and Smoke-Rated Doors and Shutters Emergency Egress p.4 VERTICAL COILING SYSTEMS Safescape Models T2000 & T2500 Automatic resetting Fire Door Systems, with built-in emergency egress. Available with one or two emergency egress doors. p.4 VERTICAL ACTING SYSTEMS Safescape Model T5000 Automatic Resetting Fire Door Systems with Emergency Egress. Available with up to 18 emergency egress doors. p.5 SIDE COILING SYSTEMS Safescape Models S9000 & S9500 Automatic resetting, emergency egress. One or two egress doors. Side activated doors can navigate around curves and contoured openings. p.6 SIDE ACTING FIRE DOORS S7000 Series Six side acting fire doors. Available with and without egress. Do not require battery back-up systems when activated in the self-closing fire condition mode. p.6 ACCORDION FIRE DOORS AC8000 Series Seven accordion folding fire door variations. Manual and motor operated, available with and without egress. 9 or 16 wide pockets. The doors with emergency egress options display this icon... Fire & Smoke Rated Doors and Shutters OUT Emergency Egress p.7 HORIZONTAL FIRE SHUTTERS Models H200 and HL250 Motor operated, fail-safe. Approved by UL and ITS up to 2 hour rated. Available with a smoke and draft rating and has been tested under UL 1784. p.5 SIDE COILING FIRE DOORS Auto-Set Model S4000 UL and ITS classified for up to 3 hours. Side activated, allowing doors to navigate around curves and contoured openings. p.8 COILING FIRE and SMOKE RATED DOORS Auto-Set Model FSFD For situations where fire protection is required, egress is not. Vertically acting fire door. UL, FM & ITS rated for up to 4 hours. p.8 INSULATED FIRE and SMOKE RATED DOORS Auto-Set Models FSFD-IS & FSFD-TR For interior or exterior applications where temperature and climatic control as well as fire ratings are required. p.11 ACOUSTICAL FIRE and SMOKE RATED DOORS Auto-Set Models FSFD-STC Model FSFD-STC is an acoustical coiling fire door. When used in pairs of doors the STC rating can reach up to 48. p.7 COILING FIRE and SMOKE RATED SHUTTERS Auto-Set Model CFS Available up to 28' 0 wide x 12' 0 high. For interior and exterior applications. Available with the Auto-Set hand crank or motor operated system. 2

PRODUCT GUIDE FIRE, SMOKE, SECURITY and DOOR SYSTEMS Non Fire Rated Service Doors and Grilles 08 33 00/MCK BuyLine 6566 p.9 SELF-OPENING SECURITY GRILLES - VERTICAL COILING Models G1000 & G1500 When both security and egress are issues. Activated by power failure, fire alarm or smoke system without the need for electricity or battery. p.9 SELF-OPENING SECURITY GRILLES - SIDE COILING Models G4000 & G4500 For both security and egress. Activated by power failure, fire alarm or smoke system without the need for electricity or battery. p.10 SIDE COILING DOORS and GRILLES SC3000 Series Side activated closures with curtains of solid slats, perforated curtain slats or of a security open type grille curtain. p.11 COILING SERVICE DOORS Model SD3000 Accommodate any opening size. Available in prime painted galvanized steel, aluminum, stainless steel or can be powder coat finished to any color requirement. p.11 COILING INSULATED SERVICE DOORS Model IS3000 Insulated with foamed-in-place polyurethane. Available in prime painted galvanized steel, aluminum, stainless steel or can be powder coat finished to any color requirement. p.10 HURRICANE SERVICE DOORS Model H3000 Accommodate the largest of openings. Built of up to 14 gauge steel or stainless steel curtains. They can sustain extremely high wind loads and heavy impact from flying debris. p.11 COILING SECURITY GRILLES Model SG3000 Vertical coiling units comprised of vertical links and horizontal rods. Can be manufactured in stainless steel, steel and aluminum and are available in a variety of finishes and patterns. p.11 COILING COUNTER SHUTTERS CS3000 Series Available to 28 width x 12 height. Interior and exterior applications. Available in either prime painted galvanized steel, stainless steel or powder coat finished any color. p.10 HORIZONTAL COILING SERVICE DOORS Models HS100 and HSL150 For openings of horizontal and inclined planes. Engineered for daily operation. Available in aluminum, stainless steel and in galvanized with prime paint or powder coated finish any color. CONTINUING EDUCATION Additional information also available: AIA Continuing Education Provider Program, Architectural Design Manual, CD with CAD Product Details and Technical Specifications, CD with Product Demonstrations, Videos and more... Browse and download DETAILS and SPECIFICATIONS from our website: 800-266-9392 3

Vertical Coiling Fire Door Systems Emergency Egress Safescape Models T2000 & T2500 Description: The automatic resetting Safescape T2000 Series Fire Door Systems, with built-in emergency egress, are vertical acting coiling fire doors that are available with one or two emergency egress doors. Ideal for openings in fire walls in excess of 8' wide x 10' high. Swinging emergency doors available up to 48 wide. Accommodate up to a 500 person occupancy load. Easy to test and automatically reset. No electricity or battery required to operate in the selfclosing fire condition mode. Retracts into plenum requiring little side room. Swinging emergency doors can be recessed into a wall cavity or pocket. Custom designed to any height and width APPROVED UP TO A 3 HOUR FIRE RATING Vertical Acting Fire Door Systems Emergency Egress Safescape T5000 Series Description: The automatic resetting Safescape T5000 Series Fire Door Systems, with built-in emergency egress are vertical acting, coiling fire doors and are available with multiple swinging type egress doors. Easy automatic testing and resetting. For areas of high occupancy load requirements typically in excess of 3,000 persons. The T5000 Series Fire Door Systems require a minimum amount of side room. They require approximately 9 feet of headroom. Undetectable in stored, fire-ready position. Requires no electricity or battery when in the self-closing fire condition mode. Products covered under U.S. Patents: 5,203,392-5,245,879-5,386,891-5,577,541-5,605,185-5,673,514-5,893,234 Additional patents are currently pending. 4

Side Coiling Fire Door Systems Auto-Set Model S4000 08 33 00/MCK BuyLine 6566 Description: Automatic resetting S4000 Fire Door Systems are side coiling fire doors that are UL and ITS classified for up to 3 hours. The S4000 Fire Door Systems are side activated which allow the doors to navigate around curves and contoured openings. Interruption of power or fire alarm automatically triggers the closing sequence. The fail-safe system uncoils the curtain (without electricity or battery) providing fire protection. The S4000 Fire Door Systems are easy to test and automatically reset. Require only 6 of headroom. Can be designed as biparting fire door systems. Do not require electricity or battery back-up systems when in self-closing fire condition mode. S4000 & S9000 Series Fire Door Systems Are Available Without Floor Tracks. APPROVED UP TO A 3 HOUR FIRE RATING Side Coiling Fire Door Systems Emergency Egress Safescape Models S9000 & S9500 Description: The automatic resetting Safescape S9000 (with built in emergency egress) can be provided with one or two emergency egress doors on their leading edge. S9000 Systems are side activated which allows for the doors to navigate around curves and contoured openings. Easy to test and automatically reset. Require only 6 of headroom Can be designed as bi-parting, allowing up to a 1,000 person occupancy load. Undetectable when in stored fire-ready position. Do not require electricity / battery back-up in self-closing fire condition mode. Products covered under U.S. Patents: 5,203,392-5,245,879-5,355,927-5,386,891-5,542,460-5,605,185-5,673,514-5,893,234 Additional patents are currently pending. 800-266-9392 5

Side Acting Fire Door Systems S7000 Series Description: Available in both manual and motor operated versions, with and without emergency egress doors. Units are fail safe by design and do not require battery back-up when activated in the self-closing fire condition mode. The S7000 Series Side Acting Fire Door Systems are easy to test and can be automatically reset. Require only 6 of head room, can be designed as bi-parting fire door systems. Undetectable in stored fire ready position. Some S7000 Series Fire Door Systems are available without floor tracks. Navigates around contoured openings. Without egress doors, they can navigate a 24 radius. This product is covered under U.S. Patents: 5,203,392-5,245,879-5,386,891 5,605,185-5,673,514-5,893,234 Additional patents are currently pending. APPROVED UP TO A 3 HOUR FIRE RATING Accordion Fire Door Systems AC8000 Series Description: Seven accordion fire door system variations. Available in both manual and motor operated and available with and without emergency egress doors. Standard 7 panels for a 9 pocket width or 14 panels for a 16 pocket width. Easy to test and can be automatically reset. Require only 6 of head room- can be designed as biparting fire door systems. Undetectable in the stored, fire ready position. Does not require floor tracks. Navigates contoured radius as small as 24. With egress doors they require a 5'-0 radius. S7000 & AC8000 Series Fire Door Systems Are Available Without Floor Tracks 6 This product covered under U.S. Patents: 5,203,392-5,245,879-5,386,891-5,605,185 5,673,514-5,893,234-6,615,894 Additional patents are currently pending.

Horizontal Fire and Smoke Rated Shutters Models H200 and HL250 08 33 00/MCK BuyLine 6566 APPROVED UP TO A 2 HOUR FIRE RATING Description: Motor operated fail-safe unit utilizing the Auto- Set operator. The unit is driven to the closed position by our patented self-closing mechanism. Tested and approved by UL and ITS up to 2 hour rating. Also available with a smoke and draft rating. The H200 is of a compact design and offers design professionals the flexibility of using one horizontal fire and smoke rated shutter in lieu of several conventional roll down fire doors to protect horizontal fire penetrations in a facility. This product is covered under US Patents: 5,203,392-5,245,879-5,355,927-5,386,891-5,542,460-5,605,185-5,673,514-5,893,234 Additional patents are currently pending. Counter Fire and Smoke Rated Shutters Auto-Set Model CFS Description: Auto-Set Counter Fire & Smoke Rated Shutters are available up to 28' 0 wide x 12' 0 high. These units are designed and manufactured to accommodate both interior and exterior applications. Self closes without electricity or battery back-up Requires very little head room and side room Easy to test and automatically reset Has been tested in accordance with UL 10B as well as UL 1784 and is also available with an "S" label APPROVED UP TO A 4 HOUR FIRE RATING These units are available in either prime painted galvanized steel, stainless steel or they can be powder coat finished to any color. Hand crank or motor operated. This product is covered under US Patents: 5,203,392-5,245,879 5,386,891-5,605,185-5,673,514-5,893,234 Additional patents are currently pending. 800-266-9392 7

Coiling Fire and Smoke Rated Doors APPROVED UP TO A 4 HOUR FIRE RATING Auto-Set Model FSFD Description: The Auto-Set fire door is a vertically acting fire door recommended when fire protection is required but emergency egress is not an issue. UL, FM & ITS classified up to 4 hours. In the event of a fire alarm, power failure, breaking the fusible link, or activation of the True Test Panel, the hold open brake is released and the door self-closes without electricity or batteries. The rate of descent is controlled by a centrifugal governor. Once the door is closed and the power is energized, or the alarm signal is cleared, the door will automatically reset without the need for tools or a technician. Custom built to any height and width Self-closes - no electricity or batteries Requires very little head & side room Easy to test and automatically reset Insulated and Acoustical Fire & Smoke Rated Doors Auto-Set Models FSFD-IS, FSFD-TR & FSFD-STC Insulated Fire Doors Auto-Set Models FSFD-IS & FSFD-TR Description: The FSFD-IS is designed for interior or exterior applications where climatic temperature transfer as well as fire rating is an issue. The model FSFD-TR is used in areas where a temperature rise rating is required. Both models are provided with the Auto-Set system. Insulated Fire Doors are compact in design, requiring minimum amount of head room and side room. 58 Ft Auto-Set Model FSFD Acoustical Fire Doors TM Auto-Set Model FSFD-STC Description: Model FSFD-STC is an acoustical coiling fire door. When used in pairs of doors the STC rating can reach up to 48. Both fire protection and sound reduction. Both units utilize the Auto-Set system. APPROVED UP TO A 4 HOUR FIRE RATING Products covered under US Patents: 5,203,392-5,245,879-5,386,891 5,605,185-5,673,514-5,893,234. Additional patents are currently pending. 8

Self-Opening Security Grilles Emergency Egress Vertical Coiling Models G1000 & G1500 08 33 00/MCK BuyLine 6566 Description: Vertical coiling units intended for use where both security and egress are issues. In an emergency, power failure, fire or smoke alarm, the security grilles move to the fully open position without the use of electricity or batteries. The G1500 includes an integral swinging emergency egress door. Self-Opening Grilles provide designers the flexibility of securing large openings while still providing emergency egress. When activated, the fail-safe system begins to open the security grille curtain without the aid of electricity of battery back-up Self-Opening Security Grilles Emergency Egress Side Coiling Models G4000 & G4500 Description: Where both security and egress are issues. In the event of an emergency, power failure, fire or smoke alarm, the security grilles move to the fully open position. No electricity or battery back up systems. The G4500 includes an integral swinging emergency egress door. Self-Opening Grilles provide designers the flexibility of securing large openings while still providing emergency egress. G4500 Series Grilles allow Emergency Egress while fully closed. Products covered under US Patents: 5,203,392-5,245,879-5,386,891-5,542,460 5,605,185-5,673,514-5,893,234. Additional patents are currently pending. 800-266-9392 9

Horizontal Coiling Service Doors Models HS100 and HSL150 Description: Designed to close openings in horizontal and inclined planes. Primarily motor operated, engineered for daily operation. Compact design. Use a single door rather than many Variety of finishes Side Coiling Doors and Grilles SC3000 Series Description: Side activated closures designed with curtains constructed of solid curtain slats, perforated curtain slats or of a security open type grille curtain. Opened and closed with a positive action system. Low head and side room requirements. Navigates small radius. Lightweight. Optional floor tracks. Horizontals are custom designed to meet the most stringent demands and requirements. Hurricane Service Doors Model H3000 Description: Designed for the largest of openings. Built of up to 14 gauge steel or stainless steel curtains. Individual curtain slat height is 6 and depth is 1 3/8. Hurricane Service Doors can be constructed up to 100' in width and over 100' in height. Hurricane Service Doors are by far the most durable coiling doors manufactured. They are available in designs that allow them to sustain extremely high wind loads and heavy impact from flying debris. 70 Foot wide Hurricane Door provides the necessary protection without limiting daily business operations Available Up To 100 Feet in Width Patent Pending 10

Coiling Security Grilles and Perforated Doors SG3000 Series Description: Vertical coiling units comprised of vertical links and horizontal rods available in motor, hand crank, hand chain and push up operation. Available in stainless steel, steel, aluminum. Variety of finishes. McKeon Door offers 8 standard grille patterns. Our units reduce head and side room requirements 30% - 40% compared to conventional coiling security grilles. Drives can be remote, reducing head room requirements by several inches. Available Up To 60 Feet in Width Coiling Counter Shutters CS3000 Series Description: Designed for both interior and exterior applications and for protection and security. Available up to 28 0 wide x 12 0 high. Interior and exterior applications. Available in push-up, manual hand crank or motor operation. Heavy Duty Design for maximum security Requires very little head room and side room Easy & smooth operation for everyday use Many finishes available Coiling Service Doors Model SD3000 Description: Service Doors are custom designed to accommodate any opening size. These doors are available in prime painted galvanized steel, aluminum, stainless steel or can be powder coat finished to any color requirement. Service Doors utilize less head and side room than other products such as swinging or sliding type doors. More security, highly durable - easy to repair and maintain. For exterior and interior use. Ideal where durability, frequent cycling, or severe weather exposure is an issue. Many finishes available. Available Up To 100 Feet in Width Coiling Insulated Service Doors Model IS3000 Description: Insulated with foamed-in-place polyurethane providing an R value of 6.25. Available in prime painted galvanized steel, aluminum, stainless steel or can be powder coat finished to any color requirement. Insulated Service Doors are ideal for energy conservation and protection against the elements. Insulated Service Doors are available with 16, 18, 20 and 22 gauge curtain front panels and 18, 20 and 22 gauge back panels. Available Up To 100 Feet in Width Patent Pending Patent Pending Patent Pending 08 33 00/MCK BuyLine 6566 800-266-9392 11

FIRE, SMOKE, SECURITY and DOOR SYSTEMS Fire and Smoke Rated Doors With Emergency Egress Vertical Coiling Fire Doors Vertical Acting Fire Doors Side Coiling Fire Doors Side Acting Fire Doors Accordion Folding Fire Doors Fire and Smoke Rated Doors Without Emergency Egress Horizontal Fire Shutters Side Coiling Fire Doors Overhead Coiling Fire Doors Insulated Fire Doors Acoustical Fire Doors Counter Fire Shutters Non-Fire Rated Service Doors and Grilles Self-Opening, Vertical Coiling Self-Opening, Side Coiling Side Coiling Doors and Grilles Insulated Service Doors Hurricane Doors Coiling Security Grilles Horizontal Coiling Service Doors Coiling Security Grilles w/ Egress Coiling Service Doors Coiling Counter Shutters Perforated Service Doors McKEON DOOR COMPANY NEW CORPORATE HEADQUARTERS 44 Sawgrass Drive Bellport, NY 11713 USA Toll-Free Tel: 800-266-9392 info@mckeondoor.com Additional information also available: AIA Continuing Education Provider Program, Architectural Design Manual, CD with CAD Product Details and Technical Specifications, CD with Product Demonstrations, Videos and more... Contents Copyright 2008 McKeon Door Company