Technical Data. Line Protection Miniature Circuit Breakers (MCB) Residual Current Devices (RCD) Isolators Switch-disconnectors

Similar documents
R.C.C.B. s two-pole LEXIC

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

The complete range of consumer switchboards and switchgear

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Electronic overload relay EF19 and EF45

Type: DILM32 10(24V50HZ) Article No.:

Residual Current Protective Devices

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM9 10(24VDC) Article No.:

Circuit Breaker. Description

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Electronic overload relay EF65, EF96 and EF146

SELECTION OF FINAL CIRCUIT PROTECTION

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

RCD Type F Residual current protection for single phase inverters applications

Residual Current Circuit Breaker

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

How can a charging station for electric vehicles be set up simply and safely?

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

System pro M compact Miniature Circuit Breaker S 200/S 200 M

MOTOR PROTECTIVE DEVICES

Distribution Boards & Consumer Units

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

5SV Residual Current Protective Devices

Product and functional description

Bimetallic Overload Relay Specifications

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

ADM1TE 5/30A DIN rail single phase two wire energy meter

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Circuit Breakers. Next Generation of Protection Capabilities

Residual current socket 30mA Order No.:

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Manual motor starter MS116

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Unified requirements for systems with voltages above 1 kv up to 15 kv

Three-phase monitoring relay CM-PFE

Breaking and protection devices

Vario-Series Accessories

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Bulletin 1489 Circuit Breakers. Selection Guide

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

How To Build A Low Voltage Capacitor Lvcp

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ABB solutions for photovoltaics Protection and other modular devices

Safety technique. Emergency stop module BO 5988 safemaster

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Protection catalogue 15

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Thermal-Magnetic Circuit Breaker M1-..

AC1645. System pro M compact Supplementary Protectors Miniature MCCBs

CONTINUOUS MONITORING AND AVOIDANCE OF RESIDUAL CURRENTS IN DATA CENTRES WITH RCM White paper Revision 2

RM4TG20 three-phase network control relay RM4-T - range V

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Digital input modules

Manual Motor Starter MS 116 up to 16 A Technical Data

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

SURGE PROTECTIVE DEVICES

BETA Protecting SITOR Semiconductor Fuses

Low Voltage Products. Switches Automatic Transfer Switches

E-STOP relays, safety gate monitors

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Relés e Contatores de Estado Sólido SIRIUS

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Catalogue May EasyLine XLP Fuse Switch Disconnector pole

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Technicaldata General

6.0 Electrical Installations

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

Tmax MCCBs. Molded case circuit breakers. Tmax

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Technical Redline ED.03

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Guide to the Selection & Use of Residual Current Devices

Use of Residual Current Devices in Departmental Infrastructure

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

8146/5 Series Breaker Panelboards

QUICK REFERENCE PRICE GUIDE JULY 2015

PSR The compact range Description

Transcription:

Technical Data Miniature Circuit Breakers (MCB) Residual Current Devices (RCD) Isolators Switch-disconnectors

MCBs Product Overview SH200 The new SH200 MCBs can be used in domestic, commercial and industrial applications for protection against over-current and short circuit. MCB New Enhancement Optimized connection terminal The new terminal makes it possible to connect lines with and without wire end sleeves up to a cross section of 35mm 2. The integrated pressure plate serves as protection against damage to flexible lines. SH201 Laser printing Laser printing ensures a clean typeface with high contrast. This ensures a clear readability. It is resistant to scratches, abrasion and solvents, making it absolutely non-forgeable. Improved DIN rail mounting The new plastic lug on the back of the devices prevents them from becoming displaced on the DIN rail in all mounting positions. In the multi-pole miniature circuit breakers this is achieved by using an additional spring in the fastening clip. S280UC The S280UC MCB s can be used up to 220V DC for single pole (17.5mm) or up to 440V DC for double pole (35mm) with series connections of 2 poles. This enhanced DC performance is in addition to the AC performance. SH202 They differ from the standard devices in that they are fitted with a permanent magnet which assists in the forced extinguishing of the arc. It is therefore important that care is taken to observe the correct polarity and current flow direction when connecting these breakers. Tripping Curve Characteristic B, C, D S282UC multiples of rated current 1

MCBs Technical Data MCB Type SH200 S200M S280UC Standards IEC60898 IEC/EN60898, IEC/EN60947-2 IEC/EN60947-2 Pole 1, 2, 3, 4 1, 2, 3 (for type C) Tripping Characteristics B, C, D B, C, D B, C Tripping Type Electro-Magnetic Type Rated breaking capacity Icu 6kA 10kA (1-63A) 6kA (0.5-32A) 4.5kA (40-63A) Rated current In 6-63A 6-63A 6-25A (for type B) 0.5-63A (for type C) Rated voltage AC single pole Un 230V 230V AC multi-pole Un 400V 400V DC single pole Un - 220V DC multi-pole Un - 400V Frequency Hz 50-60 Mechanical Life no. of operation Electrical Life no. of operation 20,000 10,000 Protection degree Terminals Housing IP2X IP4X Ambient temperature Operating Temperature Storage Temperature C C -25...+55-40...+70 Tropicalization constant climate conditions [ C/RH] variable climate conditions [ C/RH] Terminal Size mm 2 23/83, 40/93, 55/20 25/95, 40/95 0.75-35 0.75-25 Tightening Torque Nm 2 2.5 2

MCBs - SH200 Order Information MCB Type Designation SH 201 M - C 10 Rated Current (A) : 6, 10, 16, 20, 25, 32, 40, 50, 63 Tripping Characteristic : B, C, D Breaking Capacity : M = 10kA Blank = 6kA No. of poles : 1, 2, 3, 4 Series : S200 Model : SH SH201 Characteristic B Rated current Breaking capacity SH200-B (A) (ka) 1 Pole 2 Poles 3 Poles 4 Poles 6 SH201-B6 SH202-B6 SH203-B6 SH204-B6 10 SH201-B10 SH202-B10 SH203-B10 SH204-B10 16 SH201-B16 SH202-B16 SH203-B16 SH204-B16 20 SH201-B20 SH202-B20 SH203-B20 SH204-B20 25 6 SH201-B25 SH202-B25 SH203-B25 SH204-B25 32 SH201-B32 SH202-B32 SH203-B32 SH204-B32 40 SH201-B40 SH202-B40 SH203-B40 SH204-B40 50 SH201-B50 SH202-B50 SH203-B50 SH204-B50 63 SH201-B63 SH202-B63 SH203-B63 SH204-B63 SH202 Characteristic C Rated current Breaking capacity SH200-C (A) (ka) 1 Pole 2 Poles 3 Poles 4 Poles 6 SH201-C6 SH202-C6 SH203-C6 SH204-C6 10 SH201-C10 SH202-C10 SH203-C10 SH204-C10 16 SH201-C16 SH202-C16 SH203-C16 SH204-C16 20 SH201-C20 SH202-C20 SH203-C20 SH204-C20 25 6 SH201-C25 SH202-C25 SH203-C25 SH204-C25 32 SH201-C32 SH202-C32 SH203-C32 SH204-C32 40 SH201-C40 SH202-C40 SH203-C40 SH204-C40 50 SH201-C50 SH202-C50 SH203-C50 SH204-C50 63 SH201-C63 SH202-C63 SH203-C63 SH204-C63 Characteristic D SH203 Rated current Breaking capacity SH200-D (A) (ka) 1 Pole 2 Poles 3 Poles 4 Poles 6 SH201-D6 SH202-D6 SH203-D6 SH204-D6 10 SH201-D10 SH202-D10 SH203-D10 SH204-D10 16 SH201-D16 SH202-D16 SH203-D16 SH204-D16 20 SH201-D20 SH202-D20 SH203-D20 SH204-D20 25 6 SH201-D25 SH202-D25 SH203-D25 SH204-D25 32 SH201-D32 SH202-D32 SH203D32 SH204-D32 40 SH201-D40 SH202-D40 SH203-D40 SH204-D40 50 SH201-D50 SH202-D50 SH203-D50 SH204-D50 63 SH201-D63 SH202-D63 SH203-D63 SH204-D63 3

MCBs - S200M Order Information Characteristic B S201M Rated current Breaking capacity S200M-B (A) (ka) 1 Pole 2 Poles 3 Poles 4 Poles 6 S201M-B6 S202M-B6 S203M-B6 S204M-B6 10 S201M-B10 S202M-B10 S203M-B10 S204M-B10 16 S201M-B16 S202M-B16 S203M-B16 S204M-B16 20 S201M-B20 S202M-B20 S203M-B20 S204M-B20 25 10 S201M-B25 S202M-B25 S203M-B25 S204M-B25 32 S201M-B32 S202M-B32 S203M-B32 S204M-B32 40 S201M-B40 S202M-B40 S203M-B40 S204M-B40 50 S201M-B50 S202M-B50 S203M-B50 S204M-B50 63 S201M-B63 S202M-B63 S203M-B63 S204M-B63 MCB S202M Characteristic C Rated current Breaking capacity S200M-C (A) (ka) 1 Pole 2 Poles 3 Poles 4 Poles 6 S201M-C6 S202M-C6 S203M-C6 S204M-C6 10 S201M-C10 S202M-C10 S203M-C10 S204M-C10 16 S201M-C16 S202M-C16 S203M-C16 S204M-C16 20 S201M-C20 S202M-C20 S203M-C20 S204M-C20 25 10 S201M-C25 S202M-C25 S203M-C25 S204M-C25 32 S201M-C32 S202M-C32 S203M-C32 S204M-C32 40 S201M-C40 S202M-C40 S203M-C40 S204M-C40 50 S201M-C50 S202M-C50 S203M-C50 S204MC50 63 S201M-C63 S202M-C63 S203M-C63 S204M-C63 S203M Characteristic D Rated current Breaking capacity S200M-D (A) (ka) 1 Pole 2 Poles 3 Poles 4 Poles 6 S201M-D6 S202M-D6 S203M-D6 S204M-D6 10 S201M-D10 S202M-D10 S203M-D10 S204M-D10 16 S201M-D16 S202M-D16 S203M-D16 S204M-D16 20 S201M-D20 S202M-D20 S203M-D20 S204M-D20 25 10 S201M-D25 S202M-D25 S203M-D25 S204M-D25 32 S201M-D32 S202M-D32 S203M-D32 S204M-D32 40 S201M-D40 S202M-D40 S203M-D40 S204M-D40 50 S201M-D50 S202M-D50 S203M-D50 S204M-D50 63 S201M-D63 S202M-D63 S203M-D63 S204M-D63 4

MCBs Order Information Characteristic B MCB Rated current Breaking capacity S280UC-B (A) (ka) 1 Pole 2 Poles 6 S281UC-B6 S282UC-B6 10 S281UC-B10 S282UC-B10 16 6 S281UC-B16 S282UC-B16 20 S281UC-B20 S282UC-B20 25 S281UC-B25 S282UC-B25 S281UC S282UC Characteristic C Rated current Breaking capacity S280UC-C (A) (ka) 1 Pole 2 Poles 3 Poles 0.5 S281UC-C0.5 S282UC-C0.5 S283UC-C0.5 1 S281UC-C1 S282UC-C1 S283UC-C1 1.6 S281UC-C1.6 S282UC-C1.6 S283UC-C1.6 2 S281UC-C2 S282UC-C2 S283UC-C2 3 S281UC-C3 S282UC-C3 S283UC-C3 4 S281UC-C4 S282UC-C4 S283UC-C4 6 6 S281UC-C6 S282UC-C6 S283UC-C6 8 S281UC-C8 S282UC-C8 S283UC-C8 10 S281UC-C10 S282UC-C10 S283UC-C10 16 S281UC-C16 S282UC-C16 S283UC-C16 20 S281UC-C20 S282UC-C20 S283UC-C20 25 S281UC-C25 S282UC-C25 S283UC-C25 32 S281UC-C32 S282UC-C32 S283UC-C32 40 S281UC-C40 S282UC-C40 S283UC-C40 50 4.5 S281UC-C50 S282UC-C50 S283UC-C50 63 S281UC-C63 S282UC-C63 S283UC-C63 5

MCBs Dimensions (mm) SH200 / S200M MCB 1 pole 2 poles 3 poles 4 poles S280UC 66 (single pole) 68 (multi-pole) 1 pole 2 poles 3 poles 6

Residual Current Devices (RCD) Product Overview RCD GSH201 The Earthed Fault Current is the flow of electricity from the power supply leaking towards the earth, under faulty electrical condition. Its degree of danger depends on the amount of leakage and the surrounding conditions. Users of leaking equipment may get electrical shock. If this current persists for a long time, fire hazard may be caused. A residual current operated circuit breaker can be installed on the distribution system in order to detect the leakage and cut off the circuit before any damaged occurs. ABB s offer both residual current operated breaker with (the RCBO) and without (the RCCB) integral over-current protection. Both breakers employ zero current transformer (ZCT) and permanent electro-magnet or electronic tripping mechanism, giving a high sensitivity for detecting and cutting off faulty current. GSH201 - electronic RCBO The earthed protection devices GS200 series protects users against leakage current. The series adopts Italy designed residual current detection circuit with high electromagnetic compatibility (EMC). The devices comply to the international IEC61009 standard. DS251 DS251 & DS271 - electronic RCBO Besides protection against earthed faults, the DS251 & DS271 series electronic RCBO also protect the single-phase circuits from overloading or short circuit. DS201 - electromagnetic RCBO The new residual current circuit-breakers with over current protection are a technologically advanced and comprehensive range, as concerns size, tripping characteristics, breaking capacity and accessories. The new RCBOs are integrated in the System pro M compact range, with the identical profile that lends a coordinated and streamlined look to the installation. DS201 FH200 and F200 - RCCB RCCBs are only sensitive to current leakage to earth. They must be used in series with an MCB or fuse which protects them from the potentially damaging thermal and dynamic stresses of any overcurrents. These devices are used in systems already equipped with MCBs which preferably limit the specific energy passing through, also acting as the main disconnecting switches upstream of any derived MCBs (e.g. domestic consumer unit). FH202 7

Residual Current Devices (RCD) Technical Data Type GSH201 DS251 DS271 DS201 FH200 / F200 Standards IEC61009 IEC61009, BSEN 61009-2-2 IEC61009 IEC/EN61008 Pole 1P + N 1P + N 1P + N 1P + N 2, 4 Tripping Characteristics Tripping Type B, C, D Electronic Type C B, C C Electro-Magnetic Type - RCD Rated breaking capacity Icu 6kA 6kA 10kA 6kA, 10kA - Rated current In 6-63A 6-32A 6-32A 6-40A 25-63A (FH200) 80-100A (F200) Rated voltage Un / AC 230V 230 / 240V 230 / 240V 230V 230 / 400V Type AC AC AC AC AC Rated sensitivity ma 30 30 10, 30, 100, 30 30, 100, 300 300 (for type C) Frequency Hz 50-60 Mechanical Life no. of operation 20,000 Protection degree Terminals Housing IP2X IP4X Ambient temperature Operating Temperature Storage Temperature C C -25...+55-40...+70-25...+55-25...+70-25...+55-35...+70 Tropicalization (IEC 60068-2) constant climate conditions [ C/RH] variable climate conditions [ C/RH] 23/83, 40/93, 55/20 25/95, 40/93 Terminal Size mm 2 0.75-35 1-25 (Line side) 1-16 1-25 1-10 (Load side) Tightening Torque Nm 2 2 (Line side) 2 1.2 (Load side) 8

Residual Current Devices (RCD) Order Information Type Designation RCD GSH 20 1 AC - B 10 / 0.03 Rated residual current : 30mA Rated current : 6-63A Tripping Characteristics : B, C, D Tripping Time : AC - Instantaneous Pole : 1 + NA Series : S200 Model : GSH (Electronic Type) DS (Electro-magnetic Type) GSH201 (RCBO) GSH201 Rated current Rated residual AC Type (1 Pole + N) (A) current (ma) 6kA (B characteristic) 6kA (C characteristic) 6kA (D characteristic) 6 GSH201 AC-B6/0.03 GSH201 AC-C6/0.03 GSH201 AC-D6/0.03 10 GSH201 AC-B10/0.03 GSH201 AC-C10/0.03 GSH201 AC-D10/0.03 16 GSH201 AC-B16/0.03 GSH201 AC-C16/0.03 GSH201 AC-D16/0.03 20 GSH201 AC-B20/0.03 GSH201 AC-C20/0.03 GSH201 AC-D20/0.03 25 30 GSH201 AC-B25/0.03 GSH201 AC-C25/0.03 GSH201 AC-D25/0.03 32 GSH201 AC-B32/0.03 GSH201 AC-C32/0.03 GSH201 AC-D32/0.03 40 GSH201 AC-B40/0.03 GSH201 AC-C40/0.03 GSH201 AC-D40/0.03 50 GSH201 AC-B50/0.03 GSH201 AC-C50/0.03 GSH201 AC-D50/0.03 63 GSH201 AC-B63/0.03 GSH201 AC-C63/0.03 GSH201 AC-D63/0.03 DS201 (RCBO) C Characteristic DS201 Rated current Rated residual AC Type (1 Pole + N) (A) current (ma) 6kA (DS201) 10kA (DS201M) 6 DS201 C6 AC30 DS201 M C6 AC30 10 DS201 C10 AC30 DS201 M C10 AC30 16 DS201 C16 AC30 DS201 M C16 AC30 20 30 DS201 C20 AC30 DS201 M C20 AC30 25 DS201 C25 AC30 DS201 M C25 AC30 32 DS201 C32 AC30 DS201 M C32 AC30 40 DS201 C40 AC30 DS201 M C40 AC30 9

Residual Current Devices (RCD) Order Information DS251 (RCBO) AC Type C Characteristic Rated current Breaking Capacity Rated residual (A) (ka) current (ma) 1 Pole + N 6 DS251 AC-C6 / 0.03 10 DS251 AC-C10 / 0.03 16 6 30 DS251 AC-C16 / 0.03 20 DS251 AC-C20 / 0.03 25 DS251 AC-C25 / 0.03 32 DS251 AC-C32 / 0.03 DS251 DS271 (RCBO) AC Type B Characteristic RCD DS271 Rated current Breaking Capacity Rated residual (A) (ka) current (ma) 1 Pole + N 6 DS271 AC-B6 / 0.01 10 DS271 AC-B10 / 0.01 16 10 DS271 AC-B16 / 0.01 20 DS271 AC-B20 / 0.01 25 DS271 AC-B25 / 0.01 32 DS271 AC-B32 / 0.01 6 DS271 AC-B6 / 0.03 10 DS271 AC-B10 / 0.03 16 10 30 DS271 AC-B16 / 0.03 20 DS271 AC-B20 / 0.03 25 DS271 AC-B25 / 0.03 32 DS271 AC-B32 / 0.03 6 DS271 AC-B6 / 0.1 10 DS271 AC-B10 / 0.1 16 100 DS271 AC-B16 / 0.1 20 DS271 AC-B20 / 0.1 25 DS271 AC-B25 / 0.1 32 DS271 AC-B32 / 0.1 C Characteristic Rated current Breaking Capacity Rated residual (A) (ka) current (ma) 1 Pole + N 6 DS271 AC-C6 / 0.01 10 DS271 AC-C10 / 0.01 16 10 DS271 AC-C16 / 0.01 20 DS271 AC-C20 / 0.01 25 DS271 AC-C25 / 0.01 32 DS271 AC-C32 / 0.01 6 DS271 AC-C6 / 0.03 10 DS271 AC-C10 / 0.03 16 30 DS271 AC-C16 / 0.03 20 DS271 AC-C20 / 0.03 25 DS271 AC-C25 / 0.03 32 10 DS271 AC-C32 / 0.03 6 DS271 AC-C6 / 0.1 10 DS271 AC-C10 / 0.1 16 100 DS271 AC-C16 / 0.1 20 DS271 AC-C20 / 0.1 25 DS271 AC-C25 / 0.1 32 DS271 AC-C32 / 0.1 6 DS271 AC-C6 / 0.3 10 DS271 AC-C10 / 0.3 16 300 DS271 AC-C16 / 0.3 20 DS271 AC-C20 / 0.3 25 DS271 AC-C25 / 0.3 32 DS271 AC-C32 / 0.3 10

Residual Current Devices (RCD) Order Information FH200 (RCCB) RCD FH202 Rated current Rated residual AC Type (A) current (ma) 2 Poles 4 Poles 25 FH202 AC-25 / 0.03 FH204 AC-25 / 0.03 40 30 FH202 AC-40 / 0.03 FH204 AC-40 / 0.03 63 FH202 AC-63 / 0.03 FH204 AC-63 / 0.03 25 FH202 AC-25 / 0.1 FH204 AC-25 / 0.1 40 100 FH202 AC-40 / 0.1 FH204 AC-40 / 0.1 63 FH202 AC-63 / 0.1 FH204 AC-63 / 0.1 25 FH202 AC-25 / 0.3 FH204 AC-25 / 0.3 40 300 FH202 AC-40 / 0.3 FH204 AC-40 / 0.3 63 FH202 AC-63 / 0.3 FH204 AC-63 / 0.3 F200 (RCCB) Rated current Rated residual AC Type (A) current (ma) 2 Poles 4 Poles 80 30 F202 AC-80 / 0.03 F204 AC-80 / 0.03 100 F202 AC-100 / 0.03 F204 AC-100 / 0.03 80 100 F202 AC-80 / 0.1 F204 AC-80 / 0.1 100 F202 AC-100 / 0.1 F204 AC-100 / 0.1 80 300 F202 AC-80 / 0.3 F204 AC-80 / 0.3 100 F202 AC-100 / 0.3 F204 AC-100 / 0.3 F202 11

Residual Current Devices (RCD) Dimensions (mm) GSH201 DS251 / DS271 67.6 43.5 DS201 - DS202C 45 85 RCD 67.6 43 58 67 73 17.5 35 FH200 / F200 2 poles 4 poles 12

Isolators and Switch-disconnectors Product Overview E202 Isolator E200 Forced opening and suitable for use as main switch. High short circuit withstanding capacity. Optimal protection against unintentional touch of live parts. Dual-function terminals Quick mounting clip, lockable in open position. The switch-isolators are equipped with dual-function terminals which enable simultaneous connection of conductors and busbar. Cross-/ slotted-head screws size 2, system Pozidriv, enable easy, reliable and timesaving wiring. Facility for sealing or padlocking in closed or isolated position. Internal connection of switching mechanisms ensures simultaneous switching even without toggle linkage. Isolators and Switch-disconnectors OT160 Switch-disconnector OT - Uniquely short current path enable a small sized contact construction. - Quick-make and quick-break operation features and two contact points. - User-friendly and flexible, full AC-23A current rating for all the voltage up to 690V. - Mountable on DIN rails or base plates and on the door, both by snap-on and screw fitting. Technical Data Type E200 OT160 OT200 Standard IEC60439-3 Rated short-time Icw withstand current 20 In 1s 4 ka 1s 8 ka 1s Rated short current capacity Icm 15 In 12 ka 30 ka Rated current In 63-125 A 160 A 200 A Rated Operational current - 200 / 135 200 / 200 AC22A/AC23A 400V [A/A] OT200 Ordering Information E200 Rated current E200 (A) 2 Poles 3 Poles 4 Poles 63 E202 / 63r E203 / 63r E204 / 63r 80 E202 / 80r E203 / 80r E204 / 80r 100 E202 / 100r E203 / 100r E204 / 100r 125 E202 / 125r E203 / 125r E204/ 125r OT Rated current OT (A) 3 Poles 4 Poles 160 OT160E3 OT160E4 200 OT200E30P OT200E40P 13

Isolators and Switch-disconnectors Dimensions (mm) E200 2 poles 3 poles 4 poles OT160 Isolators and Switch-disconnectors OT200 OT200E03P OT200E04P A 145.5 180.5 A1 125 160 B1 141 176 C1 155 190 14

Contact us ABB (Hong Kong) Ltd. L.V. Products 3 Dai Hei Street, Tai Po Industrial Estate N.T., Hong Kong Tel : (852) 2929 3912 Fax : (852) 2929 3505 E-mail : market.hkabb@cn.abb.com 1SXE420001L0202 09-2011 OXY 2000 www.abb.com