A-9,000 Waterproofing Basecoat System With Texture Finish

Similar documents
How to Install Hardwood Flooring Over a Sub Floor

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

Natural Thin Stone Veneer

How to Install UnderDeck The Original.

Asphalt Shingle Application Requirements

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Shingle Installation Guide

K2 STONE NATURAL VENEER

INSTALLATION OF A BAY WINDOW

Minor Cracks in Horizontal Surfaces

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

How To Install Hardwood Flooring

How to Install GoBoard:

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Installation Manual for STANDING SEAM ROOFING

Resurfacing Concrete. Page 1 of 5

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

Bella Cera Engineered Hardwood Flooring Installation Instructions. Check for Proper Color Selection Prior to Installation

Sun Windows General Information Sun New Construction Window Installation Instructions

How to repair your existing low slope flat roof.

Installation Instructions

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Thin Veneer Stone Installation Guide

METAL ROOFING INSTALLATION GUIDE

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

Manufactured Stone Veneer Installation Instructions

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

INSTALLATION INSTRUCTIONS

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

PAINT. PAINTING WALLS Interior Walls -Exterior Walls PAINTING DOORS CLEAN UP

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

How to Replace Windows in Stucco-Clad Walls

Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ Smooth cap sheet SQ $ 36.

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

Barewood Octagon and Elongated Windows Installation Instructions

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

The minimum reinforcement for the stem wall is the placement of:

Engineered Hardwood Flooring Installation Instructions

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

Third Party Inspection Guidelines For Inspectors As Part of the dryvitcare EIFS Repair/Restoration

Superform Products Ltd.

AMERICAN GOTHIC PLAYHOUSE

Window Installation Instructions

Laminate Flooring T-Lock Angle-Drop Installation Instructions

Product Information/Specifications

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

International Greenhouse Company

LAYING BLOCK AND BRICK

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

PUMP JACK SYSTEM AND ACCESSORIES

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

Owner's Manual & Assembly Instructions

SECTION STANDING SEAM METAL ROOFING

FRAMED & MOUNTED TILE MURAL

INSTALLATION IMPORTANT INSTALLER/OWNER RESPONSIBILITY TOOLS & EQUIPMENT NEEDED FOR INSTALLATION PRE-INSTALLATION PROCEDURES & JOBSITE CONDITIONS

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Composite Stone Veneer

Directions For Applying Malarkey Laminate Shingles

PERIMETER FLASHING. Table of Contents

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

You have just purchased the most portable and economical spray chrome system in the world!

Tundra Series Windows January 2016

Best Barns USA Assembly Book

Although we do a fair amount of residential roofing, my family s breadand-butter. Installing a. Sealants aren t universal

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs

Installing Window Trim and Door Trim

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

RESTORE 10X Advanced Resurfacer FAQs Page 1 of 11

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

DUROCK Brand Cement Board. installation guide. Substrate and ceramic tile installation for walls, floors, countertops and wall shields.

The existing roof angle change terminations and flashings when sound and intact can be reused.

ROOF DRAINS TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

2015 DuROCK Alfacing International Limited

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

SUPER SHED. Indoor shelter for your outdoor tools.

!!! !!!! !!! !!! !!! !!! !!!!!!!!! Table of Contents! Section 1: Most Common Types of Flat Roofing! Section 2: Better Understand Your Flat Roof!

STUCCOMAX Installation Specifications Exterior One-Coat Stucco over EPS Foam, PU Foams, Exterior Gypsum Board, MgO Board and Cement Block

WATERPROOFING FOR CONCRETE STRUCTURES

Protecting Your Home from Wind Damage

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Detached accessory structures that contain no conditioned floor area are exempt.

6.0 Implementation: Retrofitting Gable End Walls with L-Bent Straps

How to Build a Poker Table

INSTALLATION INSTRUCTIONS

Herringbone Pattern Flooring

SWD URETHANE COATED FOAM ROOFING SYSTEM MASTER ROOF SPECIFICATION SECTION

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Transcription:

A-9,000 Page 1 A-9,000 Waterproofing Basecoat System With Texture Finish Description This specification is designed and engineered for above grade structures that require waterproofing. Americrete s Waterproofing Basecoat System was designed as a lightweight waterproofing system that provides a durable coating for plywood. This system will withstand heavy foot and vehicular traffic. Limitations Americrete s Waterproofing Basecoat System must be placed on structurally sound surfaces only. Wood Structures Wood surfaces must be free of oils, contaminants, trash, sawdust, etc. and must be structurally sound and secured by screws or ring shank nails and blocked at all plywood seams before application. This system can be applied directly over existing wood surfaces consisting of 5/8 tongue and groove plywood or thicker. This system is not approved over ½ plywood or OSB board. Apply over recommended surfaces only. Plywood must have a ¼ fall per foot (slope). Metal Flashing Metal Flashing should be 26 gauge galvanized metal or better. Flashing shall be clean and rust and/or corrosion free. All oils should be removed with mineral spirits. All wall to deck flashing shall be 4 x 4 or better. Flashing shall be overlapped by 3 to 4 and caulked with 2 beads top and bottom at all overlapped areas. Vertical and horizontal caulking shall be Sika 1A polyurethane or equal. Fascia flashing is to be 2 x 4 or better with no gravel stop. All flashing is to be nailed every 4 and vertical areas to be nailed at the top of all stud areas. Plywood Seam All plywood seams must be nailed with ring-shank nails or screws and must be blocked. Metal Lath A 2.5 gauge galvanized expanded metal lath must be applied over entire plywood and metal surfaces with all diamond metal lath seams overlapping 1 to 2. Lath to

A-9,000 Page 2 be fastened by stapling with galvanized 1 by 5/8 crown staples, minimum of 18 staples per square foot. All overlapped lath shall have staples every 1 on the seams. Crickets When installing lath on an enclosed parapet wall deck, crickets are required to get water off the deck and into scuppers or drains. You can achieve this by cutting lath pieces at 45-degree angles and nailing them between drains or scuppers. Use 3 pieces of lath, each one cut smaller than the prior, and lay them on top of another and secure with staples or nails. This will achieve a gradual build-up when A-900 Waterproofing Basecoat is applied into lath. Waterproofing Basecoat Mix 4 ½ to 5 quarts of water to 1 bag of A-900 Waterproofing Basecoat. Apply wet mixture directly into, 2.5 galvanized, diamond lath at a rate of 30 to 35 square feet per mix. Metal lath must be completely covered. Allow to dry. Waterproofing Primer and Flex Mesh Apply A-1600 Flex Mesh over entire surface with 1 to 2 overlap at all seams. Saturate A-1600 Flex Mesh with A-8100 Waterproofing Primer and allow to dry. Concrete Resurfacer Mix 5 ½ to 6 quarts of water to 1 bag of A-600 Concrete Resurfacer. Apply A- 600 Concrete Resurfacer over A-1600 Flex Mesh at a rate of 150 square feet per mix. This can be done with a trowel or squeegee. Knock Down Texture If the surface is not smooth, apply an additional slurry coat of A-600 Concrete Resurfacer. Mix 4 ½ to 5 quarts of water to A-800 Texture Finish and apply to deck with a hopper gun at a rate of 125 to 150 square feet per bag. In golf shoes or spikes, knock down A-800 Texture Finish with a trowel, keeping trowel clean and damp with wet rag or sponge. Let dry for 24 hours. Apply A-1100 Texture and Color Seal over surface (2 coats). Apply the first coat at a rate of 125 to 150 square feet per gallon. Allow to dry and then apply a second coat at a rate of 125 to 150 gallons per square foot. This specification is intended only as a guideline since Americrete products are warranted to Certified Applicators only. Flashing Procedure for Americrete s Waterproofing System 1. Apply 4 x 4 or 6 x 4 flashing at walls and over threshold areas. Overlap flashing ends by 4 and apply 2 beads of caulking Sika 1-A, or the equivalent, at each seam of the flashing, top and bottom. Put 2 nails at all

A-9,000 Page 3 vertical and horizontal seams, top and bottom. Nail the flashing that is laying on the deck surface, every 4 to 6. Nail the flashing that goes up the wall at every stud. End the flashing at a stud. Wall Side Flat side that lays on the deck 2. If the deck is an open rail deck, at the end of the deck, extend the flashing 4 to 6 and bend it around to the wall so the stucco paper can be applied over the 4 x 4 flashing. 3. Then apply 2 x 4 fascia flashing at the end of the deck. Remember to caulk and nail all of the areas where metal is overlapping. 4. If stucco is to be applied at the edge of the deck, be sure to leave the flashing ¾ beyond the deck to accept the stucco. The stucco should be under the flashing. 5. If no fascia flashing is required, and you have a wall, you must have scuppers, drains or both, and an overflow scupper so the water will drain properly. 6. If drains are required, Americrete approves only Thunderbird Deck Drains. Never use copper drains, scuppers or copper flashing with our metal lath systems to avoid electrolysis. If scuppers or drains are required, be sure the distance between each is no more than 6 feet. Install crickets between scupper with lath and A-900 Waterproofing Basecoat. Build up at 45- degree angle to divert water to drains. 7. All decks must have at least 5/8 Tongue and Groove Plywood blocked at all seams, with joists 16 on center and they must be 2 x 8 or greater with 1/4 fall per foot. All decks are to be screwed or nailed with ring-shank nails, glued and blocked. Application Procedure Metal Lath Waterproofing Systems with Texture Note: Always use Americrete flashing procedures. 1. Apply 2.5 galvanized, metal lath over the deck surface and fasten with 5/8 x 1 crown, non-corrosive staples. Staple patterns must be a minimum of 18 staples per square foot. All lath seams must overlap 1 to 2 and metal lath shall be no more than ½ away from the walls or edge of the deck covering all flashing. Hammer staples down at lath seams before applying A-900 Waterproofing Basecoat. 2. After lath has been applied, mix 4 ½ to 5 quarts of water to 1 bag of A-900 Waterproofing Basecoat and trowel into the lath at a rate of 30 to 35 square feet per bag (lath should be completely covered). Allow to dry completely. 3. Apply A-1600 Flex Mesh over the entire surface and saturate the nylon mesh with A-8100 Waterproofing Primer by using a roller. Allow it to dry. 4. Mix 5 ½ to 6 quarts of water per bag of A-600 Concrete Resurfacer and apply using a squeegee at a rate of 150 square feet per bag and cover the A- 1600 Flex Mesh completely.

A-9,000 Page 4 5. Next, for a knock down finish, mix 4 ½ to 5 quarts of water to a bag of A- 800 Texture Finish. 6. Put the material into a Hopper Gun with low pressure. 7. Apply by spraying material onto the deck. Let it set-up. Do not allow it to dry, walk onto the surface with golf shoes or spikes and proceed by knocking down the Texture Finish with a trowel. Allow it to dry for 24 hours. 8. Scrape the deck and blow or sweep the debris off the deck. 9. Apply 2 coats of A-1100 Texture and Concrete Color Seal with a roller at a rate of 125 to 150 square feet per gallon. Allow it to dry between coats. Notes Drains Galvanized Thunderbird drains (2 or 3 ) are mandatory, and should be placed no more than 6 feet apart from each other. They must be nailed and caulking must be placed under and around the drains. If drains are needed, an overflow drain must also be installed. See plans or specifications for your project. Scuppers Galvanized scuppers 2 x 3 or better, no more than 6 feet apart from each other. Joists 2 x 8 s, 16 on center with ¼ fall per foot better. Plywood 5/8 or better, exterior grade, tongue and groove plywood, blocked and glued, with ¼ fall per foot. Nails should be screws or ring-shank nails. No OSB board or particleboard. This system is not approved over plywood that is less than 5/8 in thickness. Sloping This can be done by mixing one 50-pound bag of A-900 Waterproofing Basecoat with 1 gallon of A-300 Concrete Bonder Admix. Prime the surface before application with A-300 Concrete Bonder Admix. Do not allow the primer to dry before applying A-900 Waterproofing Basecoat. Product Warranty: Americrete, Inc. blends its products to the highest quality. Warranty does not apply to any persons, company or private individuals who have not attended an Americrete, Inc. training class and/or have not been approved as a Certified Applicator of Americrete, Inc. products. This warranty is limited to the replacement of material (product) for a period of 1 year for single product application and for a period of 5 years for entire system application only if the maintenance has been performed as stated above and the product(s) have been proven to be defective. Product must be applied to manufacturers specifications, and over a sound substrate. There is no warranty for cracking, damage to substrates or replacement of any tangible items. This warranty, dated October 2004, supercedes all previous warranties.

A-9,000 Page 5 Note: Americrete products are to be applied only when surface temperatures are at 55 degrees or higher. Do not apply when rain or other precipitation is expected within 24 hours.