ACE969 Multi-Protocol Communication Interface Install Sheet

Similar documents
Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

NC-12 Modbus Application

HARTING econ 3000 Introduction and features

Modular I/O System Analog and Digital Interface Modules

PowerLogic Sub Meter Display (SMD and SMDOPN)

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

HARTING mcon 1000 Introduction and features

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

PCS0100en Persy Control Services B.V. Netherlands

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

RLH 2 Wire Digital Phone Fiber Link Card System

Square D Clipsal C-Bus Network Analyzer

OPT SERIAL TO FIBER OPTIC CONVERTER

FlexPoint T1/E1 Copper to Fiber Line Driver

INSTALLATION INSTRUCTIONS

Perle 10/100 Ethernet Media Converters

Optimux-134, Optimux-125

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

TrueAlarm Fire Alarm Systems

Auxiliary equipment for communication with the EuroProt protective devices

Optimux-134, Optimux-125

MCR1900 Media Converter 19-Slot Chassis

2-Pair HDSL1 Adtran Fiber Optic Link System

Single Port Gigabit Ethernet Media Converter Board (P/N xxx) User s Manual And Troubleshooting Guide

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

F2400 FOM II Series Fiber Optic Modem Technical Manual

10/100/1000 Base-T to Gigabit Fiber Media Converter

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Square D Clipsal Two-Channel DIN-Rail DALI Gateway

ST Series POWER SUPPLIES USER INSTRUCTIONS

ELCOMPONENT LTD. User Manual

Application/Connection Examples

Optimux-34, Optimux-25

Perle 10/100/1000 Ethernet Media Converter Module

HARTING mcon 3000 Introduction and features

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

EMBEDDED ACCESS CONTROL Hardware Installation Guide

HSG Engineering Tech Bulletin

ABB RTU560A Series CMU & Modules

38 Series - Relay interface modules A

WD-AMX Water Detection Controllers

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

BACnet Automation Interface Module (Network Version)

Rack mounted telephone- and leased line modem for industrial applications

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

DeltaV SISnet Repeater

IO-RM3 3-Stage Relay Module

Perle Fast Fiber to Fiber. Media Converters

Gigabit Switching Ethernet Media Converters - Product User Guide

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Terminal and Dimension

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Installation and start-up guide NETA-21 remote monitoring tool

HM-W536 Install Guide

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

IntesisBox Modbus Server SAMSUNG Air Conditioners

Provides one channel for Ethernet over existing

MasterINTERFACE 39 Series - Relay interface modules

Perle Gigabit Fiber to Fiber Media Converters

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

Allen-Bradley HP AC Line Filter Kit

User Manual Revision English

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Using installed Fieldbus Wiring to carry Ethernet Communications

Cable Specifications. T3 Trunk Cabling APPENDIX

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

VOICE RECORDING SYSTEM ISDN PRI / BRI

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

MICROSENS. 45x45 Installation Switch for FTTO applications. Introduction. Characteristics

LIEBERT VNSA Installation Sheet

ADM1TE 5/30A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Operating Instructions

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Provides one channel for Ethernet over existing

Intersection Preassembled 19-inch Rack

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

HARAX circular connector

HMI display Installation Guide

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

IntesisBox Modbus Server Fidelio IP

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Multi Media Cable Tester TM-901N/TM-902/TM-903

Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual

CABLE SPECIFICATION CAN CAB RJ45-SUBD9

Transcription:

Instruction Bulletin 63230-216-235A1 LaVergne, TN, USA ACE969 Multi-Protocol Communication Interface Install Sheet Retain for future use. Function PE50470 The ACE969 multi-protocol communication interfaces function with Sepam Series 20, 40, or 80. They have two communication ports to connect a Sepam to two independent communication networks: The S-LAN (Supervisory Local Area Network) port to connect Sepam to a supervision network using one of the three following protocols: PE50471 ACE969TP Communication Interface ACE969FO Communication Interface IEC 60870-5-103 DNP3 RTU Modbus The communication protocol is selected when setting Sepam parameters. The E-LAN (engineering local area network) port, reserved for Sepam remote parameter setting and operation using the SFT2841 software There are two versions of the ACE969 interfaces. Each has different S-LAN ports: ACE969TP (Twisted Pair) is for connecting to an S-LAN network using a two wire RS485 connection ACE969FO (Fiber Optic) is for connecting to an S-LAN network using a fiberoptic connection (star or ring) The E-LAN port is always a two-wire RS485 connection. Characteristics Dimensions Install1 DE80043 in. (mm) 3.54 (90) Sepam Series 20 Sepam Series 40 Sepam Series 80 V0526 V3.00 Base V3.00 Appli V3.00 5.67 (144) 2.05 (52) 1

ACE969 Multi-Protocol Communication Interface 63230-216-235A1 ACE969 Module Technical Characteristics Weight 0.628 lb (0.285 kg) Assembly On symmetrical DIN rail Operating Temperature 13 F to +158 F ( 25 C to +70 C) Environmental Characteristics Same characteristics as Sepam base units Power Supply Voltage 24 to 250 VDC 110 to 240 VAC Range 20%/+10% 20%/+10% Maximum Burden 2 W 3 VA Inrush Current < 10 A 100 μs Acceptable Ripple Current 12% Acceptable momentary outages 20 ms Two-Wire RS485 Communication Ports Electrical Interface Standard EIA 2-wire RS485 differential Distributed power supply External, 12 V DC or 24 V DC ±10% Power burden 16 ma in receiving mode 40 ma in sending mode Maximum number of Sepam units 25 Maximum Length of 2-Wire RS485 Network Number of Sepam Units With Distributed Power Supply 12 VDC 24 VDC 5 1000 ft (320 m) 3300 ft (1000 m) 10 590 ft (180 m) 2500 ft (750 m) 20 430 ft (130 m) 1500 ft (450 m) 25 410 ft (125 m) 1200 ft (375 m) Fiber Optic Communication Port Fiber Optic Interface Fiber Type Graded-index multimode silica Wavelength 820 nm (invisible infra-red) Type of Connector ST (BFOC bayonet fiber optic connector) Maximum Length of Fiber Optic Network Fiber Diameter (μm) Numerical Aperture (NA) Maximum length is calculated with: Attenuation (dbm/km) Min. Optical Pwr Available (dbm) Maximum Fiber Length 50/125 0.2 2.7 5.6 2300 ft (700 m) 62.5/125 0.275 3.2 9.4 5900 ft (1800 m) 100/140 0.3 4 14.9 9200 ft (2800 m) 200 (HCS) 0.37 6 19.2 8500 ft (2600 m) Minimum optical power available Maximum fiber attenuation Losses in two ST connectors: 0.6 dbm Optical power margin: 3 dbm (according to IEC 60870 standard) Example for a 62.5/125 μm fiber Lmax = (9.4-3 - 0.6)/3.2 = 1.8 km (1.12 mi) 2 2007 Schneider Electric. All Rights Reserved.

63230-216-235A1 ACE969 Multi-Protocol Communication Interface Component Descriptions ACE969 Communication Interfaces Install2 Ctrl Power RS485 RS485 Ctrl Power RS485 1. Grounding terminal using supplied braid 2. Power-supply terminal block 3. RJ45 socket to connect the interface to the base unit with a CCA612 cable 4. Green LED: ACE969 energized 5. Red LED: ACE969 interface status LED off = ACE969 set up and communication operational LED flashing = ACE969 not set up or setup incorrect LED remains on = ACE969 failed DE51855 DE51856 ACE969FO 3 4 5 6 Rx Tx on Rx Tx V+ V- A B S-LAN E-LAN 6. Service connector: reserved for software upgrades ACE969TP 2 1 ACE969FO 9 7 7. E-LAN 2-wire RS485 communication port (ACE969TP and ACE969FO) 8. S-LAN 2-wire RS485 communication port (ACE969TP) 9. S-LAN fiber-optic communication port (ACE969FO) 2007 Schneider Electric. All Rights Reserved. 3

ACE969 Multi-Protocol Communication Interface 63230-216-235A1 RS485 Connection Install5 Install3a RS485 (S-LAN) RS485 (E-LAN) Shield Shield Two-Wire RS485 Communication Ports 1. Grounding terminal using supplied braid Two- Wire RS485 Network Terminal Block: Two black terminals connect the two-wire RS485 twisted pair Two green terminals connect a twisted pair for distributed power supply DE51863 serv Rx Tx on Rx Tx S-LAN E-LAN V+ V A B V+ V A B DE51864 Rx 2. LEDs: Flashing Tx LED: Sepam sending Flashing Rx LED: Sepam receiving 3. Clamps and recovery of shielding for two network cables, incoming and outgoing (inner diameter of clamps = 0.24 in or 6 mm) NOTE: Clamps are also common ground. 4. Fixing stud for network cable ties 5. Jumper for 2-wire RS485 network line-end impedance matching with the load resistor ( = 150 Ω), is set to: S-LAN Port (ACE969TP) E-LAN Port (ACE969TP or ACE969FO), if the module is not at one end of the network (default position). The "X" over the "" indicates that the resistor is not in use, if the module is at one end of the network. This means the resistor is jumpered in 4 2007 Schneider Electric. All Rights Reserved.

63230-216-235A1 ACE969 Multi-Protocol Communication Interface Fiber-Optic Communication Port DE52078a ACE969FO Chassis Common Ground Common Ground Not Connected Shield (Typical) AC/DC + AC/DC Control Power Network Port Power 12-24 VDC V + V A/A B/B V + V A/A B/B 1. LEDs: Flashing Tx LED: Sepam sending Flashing Rx LED: Sepam receiving 2. Rx, female ST type connector (Sepam receiving) 3. Tx, female ST type connector (Sepam sending) DE51865 Rx Tx on Rx Tx S-LAN ser E-LAN V+ V A B Tx Rx S-LAN Port (ACE969FO) Install6 AC/DC + AC/DC + AC/DC AC/DC 2007 Schneider Electric. All Rights Reserved. 5

ACE969 Multi-Protocol Communication Interface 63230-216-235A1 Connecting the ACE969 Power Supply and Sepam The ACE969 interface connects to C on the Sepam base unit using a CCA612 cable (length = 9.8 ft or 3 m, with green RJ45 fittings) 24 to 250 V DC or 110 to 230 V AC operates the ACE969 interface. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Only qualified electrical workers should install this equipment. Such work should be performed only after reading this entire set of instructions. NEVER work alone. Before performing visual inspections, tests, or maintenance on this equipment, disconnect all sources of electric power. Assume that all circuits are live until they have been completely de-energized, tested, and tagged. Pay particular attention to the design of the power system. Consider all sources of power, including the possibility of backfeeding. Always use a properly rated voltage sensing device to confirm that all power is off. Screw tight all terminals, even those not in use. Failure to follow these instructions will result in death or serious injury. DE52166 Terminals Type Wiring e1-e2 - supply Screw terminals Wiring with no fittings: One wire with maximum cross-section 0.2 to 2.5 mm 2 ( AWG 24-12) or two wires with maximum cross-section 0.2 to 1 mm ( AWG 24-18) Stripped length: 0.31 to 0.39 in (8 to 10 mm) Wiring with fittings: recommended wiring with Telemecanique fitting: - DZ5CE015D for 1 wire 1.5 mm² (AWG 16) - DZ5CE025D for 1 wire 2.5 mm² (AWG 12) - AZ5DE010D for 2 wires 1 mm² (AWG 18) V DC/V AC Ctrl Pwr Wire length: 0.32 in (8.2 mm) Stripped length: 0.31 in (8 mm) DE51845 DE51962 Protective ground Functional gnd (Common Gnd Screw terminal 0.16 in (4 mm) ring lug Control Power ground conductor 1 green/yellow wire, max. length 9.8 ft (3 m) and max. cross-section 2.5 mm² (AWG 12) Grounding braid, supplied for connection to cubicle grounding CAUTION ESD SENSITIVE COMPONENTS Before touching the Memory Cartridge you must ground yourself and discharge any static charge Ground yourself every time before touching the memory cartridge Failure to follow this instruction can result in equipment damage. 6 2007 Schneider Electric. All Rights Reserved.

63230-216-235A1 ACE969 Multi-Protocol Communication Interface Connections DE52078 Not Connected Shield (Typical) Control Power AC/DC + AC/DC ACE969TP Common Ground Chassis Common Ground Two-Wire RS485 Communication Ports (S-LAN or E-LAN) 1. Connect the RS485 twisted pair (S-LAN or E-LAN) to black terminals A and B. 2. Connect the twisted pair for the distributed power supply to green terminals V+ and V-. 3. The interfaces are fitted with clamps to hold the network cable in place and to recover shielding at the incoming and outgoing points of the network cable: The network cable must be stripped One cable shielding must be around and in contact with the clamp (see note below) 4. An internal connection links all cable clamps to the ACE969 Interface grounding terminals (protective and functional grounding), with the shielding of the RS485 cables is grounded as well. 5. On the ACE969TP interface, the cable clamps for the S-LAN and E-LAN RS485 networks are grounded. NOTE: The cable shielding shown at left should only be done at one point, preferably at one end of the daisy chain. Fiber Optic Communication Port (S-LAN) DE52165 Ring Connection Optic Wye Connection CAUTION Optic Wye HAZARD OF BLINDING Never look directly into the fiber optic Failure to follow this instruction can cause serious injury. The fiber optic connection can be made point-to-point to an optic star system, or in a ring system (active echo). The transmitting and receiving fiber optic fibers must have male ST type connectors. The fiber optics screw-lock to Rx and Tx connectors. Install7 Fiber Optic (FO) 2007 Schneider Electric. All Rights Reserved. 7

ACE969 Multi-Protocol Communication Interface 63230-216-235A1 Instruction Bulletin Notes Schneider Electric USA 295 Tech Park Drive, Suite 100 LaVergne, TN 37086, USA 1-888-SquareD (1-888-778-2733) www.us.squared.com Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. 2007 Schneider Electric. All Rights Reserved.