Dependapower TRANSPORTABLE DPGOU PUMPS 6040 CAT-R Goulds/ SECTION INDEX 6,000 GPM Dependapower The Dependapower DPGOU DPPAT 6040 CAT-R 4025 is CAT-R...A2 a trailer mounted, diesel driven horizontal split case centrifugal fire water pumping system. Nominal performance rating is 6,000 gpm @ 150 psi net (10 lift). Designed to be moved from one location to another without having to realign the Patterson/ pump coupling. Entire assembly is built 4,000 on a skid GPM base which also serves as a fuel tank. Also includes structural frame with lifting lugs and work lights. Electric start with dual electric primers. Total Package Weight with Fuel = 20,000 lbs. Dependapower DPGOU 6040 CAT-R... A3 Triple axle 24,000 lb. GAWR steel decked trailer, complete with; electric brakes and coupler, DOT lighting package; leveling jack with rear stabilizer Goulds/ jacks; 235/85 R16 tires/wheels. 6,000 GPM NHancer Low Pressure Goulds / Hi-Volume Pump... A4-A5 Series 3409 10 x 14 x 20 L Cast iron casting, Bronze trim Performance @ Shutoff 200 psi 6,000 gpm - 150 psi 4,000 gpm - 175 psi Dual Electric 3412-DITA 750 BHP @ 1800 rpm 14 diameter header, furnished with: six (6) 6 (M) NH inlet connections - capped and one (1) 2.5 valved (F) NST swivel w/plug. 10 diameter header, furnished with: six (6) 5 Storz discharge connections, capped, six (6) worm gear operated butterfly valves - 5, two (2) 2.5 (M) auxiliary valved discharge connections - capped. Includes: start/stop switch, tachometer, oil pressure gauge, coolant temperature gauge, amp meter, vernier throttle, compound suction gauge, discharge pressure gauge, fuel pressure gauge, primer valves & switches, hour meter. 6 NH hard suction hoses (20 each - 6 req d) or (10 each - 12 req d) 6 Non-floating basket strainers (6 req d) PRODUCTS 409-745-3232 A1
Dependapower DPPAT 4025 CAT-R Patterson/ 4,000 GPM The Dependapower DPPAT 4025 CAT-R is a trailer mounted, diesel driven horizontal split case centrifugal fire water pumping system. Nominal performance rating is 4,000 gpm @ 150 psi (10 lift). The pump and driver come mounted on a skid containing an integral 325 gallon fuel cell with level indicator. The easily detachable skid is transported on a dual-axle trailer. The 12 suction and 10 discharge headers provide minimal pressure loss for maximum efficiency. The 24VDC electrical system comes standard with two group-d batteries. Paint is basic red polyurethane finish on pump, skid and trailer. (*Not on Driver) Total Package Weight with Fuel = 15,000 lbs. Gooseneck style dual axle 14,000 lb. GAWR trailer, complete with: electric brakes & coupler; DOT lighting package; 235/85 R16 LRF tires/wheels. Deck areas covered with safety Grip surface. Patterson Series MAA 12 x 8 x 20.3 Cast iron casting, Bronze trim, SS packing sleeve Performance @ Shutoff 200 psi 4,000 gpm - 150 psi / 2,500 gpm - 175 psi One Electric vane primer & reservoir *Paint 3406-DITA 500 BHP @ 2100 rpm Standard base unit yellow 12 diameter flange-fitted header furnished with: four (4) 6 (M) NH inlet connections, capped & one (1) 2.5 valved (F) NST swivel w/plug. 10 diameter flange-fitted header, furnished with: four (4) 5 storz discharge connections, capped, with gated discharge valves: (1) 2.5 (M) valved discharge connections. Includes: start/stop switch, tachometer, oil pressure gauge, coolant temperature gauge, amp meter, vernier throttle, compound suction gauge, discharge pressure gauge, fuel pressure gauge, primer valves & switches, hour meter. Manual clutch between pump & driver Four suction hose racks (passenger side only) for use with 10 hoses only SS Suction/Discharge Manifolds Automatic battery charger Retractable awning over pump operator 6 NH hard suction hoses (20 each - 4 req d) or (10 each - 8 req d) 6 NH Light Weight hard suction hoses (20 each - 4 req d) or (10 each - 8 req d) 6 Non-floating basket strainers (4 req d) 6 Floating basket strainers (4 req d) Full skid cover Add, 2.5 Discharge/Suction 4 Work Lights PRODUCTS 409-745-3232 A2
Dependapower DPGOU 6040 CAT-R Goulds/ 6,000 GPM The Dependapower DPGOU 6040 CAT-R is a trailer mounted, diesel driven horizontal split case centrifugal fire water pumping system. Nominal performance rating is 6,000 gpm @ 150 psi net (10 lift). Designed to be moved from one location to another without having to realign the pump coupling. Entire assembly is built on skid base which also serves as a fuel tank. Also includes structural frame with lifting lugs and work lights. Electric start with dual electric primers. Total Package Weight with Fuel = 20,000 lbs. a Triple axle 24,000 lb. GAWR steel decked trailer, complete with; electric brakes and coupler, DOT lighting package; leveling jack with rear stabilizer jacks; 235/85 R16 tires/wheels. Goulds Series 3409 10 x 14 x 20 L Cast iron casting, Bronze trim Performance @ Shutoff 200 psi 6,000 gpm - 150 psi 4,000 gpm - 175 psi Dual Electric 3412-DITA 750 BHP @ 1800 rpm 14 diameter header, furnished with: six (6) 6 (M) NH inlet connections - capped and one (1) 2.5 valved (F) NST swivel w/plug. 10 diameter header, furnished with: six (6) 5 Storz discharge connections, capped, six (6) worm gear operated butterfly valves - 5, two (2) 2.5 (M) auxiliary valved discharge connections - capped. Includes: start/stop switch, tachometer, oil pressure gauge, coolant temperature gauge, amp meter, vernier throttle, compound suction gauge, discharge pressure gauge, fuel pressure gauge, primer valves & switches, hour meter. 6 NH hard suction hoses (20 each - 6 req d) or (10 each - 12 req d) 6 Non-floating basket strainers (6 req d) PRODUCTS 409-745-3232 A3
Lo-Pressure / Hi-Volume Submersible Pump N-Hancer Submersible Pump S u b m e r s i bl e Pu m p Trailer mounted diesel driven submersible pump. Originally designed for agricultural service, now redesigned for utilization for the fire service industrial and municipal. Industrial uses (1) de-inventory water flooded areas in process areas, tank farms, etc. from flooded waterways or tropical events, (2) re-inventory water to supply fire water from restricted inventory levels, (3) gain access to water supplies otherwise not available, and (4) enhance pumping operations to make existing centrifugal pumps more effective by reducing the strain by pumping from draft. Municipal uses (1) in optimal areas, supply large volumes of water to municipal pumpers (either professional or volunteer departments) during large fire operations requiring significant support, (2) improve water shuttling operations to maintain supply needs for insurance ratings for departments, and (3) support for areas affected by flooding. Pump easily backs into any available water source of at least 2-foot depth. Features: Trailers are fitted with a 2 ball coupler, and can be pulled over the road by a ¾-ton truck. Trailers can be spotted in place (in a waterway) with same vehicle. Suggested logistical deployment would be via flatbed truck for long distances. The trailers are road legal, but would need appropriate tags and serial numbers. Trailers are outfitted with lifting lugs in the event conditions would not permit placement via vehicle (pump and motor weight is less than 6000 lbs). Visually accessible grease fittings. In field testing the large N-Hancer pump provided 9000 gpm to the pump suction of a Williams 6000 pump (Patterson package) and was demonstrated with a Ranger 3 nozzle and an Ambassador monitor results indicated a flow rate of 8,326 gpm at the monitors at 125 psi. Visually accessible grease fittings at the operator panel Adaptations: Pumps are outfitted with a dual 12 Storz discharge manifold, and include 2 sections of 50, 12 hose with Storz connections, and 2 distribution manifolds each with 12 Storz inlet and 4, 6 Storz outlets manifolds are constructed of stainless steel. Pump Data: Small Pump Pump Data: Large Pump At 1000 RPM Flow At 1000 RPM 2000 gpm 3000 gpm 4000 gpm Head (ft) 86 80 67 Head (ft) Effy % 56 69 67 Effy % 60 64 40 HP (~) 78 88 100 HP (~) 120 145 176 PRODUCTS 409-745-3232 Flow 4000 gpm 6000 gpm 9000 gpm 71.5 61.5 32.5 A4
s Available (presently through WF&HC): Small Pump Discharge Suction Flow Head (ft) 10 pipe... Fitted with a single 12 Storz discharge to reduce friction & pressure loss 8 double suction 4000 gpm 70 160 hp Deutz diesel direct drive 50 gallon fuel tank 6 hours of runtime Large Pump Discharge Suction Flow Head (ft) 16 pipe... Fitted with two (2) 12 Storz connections at the discharge manifold 10 double suction 9000 gpm 50 176 hp Deutz diesel direct drive 50 gallon fuel tank 6 hours of runtime PRODUCTS 409-745-3232 A5