Air Release and Vacuum Break Valves

Similar documents
Air/Vacuum Valves. Removal of Air from Pipelines. Allow the Entry of Air into Pipelines. Application:

Theory, Application, and Sizing of Air Valves

Air Eliminators and Combination Air Eliminators Strainers

APCO SLOW CLOSING AIR/VACUUM VALVES

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

AUTOMATIC AIR VENT VALVES MANUAL VALVES FOR DISCHARGING AIR FROM RADIATORS

BLADDER SURGE CONTROL SYSTEM

CATALOGUE INDEX PAGE CONTENT OPERATION -SERIES RBX 1-2 RECOMMENDED INSTALLATION ARRANGEMENTS -SERIES RBX 3

pressure inside the valve just before the final release of air. in pipeline systems resulting from 2p 1 p a m C D A o

C. starting positive displacement pumps with the discharge valve closed.

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

AIR RELEASE AND VACUUM BREAK VALVES SERIES RBX ANTI-SHOCK. The Unique defence against pipe bursts and pipeline system damage!

Water hammering in fire fighting installation

TECHNICAL DATA. Dry 122a. November 12, 2013

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Unit 24: Applications of Pneumatics and Hydraulics

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Minor losses include head losses through/past hydrants, couplers, valves,

Pressure drop in pipes...

Anti-Cavitation Trim. Eliminates cavitation damage Reduces noise Preserves valve and surrounding pipe systems. singervalve.com

Unit 24: Applications of Pneumatics and Hydraulics

Operation & Maintenance Manual

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

HS-901(A) BASIC STEAM HEATING SYSTEMS

Steam System Best Practices Condensate System Piping

PRESSURE REDUCING CONTROL VALVE

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

MFP14, MFP14S and MFP14SS Automatic Pumps

Thermostatic valve Type AVTA

Steam Jet Vacuum Pumps

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

In-Line Air Separators

08.08 Vic-Check Valves

METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS

Operators manual Basic water heater

BERMAD Waterworks. Surge Anticipating Control Valve. 700 Series. Model 735-M. Features and Benefits. Major Additional Features

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

VAL-MATIC VALVE AND MANUFACTURING CORP. 905 RIVERSIDE DRIVE, ELMHURST, IL TEL. (630) FAX.

Heating Water by Direct Steam Injection

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

ALMATEC Series CX CX 10 CX 130

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Draining and filling cooling system

PC1130 Electric Air Compressor

BERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

P U L S A T I O N D A M P E N E R S

REGULATING VALVE APPLICATIONS

BERMAD Fire Protection

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

A basic introduction to steam

Basic Hydraulics and Pneumatics

SANITARY SEWER SPECIFICATIONS

PC1131 Electric Air Compressor

DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST

Float and Thermostatic Traps Series H, C and X

Radial piston pumps type R and RG

Class A Foam Mixing and Application Equipment

Blowdown vessels Meeting the requirements of HSE PM60

Mechanical Seal Piping Plans

Select the Right Relief Valve - Part 1 Saeid Rahimi

Domino VGS. Domino. Vertical Gravity Separator VGS. Oil Out. Clean Water Outlet. Oily Water In. Sludge Outlet. Everything Water PTY LTD

VAD. Variable Area Desuperheaters

Green Thread Product Data

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

CHAPTER 3: FORCES AND PRESSURE

Hydraulic control unit series

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

4" SUBMERSIBLE PUMPS

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

AIR LINE VALVES AND GAUGES

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

BOWIE PUMPS OPERATION - MAINTENANCE

Signature and ISX CM870 Fuel System

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

How To Clean Water From An Ammonia Refrigeration System

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

FLUID FLOW Introduction General Description

PUMPS TYPE OF PUMP PRESSURE/FLOW RATING CHARACTERISTICS. Centrifugal Low Pressure/High Flow Flow changes when

OUTCOME 1 STATIC FLUID SYSTEMS TUTORIAL 1 - HYDROSTATICS

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

BERMAD Fire Protection

Transcription:

Air Release and Vacuum Break Valves Scan for more information Technical Guide W4.28 Increases Overall Pipeline Efficiency Protection of pipelines from damage caused by air. 2016 PRESSURE SYSTEMS W4.28 DAV-P Air Release Vacuum Break Valves Applications Air release Vacuum break Product Attributes Water Waste water Pump station Reticulation lines Pipe bridges Quality ISO 9001:2008 Quality Management Standard The go to organisation for civil and rural water product solutions

The presence of trapped air in a pressurised pipeline can have serious effects on system operation and efficiency. As air pockets accumulate at high points, they reduce the effective cross-section of the pipeline in their location, decreasing the water flow, increasing energy consumption required to pump the water through, thus reducing the overall system efficiency. Pipeline without Air Release Valves Increases head loss Decreases flow rate Increases energy consumption Increases surge conditions Large amount of air trapped at system high points W4.28 DAV-P Air Release Vacuum Break Valves PRESSURE SYSTEMS PG 2 When a system is being drained there is a necessity to admit atmospheric air into the pipeline in order to occupy the volume of drained water so to prevent dangerous sub-atmospheric pressure in the pipeline that may cause complete collapse of pipe-sections. Pipeline without Air Vacuum Valve Contaminants can be sucked into the system Pipes can collapse Vapor pockets can form (as the water boils at such low pressure) Collapse or damage pump impellers Vertical turbine pumps and well pumps lift water from a tank or well into a pipeline. After each pump stoppage, the pump column refills with air because the suction water level is below the pump discharge pipe. If the pump is started without an air valve, the air in the pump column would be pressurised and forced through the check valve into the pipeline, causing surges in the pipe column and the entry of large volumes of air into the pipeline. Fig. 1 Pipeline without Air Release Valves Sub atmospheric pressurise created due to pump shutdown or surges conditions Fig. 2 Pipeline without Kinetic Vacuum Valve Vertical pump discharge without Air Valve Surges in pipe column Entry of large volumes of air into the system Potential vacuum The pump column refills with air after each pump stop page Fig. 3 Vertical pump discharge without Air Valve

AUTOMATIC AIR VALVE AIR VACUUM VALVE COMBINATION AIR VALVE Fig. 4 The types and functions of Air-Valves Automatic Air Release Valves Release small pockets of accumulated air while the pipeline operates under pressure ( Automatic air-release function) Air / vacuum valve Exhaust large quantities of air from the pipeline when it is filled with water, at low pipeline pressure ( Kinetic airrelease function) Admit large quantities of air into the pipe when it is drained or when the internal pressure drops below atmospheric pressure such as in transient conditions ( Kinetic anti-vacuum function) Combination Air Valves A valve that perform the functions of both the Kinetic, exhaust/admit large quantities of air from the pipeline at low pressure, and Automatic, release small pockets of air from the pipeline under pressure. There are three primary sources of the presence of air in a pipeline At startup during filling, the pipeline contains air which must be exhausted. As the pipeline is filled, much of the air will be pushed downstream and released from the system. A large amount of air, however, will become trapped at system high points. Water at normal pressure and temperature can contain approximately 2% (by volume) of dissolved air. This dissolved air will come out of solution with a rise in temperature or a drop in pressure. The column of moving water is being subjected to varying pressures and temperatures, due to the terrain slopes, variations in flow velocity caused by changing pipe diameters, partiallyopen valves, etc. and the dissolved air may be freed from the water mass, accumulating as bubbles, eventually as large pockets of air in the local peaks. Air may be drawn into the pipeline at start-up of wellpumps, by the pump-vortex suction and through leaking joints at zones above the hydraulic gradients (negativepressure points). Air can also be admitted into the system by air valves under vacuum conditions. Air Valve locations along a pipeline 1. High points (relative to hydraulic gradient line). 2. Decrease in an upward slope. 3. Increase in a downward slope. 4. On uniform, long pipe sections: horizontal run, long descents, and long ascents. Air valves should also be located at even spaces of few hundreds of meters (500 to 1000), as determined by collapse-potential of the pipeline under negative pressure. 5. When the flow velocity is very low, air pockets may be accumulated in each local peak, even in small ones, and in steep downhill slopes. It is recommended to eliminate these restrictions by installing air release valves. 6. On the discharge side of deep-well pumps and vertical turbine pumps. 7. Both sides of canal and bridge crossings. 8. Both sides of check-valves, isolating valves and any device that may be closed in the water system, where air may be accumulated on one side while vacuum may be created on the other side. 9. Downstream of a pressure reducing device or temperature raising elements. 10. At any point where the air may accumulate due to local pressure change. 11. At any point where sub-atmospheric conditions may occur during normal or transient conditions. W4.28 DAV-P Air Release Vacuum Break Valves PRESSURE SYSTEMS PG 3

Fig. 5 W4.28 DAV-P Air Release Vacuum Break Valves PRESSURE SYSTEMS PG 4 Fig. 6 Discharge side of pumps Fig. 7 Increase downward slope Fig. 8 Discharge side of vertical turbine pumps

Fig. 9 Downstream of a pressure reducing device or temperature raising elements Fig. 10 Both sides of check-valves, isolating valves and any device that may be closed Fig. 11 Decrease in an upward slope / Increase in a downward slope Sizing principles The air volumetric-flow through the air valve is equal to the flow rate of the water filling or emptying the system: For each volume of water entering the pipeline, the same volume of air must me expelled and similarly, for each volume of water drained from the system, the same volume of air should be admitted into the line. Note: Air is a compressible media, so its density and volume vary with the pressure. The term volumetric flow noted above, refers to that of the air inside the pipeline and is smaller than the calculated standard (atmospheric pressure) air flow when the system is being charged with water and bigger than the standard flow when the system is being drained. The tables and charts presented in this catalogue present the standard air flow under atmospheric pressure. The air flow velocity in the valve depends on three factors: Rate of water flow, at the valve site Orifice diameter of the valve Geometry of the specific valve The air flow-velocity through the valve can reach very high values, due to its low density. It is limited only when the velocity reaches the sonic speed, which is practically impossible for the Kinetic valve type, but is the normal situation in the case of the Automatic valve type. Fig. 12 On uniform, long pipe sections: horizontal run, long descents, and long ascents When the system s internal pressure reaches 0.89 barg, the volumetric air-flow through the orifice becomes constant (critical, sonic-velocity). Increase of the pressure will not result in increased mass-flow, though standvard air-flow will continue to increase due to the increased pressure ratio between the line pressure and the atmospheric pressure. As a rule of thumb, the initial design value for air valves is such that will allow maximal ΔH of 0.1 barg across the valve. i.e. pipeline pressure that does not exceed 0.1 bar gauge-pressure while the pipe is filled, or -0.1 barg when it is drained. However, each system must be inspected to its specific conditions, which the main one is the risk of collapse under sub-atmospheric pressures. Too small orifice results in high air velocity that may cause: 1. Premature closure, before the water reaches the valve. 2. A mechanical slam of the float to its seating area when the water has reached the valve, local water-hammer and possible breakage in the valve. 3. Insufficient air flow into a drained system that may cause too low sub-atmospheric pressure, which in turn may cause ingress of contaminants into the system or even complete pipe-collapse. W4.28 DAV-P Air Release Vacuum Break Valves PRESSURE SYSTEMS PG 5

DAV-P-A Pipe is full of water Dissolved air is accumulated in the valve, released when the float drops down Pipe is aerated W4.28 DAV-P Air Release Vacuum Break Valves PRESSURE SYSTEMS PG 6 Fig. 13 The valve is designed for an efficient release of entrapped air from the pipeline, while the network is at normal working pressure. Due to the relatively large orifice, compare to other Automatic valves in the market, it can also release the air through initial filling of a small-diameter pipe, or admit air into it while it is drained. Properties An automatic air valve, that enables the release of dissolved air that accumulate in the pipeline. The valve will release the air at normal operation pressures of the pipeline. The float is made of naturally-buoyant material (specific weight < 1). The float activates a sealing stripe, that closes the outlet when the water will fill the valve body. On accumulation of air in the valve, loss of buoyancy causes the float to drop and to pull the strip, thus opening of the air outlet. The Hydraulic sealing of the orifice will provides a driptight closure at a pressure of 2mwc (3psi). Operation Releasing entrained air from the pipeline. Small quantities of diluted air accumulate in high peaks of the pipeline and in the peak of the valve. The pressurised air expels the water. The descending water level moves the main float with it. At a certain position the main float pulls down the small seal, that partially opens the nozzle. The pressurised air can escape, the water level rises and the nozzle re-closes. Technical Specications Operating pressure of 0.2 to 16 bars. 1/2, 3/4, 1 BSP or NPT threaded base - as per the customer s choice. Air flow, even at a critical velocity created by pipeline pressure of 0.9 bar, will not cause premature closure of the valve. Structure materials: Cover: GRP (UV resistant) Base: GRP / Brass Internal parts: corrosion resistant, reinforced plastic materials and synthetic rubber. The valve allows the discharge of 28m3/h of air at pipe pressure of 1.0 bar, when fully-open.

Table 1 Valve 12 mm / 1/2 18 mm / 3/4 25 mm / 1 Dimension SI US SI US SI US H Height 147 mm 53/4" 147 mm 53/4" 147 mm 53/4" W Width 86 mm 31/3" 86 mm 31/3" 86 mm 31/3" D Thread 1/2" BSP 1/2" NPT 3/4" BSP 3/4" NPT 1" BSP 1" NPT A Nozzle Area 12.85 mm2 0.02 in2 12.85 mm2 0.02 in2 12.85 mm2 0.02 in2 L Total Width 110 mm 41/3" 110 mm 41/3" 110 mm 41/3" E Drainage Diameter 1/4" BSP 1/4" BSP 1/4" BSP 1/4" BSP 1/4" BSP 1/4" BSP Weight 40 g 0.64 lbs. 40 g 0.64 lbs. 40 g 0.64 lbs. Table 2 Table 3 Table 4 Part Description Material 1 Base Glass Reinforced Nylon, Optional: Brass 2 Body Glass Reinforced Nylon 3 Float Foamed Polypropylene 4 Seal EPDM Rubber 5 O ring NBR 6 Drainage Elbow Polypropylene W4.28 DAV-P Air Release Vacuum Break Valves PRESSURE SYSTEMS PG 7 Fig. 14

DAV-P-K Pipe is full of water Pipe is aerated W4.28 DAV-P Air Release Vacuum Break Valves PRESSURE SYSTEMS PG 8 Fig. 15 This valve has been designed for efficient discharge and intake of air in water transport systems, filtering systems, containers, and other places where confined air could impair the system s operation. The valve is appropriate for Expelling the air at high flow velocity during the initial filling of the system. Introducing large quantities of air when the pipe drains, maintaining atmospheric pressures in the pipe and preventing collapse and cavitation damage to the conduits. Properties Leak-proof sealing at all conditions, including low system pressure. The aerodynamic design of the float provides air flow at a very high velocity. The float does not close before the water has reached the valve. Threaded outlet elbow allows various possibilities of drain connection. The valve design contains a very limited number of parts, allowing easy dismantling for maintenance. Technical Specications Operating pressure of 0.2 to 16 bars 1, 2 BSP or NPT threaded base - as per the customer s choice Air flow, even at a critical velocity created by pipeline pressure of 0.9 bar, will not cause premature closure of the valve Structure materials: Body: GRP (UV resistant) Internal parts: corrosion resistant plastic materials and synthetic rubber The valve allows the discharge of 700m3/h of air at pipe pressure of 0.5 bar Operation The DAV-P-K valve has two modes of operation: Discharge of large quantities of air at a high flow velocity when the conduit is being filled. When the water arrives to the valve, the float rises up and closes the outlet. Introduction of air into the pipeline when the internal pressure is subatmospheric. The pressure difference forces the float to drop to opened position, allowing large volumes of air to flow into the pipe.

Table 5 Valve 12 mm / 1/2 18 mm / 3/4 25 mm / 1 50 mm / 2 H Height 183 mm 71/4" 183 mm 71/4" 183 mm 71/4" 249 mm 97/8" W Width 86 mm 31/3" 86 mm 31/3" 86 mm 31/3" 110 mm 41/3" D Thread 1/2" BSP 1/2" NPT 3/4" BSP 3/4" NPT 1" BSP 1" NPT 2" BSP 2" NPT A Nozzle Area 12.85 mm 2 0.02 in 2 12.85 mm 2 0.02 in 2 12.85 mm 2 0.02 in 2 12.85 mm 2 0.02 in 2 K Kinetic Nozzle Area 314 mm 2 0.49 in 2 314 mm 2 0.49 in 2 314 mm 2 0.49 in 2 908 mm 2 1.41 in 2 L Total Width 134 mm 51/4" 134 mm 51/4" 134 mm 51/4" 187 mm 73/8" E Drainage Diameter 3/4" BSP 3/4" BSP 3/4" BSP 3/4" BSP 3/4" BSP 3/4" BSP 11/2" BSP 11/2" BSP Weight 470 g 1.04 lbs. 470 g 1.04 lbs. 470 g 1.04 lbs. 1052 g 2.32 lbs. Table 6 Table 7 Table 8 Table 9 Part Description Material 1 Body Glass Reinforced Nylon Optional: Brass 2 Bonnet Glass Reinforced Nylon 3 Float Foamed Polypropylene 4 Slider Glass Reinforced Nylon 5 Automatic Seal EPDM Rubber 6 Kinetic Seal EPDM Rubber 7 O ring NBR 8 Drainage Elbow Polypropylene W4.28 DAV-P Air Release Vacuum Break Valves PRESSURE SYSTEMS PG 9 Fig. 16

DAV-P-KA Pipe is full of water Dissolved air is accumulated in the valve, released when the float drops down Pipe is aerated W4.28 DAV-P Air Release Vacuum Break Valves PRESSURE SYSTEMS PG 10 Fig. 17 This valve has been designed for efficient discharge and intake of air in water transport systems, filtering systems, containers, and other places where confined air could impair the system s operation. The valve is appropriate for Expelling the air at high flow velocity during the initial filling of the systems. Introducing large quantities of air when the pipe drains, maintaining atmospheric pressures in the pipe and preventing collapse and cavitation damage to the conduits. Relieving the entrained air from the water, while the network is pressurised. Properties Leak-proof sealing at all conditions, including low system pressure. The aerodynamic design of the float provides air flow at a very high velocity. The float does not close before the water has reached the valve. Threaded outlet elbow allows various possibilities of drain connection. The valve design contains a very limited number of parts, allowing an easy dismantling for maintenance. Operation The pressurised air expels the water. The descending water level moves the main float with it. At a certain position the main float pulls down the small seal, that partially opens the nozzle. The pressurised air can escape, the water level rises and the nozzle re-closes. Technical Specications Operating pressure of 0.2 to 16 bars 1/2, 3/4, 1, 2 BSP or NPT threaded base - as per the customer s choice Air flow, even at a critical velocity created by pipeline pressure of 0.9 bar, will not cause premature closure of the valve Structure materials: Body: GRP (UV resistant) Internal parts: corrosion resistant plastic materials and synthetic rubber The valve allows the discharge of 700m3/h of air at pipe pressure of 0.5 bar, when fully-open The DAV-P-2-KA valve has three modes of operation: Discharge of large quantities of air at a high flow velocity when the conduit is being filled. When the water arrives to the valve, the main float rises up and closes the outlet. Introduction of air into the pipeline when the internal pressure is sub- atmospheric. The pressure difference forces the main float to drop to opened position, allowing the air to flow into the pipe. Releasing entrained air from the pipeline. Small quantities of diluted air accumulate in high peaks of the pipeline and in the peak of the valve.

Table 10 Valve 12 mm / 1/2 18 mm / 3/4 25 mm / 1 50 mm / 2 Dimension SI US SI US SI US SI US H Height 183 mm 71/4" 183 mm 71/4" 183 mm 71/4" 249 mm 97/8" W Width 86 mm 31/3" 86 mm 31/3" 86 mm 31/3" 110 mm 41/3" D Thread 1/2" BSP 1/2" NPT 3/4" BSP 3/4" NPT 1" BSP 1" NPT 2" BSP 2" NPT A Nozzle Area 314 mm2 0.49 in2 314 mm2 0.49 in2 314 mm2 0.49 in2 908 mm2 1.41 in2 L Total Width 134 mm 51/4" 134 mm 51/4" 134 mm 51/4" 187 mm 73/8" E Drainage Diameter 3/4" BSP 3/4" BSP 3/4" BSP 3/4" BSP 3/4" BSP 3/4" BSP 11/2" BSP 11/2" BSP Weight 470 g 1.04 lbs. 470 g 1.04 lbs. 470 g 1.04 lbs. 1052 g 2.32 lbs. Table 11 Table 13 Part Description Material 1 Body Glass Reinforced Nylon Optional: Brass 2 Bonnet Glass Reinforced Nylon 3 Float Foamed Polypropylene 4 Kinetic Seal EPDM Rubber 5 O ring NBR 6 Drainage Elbow Polypropylene Table 12 W4.28 DAV-P Air Release Vacuum Break Valves PRESSURE SYSTEMS PG 11 Fig. 18

W4.28 DAV-P Air Release Vacuum Break Valves PRESSURE SYSTEMS PG 12 Branches Nationwide Support Office & Technical Services 09 274 0316 Disclaimer: While every effort has been made to ensure that the information in this document is correct and accurate, users of Hynds product or information within this document must make their own assessment of suitability for their particular application. Product dimensions are nominal only, and should be verified if critical to a particular installation. No warranty is either expressed, implied, or statutory made by Hynds unless expressly stated in any sale and purchase agreement entered into between Hynds and the user.