Magic 485F25 & F9 RS AUTOMATIC RS 485 TRANSMITTER ENABLE

Similar documents
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

NC-12 Modbus Application

1-Port R422/485 Serial PCIe Card

RGB for ZX Spectrum 128, +2, +2A, +3

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Modular I/O System Analog and Digital Interface Modules

OPT SERIAL TO FIBER OPTIC CONVERTER

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Application Note 83 Fundamentals of RS 232 Serial Communications

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

SyncLink GT2/GT4 Serial Adapter

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Model 201 Wiegand Touchpad Reader Installation Guide

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

User Manual IC-485AI

Advanced Data Capture and Control Systems

Current Loop Application Note 1495

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Combi B Alarm box. Mounting instructions

FOM-5A, 6A. Asynchronous Fiber Optic Modem

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

KTA-223 Arduino Compatible Relay Controller

F2400 FOM II Series Fiber Optic Modem Technical Manual

RS-232 COMMUNICATIONS

8 Channel Status Input Panel model SIP-8

USB to RS-422/485 Serial Adapter

PS 155 WIRELESS INTERCOM USER MANUAL

Manual Serial PCI Cards

2-Pair HDSL1 Adtran Fiber Optic Link System

PowerStar Mini Triple Play TM

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Advantium 2 Plus Alarm

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

Eliminate Risk of Contention and Data Corruption in RS-485 Communications

DMX512 TO 0-10 VOLT ANALOG CONVERTER OWNERS MANUAL

CONTROL SWITCHER User s Manual (Preliminary)

MACTek Corporation. USB HART Interface. Users Manual

Sentry. Remote Power Manager. Installation and Setup Manual

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

RC2200DK Demonstration Kit User Manual

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

Application/Connection Examples

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

PEDAL POWER. User s Manual

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

RS-232 Baud Rate Converter CE Model 232BRC Documentation Number 232BRC-3903 (pn5104-r003)

MFRD52x. Mifare Contactless Smart Card Reader Reference Design. Document information

RS - SPM. Serial parallel translator module

FAQ s on Siemens Magmeters

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

2-Port RS232/422/485 Combo Serial PCI Card

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Rack mounted telephone- and leased line modem for industrial applications

Moxa TCC-100/100I User s Guide

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Table of Contents. Creating a VC1000 Network... 3

GARMIN GPS to PC Wiring Instructions

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Multi-Protocol decoder with Load regulation

PCMCIA 1 Port RS EDITION OCTOBER 1999

MIDECO 64-outputs MIDI note decoder USER MANUAL. Roman Sowa 2012

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Digital Controllers ACTUATOR COMPATABILITY

StructureScan HD Module. Installation Guide ENGLISH

A RF18 Remote control receiver MODULE

Original instructions Tina 3A/Aps Adaptor unit

Universal Host. Desktop Digital Hybrid. User Guide. JK Audio

CAN bus board. EB018

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

s!nus-elektrotechnikai bt. Industrial IT & Automation

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

IP Box Camera ACM Ver Hardware User s Manual

Duct Humidity Transmitter

Technical description MX-1 VB Edge

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Contents. Safety Warnings... 1

IO-RM3 3-Stage Relay Module

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

s!nus-elektrotechnikai bt. Industrial IT & Automation

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Paragon Explorer Lite Communication Software

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Bluetooth Serial Adapter

RC Camera Control. User Guide v /20/2012

Installation guide H A. HSI hardwired system interface

Physical Specifications (Custom design available.)

User manual Rev 1.3 Contents

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

DC Electronic Loads 8500 series

xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide

Transcription:

Magic 485F25 & F9 RS 232-485 AUTOMATIC RS 485 TRANSMITTER ENABLE This Instruction Manual is supplied with the to provide the user with sufficient information to utilise the purchased product in a proper and efficient manner. The information contained has been reviewed and is believed to be accurate and reliable, however Amplicon Liveline Limited accepts no responsibility for any problems caused by errors or omissions. Specifications and instructions are subject to change without notice. Magic 485F Instruction Manual Part Nº 859 933 74 Issue A7 Amplicon Liveline Limited Prepared by James Chisholm Approved for issue by A.S. Gorbold, Operations Director

DECLARATION OF CONFORMITY AMPLICON LIVELINE LIMITED CENTENARY INDUSTRIAL ESTATE HOLLINGDEAN ROAD BRIGHTON BN2 4AW UK We declare that the product(s) described in this Instruction Manual perform in conformity with the following standards or standardisation documents: Electro Magnetic Compatibility (EMC): EMC Directive LVD Direcitve CE Directive 89/336/EEC 73/23/EEC 93/68/EEC Jim Hicks, I. Eng, FIEIE Managing Director Amplicon Liveline Limited

2 INTRODUCTION 2.1 General Description The Magic 485F MAGIC converter transfers data between RS232 & RS485 networks. The unit is magic in that, unlike conventional converters, it does not require the RTS signal to control turnaround. Instead the is enabled whenever a valid start bit is detected on the RS232 input. This feature can be very useful when connecting RS232 based modems, or other systems that do not support RTS handshaking to RS485 multidrop networks. The data conversion process changes only electrical levels and the pin-out configuration is in accordance with the appropriate standards. As default the unit is supplied for the RS232 host device configured as Data Terminal Equipment (DTE) but can be changed by jumpers to a Data Communication Equipment (DCE). RS485 multi-drop operation allows up to 32 devices to be connected in a simple network on a single serial bus. The transmitter has a tri-state output and is automatically disabled to allow reception over the same wire pair. DC power for the must be applied from an external source. The DC power lines plus the RS422/485 data and control signals are connected through a pluggable 8 way screw terminal assembly at the free end of the Adapter. EMC Considerations In order to maintain compliance with the EMC DIRECTIVE, 89/336/EEC, it is mandatory that the final system integrator uses good quality screened cables for external connections. It is up to the final system integrator to ensure that compliance with the Directive is maintained. Amplicon Liveline offers a series of good quality screened cables for this purpose. Please contact our sales staff. 2.2 The Products Described in this Manual The 485F range of boards share some common circuitry and features and are referred to in this manual either generically or individually: 485F 485F25 485F9 Refers to both boards Refers to the 25 way D-type version only Refers to the 9 way D-type version only 2.3 Circuit Operation On power up and in a default condition, the circuit is disabled and the RS485 receiver circuit is enabled with the RS232 circuits permanently enabled. This allows the unit to listen to the RS485 network and pass this data to the RS232 interface and be ready to turn around and transmit RS485 data on the network when a data stream is detected on the RS232 interface. When a Start bit or a Space (+V) on the RS232 interface is detected, the is enabled and the RS485 receiver is disabled. The timer controlling the turnaround is reset if necessary and held. Page 1

When the next Mark (-V) in the RS232 data system is detected, the turnaround timer starts and will continue until it is either reset by a Space or times out. If it times out, the is disabled and the RS485 receiver re-enabled. If the timeout occurs before the end of the current bit (which will be a Mark) has been transmitted, the RS485 data will be unaffected as the line biasing will cause the RS485 data lines to default to a Mark. The unit will always respond to a Space by toggling the and receiver circuits. Thus it is a function of the application to insure there is no data on the RS232 interface while there is RS485 data on the network. 2.4 Technical Support Should the appear defective, please check the information in this manual to ensure that the product is being correctly applied. If an application problem persists, please request Technical Support on one of the following numbers: Telephone: UK 01273 944 835 Fax: UK 01273 570 215 E mail Internet support@amplicon.com www.amplicon.com 2.5 Repairs If the requires repair then please return the goods enclosing a repair order detailing the nature of the fault. If the product is still under warranty, which is for a period of 12 months from the date of shipment, there will be no repair charge unless the fault has been caused by misuse. For traceability when processing returned goods, a Returned Materials Authorisation (RMA) procedure is in operation. Before returning the goods, please request an individual RMA number by contacting Amplicon Technical Support by telephone or fax on the above numbers. Give the reason for the return and, if the goods are still under warranty, the original invoice number and date. Repair turnaround time is normally five working days but the Service Engineers will always try to co-operate if there is a particular problem of time pressure. Please mark the RMA number on the outside of the packaging to ensure that the package is accepted by the Goods Inwards Department. Address repairs to: Customer Services Department AMPLICON LIVELINE LIMITED Centenary Industrial Estate Brighton, East Sussex BN2 4AW England Page 2

3 INSTALLATION INSTRUCTIONS 3.1 Requirements of Host Equipment The Magic 485F25 Adapter can be plugged into any device with an RS232 port terminating in a 25 way 'D' type male connector (DB-25). If the host device is equipped with a 25 way connector, it is normally male, and the Magic 485F25 Adapter can be directly plugged into this port. The 485F9 Adapter can be plugged into any device with an RS232 port terminating in a 9 way 'D' type male connector (DB-9). 3.2 Connections to the Connections are made to the at each end. The RS232 connections are automatically made when the Adapter is plugged into the port, and the RS422/485 data, control and power connections must be made through a pluggable 8 way screw terminal connector assembly at the free end. RS422/485 Connections on 8 way Pluggable Terminal Strip The DC power input, RS485 transmission turnaround external control signal and RS422/485 data signal connections are made via an eight way screw terminal connector. The supplied connector can be unplugged from the Adapter for ease of making the cables without removing the Adapter from the port. The connections are compatible with other RS485 Adapters in the Amplicon range, and are shown in FIGURE 2.1 below. The diagram shows the connector as viewed from the top face of the. The abbreviated function names are printed on the printed circuit board below the fixed part of the connector. 1 GND Ground 2 NC 3 B Transmit Data 4 A /Transmit Data 5 A /Receive Data 6 B Receive Data 7 VDC +9.0 to +12 VDC 8 GND Power Ground RS422/485 power, data and control connections FIGURE 3.1 RS422/485 CONNECTIONS Page 3

Half Duplex Connections In half duplex operation, the data signals are both transmitted and received on the two pairs externally wired in parallel with A (pin 4) connected to A (pin 5) and B (pin 3) connected to B (pin 6). Model MA485F9/25 Adapter FIGURE 3.2 CONNECTIONS FOR HALF DUPLEX OPERATION Page 4

3.3 Configuration of Options Configuration of the options is undertaken by the setting of links and switches on the baseboard. For convenience, the plastic case is supplied in two parts and should only be clipped together when any configuration changes have been made. Operational tests can be performed before the case is fitted. SK2 FIGURE 3.3 485F25 BOARD LAYOUT AND JUMPER POSITIONS R4 R3 R2 J2 C2 C4 C5 C6 C7 C2 R5 J1 R1 U3 D1 U4 C3 U5 PL1 J3 R6 U1 C1 Page 5

FIGURE 3.4 485F9 BOARD LAYOUT AND LINK POSITIONS 3.4 Configurable Options Selection of DCE or DTE (485F25 only) The unit, as supplied from the factory, is configured to interface directly to a DTE i.e. a PC or dumb terminal. In the majority of applications this will be correct. This is set by the Jumpers J1 to J2. If required the unit can be converted to connect to a DCE e.g. a moedm, by the repositioning of J1 and J2, as detailed below. Link J1 1-2 & J2 1-2 J1,1- J2,1 & J1,2 - J2,2 Function RS232 connector wired as PC serial port (default factory setting) RS232 connector wired as Modem serial port Selection of Local Echo On/Off in Half Duplex Operation The Factory Default configuration of link J3 toggles the receive and transmit lines with respect to each other in half duplex operation. This mode is also known as Local Echo Off since the transmitted data is not received by the unit in its half duplex wiring configuration. To permanently enable the receive lines (Local Echo On), J3 must be made in its alternate position. Moving this link will not affect the operation of the transmit lines which will still toggle on and off. Link J3 Function MA485F9 MA485F25 Shorted 1-2 Local Echo Off (Factory Default). Opened 2-3 Local Echo On. Transmission Line Termination For proper operation of the RS422/485 bus in full or half duplex, multi-drop or point-to-point communication, it is recommended that termination be applied to the receiver end of the data lines. The simplest form of termination is line-to-line with typically a 120 Ω resistor across the differential input. In a multi-drop system, the terminator resistor is only required at the device receiver located at the far end of the cable. If this is in half duplex operation, then both ends of the bus cable are equipped with receivers (transceivers) so termination is necessary at both ends. Although the will drive loads as low as 27 Ω, in general, circuits are specified as being capable of driving a minimum load resistance of 60 Ω, so no more than two terminator resistors should be connected to any one bus. The is equipped with a terminator resistor for the receiver input pair. This resistor is connected into circuit by the setting of switch SW1 Bit 4 on the 485F25 or solder link J1 on the 485F9. Factory default settings are with the receiver input termination in circuit (SW1-4, on) for the 485F25, and (J1 solder link tracked) for the 485F9. It can be removed from the circuit by setting SW1-4 to off on the 485F25 or cutting the fine track connecting the pads of J1 on the 485F9. Page 6

3.5 Transmitter Turnaround Delay By the nature of the operation of the unit there will be a time delay in the switching of the unit from transmit to receive. This time can be fine tuned to the particular installation and the length of the cable run, resulting in quicker operation. This operation can only be tested on a trial basis and is accomplished by the setting of SW1 Bits 1-3 on the 485F25 as described in Table 2.1, and cutting or resoldering the tracks between the pads of J2 on the 485F9 as shown in Figure 2.5. 1 2 3 4 Function X X X ON RS485 termination on, termination resistor fitted X X X OFF RS485 termination off, termination resistor not fitted OFF OFF OFF X turnaround time = 4 us. ON OFF OFF X turnaround time = 8 us. OFF ON OFF X turnaround time = 16 us. ON ON OFF X turnaround time = 32 us. OFF OFF ON X turnaround time = 64 us. ON OFF ON X turnaround time = 128 us. OFF ON ON X turnaround time = 256 us. ON ON ON X turnaround time = 512 us. (default) TABLE 3.1 485F25 BIT SWITCH SETTINGS AND FUNCTION turnaround time = 4us Turnaround time = 8us Turnaround time = 16us turnaround time = 64us Turnaround time = 128us Turnaround time = 256us Turnaround time = 32us Turnaround time = 512us (default) Position of links on 485F9 R4 R3 R2 FIGURE 3.5 485F9 LINK SETTINGS AND FUNCTION Page 7

3.6 Network Biasing Resistors In some instances, particularly in RS485 multi-drop operation, noise may be detected at the receiver. In the multi-drop configuration, there can be brief periods when no transmitter is enabled, and the network is therefore allowed to float. If this is encountered, two bias resistors (1k2 ohm) can be added externally to the MA485F9/25, so that the network is biased. One resistor should be fitted to the A/A' connection (pins 4 and 5) and GND (pin 8) and the other resistor should be fitted to the B/B' connection (pins 3 and 6) and VDC (pin 7).The arrangement is shown in FIGURE 2.6. Model MA485f9/25 Adapter FIGURE 3.6 NETWORK BIASING RESISTORS 3.7 Power Requirements The must be powered from an external power supply providing a positive output of between +9.0 VDC and +12.0 VDC. This auxiliary power supply unit should be capable of sourcing at least 100 ma for each 485 Adapter that it supplies. Within this constraint, as many 485 Adapters as are required can be fed from a single supply. The Amplicon Mains adapter meets this requirement and the U.K. version is available under order code 919 135 69. See section 2.2 for information on connecting this mains adapter to the Magic 485F terminals. The is fitted with an eight way pluggable terminal strip at its free end, and the power supply should be connected to terminals 7 and 8. Terminal 8 is Ground or negative, terminal 7 is the positive supply. OBSERVE POLARITY when powering the adapter. If the polarity is incorrect, the will not operate, but is protected against damage. 3.8 Connecting the Amplicon Mains Adapter The optional mains adapter plugs directly into a 3 pin, 13 A mains socket (U.K. version), or must be fitted with a suitable plug (International version). The mains supply voltage must be 230 VAC ±10%, 50 Hz. The DC output is by a two-wire cable approximately 2 m in length. This cable is terminated in a moulded connector which must be cut off and discarded. The two wires can then be parted and stripped back about 6 mm. The black wire is negative and goes to terminal 8 (GND) of the, and the black wire with a white stripe is positive and goes to terminal 7 (VDC). Section 2.9 gives the Amplicon order codes for the above adapters. Page 8

3.9 Optional Accessories U.K. Mains Adapter Power Supply Amplicon Description Function Order Code 919 135 69 Plug-in mains Provides +9 VDC at 200 ma to power one or two Magic Adapter 485F Adapters. Mains operated 230/240 VAC. Integral 3 pin, 13 A, UK style plug. Two wire output cable of 2 m length. Moulded connector to be removed for screw terminal connection to. Wire with white stripe is positive. The U.K. Mains Adapter complies with the requirements of British Standard BS415 International Mains Adapter Power Supply 919 448 69 Wired-in mains Provides +9 VDC at 200 ma to power one or two Magic Adapter 485F Adapters. Mains operated 220/230 VAC. Two wire (Brown - live, blue - neutral), 1.5 m length mains input cable. Two wire output cable of 2 m length. Moulded power connector to be removed for screw terminal connection to. Wire with white stripe is positive. Page 9

4 TECHNICAL SPECIFICATION The technical characteristics of the are in accordance with the following electrical and physical specifications. Except where otherwise noted, all specifications are typical at 25º C Electrical Specification Supply Voltage Supply Current RS232 'High' signal input RS232 'Low' signal input RS232 Input Resistance RS232 'High' signal output RS232 'Low' signal output RS232 Output Resistance RS422/485 Input sensitivity RS422/485 Input Hysteresis RS422/485 Output drive RS422/485 Output load RS422/485 Receiver I/P Termination Data Rate RS232 Connector RS422/485 Connector +9.0 VDC to +12.0 VDC from external supply via terminal strip 50 ma plus current drawn by output loads 200 ma fully loaded +2.4 to +30 V 30 to +0.8 V 5 kω +9 V 9 V 300 Ω 0.2 V 70 mv 1.5 V minimum, fully loaded 27 Ω minimum 120 Ω resistor across differential input terminals. Can be disconnected by switching SW1-4 120 kbd max 25 way DB-25 female connector with screw-locks 8 way pluggable screw terminal assembly Physical/Environmental Specification Module with connector Packed Size 67 x 53 x 20 mm 215 x180 x 80 mm Weight 60 gm 250 gm Temperature Range Operating Storage 0 C to +60 C -20 to +70 C Page 10