Conventional & Twin-wire Fire System

Similar documents
Engineer Paging. Staff Paging. Deaf Alert.

Conventional Fire Detection and Extinguishant Control System Specification

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

CB200W Water Leak Detection Panel Application Guide

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Product Data Sheet. User Manual. User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels

FIREDEX Conventional Fire Panels

ACTIVE 5 ENGINEERING MANUAL

9452/9453 Installation and User Guide

VEGA Analogue Addressable Control Panels

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

Repeaters and Mimics Data Sheet

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

AlarmSense 2-wire detection and alarm system. Product Guide

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

CFP 2/4/8 ZONE CONVENTIONAL FIRE ALARM CONTROL PANEL. user manual & log book. Approved Document No. DFU Rev 1

Control/Communicator Installation Manual

GST301. (Single Protection Zone) Operation Manual

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

SFC-200 SERIES LCD FIRE ALARM PANEL

SECTION DETECTION AND ALARM

CONTENTS 4. HOW TO UNSET THE PANEL...7

User s Information Guide R1A

Installation and Operation Manual

Surveyor Excel-K. Fire Alarm Control Equipment. Installation, Commissioning and Operating Manual

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide

LPCB APPROVED CFP 2/4/8 ZONE FIRE ALARM CONTROL PANEL. installation & maintenance manual. Approved Document No. DFU Rev 1

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

Fire Detection Product Range

616, 626, 636 & 646 Keypads

How To Set A Timer On A Gg System

CFP 2/4/8 ZONE ECONOMY FIRE ALARM CONTROL PANEL. installation & maintenance manual. Approved Document No. DFU Rev 1

IMPORTANT USER INFORMATION

Secure Keypads for access control

SECURIT 800L+ CONTROL PANEL

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

INSTALLATION MANUAL CONTENTS

500r+ Installation and User Guide

TS510 & TS500. Installation & User Guide. Compatible Equipment

Using your LED Plus keypad

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication

HARDWIRED CONTROL PANELS

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

SmartLine. Conventional Fire Detection Control Panel. Extinguishant system Control Panel. User's Manual. GameOver

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

9448 Installation and User Guide

Syncro. Multi Loop Analogue Addressable Fire Control Panel. Product Manual Man-1055 Issue 26 May 2016

D200+ Auto-Dialler Installation/Operators Manual

conventional system operation

Premier M Plus & Infinity 8

Fire Pump Controllers Remote Alarm Panels

MSL1000 Monitored Serial Link Interface Manual V1.01

SYSTEM 7000 IRIS+ USER MANUAL

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Kentec Electronics Ltd. Units Fawkes Avenue Questor Dartford Kent DA1 1JQ England Tel: +44(0) Fax: +44(0)

SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T.

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panels. Issue 12

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

SECURIT 800L+ CONTROL PANEL

Syncro. Multi Loop Analogue Addressable Fire Control Panel. Product Manual. Man-1055 Issue 21 September 2010

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

INSTALLATION MANUAL PC2525. Version 1.1

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

RP1r. Extinguishing Control Panel. User Manual (Software version 3.x) 3 zone control panel to protect 1 extinguishing risk

21. Power supply Maintenance... 22

HyperAccess Access Control System

9x5x PROGRAMMING GUIDE

ICP-CP500. User's Guide ICP-CP500 Codepads

3. MOUNTING THE FIRE ALARM PANEL PLANNING CABLE ENTRY 3.2 FIXING THE BACKBOX TO THE WALL

NESS D Zone Control Panel and Dialler OWNER S MANUAL

SPECIAL CONTROL BUTTON FUNCTIONS

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual Man-1096 Issue 14 May 2016

NetworX Series. NX-216E Zone Expander Module Installation and Startup

INTRUSION DETECTION SYSTEM Section

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

Industrial Training Schedule Spring 2012

User Guide Premier Elite 24/48/88/168/640

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

D24 USER S MANUAL ALARM CONTROL PANEL AND DIALLER. Ness D24 control panel User s manual A$15.00 INC GST. Revision 2

Global System Technology(UK) PLC The Intelligent Solution

CAPTAIN 6. USER GUIDE System ver Zones Intruder Alarm System. PIMA Electronic Systems Ltd.

DTW Works Master Specification Version 2006

Operator's Handbook Autroprime Interactive Fire Detection System

BS5839 Part 1:2002 Overview

Fire alarm system EBL512 G3

642 LCD Keypad User Manual

ACP10 10 Zone Intruder Alarm System

Transcription:

Conventional & Twin-wire Fire System

Advanced Customer Service At Advanced we re not just famous for our fire systems. Our Advanced360 customer support, service and technical training are widely acknowledged as industry leading. The Advanced360 team works hard to ensure you fi nd an Advanced system easy to specify, install, confi gure and maintain, no matter how demanding your installation. It s another reason why we set The Standard in Fire Systems. UK Tel: +44 (0)1670 707 111 Dubai Tel: +971 4 299 0908 Email: sales@advancedco.com Web: www.advancedco.com

Contents About Advanced 3 QuickZone & QuickZone XL 4 Panel Overview 5 False Alarm Management 6 Programming Features 6 AdSpecials 7 QuickZone Product List 7 About Advanced Manufacturing and Quality Admin Customer Service and Support R&D Advanced is known all over the world for making the highest quality, best performing fire systems. We design easy into our products. We make it easy to set up a one panel system or a complicated 200 panel network and we make our software intuitive. We deliver fast, accessible support, training and service. Above all, we make it easy to rely on Advanced. Fire Systems are in our DNA. The people that started Advanced are the people that spearheaded the intelligent fire systems industry. They still work at Advanced and we train talented engineers and technologists every year. Over 25% of our business is dedicated to R&D. Our knowledge is unmatched, anywhere in the world and we re determined to keep it there. Our systems are protecting people and property in over 60 countries worldwide, in many of the most prestigious and challenging locations. We realise our growth comes from strong customer relationships. We stay friendly, flexible and reactive to your requirements and our customer service is consistently rated excellent. We manufacture all of our panels in the UK to demanding quality standards and hold global approvals. We enjoy full ISO 9001 compliance across manufacturing and design. 3

The Advanced Conventional and Twin-wire Fire System. QuickZone and QuickZone XL fire panels support 2-12 zones, are approved to EN54-2&4 and deliver a host of performance, configuration and programming features. A QuickZone system, as the name suggests is quick and simple to install and manage. QuickZone s standard and XL panel formats allow absolutely the best solution to be selected and make it ideal for any installation where a conventional panel is required. Quick on the Wall Sturdy metal enclosure Multiple knockouts Easy-change PCBs Ample space for wiring Integral, switch mode, 1.25/2.5 Amp PSU Quick to Configure Up to 12 Fire zones DIL switch selection of twin-wire /conventional format 2 open collector outputs 2 volt-free contacts 28V output Zone interface function allows last zone to be set via DIL for non-latching operation Simple access to batteries Metal earth bar (no crimping) No end-of-line modules required Compatible with a wide range of conventional detectors 2 inputs (class change and alert) Up to 6 sounder circuits Spare zones can be used as sounder circuits Common fire output and relay can be programmed to cancel on silence Modular expansion zone cards available XL system includes repeater panel Quick to Maintain Simple, clear LED indication of Fire, system status and zone status One-button fault diagnosis Colour coded keypad to manage Resound, Silence, Reset, Test, Disable, Mute and Test Lamps Simple 3 level programming accessible by keyswitch or keycode and DIL Disablements removed with one code Factory reset option 3 button action to disable zones Buzzer mute in Fault condition In test mode, tests can be run with or without sounders False alarm management 40 event log (XL only) Full, industry leading technical support from Advanced 3 year warranty 4

Panel Overview Advanced s QuickZone solution covers three panels across two product lines that allows installers to specify the system that matches their performance and price requirements. QuickZone is the most straightforward panel in the range and is appropriate for quick, simpler installations. QuickZone XL is a feature rich panel that can support passive or fully functional repeaters and is ideal for larger conventional/twin-wire installations with more involved programming and configuration requirements. 2 or 4 zones DIL selectable conventional or twin-wire (sav-wire) set up Class change and alert inputs Fire and fault relays 2 monitored sounder circuits 1.25 Amp switch mode PSU Space for up to 3.2Ah batteries False alarm management Approved to EN54-2&4 3 year warranty 4-12 zones DIL selectable conventional or twin-wire (sav-wire) set up per zone Integral 2.5 Amp switch mode PSU Up to 7 Ah batteries Class change and alert programmable inputs Programmable relays and outputs Up to 6 monitored sounder circuits Integral detector removal monitoring Test mode (with and without sounders) Alarm load of 2.4A shared across all sounder outputs Modular expansion zone cards available 2 additional sounder circuits with expansion card False alarm management Zonal programming Programmable outputs Programmable output delays Supports up to 8 QuickZone XL Repeater panels Approved to EN54-2&4 3 year warranty Repeater Same easy-to-use controls and indications as panel Can be fully functional or passive 12 zonal fault and fire indication 1.25 Amp integral PSU Class change and alert input Test mode and disablement functions Up to 8 per main panel Approved to EN54-2&4 3 year warranty 5

False Alarm Management QuickZone false alarm management functions according to one of three different modes as described in EN54-2. QuickZone supports mode A while QuickZone XL supports all three modes. False alarm management can be selected for individual zones on both panels. Mode A: The first alarm is not indicated and the sounders do not activate. The panel resets and rechecks the zone within 15-30 seconds, if an alarm is detected the panel activates a full fire condition. Any new alarm from the same or a different zone within 30 minutes also activates a full fire condition. Mode B: The first alarm will indicate at the panel but the sounders do not activate. The panel resets and rechecks the zone within a programmable time period (1 4 minutes). If an alarm is detected the panel activates a full fire condition. Any new alarm from the same or a different zone within a second programmable time period of 5 to 30 minutes will also activate a full fire condition unless the reset button is pressed. Mode C: The first alarm will indicate at the panel but the sounders do not activate. The panel will not activate a full fire condition unless a second device is activated in the same or a different zone. Programming Features Zone Function Programming: To maximise configuration options, QuickZone allows individual zones to have specific programmed options including: Set as latching or non-latching Short circuit = Fire for monitoring Specified for MTL5061 I.S. barrier compatibility Compatible with schottky or zener diode bases False alarm management modes Set delays to outputs Silent mode for indication purposes - visual and audible alarm at panel but no sounder operation Detector removal monitoring can be turned off for older non-approved detectors (non-compliant to EN54). Twin wire zone can be programmed to zone of origin continuous ringing. Other zones can be set to pulsing, silence or continuous. Inputs: Two independent programmable inputs - class change and alert input Either or both inputs can be programmed for remote evacuation, remote silence alarm, remote reset. Inputs programmable for indication purposes so the zone 12 LED or fault LED will illuminate. Outputs: Can be set to latching Fault outputs can be inverted Aux relays and all outputs, including sounders, are independently programmable: On, off or pulsing Programmed to a dedicated zone Programmed with a custom response to silence alarm, evacuate, class change input, alert input or during zone delay. Other sounders can be switched off, pulsing or continuous Output delays can be applied to aux outputs and sounders (for example investigation delay for false alarm management). 6

Custom Built Panels and Control Units Advanced s special engineering and manufacturing team develops bespoke solutions for customers on the backbone of our market leading fire technology. From mimic panels and special enclosures to high specification control units and monitoring stations, the AdSpecials team s work is found in thousands of locations worldwide. Offering a consultancy, design and build service, the AdSpecials department is the epitome of what makes Advanced a manufacturer of choice - we go further to provide customers with exactly what they need. Product List Product Code QZ-2 QZ-4 QZXL-4 QZXL-8 QZXL-12 QZXL-8HS QZXL-12HS Description QuickZone QuickZone - 2 Zone Panel QuickZone - 4 Zone Panel QuickZone XL QuickZone XL - 4 Zone Panel QuickZone XL - 8 Zone Panel QuickZone XL - 12 Zone Panel QuickZone XL - 8 Zone Panel (c/w additional - 2 sounder outputs, 2 switched -ve outputs & 1 aux c/o relay) QuickZone XL - 12 Zone Panel (c/w additional - 2 sounder outputs, 2 switched -ve outputs & 1 aux c/o relay) Product Code QZXL-ZEC QZXL-HSZEC QZXL-R12 Description QuickZone XL Expansion Cards QuickZone XL - 4 Zone expander Card QuickZone XL - 4 Zone expander Card (c/w additional - 2 sounder outputs, 2 switched -ve outputs & 1 aux c/o relay) QuickZone XL Repeater Panel QuickZone XL - Repeater 12 Zone 7

The Standard in Fire Systems UK and EMEAA HQ Moorland Way, Cramlington, Northumberland NE23 1WE UK Tel: +44 (0)1670 707 111 Fax: +44 (0)1670 707 222 Dubai Office Dubai Airport Free Zone, Building W3, Office 211, Dubai UAE Tel: +971 4 299 0908 Fax: +971 4 299 0554 Email: sales@advancedco.com Web: www.advancedco.com