DTM Distributed Transmitter Monitor

Similar documents
Proximity Transmitters and Seismic Vibration Transmitters

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Portable and Online Condition Monitoring System

Electronic, Digital and Mechanical Vibration Switches

SKF Machine Condition Transmitters (MCT) Series

3500/40M Proximitor* Monitor

1900/65A General Purpose Equipment Monitor

PIEZOMETER AIRFLOW MEASURING RING

TX2123 RS485 TO ETHERNET ADAPTOR

1900/65A General Purpose Equipment Monitor

with Electronic Assistant

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

1701/22 FieldMonitor Management Interface Module

3500/22M Transient Data Interface

3500/25 Enhanced Keyphasor*Module

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Electronic Control Devices The European Product Catalogue 2007

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Electronic Control Devices The European Product Catalogue 2007

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Unidirectional Transmitter/ Receiver Units Introduction

MCR1900 Media Converter 19-Slot Chassis

Ordering Part Numbers:

3DLevelScanner II TECHNICAL DATA SHEET

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

WD-AMX Water Detection Controllers

Model: DC-A2IO Advanced HVAC Controller

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

VIBRATION SWITCHES SOLID STATE

NC-12 Modbus Application

Series 6000 Torque measured metal bellow coupling

3500/93 System Display

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

UIM2901-5A MACH3 breakout board

Telephone- and leased line modem for industrial applications TD-36

How To Power A Schen

Description. Dimensions. Features. precision works better

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Technical Data Sheet. 3DLevelScanner

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Dynamic Pressure Charge Amplifier

Operating Instructions

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Single Channel Loop Detector

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Thyristor-controlled power supplies and battery chargers

Auto-tune PID. Temperature Controller BRAINCHILD FEATURES

How To Use A Ds340 (Dsp)

The Universal DAQ Device. Connect and measure immediately!

Contents. Document information

Temperature & Humidity SMS Alert Controller

LT-82 Stationary IR Transmitter

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Vibration Monitoring System Adash 3600

DPI 260 SERIES: Digital Pressure Indicators

Operating Instructions

Research RF Sputtering Packages

Rack mounted telephone- and leased line modem for industrial applications

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

- 1 - Eddy Current. Eddy current distance and displacement transducer

CE6500 Energy Recovery Ventilator

Operating Instructions

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Diesel Engine Driven Generators Page 1 of 6

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

GSM Gate Opener GSM Remote Switch RTU5015 User Manual

Everything you need for protection scheme testing

Absolute Rotary Encoder E6CP

HMI display Installation Guide

Series 7500 Torque Sensor

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Perimeter Security System

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

OPT SERIAL TO FIBER OPTIC CONVERTER

INTREPID Perimeter Intrusion Detection System

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

MLC TM Maximum Productivity and Versatility for Control without Compromise!

The L&J Engineering Model MCG 1500SFI Servo Gauge

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

DS 600. A contact free flux gate based current measurement sensor 600A rms

DSA800 Series Spectrum Analyzer

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Transcription:

DTM10 Proximity Distributed Transmitter Monitor (Radial Shaft Vibration, Thrust Position and Speed) The DTM10 distributed vibration transmitter monitor provides a simple and cost-effective solution for monitoring critical and balance of plant equipment. The DTM design is extremely reliable with redundancy in power supply inputs, 4-20mA outputs and relay outputs as well as a modbus communication port. The DTM can interface with almost any proximity system (Proximity probe, extension cable and with or without probe driver). The DTM is fully digital and can be fully field-configurable or factory pre-configured. Applications Include Turbines Compressors Motors Pumps Fans Blowers Centrifuges Generators Turbochargers DTM10 Fully Configurable by Software Radial Vibration Thrust Position Speed Phase Reference DTM10 Features Interface with any manufacturers proximity probe system Works with or without probe driver Direct Modbus RTU interface Redundant 4-20mA outputs Redundant power supply inputs Measures radial shaft vibration, thrust position, speed and phase reference Fully digital field-configurable Dual relay outputs (SPDT) LED indication of system, Alert, Danger, Bypass, and digital transmitting Local and remote RESET/ and Trip-multiply Buffered output for condition monitoring Aluminum case for RFI/EMI protection ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com 6

Specifications Electrical Power Supply: 22-30VDC, 150mA Galvanic isolation: power to circuits Accepts dual power supply inputs Frequency Response (±3dB): Nominal frequency: 4-4.0 KHz Low frequency: 0.5-100Hz Proximity Probe Interface: Sensitivity: 5mm and 8mm probe: 8 mv/um (200 mv/mil) 11mm probe: 4 mv/um (100 mv/mil) 25mm probe: 0.787 mv/um (20 mv/mil) Calibration: Requires two specifying probe systems for factory calibration. Field calibration with any manufacturers 5mm, 8mm and 11mm probes is available with TM0540 or TM0541 proximity probe static calibrator. Buffered Output: Original, un-filtered signal Impedance: 550Ω Maximum cable distance: 300m (1,000ft) Sensitivity: same as the sensor Local BNC connection Remote terminal connection Overall Vibration: Dual 4-20mA, source Maximum load resistance 380Ω Alarm Setup: 0-100% FS Accuracy: ±0.1% Relays: Seal: Epoxy. Capacity: 0.2A/240VAC, 0.4A/110VAC or 2.0A/24VDC, resistive load Relay type: SPDT Isolation: 1,000VDC LED Machine Condition Indicator: : System indication ALT: Vibration over level DNG: Vibration over level BYP: System in TRX: Digital Transmitting RESET/ : Local Reset: On monitor front panel Remote RESET/: Shoring the connector pin RESET and COM will engage system reset and bypass Trip-Multiply: Shorting the connector pin Trip Multi and COM will engage system alarm level increases to factory set levels. Modbus: Modbus RTU. With RS485 not isolated from the system, isolation can be done with DTM96. Physical Dimensions: Height: 75mm (2.95 ) Weight: 2.0lbs (1.0kg) Environmental Temperature: Operation: -40 o C to +85 o C Storage: -50 o C to +100 o C Humidity: 90% non-condensing Case: Aluminum casted (copper free) case + Certifications CE certified with EMI compliance DTM-VIBRATION ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com 7

Order Information * Factory default DTM10-AX-BX-CX-EXX-SX Customer fully-configurable proximity DTM (requires DTM-CFG software) AX: Alarm A0: Dual alarms with epoxy sealed relays A1: No alarm BX: Mounting B0: DIN rail mount B1: Plate mount CX: External Proximity Driver C0: Not required (requires probe and extension cable) (301, 302, 502 type modules) C1: Required (requires probe, extension cable and probe driver) (201, 202, 501 type modules) EXX: Probe and Cable (Series and Length) Purchased Separately E00*: TM0180, 5m Cable E01: TM0180, 9m Cable E02: 8mm Probe, 3300, 5m Cable E03: 8mm Probe, 3300, 9m Cable E04: 8mm Probe, 7200, 5m Cable E05: 8mm Probe, 7200, 9m Cable E06: TM0105, 5m Cable E07: TM0105, 9m Cable E08: TM0110, 5m Cable E09: TM0110, 9m Cable E10: 11mm Probe, 3300, 5m Cable E11: 11mm Probe, 3300, 9m Cable E12: 11mm Probe, 7200, 5m Cable E13: 11mm Probe, 7200, 9m Cable E99: Other probe systems (requiring field calibration) DTM10-201-AX-CX-GX-IX-SX Factory pre-configured for radial vibration (probe driver required) A0*: 0-200um pk-pk A1: 0-1,000um pk-pk A2: 0-100um pk-pk Continued A3: 0-10mil pk-pk A4: 0-50mil pk-pk A5: 0-5.0mil pk-pk A6: 0-200um pk-pk (0.5-100Hz) A7: 0-1,000um pk-pk (0.5-100Hz) A8: 0-100um pk-pk (0.5-100Hz) ing IX: Frequency Response I0*: Normal frequency I1: Low frequency (0.5-20Hz) DTM10-202- AX-CX-GX-SX Factory pre-configured for axial (thrust) position (probe driver required) A0*: 1.0-0 - 1.0mm (40-0 - 40mil) (requires TM0180 or other 8mm proximity probe transducer; TM0105 or other 5mm proximity probe A1: 2.0-0 - 2.0mm (80-0 - 80mil) (requires TM0110 or other 11mm proximity probe A2: 5.0-0 - 5.0mm (0.2-0 - 0.2inch) (requires TM0120 or other 25mm, 35mm proximity probe A3: 12.0-0 - 12.0mm (0.5-0 - 0.5inch) (requires TM0150 or other 50mm proximity probe ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com 8

DTM10-501-AX-CX-FXX-GX-SX Factory pre-configured for speed/ phase reference (probe driver required) A0: 0-1,000 rpm A1*: 0-3,600 rpm A2: 0-6,000 rpm A3: 0-10,000 rpm A4: 0-30,000 rpm A5: 0-50,000 rpm FXX: Teeth per Revolution F01*: 1 FXX: Customer specifies, number of teeth =XX EXX: Probe and Cable Continued E05: 8mm Probe, 7200, 9m Cable E06: TM0105, 5m Cable E07: TM0105, 9m Cable E08: TM0110, 5m Cable E09: TM0110, 9m Cable E10: 11mm Probe, 3300, 5m Cable E11: 11mm Probe, 3300, 9m Cable E12: 11mm Probe, 7200, 5m Cable E13: 11mm Probe, 7200, 9m Cable IX: Frequency Response I0*: Normal frequency I1: Low frequency (0.5-20Hz) DTM10-302-AX-CX-EXX-GX-SX Factory configured for axial (thrust) position (built-in probe driver) DTM10-301-AX-CX-EXX-GX-IX-SX Factory pre-configured for radial shaft vibration (with built-in probe driver) A0*: 0-200um pk-pk A1: 0-500um pk-pk A2: 0-100um pk-pk A3: 0-10mil pk-pk A4: 0-25mil pk-pk A5: 0-5.0mil pk-pk A6: 0-200um pk-pk (0.5-100Hz) A7: 0-500um pk-pk (0.5-100Hz) A8: 0-100um pk-pk (0.5-100Hz) EXX: Probe and Cable (not included) E00*: TM0180, 5m Cable E01: TM0180, 9m Cable E02: 8mm Probe, 3300, 5m Cable E03: 8mm Probe, 3300, 9m Cable E04: 8mm Probe, 7200, 5m Cable A0*: 1.0-0 - 1.0mm (40-0 - 40mil) (requires TM0180 or other 8mm proximity probe A1: 2.0-0 - 2.0mm (80-0 - 80mil) (requires TM0110 or other 11mm proximity probe EXX: Probe and Cable (not included) E00*: TM0180, 5m Cable E01: TM0180, 9m Cable E02: 8mm Probe, 3300, 5m Cable E03: 8mm Probe, 3300, 9m Cable E04: 8mm Probe, 7200, 5m Cable E05: 8mm Probe, 7200, 9m Cable E06: TM0105, 5m Cable E07: TM0105, 9m Cable E08: TM0110, 5m Cable E09: TM0110, 9m Cable E10: 11mm Probe, 3300, 5m Cable E11: 11mm Probe, 3300, 9m Cable ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com 9

EXX: Probe and Cable Continued E12: 11mm Probe, 7200, 5m Cable E13: 11mm Probe, 7200, 9m Cable DTM10-502-AX-CX-EXX-FXX-GX-SX * Factory default Optional Accessories DTM-CAL The DTM field calibration kit is capable of calibrating with any 5mm, 8mm and 11mm probe system. The kit includes: Factory pre-configured for speed/ phase reference (built-in probe driver) DTM-CFG configuration and calibration software CD RS485-USB converter with cable TM0540 proximity probe field calibration kit A0: 0-1,000 rpm A1*: 0-3,600 rpm A2: 0-6,000 rpm A3: 0-10,000 rpm A4: 0-30,000 rpm A5: 0-50,000 rpm EXX: Probe and Cable (not included) E00*: TM0180, 5m Cable E01: TM0180, 9m Cable E02: 8mm Probe, 3300, 5m Cable E03: 8mm Probe, 3300, 9m Cable E04: 8mm Probe, 7200, 5m Cable E05: 8mm Probe, 7200, 9m Cable E06: TM0105, 5m Cable E07: TM0105, 9m Cable E08: TM0110, 5m Cable E09: TM0110, 9m Cable E10: 11mm Probe, 3300, 5m Cable E11: 11mm Probe, 3300, 9m Cable E12: 11mm Probe, 7200, 5m Cable E13: 11mm Probe, 7200, 9m Cable FXX: Teeth per Revolution F01*: 1 FXX: Customer specifies number, number of teeth =XX DTM-CFG-K DTM configuration and calibration software kit includes: DTM-CFG configuration and calibration software CD RS485-USB converter with cable TM900 Power converter with isolation. It converts 95-250 VAC into 24VDC and is capable of powering up to five DTM modules. Probe systems TM0180: 8mm probe TM0105: 5mm probe TM0110: 11mm probe TM0181: Extension cable TM0182: Probe driver TM0120: 25mm probe system TM0200 3-1/2 digit display unit. Requires 110VAC or 230VAC power input. ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com 10

DTM10-201/202/501 Field-Wiring Diagram + Notes: Power supply 2 is optional Alert and Danger relays are connected as normally open. Connect ARM with NC to form a normally closed configuration 4-20mA (2) is optional Closing COM and RST/BYP with an external continuous or momentary switch will initiate a remote reset. Temporarily closing the switch will result in a system reset, continuous close will result in a system bypass. DTM10 series is compatible with other manufacturers probes, extension cables and probe drivers. ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com 11

DTM10-201/202/501 Hazardous Area Field-Wiring Diagram + Notes: Power supply 2 is optional. Alert and Danger relay are connected with normally open. Connect ARM with NC to form a normally closed configuration. 4-20mA (2) is optional. Closing COM and RST/BYP with an external continuous or momentary switch will initiate a remote reset. Temporarily closing the switch will result in a system reset, continuous close will result in a system bypass. DTM10 series is compatible with other manufacturers probes, extension cables and probe drivers. Other barriers available: TM0404: (MTL5042) TM0414: (STAHL 9002/00-260-138-001) ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com 12

DTM10-301/302/502 Field-Wiring Diagram + Note: Power supply 2 is optional. Alert and Danger relays are connected as normally open. Connect ARM with NC to form a normally closed configuration. 4-20mA (2) is optional. Closing COM and RST/BYP with an external continuous or momentary switch will initiate a remote reset. Temporarily closing the switch will result in a system reset, continuous close will result in a system bypass. DTM10 series is compatible with other manufacturers probes, extension cables and probe drivers. ProvibTech Phone: +1-713-830-7601 Fax: +1-281-754-4972 sales@provibtech.com www.provibtech.com 13