Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

Similar documents
Steel-framed Walls. Insulation

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Timber Frame Walls Rethinking Construction

Multi-layer Insulation Blanket for Roofs

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

The Real Value of Space

Rockwool Cladding Roll

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

KINGSPAN INSULATION KINGSPAN KOOLTHERM K12 FRAMING BOARD INSULATION

The Kingspan Insulation Price List 1 st January 2013

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Rockwool Flexi Insulation Application Guide

Building Regulations for the Conservation of Fuel and Power

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Mold Preventing I nterior System

AND MEMBRANES ROOFING UNDERLAYS.

19 Examples of Wall Insulation

Composite Panel Firewall Systems

Basements. I n s u l a t i o n. Low Energy Low Carbon Buildings

TR31. I n s u l a t i o n. Low Energy Low Carbon Buildings

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

0331 Brick and block construction

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

- Version 2 Total R-value calculations for typical building applications

FIRE RATED GLAZING System Guide

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

I n s u l a t i o n. Eighth Issue July 2014 BREEAM 2011 PRODUCTS ACHIEVE? KOOLDUCT & THERMA TM. Low Energy Low Carbon Buildings

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Energy Company Obligation (ECO): Technical Monitoring Questions

Low Energy Low Carbon Buildings

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

PB301 July Lightweight Building Solutions. Bushfire Protection.

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

Manual lifting and handling

DENSO WATERPROOFING SYSTEMS

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Dubai Municipality Standard DMS 1: Part 5: 2004

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

EUROPEAN STANDARDS AND MARKINGS FOR HAND AND ARM PROTECTION

Module 3.7. Thermal bridging

EcoTouch Insulation with PureFiber Technology

Continuous Insulation Using Polyiso Wall Sheathing

GreenGuard Housewrap Installation Guide

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Providing protection in construction

Prefabricated building PVC vertical sliding window

High Capacity Hot Air Dryer

SIP (STRUCTURAL INSULATED PANEL)

HUNTON BITUMEN IMPREGNATED BOARDS HUNTON BITROC SHEATHING BOARD

Physically Crosslinked Foam Insulation

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?

Glidevale offers a complete range

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

Low VOC Performance Protection Systems

European Technical Approval ETA 13/0526

Understanding BS EN 771-3: Aggregate concrete masonry units

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

CREATING EFFECTIVE WATERPROOFING & DRAINAGE FOR INTERIOR WALLS. Using Oldroyd Xv clear, Xv20 and Xp on interior walls

Division 9. SignaFlor Pad and Pour Flooring System

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Including. Rubershield-Pro. Breather Membrane

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

SILASTIC 9161 RTV Silicone Elastomer

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

European Organisation for Technical Approvals

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS

Roofers Guide to Underslating Membranes

plumbing products guide

Installation Instructions

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

I n s u l a t i o n. Low Energy Low Carbon Buildings

Polymeric membrane for roof waterproofing

Stonewool Insulation for Thermal, Acoustic and Fire Safety Building Applications

Fire Barrier Duct Wrap 15A

HI-PERFORMANCE REFLECTIVE INSULATION. The most versatile insulation CONTRACTOR INFORMATION AND INSTALLATION GUIDE

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

Fiberglas, Exterior Wall Thermal Insulation

Installation Window Building In Details

Mineral fibreglass insulation

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Housing Fact Sheets. Insulation Check-Up

3 Single-Coated Foam Tapes

Universal systems for frameless doors

The Warm Edge for insulating glass

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

Transcription:

Insulation A4/8 PS055XV AW1=2002 Issue 3 Sept 2015 Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES 5x higher vapour transmission than previous generation Reduces the risk of condensation Helps achieve a 6-star house energy rating 3-in-1 insulation, vapour-permeable membrane and radiant barrier Wall cavities remain unfilled and accessible for services Fibre-free, non-allergenic, non-irritant Quick and easy to install Water-resistant and unaffected by moisture Strong, tough, durable Rodent and insect resistant Flammability Index 5 BCA and AS/NZS 4859.1 compliant Made in Australia

Double Brick Cavity Walls Typical Design Detail Face brickwork Permicav XV TM Spacer Biscuit TM (over wall tie) Cavity wall tie Permicav XV TM Face brickwork Internal brickwork Spacer Biscuit T M (over wall tie) Internal brickwork Cavity wall tie Hardwall plaster-finish Figure 2 Side elevation of Permicav XV TM in double brick cavity wall Installation Instructions 1. Lay outer leaf or brickwork with wall ties in place. Figure 1 Double brick cavity wall installation Thermal Performance Application Heat flow in Heat flow out Double brick cavity wall R T 1.8 R T 2.0 The R-values shown are Total R-values for the building element as required by the Energy Provisions of the Building Code of Australia. products are manufactured, tested and packaged in conformance with AS/NZS 4859.1. The contribution of the product Total R-values depends on installation and environmental conditions. Specification Guide The wall insulation fixed to the brickwork over the wall ties shall be Permicav XV TM fibre-free, thermo reflective insulation, comprising a cross-linked, closed-cell foam core sandwiched with an anti-glare foil facing on one side and a plain foil facing on the other side manufactured by Kingspan Insulation Pty Ltd, and shall be installed in accordance with the instructions issued by them. 2. Clip Spacer Biscuits TM onto every second wall tie, or as required to maintain a nominal 20 mm air space between the brick face and Permicav XV TM and push against the brickwork. 3. Roll out Permicav XV TM horizontally (antiglare facing installer) and offer up to the wall. 4. Cut a slit for each wall tie to penetrate the Kingspan AIR-CELL Permicav XV TM. 5. Push Permicav XV TM over the wall ties until it is against the Spacer Biscuits TM. 6. Allow a 50 mm overlap at joins with the upper layer overlapping on the outside of the lower, and tape with a 48 mm wide reinforced foil tape (please refer to brochure Kingspan Insulation Tape for further information). For detailed Installation Instructions please refer to the brochure Double Brick Cavity Walls. Scan to see the installation video 2

Brick Veneer Walls Typical Design Detail Timber stud Plasterboard lining Permicav XV TM Internal stud frame Permicav TM XV TM Face brickwork Plasterboard lining Timber framework Brick facing Figure 3 Brick veneer wall installation Thermal Performance Application Heat flow in Heat flow out Brick veneer wall R T 1.7 R T 1.9 The R-values shown are Total R-values for the building element as required by the Energy Provisions of the Building Code of Australia. products are manufactured, tested and packaged in conformance with AS/NZS 4859.1. The contribution of the product Total R-values depends on installation and environmental conditions. Specification Guide The wall insulation fixed to the outside of the stud frame shall be Permicav XV TM fibre-free, thermo reflective insulation, comprising a cross-linked, closed-cell foam core sandwiched with an anti-glare foil facing on one side and a plain foil facing on the other side manufactured by Kingspan Insulation Pty Ltd, and shall be installed in accordance with the instructions issued by them. Figure 4 Side elevation of Permicav XV TM in brick veneer wall Installation Instructions 1. Roll out Permicav XV TM horizontally and fix to outside of internal wall frame, working from the bottom up. 2. Allow 50 mm overlap between top and bottom layers and tape with 48 mm reinforced foil tape (please refer to brochure Kingspan Insulation Tape for further information). 3. Cut Permicav XV TM carefully around doors, windows and other openings, so that it neatly abuts to frames. 4. Penetrations for wall ties or services should be neatly cut to minimize gaps. For detailed Installation Instructions please refer to the brochure Brick Veneer Walls. Scan to see the installation video 3

Product Details Product Description Australian-made Permicav XV TM (Patent Pending 2014901279) is the next generation of vapour-permeable insulation. This evolution, specifically designed to reduce the risk of condensation in walls with cavities, has improved vapour transmission by five times compared to old technology. The micro perforations allow water vapour to permeate through while keeping moisture out and maintaining thermal resistance. Management Standards Standard BS / I.S. EN ISO 9001:2008 AS/NZS ISO 14001:2004 Product Specifications Management System Quality Management Evironmental Management Permicav XV TM is manufactured with a patented perforated closed-cell core sandwiched by highly reflective foil facings. Product Data Product Code PS055XV Product Thickness 5.5 mm Product R-Value R0.15 Roll Diameter 420 mm Roll Weight 7.7 kg Roll Size 1350 mm x 22.25 m (30 m 2 ) Reflectance Reflective Face 97% Anti-Glare Face 88% Emittance Reflective Face E0.03 Anti-Glare Face E0.12 Max. Span 2.4 m Characteristic Test Method / Standard Specification Flammability Index AS 1530.2 5 Material Thermal Resistance ASTM C518 0.15 m² K/W Emittance ASTM E408 Reflective Face: E0.03 Anti-Glare Face: E0.12 Duty Rating (Burst Force) AS 3706.4 1.0 kn - equivalent to Extra Heavy Duty Vapour Barrier ASTM E96 Low Resistance Shrinkage AS/NZS 4201.3 < 0.5% Dry Delamination AS/NZS 4201.1 Pass Wet Delamination AS/NZS 4201.2 Pass Water Barrier AS/NZS 4201.4 High Resistance Water Absorbency AS/NZS 4201.6 High Corrosion Resistance AS/NZS 4859.1 Appendix I Pass Environmental Data Figure 5 Vapour-permeable perforations in Kingspan AIR-CELL Permicav XV TM - 5x more efficient than its predecessor Aspect Characteristic Recycled Content Approx 3% Recyclability Waste not recyclable Roll width to suit most applications to minimise on site waste Re-usability Re-usable if removed with care (long term of service expected) Water Use No water used in Kingspan Insulation s manufacturing process Processing Greenhouse Gas Emissions Ozone Depleting Substances Packaging Transport No Greenhouse Gas Emissions in Kingspan Insulation s manufacturing process None present in the finished product or in Kingspan Insulation s manufacturing process Contains approx 10% recycled product Packaging 100% recyclable Distribution policy incorporating the principals of ISO 14001 Embodied Energy 43 MJ/m 2 approximately 4

Condensation As thermal performance requirements for the building fabric continue to rise, condensation is becoming an increasingly important design consideration for healthy buildings. Ineffective management of moisture and vapours can potentially lead to indoor health issues and structural defects which require expensive remedial works. New improved Permicav XV TM reduces the risk of interstitial condensation by allowing vapour to permeate through tiny perforations even better. Figure 6 illustrates the high vapour permeability of Kingspan AIR-CELL Permicav XV TM compared to its predecessor and other common building materials. Water Vapour Transmission (g/hr.m 2 ) 1.60 1.40 1.20 1.00 0.80 0.60 0.40 0.20 0.00 Non-vapourpermeable reflective insulation Brick AIR-CELL Permicav AIR-CELL Permicav XV TM Figure 6 Water vapour transmission comparison. Our Technical Services team can also offer customised condensation risk advice for your projects, so you always get the right advice for the right application. N.B. Appropriate products should always be used for the appropriate climates, constructions and conditions. Depending on some variables, a vapour barrier may be preferable. Please contact us or consult your architect for more detailed advice. 5

General Requirements 1. Fit neatly around doors, windows, and any penetrations, and tape if necessary to prevent air leakage. 2. When taping a plastic squeegee or blade must be used to apply appropriate pressure to the tape. Surfaces must be dry and free from dust, oil or grease prior to taping (please refer to brochure Kingspan Insulation Tape for further information). 3. Leave minimum 50 mm clearance around heat producing flues or light fittings (refer to light fitting manufacturer). The instructions in this document are guidelines only and should be interpreted with consideration for the specific building design. The installation of should be in conformance with the applicable clauses from AS 3999 and AS/NZS 4200.2 unless otherwise specified. can be damaged by intense heat above 105 C and contact with sparks and flame from blow torches, welders, cutting tools, etc. must be avoided. The installer must make due provision for safety when installing in any application. Safety Information Non-hazardous/non-toxic. No personal protective equipment required. UV protective sunglasses and screen should be used when installing in direct sunlight. Ensure at least 50 mm clearance from hot flues and light fittings (check for safe distance with lighting supplier). Foil facings are conductive to electricity - avoid contact with un-insulated electrical cables and fittings. Handling and Storage insulation products must be transported and stored in its protective packaging and kept clean and dry. Standing rolls on end reduces risk of damage should moisture be present in the packaging. Surfaces must be kept free of contaminants such as dust and grease, and must not be stored with foil surfaces in contact with alkaline materials i.e. wet cement, lime, etc. 6

7

Contact Details General Enquiries Tel: 1300 247 235 Email: info@kingspaninsulation.com.au Kingspan Insulation Pty. Ltd. reserves the right to amend product specifications without prior notice. The information, technical details and fixing instructions etc. included in this literature are given in good faith and apply to uses described. Recommendations for use should be verified as to the suitability and compliance with actual requirements, specifications and any applicable laws and regulations. For other applications or conditions of use, Kingspan Insulation offers a Technical Advisory Service the advice of which should be sought for uses of Kingspan Insulation products that are not specifically described herein. Please check that your copy of the literature is current by contacting us or visiting www.kingspaninsulation.com.au Kingspan Insulation Pty Ltd Tel: 1300 247 235 Email: info@kingspaninsulation.com.au www.kingspaninsulation.com.au Kingspan, Kooltherm, Air-Cell, the zo Device and the Lion Device are Registered Trademarks of the Kingspan Group plc in Australia and other countries. All rights reserved. Kingspan Insulation Pty Ltd