Recommended ParBERT 81250 MIPI D-PHY configurations There are two MIPI D-PHY configurations available with the ParBERT 81250. The main differences between these two configurations are the maximum data rate and jitter injection capabilities: The first of these configurations is the 3.35 GBit/s economic configuration with 500 ps jitter injection capability. The maximum data rate of 3.35 GBit/s limits the usage of Par- BERT modules for other standards and applications. The second ParBERT 81250 MIPI D-PHY configuration is the 7 GBit/s multi application setup. As this setup up includes 7GBit/s ParBERT modules it can support a wider range of standards and applications. The table below shows the differences between the two configurations in relation to jitter injection capabilities. Seperate jitter on clock and data lanes 3.35 Gbit/s Economic Solution 7 Gbit/s Multi-application Solution Possible setup suggests clean Possible setup suggests clean clock clock lane and jitter on data lane and jitter on data lanes only lanes only Jitter capabilities 500 ps delay line 200 ps delay line plus jittered ParBERT clock (see below) Externally jittered ParBERT clock Not possible Data rate dependent example at 1 GBit/s Max supported jitter Data 500ps Jittered Clock + 200ps Clock 500ps (capability not used in setup) Jittered Clock + 200ps(capability not used in setup) Agilent MIPI D-PHY Configuration Guide
Configuration for the economic D-PHY solution (3.35 Gb/s) Table 1: Configuration for D-PHY solution Signal Generation 4 x 675 MBit/s generators 2 x 3.35 GBit/s generators 250 ps transition time converter 10 ns transition time converter 1 x E4832A with 4 x E4838A 1 x E4861B with 2 x E4862B 1 data lane 2 data lanes 4 data lanes Comments 2 3 5 LP signaling and HS offset 2 3 5 HS signaling 15432B 4 6 10 HS transition time Bitifeye BIT- MIPI-TTC-0001 4 6 10 LP transition time, 3rd part product Power splitter 11667B 4 6 10 Combine HS and LP signals Set of 4 SMA cables 15442-61601 3 5 (2 cables Other ParBERT items 8 (2 cables Signal connect Clock module E4808A 1 1 1 HS clock Clock module E4805B 1 1 1 LP clock ParBERT mainframe 81250A-149 1 1 1 IEEE 1394 PC link to VXI ParBERT 81250 software license Laptop including PCMCIA IEEE 1394 card 81250A-013 1 1 1 E4875A 1 1 1 Software 81250A-015 1 1 1 PC to operate the setup Power divider 11636B 1 1 1 Split LP trigger out to HS and scope Set of 4 SMA cables 15442-61601 1 (1 cable Jitter Generation 81150A with 2 channels BNC to SMA adapter SMA to SMA adapter 81150A, option 002 1 (1 cable 1 (1 cable Trigger signals 1 1 2 Noise generator 1250-2015 1 1 2 81150 output adapter 1250-1159 0 2 4 Connect power dividers Power divider 11636B 1 3 6 Split noise to ParBERT delay lines Set of 4 SMA cables 15442-61601 1 (1 cable 2 (3 cables 3 (2 cables Agilent MIPI D-PHY Configuration Guide
Configuration for the economic D-PHY solution (3.35 Gb/s) cont 1 data rate Noise Generation (one lane - use equipment for jitter ) 2 data lanes 4 data lanes Comments Power divider 11636B 2 0 0 Re-use power divider for jitter 6 db attenuator 8493C 2 2 2 SMA to SMA adapter 1250-1159 2 0 0 Re-use adapter for jitter BNC to SMA adapter 1250-2015 0 0 0 Re-use adapter for jitter Set of 4 SMA cables 15442-61601 0 0 0 Re-use cables for jitter Other 9 GHz or better DSO 90000 Scope Options tbd 1 1 1 Differential probe 1169A 2 2 2 Timing and level measurement with DSO Differential probe head High impedance probe head Control software and test automation 5380A 2 2 2 Timing and level measurement with DSO tbd 2 2 2 Level measurement with DSO N5990A option tbd 1 1 1 Control software LAN hub no Agilent part 1 1 1 Remote control instruments LAN cable no Agilent part 3 3 4 Remote control instruments Set of 4 SMA cables 15442-61601 1 (2 cables 1 (2 cables 1 (2 cables To connect scope Set of 4 SMA cables 15442-61601 -1-2 -1 Balance unused SMA cables 4 Agilent MIPI D-PHY Configuration Guide
Configuration for the multi-application (MIPI and HDMI) solution (7 Gb/s) Table 2: Configuration for multi-application solution Signal Generation 4 x 675 MBit/s generators 1 x E4832A with 4 x E4838A, 1 data lane, 2 data lanes, 4 data lanes Comments 2 3 5 LP signaling and HS offset 7 GBit/s generator N4874B 4 6 10 HS signaling 250 ps transition time converter 10 ns transition time converter 15432B 4 6 10 HS transition time Bitifeye BIT- MIPI-TTC-0001 4 6 10 LP transition time, 3rd part product Power splitter 11667B 4 6 10 Combine with HS and LP signals Adapter 3.5 mm (f) to 2.4 mm (m) 2.4 mm 50 Ohm termination 3.5 mm 50 Ohm termination N4911A-002 8 12 20 N4912A 8 12 20 Terminate unused outputs of 7 G ParBERT 1250-2206 4 6 10 Terminate unused outputs of 7 G ParBERT Set of 4 SMA cables 15442-61601 3 5 (2 cables Other ParBERT Items 8 (2 cables Signal connect Clock module E4809A 2 2 2 HS clock Clock module E4805A 1 1 1 LS clock ParBERT mainframe 81250A-149 1 1 1 IEEE 1394 PC link to VXI 81250A-013 1 1 1 ParBERT extender mainframe with IEEE1394 link ParBERT 81250 software license Laptop including PCM- CIA IEEE 1394 card 81250A-152 0 1 1 E4875A 1 1 1 81250A-015 1 1 1 PC to operate the setup BNC cable 8120-1839 1 1 1 Synchronize ESGs Power divider 11636B 3 3 3 Clock and triggering ESG Adapter n to 3.5 mm (m) E4438C, options 1E5, 506, 601 2 2 2 Signal generators 1250-1743 1 1 1 ESG output to power divider Adapter n to 3.5 mm (f) 1250-1744 1 1 1 ESG output to SMA cable SMA to SMA adapter 1250-1159 1 1 1 Combine power splitters for triggering Set of 4 SMA cables 15442-61601 2 (1 cable 2 (1 cable 2 (1 cable Agilent MIPI D-PHY Configuration Guide 5
Configuration for the multi-application (MIPI and HDMI) solution (7 Gb/s) cont Jitter Generation 81150A with two channels 81150A, option 002, 1 data lane, 2 data lanes, 4 data lanes Comments 1 1 1 Noise generator BNC to SMA adapter 1250-2015 1 2 2 81150 output adapter SMA to SMA adapter 1250-1159 0 0 4 Connect power dividers Power divider 11636B 1 2 6 Split noise to ParBERT delay lines Set of 4 SMA cables 15442-61601 1 (1 cable not 2 (2 cables not Noise Generation (one lane - use equipment for jitter ) 3 (2 cables not 1, 2 or 4 needed to distribute noise Power divider 11636B 2 0 0 Re-use power divider for jitter 6 db attenuator 8493C 2 2 2 SMA to SMA adapter 1250-1159 2 0 0 Re-use adapter for jitter BNC to SMA adapter 1250-2015 0 0 0 Re-use adapter for jitter Set of SMA cables 15442-61601 0 0 0 Re-use cables for jitter Other 9 GHz or better DSO 90000 Scope Options tbd 1 1 1 Differential probe 1169A 2 2 2 Timing and level measurement with DSO Differential probe head High impedance probe head Control software and test automation 5380A 2 2 2 Timing and level measurement with DSO tbd 2 2 2 Level measurement with DSO N5990A option tbd 1 1 1 LAN hub no Agilent part 1 1 1 Remote control instruments LAN cable no Agilent part 5 5 5 Remote control instruments Set of 4 SMA cables 15442-61601 1 (2 cables not 1 (2 cables not 1 (2 cables not Clock to data skew measurement with DSO Set of 4 SMA cables 15442-61601 -1-1 -1 Balance unused SMA cables 6 Agilent MIPI D-PHY Configuration Guide
Figure 1: System configuration diagram for 3.35 Gb/s Figure 2: System configuration diagram for 7 Gb/s Agilent MIPI D-PHY Configuration Guide 7
Related Agilent Literature How to characterize the Physical Layer of the Mobile Industry Processor Interface (MIPI D-PHY) Application Note Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct Pub.No. 5989-7184EN ParBERT 81250 5968-9188E Parallel Bit Error Ratio Tester Product Overview ParBERT 81250, Mux/Demux 5968-9695E application Application Note Productivity Assistance 5980-2160E Advanced Memory Buffer Application Note ParBERT 81250 43.2/45 G Product Overview ParBERT 81250 3.35G Optics Data Sheet E4887A HDMI TMDS Signal Generator Data Sheet Test Automation Software Platform N5990A Data Sheet For more information, please visit us at www.agilent.com/find/parbert 5989-3481EN 5988-3020EN 5988-5901EN 5989-5537EN 5989-5483EN Product specifications and descriptions in this document subject to change without notice. www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: Agilent Open www.agilent.com/find/removealldoubt www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Phone or Fax United States: Korea: (tel) 800 829 4444 (tel) (080) 769 0800 (fax) 800 829 44 (fax) (080)769 0900 Canada: Latin America: (tel) 877 894 4414 (tel) (305) 269 7500 (fax) 800 746 4866 China: Taiwan: (tel) 800 810 0189 (tel) 0800 047 866 (fax) 800 820 2816 (fax) 0800 286 331 Europe: Other Asia Pacific (tel) 31 20 547 2111 Countries: (tel) (65) 6375 8100 Japan: (fax) (65) 6755 0042 (tel) (81) 426 56 78 Email: tm_ap@agilent.com (fax) (81) 426 56 7840 Revised: 09/14/06 Agilent Technologies, Inc. 2008 May 26th 2008 5989-8379EN